HomeMy WebLinkAboutGranville_Well Abandonment_ (10) WELL ABANDONMENT RECORD For Internal Use ONLY:
This form can be used for single or multiple wells
1.Well Contractor Information: WELL ABANDONMENT DETAILS
KENNY SARGENT i 1
7a.Number of wells being abandoned:
Well Contractor Name(or well owner personally abandoning well on his/her property) For multiple injection or non-water supply wells ONLY with the same
construction/abandonment,you can submit one form.
A - 4226
NC Well Contractor Certification Number
7b.Approximate volume of water remaining in well(s): 1'S
(gal.)
GEOLOGIC EXPLORATION,INC FOR WATER SUPPLY WELLS ONLY '
Company Name 7c.Type of disinfectant used:
2.Well Construction Permit#:
List all applicable well construction permits(i.e.County,State,Variance,etc.)ifknown
7d.Amount of disinfectant used:_ ��n.cr tss^`;t ;%c:•-..�,� lna
3.Well use(check well use):
Water Supply Well: 7e.Sealing materials used(check all that apply):
❑Agricultural ❑Municipal/Public ❑Neat Cement Grout ❑Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑Sand Cement Grout ❑Dry Clay
❑Industrial/Commercial ❑Residential Water Supply(shared) ❑Concrete Grout ❑Drill Cuttings
❑Irri ation ❑Specialty Grout ❑Gravel
Non-Water Supply Well: 171 Bentonite Slurry ❑Other(explain under 7g)
El Monitoring ❑Recovery
Injection Well: 7E For each material selected above,provide amount of materials used:
[]Aquifer Recharge ❑Groundwater Remediation 2.75 GALLONS
❑Aquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑Stormwater Drainage --
❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure:
❑Geothermal(Closed Loop) ❑Tracer ABANDONED VIA OVERDRILLING/GROUTED WITH TREMIE PIPE
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) AND BENTONITE SLURRY TO LANDFILL SUBGRADE ELEVATION
4.Date well(s)abandoned: 03/28/22
5a.Well location:
i
GRANVILLE COUNTY LANDFILL
Facility/Owner Name Facility ID#(if applicable) $•Certification: /
6584 LAND FILL ROAD OXFORD 27565 - 04/04/22
Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date
GRANVILLE By signing this form, I hereby certify that the ivell(s)was (were) abandoned in
County Parcel Identification No.(PIN) accordance with 1 SA NCAC 02C.0100 or 2C.0200 Well Construction Standards
and that a copy of this retard has been provided to the well owner.
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(ifwell field,one Iat(long is sufficient) 9.Site diagram or additional well details:
360 22' 16.49" 780 37' 03.64" You may use the back of this page to provide additional well site details or well
N W abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS
Attach well construction record(s)if available. For multiple injection or non-water supply
wells ONLY with the same constructionlabandonmem,you can submit one fornt. 10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#. P-31 abandonment to the following:
Division of Water Quality,Information Processing Unit,
6b.Total well depth: 16.5 (ft) 1617 Mail Service Center,Raleigh,NC 27699-1617
10b.For Infection Wells: In addition to sending the form to the address in 10a
2.0 above,also submit one copy of this form within 30 days of completion of well
6c.Borehole diameter: (in.) abandonment to the following:
6d.Water level below ground surface: 8.0 (ft.) Division of Water Quality,Underground Injection Control Program,
1636 Mail Service Center,Raleigh,NC 27699-1636
10c. For Water Sunniv&r Iniection Wells: In addition to sending the form to
6e.Outer casing length(if known): (ft.) the address(es) above, also submit,one copy of this form within 30 days of
completion of well abandonment to the county health department of the county
6f.Inner casing/tubing length(if known): (ft.) where abandoned.
6g.Screen length(if known): (ft.)
Form GW-30 North Carolina Department of Environment and Natural Resources-Division of Water Quality, Revised March 2013