HomeMy WebLinkAboutAlamance_Well Abandonment_ (6) WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Scott M. Werley 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only l GW 30 is needed. Indicate TOTAL NUMBER of 3344-A wells abandoned:c^e a _ E VV t 7b.Approximate volume of water remaining in wells : 1 .3 al. NC Well Contractor Certification Number PP a O (gal.) ECS Southeast, LLP MAY 3 0 2022 FOR WATER SUPPLY WELLS ONLY: Company Name �f1omm€Ttaian Pro.,.6rh'g Unit 7c.Type of disinfectant used:_ 2.Well Construction Permit#: N/A Dk-,V60G List all applicable well construction permits(i.e.UIC,County.Slate,T ariance,etc)ifknown 7d.Amount of disinfectant used:_ 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public 9 Neat Cement Grout a Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings ❑Irri ation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g) C Monitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑GroundwaterRetmediation Bentonite- 25 Ibs ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑StonnwaterDrainage Neat cement - 40 Ibs ❑Experimental Technology ❑Subsidence Control , 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Gravity feed bentonite chips from 24.5-5' bgs Pour neat cement from 5' bgs to ground surface 4.Date well(s)abandoned: 5/4/2022 5a.Well location: Former Express 552 0-023879 Facility/Owner Name Facility ID#(if applicable) 8.Certification: 1845 North Church Street Q5.19.2022 Physical Address,City,and Zip Signature of Certi 1 d ell Contractor or Well Owner Date Burlington rang 0 139749 By signing this firm, I hereby certi y that the well(s) was were abandoned in County Parcel Identification No.(PIN) accordance ivith 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the ivell owner. Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lat/long is sufficient) 9.Site diagram or additional well details: 36.095071 N -79.406368 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction?record(s)ifavailable. Fornudtiple infection ornon-natersapply ivells ONLY with the scone construction/abandonment,you can submit one form. n A 10a. For All Wells: Submit this fornm within 30 days of completion of well 6a.Well ID#: 'V I W-1 5 abandonment to the following: Division of Water Resources,Information Processing Unit, fib.Total well depth 24.5 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Iniection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 6.25 (in.) above, also submit one copy of this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 16.77 A) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service-Center,Raleigh,NC 27699-1636 NSA 10c.For Water Supply&Iniection Wells: In addition to sending the form to the 6e.Outer casing length(if known): (ft.) address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): 9.5 (ft.) abandoned. i 6g.Screen length(if known): 15 Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016