HomeMy WebLinkAboutWilson_Well Abandonment_ (9) WELL ABANDONMENT RECORD For Internal Use ONLY:
This form can be used for single or multiple wells
1.Well Contractor Information: WELL ABANDONMENT DETAILS
JAM ES MORRISON 7a.Number of wells being abandoned: 1
Well Contractor Name(or well owner personally abandoning well on his/her property) For multiple injection or non-water supply wells ONLY with the same
construction/abandonment,you can submit one form.
C -4421 3.25
NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): (gal.)
GEOLOGIC EXPLORATION, INC FOR WATER SUPPLY WELLS ONLY:
Company Name 7c.Type of disinfectant used:
2.Well Construction Permit#:
List all applicable spell construction permits(i.e.County,State,Variance,etc.)ifknown 7d.Amount of disinfectant used:
3.Well use(check well use):
Water Supply Well: 7e.Sealing materials used(check all that apply):
❑Agricultural ❑Municipal/Public ❑Neat Cement Grout ❑Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout q rg � .0I), Clay
❑IndustriaUCommercial ❑Residential Water Supply(shared) ❑Concrete Grou�' ; ke »n,UX),nll Cuttings
❑Irri ation ❑ Specialty Grout 2Q22❑Gravel
Non-Water Supply Well: 21 Bentonite Slurry MAY 3 ❑ Other(explain under 7g)
OMonitoring ❑Recovery
Injection Well: 7E For each mJAi, ed a got evIIPUount of materials used:
❑Aquifer Recharge ❑GroundwaterRemediation 4.0 GALLONS
Ll-
DAquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑Stormwater Drainage
❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure:
❑Geothermal(Closed Loop) ❑Tracer ABANDONED VIA TREMIE PIPE WITH BENTONITE SLURRY
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g)
4.Date well(s)abandoned: 04/04/22
5a.Well location:
KORETIZING CLEANERS
Facility/Owner Name Facility ID#(ifapplicable) 8•Certification:
1313 WARD BLVD WILSON 27893 �"`1"I""'"` 04/20/22
Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date
WILSON By signing this form, I hereby certify that the ivell(s)was(were)abandoned in
County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0100 Well Construction Standards
and that a copy of this record has been provided to the tivell owner.
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details:
350 43' 10.67" 770 56' 08.76" You may use the back of this page to provide additional well site details or well
N W abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS
Attach well construction record(s)if available. For multiple injection or non-water supply
wells ONLY with the same construction/abandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#: MW-18 abandonment to the following:
Division of Water Quality,Information Processing Unit,
6b.Total well depth: 24.0 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617
10b.For Infection Wells: In addition to sending the form to the address in 10a
2.0 above,also submit one copy of this form within 30 days of completion of well
6c.Borehole diameter: (in.) abandonment to the following:
6d.Water level below ground surface: 4.0 (ft) Division of Water Quality,Underground Injection Control Program,
1636 Mail Service Center,Raleigh,NC 27699-1636
10c.For Water Supply&Infection Wells: In addition to sending the form to
6e.Outer casing length(if known): (ft.) the address(es) above, also submit one copy of this form within 30 days of
completion of well abandonment to the county health department of the county
6E Inner casing/tubing length(if known): (ft.) where abandoned.
6g.Screen length(if known): (ft.)
Form GW-30 North Carolina Department of Environment and Natural Resources-Division of Water Quality Revised March 2013