Loading...
HomeMy WebLinkAbout20220712 Ver 1_Riparian Buffer Authorization Request_20220523Buffer Authorization Application Form 15A NCAC 02B .0233 (8)(b), .0243 (8)(b), .0250 (11)(b), .0259 (8)(b), .0267 (11)(c), .0607 (e)(2) Buffer Authorization Online Form - Update 10/23/2018 Original Submittal 5/23/2022 A. Owner/Applicant Information General Information Primary Contact Email: * Who is submitting the application?* 1. Property Owner Information: .......................................................................................... la. Name on Recorded Deed:* 1b. Responsible Party: lc. Mailing Address:* Id. Telephone:* 7047064277 3. Agent Information: 3a. Name: 3b. Company Affiliation: chris@archrsyalis.com Please list the contact person's email for questions or payment on this project if needed. Owner Applicant other than Owner Agent JD Partners Group Doug Trimmer (for Corporations) Street Address 8274 Golf Ridge Drive Address Line 2 City State / Province / Region Charlotte NC Postal / Zip Code Country 28277-8869 US 3c. Mailing Address: Street Address Address Line 2 City Postal / Zip Code 3d. Telephone: 3f. Attach a signed and dated copy of the agent authorization form. 1e. Email Address:* dougtrimmer@hotmail.com State / Province / Region Country 3e. Email Address: Click the upload button or drag and drop files here to attach document PDF Only B. Project Information and Prior Project History 1. Project Information la. Name of Project: * Sadler (Subdivision, facility, or establishment name) 3600Sadler_001 - survey.pdf PDF only 1b. Is this a publicly -funded transportation project?* Yes No Id. Subdivision Name: Steele Creek 1e. Nearest Municipality: Mecklenburg County -unincorporated If. Property Size: 0.60 acres lg. County (or Counties) where the project is located:* Mecklenburg lh. Property ID# 11327105 Tax PIN or Parcel id Deed Information Date of Purchase 8/10/2021 Type of Book Deed Book# Page# Map L15 SEC36 M18-42 1 j. Attach a copy of the recorded map that indicates when the lot was last platted. Click the upload button or drag and drop files here to attach document 1.16MB 1k. How would you like to provide the Latitude and Longitude information?* • Address Lookup Manually Address Lookup Latitude * 35.2001157 Street Address 3600 Sadler Road Address Line 2 City State / Province / Region Charlotte NC Postal / Zip Code Country 28278-9677 US Longitude* -81.0014594 11. Is the project located in any of North Carolina's twenty coastal counties?* Yes • No 2. Surface Waters 2a. Name of the nearest body of water to proposed project:* Catawba River 2b. Water Quality Classification of nearest receiving water: * Catawba River 2c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 195 (linear feet only) 3. Project Description: 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: The current and proposed use of the property is a single family home. Properties along Sadler Road are also single family home. The property slopes from the road down to the Catawba River. 3b. Attach an 8'/2 x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site. Click the upload button or drag and drop files here to attach document Map2-GIS.pdf 505.16KB PDF only 3c. Attach an 8'/: x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site. Click the upload button or drag and drop files here to attach document Map1 - GIS.pdf PDF only 4. Proposed Activity 129.17KB Provide a detailed description of the proposed activity including its purpose and include the type of equipment to be used: * The project is a renovation and minor extension to existing decks at the rear of the existing home. Attach a site plan as applicable to the project: Click the upload button or drag and drop files here to attach document 0100_EXISTING AND PROPOSED.pdf 0100_EXISTING.pdf 0100_PROPOSED.pdf 0100_3600 Sadler Road_(Sealed).pdf PDF only 5. Jurisdictional Determinations 241.24KB 235.3KB 241.58KB 2.91 M B 5a. Have jurisdictional wetlands or stream determinations by the Corps or State been requested or obtained for this property/project (including all prior phases) in the past?* Yes ® No 6. Project History 6a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past?* • Yes No 6b. List any permits/approvals that have been requested or obtained for this project in the past. Application Date Date Issued Permit Type Building Permit 6c. Please explain and detail according to "help file" instructions. * The building permit number for the project is B41139563 7. Future Project Plans 7a. Is this project a phased project?* C. Proposed Impacts Inventory Buffer Impacts O Yes O No Project is in which protected Basin?* Neuse River Basin (15A NCAC 02B.0233) • Catawba River Basin (15A NCAC 02B.0243) Randleman Lake Watershed (15A NCAC 02B.0250) Tar -Pamlico River Basin (15A NCAC 02B.0259) Jordan Lake Watershed (15A NCAC 02B.0267) Goose Creek Watershed (15A NCAC 02B.0606 & 15A NCAC 026.0607) Individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. Site# - Reason Stream Name Buffer Impact* Impact Type Zone 1 Zone 2 Renvation of existing decks Map label (e.g. Road Crossing 1) Catawba River Permanent (P) Perm or Temp Allowable w/ mitigation 0.00 Square Feet 0.00 Square Feet Total Zone 1 Impacts: 0.00 Total Zone 2 Impacts: 0.00 Total Buffer Impacts: 0.00 Comments: D. Impact Justification and Mitigation 1. Avoidance and Minimization la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project. The renovations where considered for minimal expansion and disturbance of the buffer while still allowing the home and circulation to be functional. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. The renovations where considered for minimal expansion and disturbance of the buffer while still allowing the home and circulation to be functional. 2. Buffer Mitigation 2a. The table below identifies the square footage of impact to each zone of the riparian buffer and the required mitigation. Zone 1 - Catawba Only Total Impact Multiplier Required Mitigation 0.00 Square Feet 2 0.00 Square Feet Zone 2 Total Impact Multiplier Required Mitigation 0.00 Square Feet 1.50 0.00 Square Feet 2b. What is the mitigation plan proposed for this Payment to private mitigation bank project?* Payment to Division of Mitigation (DMS) Permittee responsible mitigation 2c. Provide a description of your mitigation plan. * Simple mitigation is suggested to convert the grassed area as shown to a natural cover (mulch/pine straw), then plant low maintenance "native species" shrubs/vegetation 2d. Attach a detailed planting plan to include plant type, date of plantings, the date of the one-time fertilization in the protected riparian buffers, and a plan sheet showing the proposed location of the plantings.* Click the upload button or drag and drop files here to attach document bufferl .pdf 267.75KB buffer2.pdf 78.52KB PDF only 2g. Comments: E. Diffuse Flow Plan la. What type of SCM are you providing?* Level Spreader Vegetated Conveyance (lower SHWT) Wetland Swale (higher SHWT) Proposed project will not create concentrated stormwater flow through the buffer Other SCM that removed minimum of 30% nitrogen lc. Diffuse Flow Documentation F. Supplementary Information Environmental Documentation Click the upload button or drag and drop files here to attach document bufferl.pdf 267.75KB buffer2.pdf 78.52KB PDF only la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? Yes No Violations 2a. Is the site in violation of DWR Wetland Rules (15A NCAC 02H .0500), Isolated Wetland Rules (15A NCAC 02H .1300), DWR Surface Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 02B .0200)? Yes No 2b. Is this an after -the -fact buffer authorization application? Yes No G. Additional Information Please upload any additional information you would like the Division to consider during application review. Additional Attachments: Additional Comments: H. Sign and Submit By digitally signing below, I certify that: Click the upload button or drag and drop files here to attach document PDF only ▪ I have given true, accurate, and complete information on this form; o I agree that submission of this form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act") • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); o I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND o I intend to electronically sign and submit the application form." Print Name: * Christopher Webb Signature Submission Date: 05.23.2022 (Auto populated field) Initial Review Is this accepted into the review process?* • Yes No Yes • No ID#* 20220712 Version:* 1 Select Reviewer: * Doug Perez:eads\djperez Select Reviewing Office* Mooresville Regional Office - (704) 663-1699 Is this project a public transportation project?* Has payment been received?* • No Payment Needed Fee Received Need Fee - send electronic notification w a m 73 c. 3600 Sadler Rd, Charlotte, NC 28278 cr a3 co %.5' 00.2 Sadler Rd et 430, Sadler Rd SadJ0rR cif el 0 Sa Sad‘el likd Fox Valley Rd Fox Valley Rd Fox Valley Rd o` Go ale Q / ' ' ( 1. 1 \ 1 \\\, . „.\.. ,... ,.„,.../„.,../..,,....„,../„.„.„.„.„)../../.„.,,,,,,r/..,„/„....77.r,../.. .,7„..„,./.. / . ,L „, !/i!„,./ // ,, , . . %%1///7,'///. . . . ... . .. .. `f////////////////////////r .c, .. . w ... . ,/ / • / .i. f... . . . . . . . . ,,., 4 t r ro . ,A Western Catawba s + ' A; RC District LOWER LAKE WYLIE . , . / • D ,. WATERSHED CA 4 l' a % k 1 11 II �4 I j k i I. I i 4 } ti iI NOTES IRON PINS ON ALL CORNERS UNLESS OTHERWISE NOTED AREAS WERE CALCULATED BY COORDINATE METHOD. NO NCGS TRAVERSE WAS FOUND TO BE WITHIN 2000' THIS PROPERTY SUBJECT TO ANY OTHER EASEMENTS, AGREEMENTS, OR RIGHTS —OF —WAY OF RECORD. THIS PROPERTY MAY BE SUBJECT TO WETLANDS REGULATIONS. INDIVIDUAL PROPERTY OWNERS NEED TO REVIEW CURRENT GOVERNMENTAL REGULATIONS PRIOR TO CONSTRUCTION MONUMENT EASEMENTS, COMMON OPEN SPACE, MEDIANISLANDS, LANDSCAPE EASEMENTS AND SIDEWALKS SHALL BE MAINTAINED AND DEDICATED BY THE HOMEOWNER'S ASSOCIATION. STORM SEWER PIPE SYSTEMS AND/OR CHANNELS LOCATED WITHIN LANDSCAPE AND DRAINAGE EASEMENTS (LSE) ARE THE MAINTENANCE RESPONSIBILITY OF THE HOMEOWNER'S ASSOCIATION. THIS PROPERTY DOES LIE WITHIN A FEMA FLOODPLAIN PER FEMA FIRM PANEL 3710450300M, DATED 09-02-2015. THIS PROPERTY LIES WITHIN THE WESTERN CATAWBA POST CONSTRUCTION DISTRICT. THERE ARE NO POST CONSTRUCTION BUFFERS ON THIS PROPERTY. THIS PROPERTY LIES WITHIN THE BEAVERDAM CREEK WATERSHED. THIS PROPERTY LIES WITHIN THE LOWER LAKE WYLIE WATERSHED CRITICAL AREA. THERE IS A WATER QUALITY BUFFER ON THIS PROPERTY. 703'L' NOW OR FORMERLY CLARENCE DAVID MOSS & MARIA VIRGINIA MOSS DEED:26790-1 570' CONTOUR LINE I4K mug FLOOD FRINGE BOUNDARY LINE FEMA FLOOD PANEL #3710450300M FLOATING DOCK z F W 0 0 STONE ,4? v co oen z BaRoNARY 'I state that this map was drown under my supervision from an actual survey made under my supervision (map description recorded in Book 26790, page 1); that the boundaries not surveyed are indicated as drawn from information in MAP Book 18, page 42; that the ratio of precision or positional accuracy is IN EXCESS OF 1:10,000; and that this map meets the requirements of The Standards of Practice for Land Surveying in North Carolina (21 NCAC 56. 1600)." This 07 day of JULY, 2021. GRAPHIC SCALE 50 0 25 50 BEARINGS BASED ON NC GRID (NAD 83) SADLER ROAD eh IF VICINITY MAP NO SCALE PO16 WE PROJECT INFORMATION ZONING — R-5 MIN. FRONT SETBACK 20' MIN. SIDEYARD 5' MIN. CORNER SIDEYARD 10' MIN. REARYARD 35' MIN. LOT WIDTH 50' MIN. LOT SIZE 6,000 SF 'REFER TO ZONING ORDINANCE FOR POSSIBLE ADJUSTMENTS TO THESE MINIMUM DIMENSIONS. CROSS SECTION 750 ELEVATION 571.9 LOT 16 CRESCENT LAND & TIMBER RECREATION LOTS SECTION 38 MB:18-42 NOW OR FORMERLY BRENDA ANN PORTER LEWIS & STEPHEN H. LEWIS DEED:33970-29 100 N87' 6'45" ABTAT. ,,N1 O . O rn• O 00 E 95.14 CENT LAND & TIMBER RECREATION LOTS 'Iw SECTION 36 11a MB:18-42 NOW OR FORMERLYI RHETT L. BROWN & CARL BENSON 1 DEED:35091-373 1 w LEGEND BOC — BACK OF CURB CO — CLEAN OUT COS — COMMON OPEN SPACE CP — CABLE PEDESTAL CONC. — CONCRETE ELEV — ELEVATION EOP — EDGE OF PAVEMENT EX. — EXISTING LP — LIGHT POLE LSE — LANDSCAPE EASEMENT MB. — MAP BOOK PSE — PUBLIC STORM DRAINAGE EASEMENT PUE — PUBLIC UTILITIES EASEMENT R/W — RIGHT OF WAY SF— SQUARE FEET TP — TELEPHONE PEDESTAL WM — WATER METER V I 012I t4 m NOW OR FORMERLY a I CRESCENT RIVER DISTRICT LLC ' DEED:35878-75 efl W ' I PHYSICAL SURVEY FOR TRIMMER SCALE TOWNSHIP COUNTY STATE DATE 1" = 50' BERRYHILL MECK N.C. 07/07/21 3600 SADLER ROAD LOT 15, SECTION 36 OF RECREATION LOTS SURVEYED YAI aouGs-Wnueas t Hour., Ixc. Planning a Surveying e Lige Megrims .a.: oe Court IL Clarice , North Caches. 99219 Phrao, North (broths. 1134 794.99911110 704.661.015060a) MAP RECORDED 1 inch = 50 ft. KC Corporate Reekdh.tio. gC-0479 18-42 DEED RECORDED ` W ,..,•',.; ...r;e-'0,':;... • 0,. 4-k , !'. tr'' ="'K, . , 9 '9,.• 'F'-` aTtit4 A ' .... . ,,..9",,,; ., 1 . " I' ' . I. 4 i'lman4fL,':,• .• ...y....!1.--•....,••-•-- .. - o. t.„g .. ,--,v, ; ..,..t._ •--- ---- ..:14. '''''.11!*:.' . '•:..*AT:--1:' ''''e'------- —---- i ._- :-' -- __,.. .,...,_____..,...."-- - __________1,,..--t v • , .. . ., - , ...,,,:*.0 11 ' .S.•. 4,r4-xl• - - ; ' .s. ,...... .. • •-r. 4.. : 111110-11 ilii Nil- Hinimi . - ) NI, •-, .': III 1 r -E r I 4. ,`"...1. , —-.. ' 1:11:111 ' ''..::;.•;:.;:;:;: :4: 4.1 ******II• I tf: I I':1":'..G4.4:••••••04:: ::' , • _,. I . m r . . , : ,.,.., , - . . • , , 1 ,ptle .. wielr 91 /f • 9, . . 1 '4111111 r... , ...._ .... • _ .._ . ... r— • r.. 9114, 0 1991., • —...... ....">.'"''.1.-- • 411111111 ' -'-.,-"-)egi 1 I • a • LAKEr&horeline ` W ,..,•',.; ...r;e-'0,':;... • 0,. 4-k , !'. tr'' ="'K, . , 9 '9,.• 'F'-` aTtit4 A ' .... . ,,..9",,,; ., 1 . " I' ' . I. 4 i'lman4fL,':,• .• ...y....!1.--•....,••-•-- .. - o. t.„g .. ,--,v, ; ..,..t._ •--- ---- ..:14. '''''.11!*:.' . '•:..*AT:--1:' ''''e'------- —---- i ._- :-' -- __,.. .,...,_____..,...."-- - __________1,,..--t v • , .. . ., - , ...,,,:*.0 11 ' .S.•. 4,r4-xl• - - ; ' .s. ,...... .. • •-r. 4.. : 111110-11 ilii Nil- Hinimi . - ) NI, •-, .': III 1 r -E r I 4. ,`"...1. , —-.. ' 1:11:111 ' ''..::;.•;:.;:;:;: :4: 4.1 ******II• I tf: I I':1":'..G4.4:••••••04:: ::' , • _,. I . m r . . , : ,.,.., , - . . • , , 1 ,ptle .. wielr 91 /f • 9, . . 1 '4111111 r... , ...._ .... • _ .._ . ... r— • r.. 9114, 0 1991., • —...... ....">.'"''.1.-- • 411111111 ' -'-.,-"-)egi 1 I • a • LAKEr&horeline FLOOD FRINGE BOUNDARY LINE FEMA FLOOD PANEL #3710450300M LAKE WYLIE (E) STONE WALL (E) LAMP POST 570 CONTOUR LINE PROPERTY BOUNDRY (E) STAIR (E) UNCOVERED WOOD DECK NEW UNCOVERED WOOD DECK (E) WOOD WALK (E) WOOD WALK NEW STAIR (E) STAIR NEW LANDING \(E) RAILING \ \ \ \ NEW STAIR \ \ PROPOSED FLOOR PLAN NEW SCALE: 8" = 1'-0" EXISTING (TO BE REMOVED) FLOOD FRINGE BOUNDARY LINE FEMA FLOOD PANEL #3710450300M LAKE WYLIE (E) STONE WALL (E) LAMP POST 570 CONTOUR LINE PROPERTY BOUNDRY (E) STAIR (E) UNCOVERED WOOD DECK (E) WOOD WALK (E) STAIR \(E) RAILING \ \ EXISTING FLOOR PLAN SCALE: 8" = \ NEW STAIR \ FLOOD FRINGE BOUNDARY LINE FEMA FLOOD PANEL #3710450300M LAKE WYLIE (E) STONE WALL (E) LAMP POST 570 CONTOUR LINE PROPERTY BOUNDRY NEW UNCOVERED WOOD DECK (E) WOOD WALK NEW LANDING \(E) RAILING \ \ NEW STAIR PROPOSED FLOOR PLAN SCALE: 8" = 2.88 5 7 0' C \ TO �. R \ _ - LAKE �l YT ,I�" FLOOD R \ G _ 8 0 �. \ 3 A R Y L I \ C \ / C = V A L O O D D A \ #3 7 10 L 5 0 3 0 0 V S TO \ WALL H DOCKG WOOD WAL'< RAMP S TA TI 0 Nl A 30C/C 9 z J DECK E STEPS LP C Y CA Ul zi D D U L0'I' 24,035 ®. 552 STEPS 29 �� ��� _ � I I I CTI O ill 5 SF C. WO FENCE �l \ \ #3 2 EAfV PROPOSED COVERED PORCH _ I D I I 27 O C E \ \ 6 S WOODI I S I \ \ 9/ \ \ O TO Y E I }, fV ECH L OH-E WALL STEPS ■11111111111 5' S /- - - / / / \\ C 0 (E)C0\C. WALK 15' I O/�E SID=YARD WELL o - - GAVEL PA�KI\G \ C E DRIVE / / / I IV P TA -- I I TE / / / I C 0\ WALK OVA3LE 0 P A \ \ 'C P A 56.37' -\ U IQ co I W I U) 0 I [r) L 1 I I i WELL A T8c T+ 0 X / / / / / / I CL / o / / / / I I I I 1 I I I / \ I SADLER GENERAL NOTES DRAWING INDEX 1. DO NOT SCALE DRAWINGS. GC SHALL NOTIFY ARCHITECT IN WRITING IMMEDIATELY OF ANY DIMENSION DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS 2. THESE DOCUMENTS ARE THE PROPERTY OF THE DESIGNER AND SHALL NOT BE USED WITHOUT WRITTEN CONSENT. 3. ALL DIMENSIONS ARE TO FACE OF FINISH OR FACE OF MASONRY. GENERAL CONTRACTOR IS TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND SHALL COMPLY WITH ALL APPLICABLE NATIONS, STATE, AND LOCAL BUILDING CODES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSURE COMPLIANCE WITH SAID CODES. 5. THE DESIGNER, OWNER, AND THE PROFESSIONAL CONSULTANTS ARE NOT RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES, OR FOR SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK ON THIS PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF TH WORK ON THIS SITE. 6. THE GENERAL CONTRACTOR SHALL ABIDE BY LOCAL AREA STANDARDS AND RELATED OSHA STANDARDS FOR THE SAFETY OF THEIR EMPLOYEES ON SITE. THE DESIGNER AND PROFESSIONAL CONSULTANTS WILL BE HELD HARMLESS BY THE OWNER,GENREAL CONTRACTOR, AND RELATED AWARDED TRADES ON THIS PROJECT FOR ACCIDENTS OF INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING THE CONSTRUCTION PHASES OF THIS PROJECT. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL SAFETY PRECAUTIONS OR SAFETY PROGRAMS USED TO PROVIDE A SAFE WORKING ENVIRONMENT ON THE JOB SITE. THE CONTRACTOR SHALL MAINTAIN AT ALL TIMES ADEQUATE SAFETY BARRICADES AND CLEAR ACCESS IN AND OUT OF THE WORK SITE SO AS TO FACILITATE DAILY TRAFFIC MOVEMENT, DELIVERIES, AND SAFETY. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL STRUCTURAL SHORING AND BRACING DURING CONSTRUCTION. 9. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. CONTRACTOR TO VERIFTY AND COORDINATE LOCATIONS OF DRAFTSTOPPING AND FIRE EXTINGUISHERS WITH LOCAL FIRE CODE OFFICIAL, WHEN NECESSARY. 10. PRIOR TO SUBMITTING A BID, CONTRACTOR AND SUBCONTRACTORS, SHALL VISIT THE JOB SITE AND NOTIFY OWNER AND DESIGNER OF ANY CONDITIONS NOT INCLUDED IN THESE DOCUMENTS WHICH REQUIRE CORRECTIVE OR ADDITIONAL ACTIONS. NO CHANGES TO PLANS TO BE MADE WITHOUT WRITTEN APPROVAL BY THE DESIGNER / ENGINEER. 11. THE GENERAL CONTRACTOR SHALL SUPPLY EACH SUBCONTRACTOR ADEQUATE DOCUMENTS IN ORDER FOR THE SUBCONTRACTOR TO ACCURATELY PRICE AND PERFORM THEIR WORK. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ERRORS AND OMISSIONS CAUSED BY THE LACK OF ACCESS TO ADEQUATE DRAWINGS FOR THE SUBCONTRACTOR TO COMPLETE THEIR SCOPE OF WORK. 12. NO SUBSTITUTIONS OF ANY KIND FOR MATERIALS SPECIFIED ON THESE CONSTRUCTION DOCUMENTS IS ALLOWED UNLESS NOTED OTHERWISE. NO "EQUIVILENT" SUSTITUTIONS WILL BE MADE UNLESS APPROVED IN WRITING BY THE DESIGNER AND/OR OWNER FOR ANY REASON. 13. THE GENERAL CONTRACTOR IS RESPONSIBLE TO INSTALL ALL SYSTEMS IN THE ORDER REQUIRED TO AVOID CONFLICTS. 14. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL PROVIDE A CERTIFICATE OF INSURANCE TO THE OWNER PRIOR TO STARTING ANY WORK ON THIS PROJECT. CERTIFICATE OF INSURANCE CANNOT BE TERMINATED OR CANCELED WITHOUT 10 DAYS PRIOR WRITTEN NOTICE TO THE OWNER. 15. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ALL REQUIRED PERMITS. APPROVALS, AND FINAL CERTIFICATE OF OCCUPANCY. NO CONSTRUCTION OR FABRICATION SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED ALL PLANS AND OTHER DOCUMENTS APPROVED BY ALL PERMITTING AUTHORITIES. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL VERIFY SERVICE WITH UTILITY AGENCIES AND SCHEDULE ON SITE INSTALLATIONS AND INSPECTIONS. 16. ALL MATERIALS, SUPPLIES, AND EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND PER APPLICABLE CODES AND REQUIREMENTS. 17. THE GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BRACING, BLOCKING, AND SHORING TO INSURE STRUCTURAL STABILITY OF THE BUILDING AND ALL RELATED BUILDING COMPONENTS, I.E., STRUCTURAL WALLS, INTERIOR WALL ASSEMBLIES, FIXTURES,...ETC, DURING THE CONSTRUCTION PHASE OF THIS PROJECT. IT WILL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SUBCONTRACTORS TO PROVIDE BLOCKING AS NEEDED FOR ALL INSTALLATIONS AND IT IS NOT THE RESPONSIBILITY OF THESE CONSTRUCTION DOCUMENTS TO INDICATE EVERY SPECIFIC CONDITION IN NEED OF BLOCKING. 18. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES BOTH UNDER THE GENERAL CONTRACTOR'S CONTRACT AND THOSE HIRED DIRECTLY BY THE OWNER IN ORDER TO COORDINATE UTILITIES AND AVOID INTERFERENCE AND OMISSIONS. EACH CONTRACTOR WILL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED BY CODE AND NEEDED TO COMPLETE THIS WORK. 19. ALL MATERIALS USED WILL BE NEW AND BEAR UL CABLES WHERE REQUIRED AND MEET APPROPRIATE N.E.M.A. STANDARDS. 20. EXCEPT WHERE OTHERWISE SPECIFIED, THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROVIDE PROTECTION AGAINST WEATHER TO MAINTAIN ALL WORK, MATERIALS, APPARATUS, AND FIXTURES FROM INJURY OR DAMAGES. AT THE END OF THE DAY'S WORK, ALL NEW WORK LIKELY TO BE DAMAGED SHALL BE COVERED OR OTHERWISE PROTECTED AS REQUIRED. 21. MATERIALS STORED ON SITE SHALL BE PROTECTED FROM DAMAGE BY MOISTURE, WIND, SUN ABUSE, OR ANY OTHER HARMFUL EFFECTS. 22. ALL WORK TO BE FIRST RATE, HIGH QUALITY, AND ACCOMPLISHED IN A WORKMANLIKE MANNER BY SKILLED CRAFTSMAN USING ACCEPTED PRACTICES AND METHODS APPROPRIATE TO THE TRADE INVOLVED. 23. EACH CONTRACTOR IS RESPONSIBLE FOR FIRST CLASS WORKMANSHIP AND WILL ASSUME ALL RESPONSIBILITY FOR THE CARE AND PROTECTION OF HIS OWN WORK AND MATERIALS FROM DAMAGE. EACH SUBCONTRACTOR WILL REPAIR ANY DAMAGETO HIS OWN OR OTHER WORK CAUSED BY HIMSELF OR THOSE EMPLOYED BY HIM. 24. ALL GENERAL AND SUBCONTRACTORS WILL DELIVER TO THE OWNER, A COMPLETE RELEASE OF ALL LIENS ARISING OUT OF THIS CONTRACT AND/OR RECEIPTS IN FULL LIEU THEREOF TOWARDS THEIR PARTIAL OR FINAL PAYMENT FOR WORK IN PLACE FOR THE OWNERS. 25. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL DEBRIS ACCUMULATED BY EACH TRADE AND/OR SUBCONTRACTOR. 26. WHEN ALL WORK IS COMPLETED, THE GENERAL CONTRACTOR SHALL EMPLOY THE SERVICES OF A CLEANING SERVICE TO CLEAN AND WASH DOWN ALL INSTALLED EQUIPMENT, SERVICE AREAS, ALONG WITH THE CLEANING OF ALL GLASS WINDOWS AND DOORS. COMPLETED WORK TO BE BROOM CLEAN. 27. THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN ONE COMPLETE SET OF PRINTS OF ALL WORKING DRAWINGS. ON THIS SET, GENERAL CONTRACTOR SHALL PRINT IN PENCIL, NEATLY AND ACCURATELY ANY CHANGES IN THE LOCATION AND TYPES OF PARTITIONS, WALLS, ELECTRICAL, MECHANICAL SERVICES, AND EQUIPMENT. THIS SET OF PRINTS SHALL BE PRESENTED TO THE OWNER AT THE TIME OF FINAL COMPLETITION OF THE WORK BY THE OWNER. 28. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVING HIS OWN TELEPHONE, TOILET, WATER, AND ELECTRICITY FOR ALL PROJECT FUNCTIONS. 29. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ALL TAPS, EXTENSIONS, VALVES, OR OTHER DEVICES NECESSARY TO RUN POWER TOOLS AND EQUIPMENT. SUCH MODIFICATIONS TO EXISTING UTILITIES MUST BE REMOVED AT COMPLETITION OF THE PROJECT. 30. THE GENERAL CONTRACTOR SHALL LIMIT THE INGRESS AND EGRESS OF MEAN AND EQUIPMENT OT THE CONSTRUCTION SITE TO AUTHORIZED PERSONS ONLY. DAMAGE TO ANY EXISTING INTERIOR OR EXTERIOR CONSTRUCTION SHALL BE REPAIRED TO "LIKE NEW" CONDITION UNDER THIS CONTRACT. 31. ARCHITECTURAL PLANS EX. ELEVATIONS PLANS / SCHEDULES EX. ELEVATIONS NOTES PLAN LEVEL FRAMING PLAN LEVE L PLAN PLAN DETAILS T.01 TITLE SHEET AD.1 0 DEMOLITION AD.40 DEMOLITION A2.01 PROPOSED A4.01 PROPOSED STRUCTURAL SO GENERAL S 1 FOUNDATION S2 BASEMENT S3 MAIN / UPPER FRAMING S4 ROOF FRAMING S5 STRUCTURAL H E \, \ AI C (� /CO / C E TE / N 3 X E D / / P P G W TP C CI)U l m _I / 1 � / I Z 7j I CIDX I / I / / I / / l / / 5' S Y ° Lu I C P Li] 0 SITE PLAN ABBREVIATIONS PROFESSIONALS PROJECT DATA CODE REVIEW PROJECT NOTES SYMBOLS @p AT HB HOSE BIBB UNO UNLESS NOTED q CENTER LINE HP HORSE POWER OTHERWISE d PENNY HR HOUR VCT VINYL COMP. 0# POUND HTR HEATER TILE L PERPENDICULAR HVAC HEATING/VENTI- VERT VERTICAL ANGLE LATING/ A/C VGDF VERTICAL GRAIN AB ANCHOR BOLT HW (R) HOT WATER (RETURN) DOUGLAS FIR AC ASPHALTIC CONCRETE INV INVERT VTR VENT THRU ROOF A/C AIR CONDITIONING LAM LAMINATE(D) W WEST ALUM ALUMINUM LAV LAVATORY WC WATER CLOSET ANOD ANODIZED LB LAG BOLT WH WATER HEATER BD BOARD LC LAUNDRY CHUTE WP WATERPROOF BLDG BUILDING LT LIGHT WS WOOD SCREW BLK(G) BLOCK(ING) MAS MASONRY OR WATER BN BOUNDARY NAILING MATL MATERIAL SOFTENER BOT BOTTOM MAX MAXIMUM WWF WELDED WIRE CB CATCH BASIN MB MACHINE BOLT FABRIC CI CAST IRON MECH MECHANICAL W/ WITH CJ CEILING JOIST MEMB MEMBRANE W/O WITHOUT CLG CEILING MTL METAL CLR CLEAR MFR MANUFACTURER CMU CONCRETE MASONRY MIN MINIMUM UNIT MISC MISCELLANEOUS CO CLEAN OUT N NORTH COL COLUMN (N) NEW CONT CONTINUOUS NIC NOT IN CONTRACT CSK COUNTERSINK NO / # NUMBER DF DOUGLAS FIR NTS NOT TO SCALE DIA DIAMETER OC ON CENTER DN DOWN OH OVAL HEAD OR DS DOWNSPOUT OVER HEAD DWG DRAWING OPNG OPENING E EAST PL PLATE OR PROP. LINE (E) EXISTING PLAM PLASTIC LAMINATE EA EACH PLAS PLASTER EJ EXPANSION JOINT PLYWD PLYWOOD ELEV ELEVATION P PAINT (NUMBER SEE SPECS) EN EDGE NAIL PR PAIR EQ EQUAL PTDF PRESSURE -TREATED EQUIP EQUIPMENT DOUGLAS FIR FAO FORCED AIR UNIT RH ROOF DRAIN FBO FURNISHED BY OWNER RH ROUND HEAD OR OTHERS, TO BE RM ROOM INSTALLED BY ROUGH OPENING CONTRACTOR RWD REDWOOD FD FLOOR DRAIN SCHED SCHEDULE(D) FE(C) FIRE EXTING.(+ CABINET) S SOUTH FF FINISHED FLOOR SCH SCHEDULE FG FINISHED GRADE SHTNG SHEATHING FH FLAT HEAD SIM SIMILAR FIN FINISH SMACNARE: THE ARCH SHEET FL FLOW LEVEL METAL MANUAL FLG FLASHING SPEC SPECIFICATION FLR FLOOR SQ SQUARE FN FIELD NAILING SSTL STAINLESS STEEL FOC FACE OF CONCRETE STD STANDARD FOF FACE OF FINISH STL STEEL FOM FACE OF MASONRY TC TOP OF CURB OR FOP FACE OF PLYWOOD TOP OF CONCRETE FOS FACE OF STUD TCB TOP OF CATCH BASIN FT FOOT OR FEET T&G TONGUE AND GROOVE GA GAUGE TP TOP OF PAVING GALV GALVANIZED TOW TOP OF WALL GWB GYPSUM WALL BOARD TYP TYPICAL ARCHITECTURAL DESIGNER: ARCHRYSALIS 309 GREYSTONE ROAD CHARLOTTE NC 28209 704.807.2877 CONTACT: CHRISTOPHER WEBB STRUCTURAL ENGINEER: INTELLIGENT DESIGN ENGINEERING 1945 J N PEASE PLACE SUITE #204 CHARLOTTE NC 28262 704.604.9475 / 704.335.7200 CONTACT: CORBIN HOFFMAN SURVEYOR: YARBROUGH-WILLIAMS & HOULE, INC. PO BOX 1196 PINEVILLE NC 28134 740.556.1990 CONTACT: OWNER: PROJECT ADDRESS: P.I.D. NUMBER: OCCUPANCY GROUP: CONSTRUCTION TYPE: LOT: MAPBOOK: APPLICABLE CODES FRONT SETBACK: SIDE SETBACK: REAR SETBACK: MAXIMUM HEIGHT: LOWER LAKE WYLIE WATERSHED PROJECT DESCRIPTION R V 15 18 AND FRONT PORCH AC) ADDITION DECKS = 1,787 167 SQ' JD PARTNERS GROUP LLC 8274 GOLF RIDGE DR CHARLOTTE NC 28277 3600 SADLER ROAD CHARLOTTE NC 28208 11327105 USE: SFR ZONE: R5 SECTION: 36 OF RECREATION LOTS PAGE: 42 2018 NCRC, 2018 NCPC, 2018 NCMC, 2018 NEC 20'-0" 5' 0" 35' 0" 40'-0" ADDITION TO EXISTING SINGLE FAMILY = 135 SQ' SQ' ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ANY MODIFCATIONS TO THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES SHALL BE AT THE EXPENSE OF THE OWNER, SUBJECT TO THE RECEIPT OF AN AFFIDAVIT OR LETTER FROM THE GOVERNING BODY AND OWNER'S PRIOR APPROVAL OF ANY ADDITIONAL COST TO BE INCURRED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. 1. THESE DRAWINGS ARE SCOPE DOCUMENTS INDICATING THE GENERAL PROJECT DESIGN CONCEPT, DIMENSIONS OF THE PROJECT, MAJOR ARCHITECTURAL ELEMENTS, AND BASIC ORGANIZATION OF STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS. 2. AS SCOPE DOCUMENTS, THESE DRAWINGS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL MATERIALS OR WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE PROJECT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE PROPOSED PROJECT. THE OWNER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR(S) TO EXECUTE NECESSARY WORK AND SUPPLY REQUIRED MATERIALS FOR PROPER COMPLETION OF THIS PROJECT, AND MAKES NOT WARRANTY SAID OR IMPLIED ON THESE CONSTRUCTION DOCUMENTS. 3. THE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY BUILD THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE GENERAL CONTRACTOR OF THIS JOB PRIOR TO CONSTRUCTION. ANY ERRORS OR OMISSIONS, IF FOUND, SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. THE OWNER AND CONTRACTOR WILL BE RESPONSIBLE FOR ANY MECHANICAL, ELECTRICAL, OR STRUCTURAL; IF NEEDED. PRIOR THE START OF CONSTRUCTION, ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES &RESTRICTIONS, SHALL TAKE PRECEDENCE OVER ANY PART OF THESE PLANS BUT MUST FIRST BE BROUGHT TO THE ATTENTION OF THE OWNER. THE OWNER IS NOT RESPONSIBLE FOR ANY STRUCTURAL, CONSTRUCTION, FABRICATION, ELECTRICAL, PLUMBING, MECHANICAL, CIVIL, OR LANDSCAPING FAILURES CONCERNING THIS PROJECT. 4. THE GENERAL CONTRACTOR TO PROVIDE CARBON MONOXIDE ALARMS IN ACCORDANCE WITH SECTION 315.1 5. THE GENERAL CONTRACTOR TO PROVIDE SMOKE ALARMS AS REQUIRED FOR NEW DWELLING. THE SMOKE ALARMS SHALL BE INTERCONNECTED AND HARDWIRED. +4_ DATUM POINT, WORK POINT 0 WINDOW TYPE O O DOOR TYPE 1 4 2 AX.XX 3 INTERIOR (DRAWING SHEET SECTION (DRAWING SHEET ELEVATION (DRAWING SHEET DETAIL (DRAWING SHEET ELEVATION NUMBER, NUMBER) REFERENCE NUMBER, NUMBER) REFERENCE NUMBER, NUMBER) REFERENCES NUMBER, NUMBER) REVISION AX.XX 1 KEYNOTE 0 REFERENCE, EQUIPMENT P AX.XX 1 K0 REFERENCE, PLUMBING FIXT. lM 0 > REFERENCE, MECH. EQUIP. ROOM NAME AX.XX 1 101 ROOM NAME / NUMBER AX.XX N. HEIGHT 0" EXISTING GRADE MARKER 0 NEW GRADE MARKER; CLG. / arch rysa S All ideas, designs, and plans indicated or represented by these drawings are owned by and are property ofArchrysalis. and were created and developed for use in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose without the written permission of Archrysalis. 309 GREYSTONE ROAD CHARLOTTE NC 28209 704.807.2877 info@archrysalis.com j SADLER 3600 SADLER CHARLOTTE DATE DESCRIPTION R ROAD NC 28278 D INTERIOR RENOVATION HOME LOT SIZE = 23,035 SQ' (0.552 PROPOSED COVERED PORCH EXISTING HOME SIZE W/O EXISTING DECKS SIZE = VICINITY MAP LAKE WYLIE / I I Wwhatsoever co \ VICINITY cy� 06,T O N O O � -96 N a 0 MAP SCALE INTERSTATE 485 12.01.2021 CONSTRUCTION / PERMIT SET SADLER ROAD E o o o (- � ■ 0 1 TITLE SHEET W Lu �` s EXISTING DECK TO REMAIN REMOVE EXISTING ROOF ABOVE REMOVE EXISTING ROOF ABOVE 1 ,r EXISTING STAIR TO REMAIN -7 1c- =71 !== - T J REMOVE EXISTING FIREPLACE _1I 11 11 11 11 II EXISTING STAIRCASE TO REMAIN CUT OPENING FOR NEW SKYLIGHT -� 1 REMOVE EXISTING FIREPLACE CUT OPENING FOR NEW WINDOW; TYP. %�\ 1 1 UPPER LEVEL DEMOLITION PLAN / SCALE 1 /4"=1'-0" LOWER LEVEL DEMOLITION PLAN JN SCALE 1 /4"=1'-0" DEMOLITION DEFINITIONS 1. REMOVE: UNLESS ITEMS ARE OTHERWISE INDICATED TO BE REINSTALLED OR SALVAGED, REMOVE AND SCRAP. 2. REMOVE AND REINSTALL: REMOVE ITEMS INDICATED; CLEAN, SERVICE, AND OTHERWISE PREPARE FOR SERVICE; REINSTALL IN THE SAME LOCATION (OR IN THE LOCATION INDICATED). 3. REMOVE AND INSTALL NEW; REMOVE AN DISPOSE OF ITEMS INDICATED AND INSTALL NEW ITEMS IN THE SAME LOCATION (OR IN THE LOCATION INDICATED). 4. REMOVE AND SALVAGE; ITEMS INDICATED TO BE SALVAGED WILL REMAIN THE OWNER'S PROPERTY. CAREFULLY REMOVE AND CLEAN ITEMS INDICATED TO BE SALVAGED; PACK OR CRATE TO PROTECT AGAINST DAMAGE; IDENTIFY CONTENTS OF CONTAINERS; DELIVER TO THE LOCATION INDICATED. 5. REMOVE AND SCRAP; REMOVE AND DISPOSE OF ITEMS INDICATED. ALL DEMOLISHED OR REMOVED ITEMS AND MATERIALS SHALL BE CONSIDERED SCRAP, EXCEPT FOR THOSE INDICATED TO REMAIN, THOSE INDICATED TO BE REINSTALLED, AND THOSE INDICATED TO BE SALVAGED. 6. EXISTING TO REMAIN; CONSTRUCTION OR ITEMS INDICATED TO REMAIN SHALL BE PROTECTED AGAINST DAMAGE DURING DEMOLITION OPERATIONS. WHERE PRACTICABLE, AND WITH THE ARCHITECT'S PERMISSION, THE CONTRACTOR MAY ELECT TO REMOVE ITEMS TO A SUITABLE STORAGE LOCATION DURING DEMOLITION AND THEN PROPERLY CLEAN AND REINSTALL THE ITEMS. 7. VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO CONSTUCTION. 8. CONTRACTOR TO EVALUATE THE CONDITION OF EXISTING ROOF AND STRUCTURE AND ADVISE OWNER OF ANY FORESEEABLE PROBLEMS OR ISSUES NECESSITATING REPAIR OR REPLACEMENT WALL LEGEND: — — EXISTING WALL — — TO BE REMOVED / WINDOW / DOOR / FIXTURE TO REMAIN EXISTING WALL arch rysa S12.01.2021 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Archrysalis. and were created and developed for use in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of Archrysalis. 309 GREYSTONE ROAD CHARLOTTE NC 28209 704.807.2877 info@archrysalis.com jPLANS SADLER 3600 SADLER CHARLOTTE DATE DESCRIPTION ROAD NC 28278 RD CONSTRUCTION / PERMIT SET AD•10 DEMOLITION EXISTING ROOF TO BE REMOVED r1 L_J r__E3__ REMOVE EXISTING FIREPLACE SIDE ELEVATION (SOUTH) 04 SCALE 1/4"=1'-0" REMOVE EXISTING FIREPLACE / ILJ LJI Ire r�l M IN N N NI ILJ LJI REMOVE EXISTING FIREPLACE EXISTING ROOF TO BE REMOVED SIDE ELEVATION (NORTH) 03 SCALE 1/4"=1'-0" CATAWBA ELEVATION (WEST) 02 SCALE 1/4"=1'-0" REMOVE EXISTING FIREPLACE ILJ LJI Ir, rii iri ril N NN N ILJ LJI rr� 741 ILJ LJI Ir, rii iri ril N NN N ILJ LJI rr==o rr=o rr=o rr==, L -JL-JL-JL-J Ir=1 rr=o rr=o rr=o L —JL—JL—JL—J Ir=1 rr=o rr=o rr=o L —JL—JL—JL—J Ir=1 rr=o rr=o rr=o L -JL-JL-JL-J CUT OPENING FOR NEW ENTRY STREET ELEVATION (EAST) 0 SCALE 1/4"=1'-0" DEMOLITION DEFINITIONS 1. REMOVE: UNLESS ITEMS ARE OTHERWISE INDICATED TO BE REINSTALLED OR SALVAGED, REMOVE AND SCRAP. 2. REMOVE AND REINSTALL: REMOVE ITEMS INDICATED; CLEAN, SERVICE, AND OTHERWISE PREPARE FOR SERVICE; REINSTALL IN THE SAME LOCATION (OR IN THE LOCATION INDICATED). 3. REMOVE AND INSTALL NEW; REMOVE AN DISPOSE OF ITEMS INDICATED AND INSTALL NEW ITEMS IN THE SAME LOCATION (OR IN THE LOCATION INDICATED). 4. REMOVE AND SALVAGE; ITEMS INDICATED TO BE SALVAGED WILL REMAIN THE OWNER'S PROPERTY. CAREFULLY REMOVE AND CLEAN ITEMS INDICATED TO BE SALVAGED; PACK OR CRATE TO PROTECT AGAINST DAMAGE; IDENTIFY CONTENTS OF CONTAINERS; DELIVER TO THE LOCATION INDICATED. 5. REMOVE AND SCRAP; REMOVE AND DISPOSE OF ITEMS INDICATED. ALL DEMOLISHED OR REMOVED ITEMS AND MATERIALS SHALL BE CONSIDERED SCRAP, EXCEPT FOR THOSE INDICATED TO REMAIN, THOSE INDICATED TO BE REINSTALLED, AND THOSE INDICATED TO BE SALVAGED. 6. EXISTING TO REMAIN; CONSTRUCTION OR ITEMS INDICATED TO REMAIN SHALL BE PROTECTED AGAINST DAMAGE DURING DEMOLITION OPERATIONS. WHERE PRACTICABLE, AND WITH THE ARCHITECT'S PERMISSION, THE CONTRACTOR MAY ELECT TO REMOVE ITEMS TO A SUITABLE STORAGE LOCATION DURING DEMOLITION AND THEN PROPERLY CLEAN AND REINSTALL THE ITEMS. 7. VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO CONSTUCTION. 8. CONTRACTOR TO EVALUATE THE CONDITION OF EXISTING ROOF AND STRUCTURE AND ADVISE OWNER OF ANY FORESEEABLE PROBLEMS OR ISSUES NECESSITATING REPAIR OR REPLACEMENT WALL LEGEND: — — EXISTING WALL — — TO BE REMOVED / WINDOW / DOOR / FIXTURE TO REMAIN EXISTING WALL arch rysa S12.01.2021 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Archrysalis. and were created and developed for use in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of Archrysalis. 309 GREYSTONE ROAD CHARLOTTE NC 28209 704.807.2877 info@archrysalis.com jELEVATIONS SADLER 3600 SADLER CHARLOTTE DATE DESCRIPTION ROAD NC 28278 RD CONSTRUCTION / PERMIT SET AD•4O DEMOLITION EXTERIOR 01 WINDOW SCHEDULE # TYPE LOCATION WIDTH HT. FRAME DEPTH MFG. SERIES/ STYLE GLAZING MATERIAL FRAME MATERIAL FRAME FINISH OPERATION REMARKS 101 A KITCHEN #101 2'-8" 4'-0" - - - - - - DOUBLE HUNG 102 A ENTRY #102 2'-0" 4'-0" DOUBLE HUNG 103 A ENTRY #102 2'-0" 4'-0" DOUBLE HUNG 104 A LIVING ROOM #103 3'-0" 4'-0" DOUBLE HUNG 105 A LIVING ROOM #103 3'-0" 4'-0" DOUBLE HUNG 106 A BATHROOM #104 2'-0" 4'-0" DOUBLE HUNG 107 A BEDROOM #105 6'-0" 4'-0" DOUBLE HUNG 108 A LIVING ROOM #103 3'-0" 4'-0" CASEMENT NOTE: 1. ALL GLASS TO BE CLEAR UNLESS OTHERWISE NOTED. 2. GLAZING CONTRACTOR TO PROVIDE WINDOW FRAME FINISH AND GLASS SAMPLES FOR REVIEW BY DESIGNER PRIOR TO CONSTRUCTION. 3. ALL GLAZING NOTED AS 'TEMP.' TO BE TEMPERED GLASS. 4. SEE INTERIOR AND EXTERIOR ELEVATIONS FOR MORE INFORMATION 5. ALL GLAZING TO BE TEMPERED AS PER CODE REQUIREMNETS 6. VERIFY SIZE/LOCATION/OPERATION WITH DESIGNER PRIOR TO FRAMING & ORDERING SKYLIGHTS TYPE LOCATION INT WIDTH INT HT. MFG. SERIES SIZE CODE OPERATION REMARKS SK01 A FAMILY ROOM #201 46 1 /2" 46 1 /2" VELUX FCM 4646 FIXED EXTERIOR DOORS - EPIr - # TYPE LOCATION WIDTH HT. THICK MFG. SERIES DOOR MATERIAL SWING DOOR FINISH HDWR. SET REMARKS 101 A ENTRY #102 5-0" 9'-0" - - - - LH - - 7-0" DOOR W/ 2'-0" CLERESTORY 102 B LIVING ROOM #103 12'-0" 7-0" LH 3'-0" DOOR W/ SIDELITES 103 B DINING #103 12'-0" 7-0" SLIDING B01 B MASTER BEDROOM #B01 6-6" 6-8" SLIDING NTERIOR DOOR SCHEDULE , , ■ # TYPE LOCATION WIDTH HT. THICK MFG. SERIES DOOR MATERIAL SWING DOOR FINISH HDWR. SET REMARKS 104 C DINING #108 5-0" 6-8" - - - - BI-FOLD - - CLOSET DOOR 105 D DINING #108 2'-8" 6-8" LH 106 C BEDROOM #203 5-0" 6-8" BI-FOLD CLOSET DOOR 107 D BEDROOM #203 2'-8" 6-8" LH 108 D BATH #202 2'-8" 6-8" RH 109 D BEDROOM #105 2'-8" 6-8" LH 110 D BATH #104 2'-8" 6-8" RH 111 C BEDROOM #105 6-0" 6-8" BI-FOLD CLOSET DOOR B02 E CLOSET #B03 2'-8" 6-8" SLIDNIG POCKET DOOR B03 D BATH #B02 2'-8" 6-8" RH FAMILY ROOM MASTER BEDROOM NORTH STAIR 106 LIVING ROOM ///////// ///// UPPER LEVEL CONSTRUCTION PLAN / SCALE 1 /4"=1'-0" LOWER LEVEL CONSTRUCTION PLAN ♦ JN SCALE 1 /4"=1'-0" NOTES 1. EACH BEDROOM SHALL HAVE AT LEAST ONE WINDOW WHICH CONFORMS TO THE EMERGENCY ESCAPE AND RESCUE OPENING REQUIREMENTS LISTED IN R310 1.1. MIN. NET CLEAR OPENING OF 4 S.F. 1.2. MIN. NET CLEAR OPENING HEIGHT SHALL BE 22 INCHES 1.3. MIN. NET CLEAR OPENING WIDTH SHALL BE 20 INCHES 1.4. MIN. TOTAL GLAZING OF NOT LESS THAN 5 S.F. AT GROUND FLOOR 1.5. MIN. TOTAL GLASING OF NOT LESS THAN 5.7 S.F. AT UPPER FLOORS 1.6. MAX SILL HEIGHT OF 44 INCHES ABOVE FLOOR 2. CEILING JOISTS & WALL STUDS TO BE SHIFTED AS REQUIRED TO MAINTAIN LIGHT AND WALL FEATURE LOCATIONS FOR ALIGNMENTS AS PER PLANS 3. NOTIFY DESIGNER/CLIENT OF ANY INCONSISTANCIES BETWEEN ARCHITECTURAL & STRUCTURAL DRAWINGS PRIOR TO CONSTRUCTION 4. ALL DIMENSIONS PROVIDED TO FINSH PLAN LEGEND CLERESTORY WINDOW ABOVE (SEE WINDOW SCHEDULE) / OBJECT ABV. DOOR (SEE DOOR SCHEDULE) (SEE DOOR SCHEDULE) /////////////// (N) WALL (N) WALL W/ (N) WINDOW LINE OF HEADER //////////4 (N) POCKET © (N) PIVOT DOOR KEY NOTES EXISTING STAIR/DECK TO REMAIN. REPAIR AS REQUIRED PER 2018 NC RES. CODE STEP AS REQUIRED PER FINISH ELEVATION; PER 2018 NC RES CODE EXISTING CMU WALLS TO BE FINISHED PER 2018 NC RES CODE 9 RISERS AT 7" W/ 11" RUN PER 2018 NC RES CODE NEW ELECTRIC FIREPLACE NEW VANITY, TOILET, AND TUB/SHOWER LOW WALL; 36" ABOVE F.F. OF SECOND FLOOR NEW ASPHALT SHINGLE ROOF; TYP. NEW PERMEABLE CONCRETE GRASS BLOCK PAVERS NEW CONCRETE SLAB/PORCH EXISTING VINYL SIDING TO REMAIN. PATCH & REPAIR AS REQUIRED PAINT EXISTING CMU WALL 01 02 03 04 05 06 07 08 09 10 11 12 All represented are property and specified or whatsoever jPLANS rysa arch SADLER 3600 SADLER CHARLOTTE DATE ROAD NC 28278 DESCRIPTION RD I ' 12.01.2021 CONSTRUCTION / PERMIT SET ideas, designs, and plans indicated or by these drawings are owned by and of Archrysalis. and were created developed for use in connection with the project. None of such ideas, designs, plans shall be used for any purpose without the written permission of Archrysalis. 309 GREYSTONE ROAD CHARLOTTE NC 28209 704.807.2877 info@archrysalis.com A2• CONSTRUCTION 1 0 SIDE ELEVATION (SOUTH) 04 SIDE ELEVATION (NORTH) 03 SCALE 1/4"=1'-0" SCALE 1/4"=1'-0" 08 // 11 // // 08 12 6 // // // / </ 0 1 \ /� // / CATAWBA ELEVATION (WEST) 02 SCALE 1/4"=1'-0" 08 08 // 11 n // 11 // STREET ELEVATION (EAST) 0 SCALE 1/4"=1'-0" KEY NOTES 01 02 03 04 05 06 07 08 09 10 11 12 EXISTING STAIR/DECK TO REMAIN. REPAIR AS REQUIRED PER 2018 NC RES. CODE STEP AS REQUIRED PER FINISH ELEVATION; PER 2018 NC RES CODE EXISTING CMU WALLS TO BE FINISHED PER 2018 NC RES CODE 9 RISERS AT 7" W/ 11" RUN PER 2018 NC RES CODE NEW ELECTRIC FIREPLACE NEW VANITY, TOILET, AND TUB/SHOWER LOW WALL; 36" ABOVE F.F. OF SECOND FLOOR NEW ASPHALT SHINGLE ROOF; TYP. NEW PERMEABLE CONCRETE GRASS BLOCK PAVERS NEW CONCRETE SLAB/PORCH EXISTING VINYL SIDING TO REMAIN. PATCH & REPAIR AS REQUIRED PAINT EXISTING CMU WALL arch rysa i All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Archrysalis. and were created and developed for use in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of Archrysalis. 309 GREYSTONE ROAD CHARLOTTE NC 28209 704.807.2877 info@archrysalis.com SADLER RD 3600 SADLER ROAD CHARLOTTE NC 28278 DATE DESCRIPTION 12.01.2021 CONSTRUCTION / PERMIT SET A4.01 PROPOSED EXTERIOR ELEVATIONS IMPORTANT!!: CONTRACTOR SHALL READ ALL APPLICABLE NOTES RELEVANT TO THE PLANS PRIOR TO CONSTRUCTION. DESIGN LOADS AND GENERAL : 1. DESIGN LOADS ARE ALL DEAD LOADS PLUS: A. SLEEPING ROOMS 30 PSF B. ALL OTHER FLOORS 40 PSF C. BALCONIES 40 PSF ATTIC FLOOR LIVE LOADING WITH THE FOLLOWING: D. I.) AREA ACCESSIBLE BY STAIRS 30 PSF E. II.) ROOF SLOPES > 3:12 20 PSF F. III.) ROOF SLOPES < 3:12 10 PSF G. ROOF LIVE LOAD 20 PSF H. WIND LOAD 115 MPH (ULTIMATE) EXPOSURE B (ASCE7-10) I. TILE FLOORS ARE ASSUMED TO BE CERAMIC OR PORCELAIN DESIGNED FOR AN ADDITIONAL 10PSF DEAD LOAD AND L/360 DEFLECTION UNLESS OTHERWISE NOTED ON PLANS. 2. ALL DESIGNS ARE IN ACCORDANCE WITH NORTH CAROLINA RESIDENTIAL CODE, 2018 EDITION. REFER TO THE RELEVANT CODE FOR ANY ADDITIONAL INFORMATION NOT COVERED IN THESE NOTES OR THE DESIGNS. 3. ENGINEERING DESIGN IS FOR STRUCTURAL INFORMATION ONLY. THE ENGINEER OF RECORD DOES NOT ACCEPT RESPONSIBILITY FOR DIMENSION ERRORS, ARCHITECTURAL ERRORS, DETAILING OF WATERPROOFING, PLUMBING, ELECTRICAL, MECHANICAL INFORMATION, OR CONSTRUCTION METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR ANY PART OF THE PLAN NOT RELEVANT TO THE STRUCTURAL INFORMATION. 4. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL DRAWINGS AND OTHER CONTRACT DRAWINGS AND REPORT ANY DISCREPANCIES WITH THE PROJECT ENGINEER AND ARCHITECT PRIOR TO THE FABRICATION AND INSTALLATION OF ANY STRUCTURAL MEMBERS. 5. THE GENERAL CONTRACTOR IS REQUIRED FOR PROVIDING ALL REQUIRED BRACING AND SHORING DURING CONSTRUCTION TO MAINTAIN THE STABILITY AND SAFETY OF ALL STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PROCESS UNTIL THE STRUCTURE IS TIED TOGETHER AND COMPLETE. 6. WHERE CONFLICTS OCCUR BETWEEN GENERAL NOTES AND SPECIFICATIONS, THE MOST STRINGENT REQUIREMENT SHALL APPLY. 7. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. 8. LOADS APPLIED TO THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE SAFE LOAD -CARRYING CAPACITY OF THE STRUCTURAL MEMBERS. THE LIVE LOADS USED FOR THE DESIGN OF THE STRUCTURE ARE INDICATED IN THE GENERAL NOTES. DO NOT APPLY ANY CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY INSTALLED AND ALL TEMPORARY BRACING IS IN PLACE. 9. WHERE DIMENSIONS ARE NOT INDICATED, BEAMS ARE INTENDED TO ALIGN UNDER LOAD BEARING WALLS. SEE THE ARCHITECTURAL PLANS FOR DIMENSIONS TO WALLS. 10. WHEN STEEL FRAMES ARE INDICATED ON THE PLANS, STEEL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. CONTRACTOR SHALL REVIEW, APPROVE, AND SIGN EACH SHEET PRIOR TO SUBMISSION. THE STRUCTURAL ENGINEER'S REVIEW SHALL BE FOR CONFORMANCE WITH THE DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW, CHECK, AND COORDINATE THE SHOP DRAWINGS PRIOR TO SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF THE SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC. FOUNDATIONS: 1. SHALLOW FOUNDATIONS ARE DESIGNED FOR AN ASSUMED SOIL BEARING CAPACITY OF 2,000 PSF. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE ENGINEER OF RECORD IF ANY SOILS ARE FOUND TO BE UNSUITABLE FOR THIS BEARING CAPACITY. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING SOIL TESTING TO ENSURE THAT THE BEARING CAPACITY OF THE SOIL MEETS OR EXCEEDS THIS VALUE. 2. ALL FILL IS TO BE COMPACTED TO 95% DENSITY AS MEASURED BY THE STANDARD PROCTOR TEST (ASTM D-1557), OTHERWISE USE SELF -COMPACTING CLEAN WASHED #57 STONE. 3. ALL SOILS AND FILL UNDER FLOORS WITHIN AND/OR UNDER BUILDINGS SHALL HAVE PRECONSTRUCTION SOIL TREATMENT FOR PROTECTION AGAINST TERMITES. CERTIFICATION OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BYA LICENSED PEST CONTROL COMPANY. 4. ALL FOOTING EXCAVATIONS SHALL BE NEAT, STRAIGHT, AND LEVEL IN THE PROPER ELEVATIONS TO RECEIVE THE CONCRETE. EXCESSIVE VARIATIONS IN THE DIMENSIONS OF FOOTINGS OR SLAB WILL NOT BE PERMITTED. REINFORCING STEEL AND MESH SHALL BE ACCURATELY PLACED AND SUPPORTED TO MAINTAIN THEIR POSITION DURING THE CONCRETE POURING. EDGE FORMS SHALL BE USED FOR CONCRETE THAT WILL BE EXPOSED. 5. ALL SLAB PENETRATIONS ARE TO BE THE RESPONSIBILITY OF THE CONTRACTOR. PENETRATIONS INTERFERING WITH REINFORCING SHALL BE APPROVED BY THE ENGINEER OF RECORD PRIOR TO THE PLACEMENT OF CONCRETE. 6. ELEVATION DIFFERENCE BETWEEN THE BOTTOM OF ADJACENT FOOTINGS SHALL BE LESS THAN THEIR HORIZONTAL DISTANCE LESS ONE FOOT. (STEPPED FOOTING) DIFFERENTIAL HEIGHTS BETWEEN FOOTINGS CAN BECOME EXCESSIVE USUALLY WHERE A PIER FOOTING IN A CRAWLSPACE OR GARAGE FOOTING IS NEXT TO A BASEMENT WALL FOOTING. 7. SIZE OF INTERIOR CMU PIERS DEPEND ON HEIGHT AND LOADING. UNLESS OTHERWISE NOTED AS LARGER, CMU PIERS SHALL BE: PIER 8x16 8x16 12x16 12x16 16x16 16x16 FILL HOLLOW GROUTED HOLLOW GROUTED HOLLOW GROUTED MAX. HEIGHT 32" 80" 48" 120" 64" 160" CONCRETE FTG 24"x36"x10" 24"x36"x10" 24"x36"x10" 36"x36"x10" 36"x36"x10" 36"x36"x10" *ALL HOLLOW PIERS AND WALLS TO HAVE TOP 8" GROUTED. 8. SHIMS USED BETWEEN MASONRY PIERS AND WOOD GIRDERS SHALL CONSIST OF EITHER SOLID WOOD OR MULTIPLE STACKS OF STEEL SHIMS EQUAL IN WIDTH TO THE GIRDER AND FULLY CONTACT AT LEAST 8" THE LENGTH OF THE PIER. SPECIAL FOUNDATION CONSIDERATIONS: 1. FOR UNRESTRAINED RETAINING WALLS SEE SPECIAL DESIGNS ON DRAWINGS. 2. ANCHOR BOLTS SHALL BE INSTALLED AS REQUIRED BY CODE UNLESS OTHERWISE NOTED ON THE PLANS. DO NOT USE FOUNDATION STRAPS IN BRICK VENEER. STRAPS ARE ONLY ACCEPTABLE IN CONCRETE OR GROUT FILLED CMU AND MUST BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE STANDARD ANCHOR BOLTS OR STRAPS ARE MISSED OR NOT INSTALLED PROPERLY, A RETROFIT BOLT SUCH AS A SIMPSON Z' DIAMETER TITEN HD BOLT OR EPDXY BOLT MAY BE USED IN ITS PLACE IN A MANNER APPROVED BY THE MANUF. 3. ALL REINFORCING STEEL WHEN SPECIFIED, SHALL BE LAPPED AT LEAST 24" AT SPLICES 4. WHERE PRE -EMBEDDED HOLD DOWN ANCHORS ARE SPECIFIED ON THE PLANS, INSPECTION BY ENGINEER IS REQUIRED PRIOR TO POURING CONCRETE FOOTINGS. 5. THE TOPS OF ALL RESTRAINED BASEMENT WALLS SHALL EXTEND TO THE BOTTOM OF THE FLOOR FRAMING SILL PLATE WHEN UNBALANCED FILL EXCEEDS 48". 6. RESTRAINED BASEMENT WALLS SHALL BE RESTRAINED AT THE TOP AND BOTTOM PRIOR TO BACKFILLING. FRAMING CONSTRUCTION - OTHER THAN ROOF: 1. SEE SECTION R602.3 (1) OF THE CODE FOR A GENERAL FASTENER SCHEDULE FOR STRUCTURAL MEMBERS. ALL LIGHT GAUGE METAL CONNECTORS SPECIFIED ON THE PLAN ARE DESIGNATIONS BY SIMPSON STRONG TIE. REFER TO SIMPSON'S PRODUCT MANUAL FOR SIZES, SPECIFICATIONS, AND INSTALLATION INSTRUCTIONS. OTHER BRANDS MAY BE USED PROVIDED THE CONNECTION IS EQUAL TO OR STRONGER THAN THAT SPECIFIED. 2. SUPPORT ALL FLOOR JOISTS WITH METAL HANGERS. 2X2 LEDGERS ARE ONLY ACCEPTABLE FOR ATTIC JOISTS. 3. WOOD BEAMS SHALL BE SUPPORTED BY METAL HANGERS OF ADEQUATE CAPACITY WHERE FRAMING INTO BEAMS OR LEDGERS. THE FOLLOWING HANGER SCHEDULE MAY BE USED UNLESS NOTED OTHERWISE ON THE PLAN: (2) (2) (3) (2) (2) (2) (2) MEMBER SIZE SIMPSON HANGERS 2X8 LUS 28-2 2X10 LUS 210-2 2X8 OR (3) 2X10 LUS 28-3 2X12 LUS 210-2 13/4"X9%4"LVL HUS410 13/4"X11'/" LVL HUS412 13/4"X14"LVL HUS412 ALL TRIPLE LVLs HHUS 5.50/10 4. NOTE: FILL ALL HOLES IN MULTIPLE PLY BEAM HANGERS WITH 16d x 3%2" COMMON NAILS (321"x 0.162") OR 16d x221' (21"x 0.162") NAILS UNLESS OTHERWISE SPECIFIED BY THE MANUFACTURER. DO NOT BEND OR MODIFY THE HANGER OR USE INAPPROPRIATE FASTENERS. DO NOT USE 10dX 1%2" "HANGER NAILS" UNLESS OTHERWISE NOTED ON THE PLANS OR IN SITUATIONS WHERE ONLY 14" OR LESS OF WOOD IS PROVIDED TO NAIL INTO. 5. METAL HOLD-DOWN STRAPS SHALL BE INSTALLED OVER SHEATHING AND VISIBLE FOR INSPECTION. FILL ALL HOLES IN METAL STRAPS WITH 16d SINKER NAILS (0.148"X 34"). 6. ALL FRAMING LUMBER MAY BE SPF#2 OR SOUTHERN PINE #2 OR BETTER UNLESS NOTED OTHERWISE. 7. ALL WALLS UP TO 10 FT. TALL SHALL BE 2X4 SPF#2 @ 16" O.C. UNLESS NOTED OTHERWISE ON THE PLAN. TALLER WALLS SHALL COMPLY WITH TABLE R602.3(5) OF THE CODE OR AS NOTED ON THE PLAN. 8. ALL EXTERIOR WALLS IN TWO STORY OR VAULTED ROOMS SHALL HAVE THE STUDS BALLOON FRAMED CONTINUOUSLY BETWEEN THE FLOOR AND CEILING/ROOF DIAPHRAGMS. 9. LUMBER BEAMS TO HAVE SAME NUMBER OF SUPPORT STUDS AS THE NUMBER OF PLIES UNLESS NOTED OTHERWISE. 10. FASTEN FIRST KING STUD TO LUMBER HEADER WITH AT LEAST THREE 16D COMMON NAILS (321"X0.162") IN EACH PLY. EACH KING STUD PLY SHALL BE NAILED TO THE OTHER WITH TWO ROWS OF 3"X0.131" NAILS SPACED AT 9" O.C. SEE R602.7.5 FOR NUMBER OF KING STUDS REQUIRED IF NOT NOTED ON PLANS. 11. ALL LOAD -BEARING HEADERS ARE (2)2X8 SPF#2 DROPPED OR FLUSH DOUBLE PLY RIM BOARD HEADERS WITH JOISTS CONNECTED TO HEADER WITH JOIST HANGERS UNLESS OTHERWISE NOTED. FLUSH RIM BOARD HEADERS IN ACCORDANCE WITH R602.7.2 MAY BE USED AND ARE GENERALLY RECOMMENDED WHEN POSSIBLE. 12. STEEL BEAMS MUST HAVE (5)-2X4 OR (4)-2X6 STUDS UNDER EACH END SUPPORT UNLESS NOTED OTHERWISE. 13. "LVL" AND GLU-LAM BEAMS MUST HAVE ENOUGH STUDS TO SUPPORT ALL PLIES AT EACH END WITH A MINIMUM OF (3)-2X4 OR (2)-2X6 STUDS UNDER EACH END UNLESS NOTED OTHERWISE. 14. ALL BEAMS AND HEADERS SHALL BE RESTRAINED AGAINST ROTATION AT THEIR ENDS BY EITHER FRAMING JOISTS, BRACING, OR KING STUDS. 15. ALL BUILT-UP COLUMNS SHALL HAVE EACH PLY NAILED TO THE OTHER WITH TWO ROWS OF 3"X0.131" NAILS SPACED AT 9" ON CENTER OR HEADLOK SCREWS @ 9" O.C. THAT CAN PENETRATE ALL PLIES. NAIL THE EXTERIOR SHEATHING OR INTERIOR GYPSUM TO EACH PLY WITH FASTENERS SPACED AT 12" O.C. 16. WHERE THREE OR FOUR -PLY LVL BEAMS ARE SIDE -LOADED (JOISTS FRAME INTO THE SIDE AT THE OUTSIDE PLIES), FASTEN ALL TRIPLE PLY LVLs TOGETHER WITH TWO ROWS OF 5" LONG FLATLOK OR SIMPSON SDS SCREWS @ 16" O.C. AND FOUR PLY LVLs WITH TWO ROWS OF 63/4" FLATLOK SCREWS @ 16" O.C. UNLESS NOTED OTHERWISE ON THE PLANS. THE SCREWS SHALL BE LOCATED A MINIMUM OF 2" AND A MAXIMUM OF 3" FROM THE TOP OR BOTTOM OF THE BEAM. 17. WHERE LVL BEAM HANGERS CONNECT TO A THREE OR FOUR PLY LVL MEMBER, THERE SHALL BE AT LEAST ONE-HALF THE AMOUNT OF TRUSSLOK SCREWS ON EACH SIDE OF THE HANGER AS THERE ARE NAIL HOLES IN THE HANGER FLANGE. SEE THE DETAIL ABOVE. SCREWS SHALL BE KEPT TO A 2" GRID SPACING PATTERN WITH A MINIMUM 2" EDGE DISTANCE. TO AVOID USING SCREW FASTENERS, A SOLID "PSL" BEAM OF EQUAL DIMENSIONS AND STRENGTH TO THE BUILT-UP LVL BEAM MAY BE USED INSTEAD. 8 SCREWS (Z OF 15 ROUNDED UP). FASTENERS MUST BE LONG ENOUGH TO PENETRATE ALL PLIES. MULTI -PLY LVL CONNECTION AT HANGER EXAMPLE 18. STRUCTURAL COMPOSITE WOOD BEAMS MAY BE DRILLED FOR WIRING AND PLUMBING AS SHOWN BELOW. HOLE MAY BE CUT IN SHADED AREA BEAM 'd'=HOLE DEPTH DIAMETER 24" MIN. 2d MIN. 2" MIN. 2Z' MIN. EN BEADRING d=22" MAX FOR 9i" BEAM d=4" MAX FOR 113" AND DEEPER BEAM BEAM HOLE DETAIL 24" 24" MIN. MIN. INTERMEDIATE BEARING 19. WHERE NON -LOAD BEARING PARTITIONS FALL BETWEEN FLOOR JOISTS OR TRUSSES, 2X4 LADDERS @ 24" O/C MUST BE PLACED PERPENDICULAR TO THE JOISTS TO SUPPORT THE PLYWOOD DECKING. THE LADDERS SHALL BE SUPPORTED WITH A SIMPSON "Z" CLIP OR SIMILAR DEVICE. A DOUBLE JOIST CAN ALSO BE USED AND IS ALLOWED TO BE SEPARATED 4" MAX TO ALLOW FOR PLUMBING AND WIRING. WHERE THERE ARE NO OBSTRUCTIONS A SINGLE JOIST CAN BE INSTALLED UNDER THE WALL. 20. ALL WOOD I -JOISTS AND OPEN WEB FLOOR TRUSSES MUST BE BRACED IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS PLUS DETAILS SHOWN ON PLANS. LOAD -BEARING PARTITIONS, JACKS, BEAMS AND COLUMN SUPPORTS MUST BE SOLID BLOCKED THROUGH FLOOR. TRUSSES AND PLYWOOD CANNOT CARRY CONCENTRATED POINT LOADS. I -JOIST MATERIAL SHOULD NOT BE USED AS BLOCKING UNDER CONCENTRATED POINT LOADS. ALL POINT LOADS MUST BE CARRIED TO FOUNDATIONS WITH ADEQUATE BLOCKING AND/OR BEAMS. 21. ALL STEEL COLUMNS SHALL BEAR ON CONCRETE, MASONRY, OR STEEL ONLY UNLESS OTHERWISE NOTED. BEAMS THAT BEAR ON TOP OF STEEL COLUMNS SHALL BE WELDED TO THE COLUMN. 22. ALL STRUCTURAL FRAMING LUMBER EXPOSED DIRECTLY TO THE WEATHER OR BEARING DIRECTLY ON EXTERIOR MASONRY PIERS OR CONCRETE SHALL BE TREATED IN ACCORDANCE WITH THE AWPA UC3B CATEGORY. ALL WOOD IN CONTACT WITH THE GROUND IS TO CONFORM WITH THE AWPA UC4B CATEGORY. SEE SECTION R317.3.1 OF THE CODE FOR APPROVED FASTENERS IN TREATED LUMBER. 23. ALL POINT LOADS FROM ROOF BRACES, JACK STUDS, BEAM SUPPORTS -WHETHER WOOD OR STEEL -CANNOT BEAR ON SHEATHING ALONE. BLOCKING EQUAL TO OR BETTER THAN THE POINT LOAD SUPPORTS ABOVE MUST BE CARRIED THROUGH ALL CONSTRUCTION TO THE FOUNDATION. 24. ALL WALL SHEATHING SHALL BE 16" OSB OR 32" PLYWOOD ORIENTED LONG SIDE VERTICALLY. FASTEN SHEATHING WITH 2i" X 0.113" GALVANIZED RING SHANK NAILS AT 6" O.C. ALONG PANEL EDGES AND 12" O.C. ALONG INTERMEDIATE FRAMING UNLESS OTHERWISE NOTED. CARE SHOULD BE TAKEN TO SET THE PNEUMATIC NAIL GUN AIR PRESSURE CORRECTLY SO AS NOT TO OVERDRIVE THE NAILHEAD INTO THE SHEATHING. OTHER FASTENERS APPROVED PER TABLE R602.3 (1&2) OF THE CODE MAY BE USED. PROVIDE 2X4 BLOCKING AT ALL HORIZONTAL SEAMS TO PROVIDE EDGE NAILING FOR SHEATHING. 25. ALL ENGINEERED WOOD SHEAR WALLS AND PORTAL FRAMES REQUIRE INSPECTION OF FASTENERS PRIOR TO CONCEALING THEM WITH HOUSEWRAP OR CLADDING. IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT THE ENGINEER AT THE PROPER TIME TO ALLOW FOR THIS VERIFICATION. 26. AT ALL STAIRS, EVERY STUD AT EACH STRINGER MUST BE NAILED TO EACH STRINGER WITH A MINIMUM OF TWO (3"X 0.131") NAILS. THIS WILL AVOID CRACKING BETWEEN WALLBOARD AND TOP OF BASE MOLDING DUE TO VERTICAL OSCILLATION OF STAIR STRINGERS. 27. ALL STAIRS ARE TO BE DESIGNED BY MANUFACTURER. THE SCOPE OF THIS ENGINEERED DESIGN DOES NOT INCLUDE STAIR DESIGN. ALL "SELF SUPPORTING STAIRS" MUST BE CONNECTED TO ADEQUATE FRAMING TO SUPPORT THE LOAD OF THE STAIR CASE. IT IS THE STAIR MANUFACTURER'S RESPONSIBILITY TO PROVIDE THE E.O.R. WITH ALL POINT LOADS PRIOR TO CONSTRUCTION. ALL STAIRS SHALL BE DESIGNED BY THE MANUFACTURER. HEADERS AND LINTELS: MASONRY LINTELS 1. SEE SECTION R703.8.3 FOR LINTEL SPAN REQUIREMENTS. WHEN SPANS EXCEED THE CODE'S REQUIREMENTS, FASTEN L4"X4"X16" STEEL ANGLE TO WOOD HEADER WITH 21Y2)X4" GALVANIZED LAG SCREWS @ 16"O.C. EXTEND ALL ANGLES 6" PAST OPENING TO BEAR ON MASONRY VENEER AT ENDS. 2. WHEN STRUCTURAL STEEL BEAMS WITH BOTTOM PLATES ARE USED TO SUPPORT MASONRY, THE BOTTOM PLATE MUST EXTEND THE FULL LENGTH OF THE STEEL BEAM. THIS PROVIDES SUPPORT TO THE ENDS OF THE PLATE BY BEARING ON THE ADJACENT MASONRY JAMBS. THE BEAM SHOULD BE TEMPORARILY SHORED PRIOR TO LAYING THE MASONRY. THE SHORING MAY BE REMOVED FIVE DAYS AFTER LAYING THE MASONRY. 3. ALL BRICK VENEER OVER LOWER ROOFS (BRICK CLIMBS) MUST HAVE A STRUCTURAL ANGLE FASTENED TO AN ADJACENT STUD WALL IN ACCORDANCE WITH SECTION R703.8.2.1 OF THE CODE OR THE DETAIL ON THE PLAN, WITH STEEL BRICK STOPS TO PREVENT SLIDING OF BRICK. 4. ALL "SELF-SUPPORTING MASONRY ARCHES" TO BE DESIGNED AND INSTALLED PER MASONRY CONTRACTOR. ROOF CONSTRUCTION: 1. IN ADDITION TO THE CODE'S FASTENER SCHEDULE, UNLESS NOTED OTHERWISE ON THE PLAN, INSTALL SIMPSON SDWC15600 SCREWS OR H1 OR H2.5A HURRICANE CLIPS AT THE ENDS OF THE RAFTERS WHERE THEY BEAR ON THE WALL PLATE @ 48" O.C. ON OPEN ROOF AREAS, SUCH AS PORCHES, INSTALL SIMPSON CONNECTOR AT EACH RAFTER. FASTEN HURRICANE CLIPS TO THE OUTSIDE OF THE WALL PLATE WITH 8d COMMON NAILS AND TO THE RAFTER OR TRUSS WITH 8dX12' NAILS. INSTALLING OVER WALL SHEATHING IS ACCEPTABLE. 2. ALL ROOF TRUSSES MUST BE INSTALLED IN ACCORDANCE WITH TRUSS MANUFACTURERS' REQUIREMENTS. TRUSS DESIGNS AND LAYOUT SHALL BE SUBMITTED TO ENGINEER OF RECORD FOR APPROVAL. CONNECTIONS TO RESIST UPLIFT SHALL BE INSTALLED WHERE REQUIRED. WHEN ROOF TRUSS MANUFACTURERS DO NOT PROVIDE THE REQUIRED CONNECTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ROOF TRUSS ENGINEER OR THE ENGINEER OF RECORD TO PROVIDE AN ADEQUATE CONNECTOR. WHEN NO CONNECTIONS ARE REQUIRED BY THE MANUFACTURER INSTALL SIMPSON H1 OR H2.5A CONNECTORS AT EACH END OF THE TRUSS AS A MINIMUM. 3. HORIZONTAL COMPRESSION CHORD BRACING SHALL BE ADEQUATELY CONNECTED AT THE GABLE WALL ENDS OR WITH DIAGONAL BRACING AT ENDS TO RESTRAIN BRACE FORCE. BRACING DETAILING SHALL BE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER. 4. UNLESS OTHERWISE NOTED ON THE PLANS, RAFTERS SHALL BE 2X6 SPF#2 @ 16" 0/C FOR SHINGLES WITH 16" OSB SHEATHING WITH ONE LAYER OF 15# FELT UNLESS NOTED OTHERWISE. THEY ARE TO BE CUT INTO HIPS, RIDGES, ETC., UNLESS NOTED OTHERWISE. TILE, SLATE AND OTHER HEAVY ROOF COVERINGS SHALL USE 2X8 SPF#2 @ 16" 0/C WITH y" MINIMUM SHEATHING WITH (2) LAYERS OF 15# FELT, OR AS RECOMMENDED BY THE ROOF COVERING MANUFACTURER. 5. ALL RAFTERS FRAMING INTO STRUCTURAL RIDGE BEAMS (RIDGES WITHOUT CEILING TIES), SHALL BE CONNECTED WITH THREE 3"X 0.131" TOE -NAILS FOR SPANS UP TO 8 FT. AND A SIMPSON LRU28 HANGER OR A34 BRACKET FOR SPANS GREATER THAN 8 FT. 6. VAULTED CEILINGS REQUIRE SPECIAL RAFTER TIES OR A STRUCTURAL RIDGE BEAM PER THE PLANS. ALL HIPS, VALLEYS, AND RIDGES ARE 2X10 SPF#2 UNLESS NOTED OTHERWISE. 7. ALL "HOGS" SHALL BE COMPOSED OF TWO 2X6'S OR TWO 2X8'S, AS INDICATED ON THE PLAN. THE BOARDS SHALL BE FASTENED TOGETHER AT THEIR ENDS WITH 3"X0.131" NAILS AT 4" ON CENTER TO FORM AN "L" SHAPE. SEE THE DETAIL BELOW. 8. RAFTERS MAY BE SPLICED OVER HOGS. SPLICE RAFTER HOGS ONLY AT A ROOF BRACE. 9. GABLE END WALLS WHERE GREATER THAN 6 FT. TALL MUST BE BRACED PARALLEL TO RIDGES WITH A MINIMUM OF 2X6 DIAGONAL BRACES @ 6 FT. O.C. ALONG THE GABLE WALL TO INTERIOR CEILING JOISTS. BRACES TO BEAR ON 2X6 HOGS AND TO THE GABLE WALL AT APPROXIMATELY MID -HEIGHT. 10. WHERE CEILING JOISTS RUN PARALLEL TO GABLE WALLS, INSTALL 2X4X6FT. LONG STRONGBACKS FLATWISE SPACED AT 6 FT. ON CENTER TYING TO THE TOPS OF EACH CROSSING CEILING JOIST WITH 3-10d NAILS AND TO THE GABLE WALL. 11. ALL ROOF BRACES MUST HAVE A STUD FROM PLATE THROUGH ALL FLOORS TO THE FOUNDATION OR SUPPORTING BEAM BELOW. NO BRACES SHALL BE ATTACHED TO TOP WALL PLATE WITHOUT STUDS DIRECTLY UNDER THEM. WHEN >26° (2V:1H) ATTACH ROOF BRACE WITH SIMPSON A34 BRACKET AT BASE RAFTER HOG DETAIL ROOF PLAN LEGEND: HOG ROOF BRACE (2)2X4 < 7 FT., (2)2X6 > 7 FT. A. ® INDICATES LOCATION OF ROOF BRACE POINT AT RAFTER LEVEL. B. ®-BARROW AWAY FROM THE BRACE POINT INDICATES DIRECTION OF ROOF BRACE TO PARTITION, BEAM, OR OTHER BRACE POINT BELOW. C. BARROW INTO BRACE POINT INDICATES A VERTICAL OR ALMOST VERTICAL ROOF BRACE TO PARTITION, BEAM, OR OTHER BRACE POINT BELOW. D. ROOF BRACES UNDER 7'-0" ARE 2-2X4 NAILED WITH 3"X 0.131"NAILS @ 6" O.C. VERTICALLY FROM TOP TO BOTTOM. BRACES LONGER THAN 7'-0" SHALL CONSIST OF (2)2X6 T-BRACES. BRACES LONGER THAN 12 FT. MUST BE BRACED HORIZONTALLY IN TWO DIRECTIONS AT MID -HEIGHT. CONNECT BOTTOMS OF ALL BRACES THAT ARE NOT WITHIN 26° FROM VERTICAL TO BEAMS OR WALLS WITH ONE SIMPSON A34 BRACKET. MATERIALS SPECIFICATIONS: CONCRETE GENERAL NOTES: 1. EXCEPT WHERE OTHERWISE NOTED, FOR ALL CONCRETE, THE PROPORTIONS OF CEMENT, AGGREGATE, AND WATER TO ATTAIN REQUIRED PLASTICITY AND COMPRESSIVE STRENGTH SHALL BE IN ACCORDANCE WITH ACI 318 CODE. CONCRETE SHALL BE 3,000 PSI IN 28 DAYS FOR FOOTINGS, WALLS, BEAMS, COLUMNS AND SLABS, UNLESS NOTED OTHERWISE. 2. BEFORE PLACING CONCRETE, ALL DEBRIS, WATER AND OTHER DELETERIOUS MATERIAL SHALL BE REMOVED FROM THE PLACES TO BE OCCUPIED BY THE CONCRETE. THE PLACING OF ALL CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318 AND ASTM C94 REQUIREMENTS. CONCRETE SHALL BE RAPIDLY HANDLED FROM THE MIXER TO FORMS AND DEPOSITED AS NEARLY AS POSSIBLE TO ITS FINAL POSITION TO AVOID SEGREGATION DUE TO REHANDLING. CONCRETE TO BE SPADED AND WORKED BY HAND AND VIBRATED TO ASSURE CLOSE CONTACT WITH ALL SURFACES OF FORMS AND REINFORCING STEEL AND LEVELED OFF AT PROPER GRADE TO RECEIVE FINISH. ALL CONCRETE SHALL BE PLACED UPON CLEAN, DAMP SURFACES. VIBRATION SHALL BE APPLIED DIRECTLY TO THE CONCRETE AND SHALL BE SUFFICIENT TO CAUSE FLOW OF SETTLEMENT BUT NOT LONG ENOUGH TO CAUSE SEGREGATION OF THE MIX. 3. SLAB ON GRADE SHALL BE REINFORCED WITH 6X6, W1.4XW1.4 WELDED WIRE FABRIC OR FIBERMESH SYNTHETIC FIBERS - FIBRILLATED POLYPROPYLENE FIBERS ENGINEERED AND DESIGNED FOR USE IN CONCRETE, COMPLYING WITH ASTM C 1116, TYPE III, 3/4" LONG MAXIMUM, UNIFORMLY DISPERSED IN CONCRETE MIX AT MANUFACTURER'S RECOMMENDED RATE, BUT NOT LESS THAN 1.5 Ib/CUBIC YARD. 4. CONSTRUCTION JOINTS SHALL BE LOCATED IN ACCORDANCE WITH ACI 301. ALL REINFORCING STEEL SHALL BE CONTINUOUS ACROSS JOINTS. IN SLABS ON GRADE, SAW CONTRACTION JOINTS SHALL NOT BE OVER 12 FEET CENTER TO CENTER EACH WAY. JOINTS SHALL BE SAWN A DEPTH OF ONE-THIRD OF THE SLAB THICKNESS. SAWING OF THE JOINTS SHALL COMMENCE AS SOON AS THE CONCRETE HAS HARDENED SUFFICIENTLY TO PERMIT SAWING WITHOUT EXCESSIVE RAVELING. FILL THE SAW CUTS WITH APPROVED JOINT FILLER AFTER THE CONCRETE HAS CURED. 5. CONCRETE, WHEN DEPOSITED, SHALL HAVE A TEMPERATURE NOT BELOW 50° F AND NOT ABOVE 90° F. THE METHODS AND RECOMMENDED PRACTICES AS DESCRIBED IN ACI 306 SHALL BE FOLLOWED FOR COLD WEATHER CONCRETING AND ACI 305 FOR HOT WEATHER CONCRETING. 6. FRESHLY PLACED CONCRETE SHALL BE PROTECTED FROM PREMATURE DRYING BY ONE OF THE FOLLOWING METHODS: • PONDING OR CONTINUOUS SPRINKLING • ABSORPTIVE MAT OR FABRIC KEPT CONTINUOUSLY WET • WATERPROOF PAPER CONFORMING TO ASTM C171 • APPLICATION OF AN APPROVED CHEMICAL CURING COMPOUND 7. THE CURING SHALL CONTINUE UNTIL THE CUMULATIVE NUMBER OF DAYS WHEN THE AMBIENT TEMPERATURE ABOVE 50° F HAS TOTALED SEVEN. DURING CURING, THE CONCRETE SHALL BE PROTECTED FROM ANY MECHANICAL INJURY, LOAD STRESSES, SHOCK, VIBRATION, OR DAMAGE TO FINISHED SURFACES. 8. REINFORCING STEEL BARS SHALL BE DEFORMED IN ACCORDANCE WITH ASTM A305 AND OR A408 AND FORMED OF ASTM A615-78 GRADE 60 STEEL. WELDED WIRE FABRIC REINFORCING TO BE ASTM A185 STEEL WIRE. ACCESSORIES SHALL CONFORM TO THE CRSI "MANUAL OF STANDARD PRACTICE." THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED OVER REINFORCING BARS: • EXPOSED TO EARTH 3" • EXPOSED TO WEATHER 1%" • SLABS NOT EXPOSED TO WEATHER 3/4" • BEAMS AND COLUMNS 1%" MASONRY GENERAL NOTES: 9. MASONRY WALLS ARE TO BE OF THE SIZES AND IN THE LOCATIONS SHOWN ON THE PLANS AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF ACI 530. 10. HOLLOW LOAD BEARING UNITS: ASTM C90 MADE WITH LIGHTWEIGHT OR NORMAL WEIGHT AGGREGATES. GRADE N-I UNITS SHALL BE PROVIDED FOR EXTERIOR AND FOUNDATION WALLS. GRADE N-I OR S-I UNITS SHALL BE PROVIDED FOR OTHER LOAD -BEARING WALLS OR PARTITIONS. 11. CONCRETE BUILDING BRICK: ASTM C55 MADE WITH LIGHTWEIGHT OR NORMAL AGGREGATES, GRADE N-I OR S-I EXCEPT THAT BRICK EXPOSED TO WEATHER SHALL BE N-I. 12. MORTAR: ASTM C270-95, TYPE S PREPACKAGED MORTAR MIX WHICH SHALL NOT CONTAIN ANY NON-CEMENTITIOUS FILLERS COMBINED WITH NOT MORE THAN THREE PARTS SAND PER ONE PART MIX. 13. REINFORCING STEEL: ASTM A615 GRADE 60 STEEL DEFORMED BARS WHERE INDICATED ON THE PLANS. WHERE REINFORCING BARS ARE INSTALLED IN THE CELLS OF CONCRETE MASONRY UNITS, THEY SHALL BE SECURED WITH WIRE TIES AT INTERVALS NOT EXCEEDING 24" O/C TO MAINTAIN THE BARS LOCATION IN THE CELL. THE TOLERANCE FOR SPACING OF VERTICAL BARS IS ±2 INCHES ALONG THE LENGTH OF THE WALL. THE TOLERANCE FOR THE DISTANCE BETWEEN THE FACE OF THE CONCRETE MASONRY UNIT AND THE CENTER OF THE BAR SHALL NOT EXCEED±%". 14. MORTAR PROTRUSION SHALL BE LESS THAN %2'. A PROTRUSION OF %2" OR GREATER MUST BE REMOVED BEFORE GROUTING. 15. HORIZONTAL JOINT REINFORCEMENT: ASTM A82 FABRICATED FROM COLD DRAWN STEEL WIRE AND HOT DIP ZINC COATED (ASTM A153). IT SHALL CONSIST OF TWO OR MORE PARALLEL, LONGITUDINAL WIRES 0.1875" IN DIAMETER WITH WELD -CONNECTED CROSS WIRES 0.1483" IN DIAMETER AT A MAXIMUM OF 16" O/C. JOINT REINFORCEMENT IS TO BE INSTALLED IN EVERY OTHER COURSE AND IN THE FIRST TWO COURSES AT THE BOTTOM AND TOP OF WALL OPENINGS AND SHALL EXTEND NOT LESS THAN 24" PAST THE OPENING. SPLICES SHALL OVERLAP NOT LESS THAN 12". 16. EXECUTION: MASONRY UNITS SHALL BE LAID IN A RUNNING BOND PATTERN UNLESS NOTED OTHERWISE. THE WALLS SHALL BE CARRIED UP LEVEL AND PLUMB WITHIN THE TOLERANCES SPECIFIED IN ACI 530.1-88, SECTION 2.3.3.2. IF NONSTANDARD DIMENSIONS ARE ENCOUNTERED, BLOCK SHALL BE CUT WITH A MASONRY SAW TO FIT, NOT BY STRETCHING OR SHRINKING JOINTS. UNFINISHED WORK SHALL BE STEPPED BACK FOR JOINING WITH NEW WORK. TOOTHING WILL NOT BE PERMITTED EXCEPT WHERE SPECIFICALLY APPROVED. DAMAGED UNITS ARE TO BE CUT OUT AND NEW UNITS SET IN PLACE. 17. THE FILLED CELLS AND BOND BEAM BLOCKS OF REINFORCED MASONRY WALLS ARE TO BE FILLED WITH ASTM C476-91, GROUT FOR MASONRY WITH MINIMUM COMPRESSIVE STRESS OF 2,000 PSI AND SLUMP RANGE OF 8" TO 11". THE OUTSIDE FACE OF THE BOTTOM BLOCK OF EACH REINFORCED CELL IS TO BE BROKEN OUT FOR INSPECTION OF REINFORCING AND CLEAN OUT OF MORTAR DROPPINGS IN CELL. THE GROUT IS TO BE PUMPED INTO THE CELL IN MAXIMUM 5' LIFTS AND IMMEDIATELY VIBRATED TO MINIMIZE ANY VOIDING OF THE GROUT. RECONSOLIDATE EACH LIFT BY VIBRATING SEVERAL INCHES INTO THE PRECEDING LIFT BEFORE PLASTICITY IS LOST. RECONSOLIDATE THE TOP LIFT AND FILL WITH GROUT ANY SPACE LEFT BY SETTLEMENT SHRINKAGE. LUMBER GENERAL NOTES: 18. ALL COMMON FRAMING LUMBER IS TO MEET THE FOLLOWING MINIMUM SPECIFICATIONS AT 19% MOISTURE CONTENT: MATERIAL #2 SOUTHERN PINE #2 SPRUCE Fb (psi) 800 875 Ft (psi) 475 450 Fc (psi) 565 425 E (ksi) 1400 1400 19. ALL STRUCTURAL COMPOSITE LUMBER (LVL, LSL, PSL) IS TO MEET THE FOLLOWING MINIMUM SPECIFICATIONS: GIRDERS AND BEAMS (LVL, PSL) Fb (psi) 2600 Ft (psi) 2510 Fc (psi) 750 E (ksi) 2000 COLUMNS (LSL) & RIMBOARDS 1700 1400 400 1300 20. ALL GLUE LAMINATED TIMBER (GLU-LAM) IS TO MEET THE FOLLOWING MINIMUM SPECIFICATIONS: Fb Ft FcPERP E (psi) (psi) (psi) (ksi) STEEL GENERAL NOTES: GIRDERS AND BEAMS 2400 1700 740 1800 COLUMNS 1600 1550 560 1500 21. ALL W-SHAPE STRUCTURAL STEEL SHALL BE ASTM A992. SQUARE OR RECTANGULAR HSS SHAPES SHALL CONFORM TO ASTM A-500. GRADE B, ROUND HSS SHAPES SHALL CONFORM TO ASTM A-500; GRADE B, STRUCTURAL STEEL PIPE COLUMNS SHALL CONFORM TO ASTM A-501 OR ASTM A-53; TYPE E OR S, GRADE B. ALL OTHER STRUCTURAL SHAPES SHALL BE ASTM A-36. DESIGN, DETAILING, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC CODE AND DETAILING MANUAL. NO STRUCTURAL MEMBERS SHALL BE SPLICED EXCEPT AS SHOWN ON APPROVED SHOP DRAWINGS. 22. UNLESS OTHERWISE NOTED, ALL WELDS SHALL BE FILLET TYPE WITH A MINIMUM %6" LEG. WELDING ELECTRODES SHALL BE E70XX TYPE HAVING A MINIMUM ULTIMATE STRENGTH OF 70,000 PSI. WELDING WORK AND MATERIALS SHALL CONFORM TO THE AMERICAN WELDING SOCIETY WELDING CODE (AWS D.1). 23. BOLTED CONNECTIONS SHALL INCLUDE HIGH STRENGTH BOLTS CONFORMING TO ASTM A325. FOUNDATION ANCHOR BOLTS OR TIE RODS SHALL CONFORM TO ASTM A36 HAVING A MINIMUM YIELD STRENGTH OF 36,000 PSI. 24. THE WEBS OF STEEL BEAMS THAT HAVE MEMBERS FRAMING INTO THEM MUST BE PACKED OUT WITH 2X MEMBERS CUT TO FIT SECURELY BETWEEN THE FLANGES. THE BLOCKING IS TO BE SECURED TO THE STEEL BEAM WITH Z' DIAMETER BOLTS AT 24" ON CENTER STAGGERED OR OTHER PNEUMATIC FASTENERS OR SELF DRILLING SCREWS OF EQUAL STRENGTH. MEMBERS FRAMING INTO THE STEEL BEAMS MUST BE SECURED WITH PROPER HANGERS. 2X2 LEDGERS ARE ACCEPTABLE ONLY FOR ATTIC JOISTS. 25. UNLESS OTHERWISE NOTED ON THE PLAN, ALL STEEL COLUMNS THAT BEAR ON MASONRY OR CONCRETE SHALL BE CENTERED ON A SQUARE Z' THICK BASE PLATE LARGE ENOUGH TO CONTAIN FOUR Z' DIAMETER BOLTS WITH A 121' EDGE DISTANCE FROM THE CENTER OF THE BOLT TO THE EDGE OF THE PLATE AND FROM THE CENTER OF THE BOLT TO THE EDGE OF THE COLUMN. EMBED BOLTS 7" MINIMUM. 26. FABRICATOR IS RESPONSIBLE FOR THE DESIGN OF THE CONNECTIONS SHOWN ON THE STRUCTURAL DRAWINGS. GENERALLY, CONNECTIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE SCHEMATIC AND ARE INTENDED TO SHOW THE RELATIONSHIP OF THE MEMBERS. CONNECTIONS SHALL BE DESIGNED FOR ONE HALF (1/2) THE ALLOWABLE LOAD ON THE MEMBER, USING THE ASIC "ALLOWABLE UNIFORM LOAD TABLES" WITH GIVEN BEAM SPAN, OR FOR THE REACTIONS SHOWN ON THE CONTRACT STRUCTURAL DRAWINGS OR A MINIMUM OF 10 KIPS, WHICHEVER IS GREATEST. MEMBER FORCES AND REACTIONS HAVE BEEN REDUCED IN CONFORMANCE TO CODE PROVISIONS RELATED TO COMBINATIONS OF LOADINGS THAT INCLUDE WIND AND SEISMIC FORCES. NO FURTHER REDUCTIONS IN FORCES OR INCREASE IN ALLOWABLE STRESSES IS PERMITTED. CONNECTIONS MAY BE BOLTED OR WELDED UNLESS NOTED OTHERWISE. 27. ALL SHOP AND FIELD WELDING SHALL BE BYA CERTIFIED WELDER AND SHALL CONFORM TO AWS STANDARDS. 16 1 945 J N PEASE PLACE, SUITE #204 CHARLOTTE, NC 2B262 CORPORATE LICENSE #: C-31 1 B PHONE: 704-335-7200 SEAL ty y lrrri JJ '4 `. SSip.. Q SEAL 48941 i : FOR STRUCTURAL ONLY For structural questions: Cameron Lober (704)-877-9093 3600 Sadler Road Charlotte, NC 28278 ara Noi Drawn: 12/1/2021 S 0 COPYRIGHT 2021 - PROPERTY OF INTELLIGENT DESIGN ENGINEERING P.C. CONTRACTOR TO VERIFY/ADD 16"x16"x8" CONCRETE FOOTING GROUT ACROSS MASONRY GAP AND SECURE AT TOP OF MASONRY WALL w/ SIMPSON MSTAM24 MASONRY STRAP w/ GFCMU TITEN SCREWS VERIFY MIN. 8x16 MASONRY PIER OVER MIN. 20"x20"x8" CONCRETE FOOTING r L_ 1 L 3'-23 I� DECK NOT IN SCOPE OF WORK • 16,-73" eto NEW 8" CMU FOUNDATION WALL OVER CONT. CONCRETE FOOTING PER DETAIL 1/S5 X L- -711 • NEW 4" CONC SLAB W/ 6X6 io W.W.M. O/ 6 MIL POLY VAPOR BARRIER 0/ 4" POUROUS STONE 0/ COMPACTED FILL L 11 I FOOTING CONNX. /Xi/ S5 EXISTING 8" CMU FOUNDATION WALL (TYP. ) 111v/ / // V/\,/ •/x CONTRACTOR TO VERIFY MIN. 18"x8" CONT. CONCRETE FOOTING (TYP.) r '›\1 CUT BACK EXISTING MASONRY FOUNDATION WALL AND MASONRY LINTEL FOR NEW DOOR OPENING POUR NEW 4" CONC SLAB W/ 6X6 io W.W.M. O/ 6 MIL POLY VAPOR BARRIER O/ #57 STONE 0/ COMPACTED FILL w/ MIN. 2000 PSF BEARING CAPACITY 1 N- 0 1 CUT BACK SLAB AND FILL TO BUILD NEW RETAINING WALL AND FILL OVERCUT w/ #57 STONE FOOTING CONNX. • CONTRACTOR TO VERIFY MIN. 2000 PSF SOIL COMPACTION AT REAR FOUNDATION WALL EXISTING OBSTRUCTIONS AND CONCEALMENT OF SOME FRAMING ELEMENTS MAKES IT DIFFICULT TO DETERMINE THE EXACT AS -BUILT CONDITIONS AND DIMENSIONS. THESE PLANS REPRESENT OUR BEST APPROXIMATION OF THE AS -BUILT CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FRAMING ASSUMPTIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES THAT COULD IMPACT THE DESIGN. THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR THESE DISCREPANCIES OR ANY COSTS ASSOCIATED WITH REQUIRED DESIGN OR CONSTRUCTION CHANGES. PLAN LEGEND: FOOTING CONNX. SECURE NEW CONCRETE FOOTING TO EXISTING FOOTING w/ (2)-#4 BARS DOWELED 6" INTO EXISTING FOOTING AND SECURED w/ SIMPSON SET EPDXY (TYP.) SEE DETAIL 8/S5 EXISTING 8" CMU REVERSE RETAINING WALL / /.v. / / i•v CUT DOWN EXISTING MASONRY FOUNDATION WALL TO BE FLUSH WITH ADJACENT FLOOR JOISTS WHERE HATCHED F 2.0 ✓i2 SLAB (2Fo 12'-3" ■ DEMOLISH EXISTING RETAINING — WALL AND REBUILD NEW 8" CMU FOUNDATION RETAINING WALL PER DETAIL 2/S1. ADD VERTICAL REINFORCEMENT FOR A BACKFILL OF 1'-0" GREATER THAN ACTUAL BACKFILL HEIGHT. EXAMPLE: IF BACKFILL IS 4'-0", USE REINFORCEMENT FOR 5'-0" TALL WALL '71 L 2'-6" INFILL MASONRY OPENING w/ 8" CMU FOUNDATION WALL. **RECOMMEND CUTTING HOLES IN EXISTING SLAB TO TEST UNDERLYING SOIL FOR 2000PSF COMPACTION EXISTING CONCRETE SLAB S5 LEVEL EXISTING SLAB w/ NEW SELF -LEVELING CONCRETE (2" THICK MAX) /v /v /v ,v , v ,v ,v ,v ,v X A `< / X X X X X EXISTING 8" CMU FOUNDATION WALL 8" CMU RETAINING WALL OVER CONTINUOUS CONCRETE FOOTING PER DETAIL 2/S1 EXISTING 8" CMU REVERSE RETAINING WALL EXISTING CONCRETE GARAGE SLAB X EXISTING 8" CMU FOUNDATION WALL FOUNDATION NOTES: 1. CONTRACTOR TO VERIFY ALL EXISTING PERIMETER WALL FOOTINGS ARE CONTINUOUS 18"x8" MINIMUM. INFORM ENGINEER OF RECORD FOR REANALYSIS IF SMALLER FOOTINGS ARE PRESENT. 2. CONTRACTOR TO CONSTRUCT NEW FOUNDATION TO ALLOW TOP OF NEW FLOOR FOUNDATION TO ALIGN WITH TOP OF EXISTING FLOOR FOUNDATION. 3. NEW PERIMETER FOUNDATION WALLS TO BE CONTINUOUS 8" CMU UNLESS OTHERWISE NOTED. PERIMETER WALL FOOTINGS SHALL BE CONTINUOUS 20"x10" MINIMUM, 3000 PSI CONCRETE U.N.O. 4. BEARING CAPACITY OF SOIL IS ASSUMED TO BE 2000 PSF. 5. SIZE OF INTERIOR CMU PIERS DEPEND ON HEIGHT AND LOADING. UNLESS OTHERWISE NOTED AS LARGER, CMU PIERS SHALL BE: PIER 8x16 8x16 FILL HOLLOW GROUTED MAX. HEIGHT 32" 80" CONCRETE FTG 24"x36"x10" 24"x36"x10" *ALL HOLLOW PIERS AND WALLS TO HAVE TOP 8" GROUTED. 6. SLAB - NEW SLAB ON GRADE SHALL CONSIST OF 4" THICK, 3000 PSI CONCRETE WITH FIBERMESH REINFORCEMENT OR 6X6 W1.4XW1.4 WVVF. OVER 6 MIL VAPOR BARRIER OVER 4" CLEAN STONE OVER COMPACTED FILL. 7. SHIMS USED BETWEEN MASONRY PIERS AND WOOD GIRDERS SHALL CONSIST OF EITHER SOLID WOOD OR A MINIMUM OF TWO STACKS OF STEEL SHIMS EQUAL IN WIDTH TO THE GIRDER AND FULLY CONTACT AT LEAST 6" THE LENGTH OF THE PIER. FOOTING SCHEDULE: F1.5: F2: 18"X18"X8" 24"X24"X8" MAX �1 0 9 GA. LADDER WIRE @ EACH COURSE 8" CMU WITH VERT. BAR @ 16" O.C. GROUT REINFORCED CELLS SOLID BACKFILL OVER CUT WITH #57 STONE WITHIN 24" OF WALL WATERPROOFING PER BUILDER PERF. DRAIN PIPE SET IN FILTER SOCK AND WRAPPED WITH STONE. DRAIN TO DAYLIGHT OR PROVIDE WEEP HOLES IN FOUNDATION WALL EVERY 4 FT. 3" . 8a d • od.e W1 DOWEL EXTEND TO TOP OF WALL. 2" DIA. WEEPS AT 4 FT. O.C. 5- 1 w w 0 W2 1' 3" PROVIDE MIN. 6" OF COMPACTED FILL OVER TOP OF FOOTING AT TOE. 2 # 4 LONGITUDINAL BARS AT TOE 35 PCF - SLOPED BACKFILL Z = BACKFILL HEIGHT DOWEL/ VERT. BARS FOOTING W2 W1 DEPTH 'Y' 3' #4 @ 16" O.C. 3'-0" 1'-0 12" 4' #4 @ 16" O.C. 3'-6" 1'-0 12" 5' #4 @ 16" O.C. 4'-6" 1'-0 12" 6' #4 @ 16" O.C. 5'-3" 1'-0 12" 7' #5 @ 16" O.C. 6'-3" 1'-0 13" NOTES: 1. WALLS GREATER THAN 48" IN WALL HEIGHT SHALL BE INSPECTED AS REQ'D BY THE COUNTY INSPECTOR PRIOR TO POURING CONCRETE. ALL REINFORCEMENT STEEL SHALL BE TIED OFF FOR INSPECTION. 2. ALL CORNERS TO BE REINFORCED W/ #3 BARS W/ 24" LEGS @ 16" O.C. VERTICALLY 3. FILL ALL CELLS WITH CONCRETE. 2,000 PSI GROUT. 4. PROVIDE CLEANOUT HOLES AT BOTTOM BLOCKS TO ENSURE CONSOLIDATION. 5. CONCRETE MASONRY UNITS (CMU) SHALL CONFORM WITH ASTM C90 AND BE CONSTRUCTED IN ACCORDANCE WITH ACI 530. 6. SPACING FOR REBAR SHALL BE WITHIN 1" OF DIMENSION SHOWN. DISTANCE OF REBAR FROM EDGE OF WALL SHALL BE WITHIN 2". WALL AND FOOTING THICKNESS SHALL BE WITHIN 4' TOLERANCE. FOOTING WIDTHS SHALL BE WITHIN 2" TOLERANCE. KEY AND FOOTING DEPTHS SHALL BE WITHIN 1". 7. THIS WALL DESIGN IS BASED ON AN EQUIVALENT FLUID PRESSURE OF 35 PCF AND ALLOWABLE SOIL BEARING CAPACITY OF 2000 PSF AND A COEFFICIENT OF FRICTION BETWEEN THE FOOTING AND SOIL OF 0.35. A FLUID PRESSURE OF 35 PCF REPRESENTS SAND OR GRAVEL WITH LITTLE FINES AND GOOD DRAINAGE QUALITIES. IF THE ACTUAL FIELD VALUES ARE LESS FAVORABLE THAN THESE ASSUMED VALUES SUCH AS FAT CLAYS OR SIMILAR SOILS WITH POOR DRAINAGE QUALITIES, CONTACT THE ENGINEER FOR REANALYSIS, OTHERWISE BACKFILL AGAINST THE WALL WITH CLEAN STONE OR DRAINABLE FILL. 8. DO NOT USE COMPACTION MACHINES OR ENGINEERED COMPACTED FILL WITHIN 5 FT. OF THIS WALL WITHOUT WRITTEN APPROVAL FROM THE ENGINEER. ONLY CLEAN, WASHED SELF COMPACTING #57 STONE MAY BE PLACED AGAINST WALLS WHERE HARDSCAPE WILL BE PLACED ON BACKFILL SURFACE AND NO SETTLEMENT IS DESIRED. 9. THE BACKFILL SLOPE AGAINST THE WALL SHALL NOT EXCEED 1V:5H. THE SLOPE ON THE TOE (NON-BACKFILL) SIDE SHALL NOT EXCEED 1V:6H FOR A DISTANCE EQUAL TO THE HEIGHT OF THE BACKFILL. DIG FOOTING DEEPER AND INCREASE WALL HEIGHT AS NEEDED TO ACHIEVE THIS. 10. IF THE RETAINING SIDE WILL SUPPORT A DRIVEWAY, INCREASE THE WALL DESIGN A FOOT GREATER THAN THE ACTUAL RETAINING HEIGHT. 11. CONTACT THE ENGINEER IF THE WALL WILL NEED TO RETAIN A SURCHARGE LOAD FROM AN ADJACENT STRUCTURE OR POOL. 12. THE HEIGHT OF THE WALL IS MEASURED FROM THE TOP OF THE FOOTING TO THE HEIGHT OF THE BACKFILL. 2 \ 8" CMU RETAINING WALL S1 Scale: 4"=1'-0" 1 945 J N PEASE PLACE, SUITE #204 CHARLOTTE, NC 2B262 CORPORATE LICENSE #: C-31 1 8 PI -I F- 711a-7R7R S-771111 - SEAL 5ty11111111 ' 0 .SSi . oor . SEAL 48941 Up IVY !YG 1 N NC-1. . rrr111111111y5' FOR STRUCTURAL ONLY For structural questions: Cameron Lober (704)-877-9093 3600 Sadler Road Charlotte, NC 28278 Foundation Plan Drawn: 12/1/2021 Scale: 411 = 11-0" S 1 COPYRIGHT 2021 - PROPERTY OF INTELLIGENT DESIGN ENGINEERING P.C. VERIFY 2x8 @ 16" O.C. P.T. FLOOR JOISTS ADD SIMPSON HUC28-2 CONCEALED HANGER w CO x DECK NOT IN SCOPE OF WORK KNEEBRACE CO x N O O EXIST. POST VERIFY 2x8 @ 16" O.C. P.T. FLOOR JOISTS 6x6 POST NEW (2)-2x8 P ro► ':ice. �• -***** WOOD STEPS BY OTHERS w CO N O O NEW (2)-2x8 P.T. NEW 2x8 @ 16" O.C. P.T. JOISTS DECK LEDGER 0_ N z 611. REINFORCE EXIST. (2)-2x6 FLUSH GIRDER w/ NEW 14'x7q' LVL SECURED w/ (2)-ROWS OF 4" FLATLOK SCREWS @ 16" O.C. NOTCH LVL AT EACH END TO 52' MIN. TO BEAR OVER MASONRY PIERS AND FOUNDATION WALL. REINFORCE EXIST. (2)-2x6 FLUSH GIRDER w/ NEW 14"x94" LVL. NOTCH LVL AT EACH END TO 52" MIN. TO BEAR OVER MASONRY PIERS AND FOUNDATION WALL. EXIST. 2x6 @ 16" O.C. FLOOR JOISTS tio EXIST. 2x6 @ 16" O.C. FLOOR JOISTS SIMPSON HU4.75/9 HANGER X � •: REINFORCE EACH EXIST. 2x6 F.J. 0 z J w 0 z NEW DOUBLE 0 z J NEW DOUBLE UNDER REINFORCE EACH EXIST. 2x6 F.J. W DOUBLE z 10 U O O o O N O wL• 71- z NEW (2)-14'x94' LVL FLUSH ADD SIMPSON HUC28-2 CONCEALED HANGER EXISTING 2x10 @ 16" O.C. FLOOR JOISTS • REPLACE EXIST. JOISTS w/ NEW 2x10@16"0.C. FLOOR JOISTS IiEk Nir EXISTING 2x10 @ 16" O.C. FLOOR JOISTS SECURE JOISTS TO HOUSE BAND/ BEAM WITH METAL HANGERS /\/ /\ v/v 1 Pr mq • • n • 2 STUDS 2I ISTUDS NEW (2)-2x10 BELOW WALL AT LOWER LEVEL / NEW 2x10 @ 16" O.C. FLOOR JOISTS S5 ADD 2x10 BLOCKING BETWEEN JOISTS SET TOP AT MAIN LEVEL HEIGHT i TAf 4 EXISTING CONCRETE SLAB i BUILD UP 2x4 @ 16" O.C. PT STUD WALL NEXT TO EXISTING ABASEMENT WALL FOR NEW LOWER LEVEL FLOOR JOISTS TO BEAR 6x6 PT POST CUT DOWN EXISTING MASONRY FOUNDATION WALL TO BE FLUSH WITH ADJACENT FLOOR JOISTS WHERE HATCHED X X 1.1 EXISTING CONCRETE SLAB CONTRACTOR TO REMOVE EXISTING 8" CMU FOUNDATION WALL ABOVE EXISTING SLAB. INFILL SLAB CUT w/ CONCRETE AND BUILD UP NEW 2x4 @ 16" O.C. STUD WALL WATERPROOFING & FLASHING BETWEEN DECK BAND AND HOUSE BAND PER CONTRACTOR. SEAL AROUND BOLT HOLE PENETRATIONS. EXTEND FLASHING 6" MIN. ABOVE TOP OF SUBFLOOR WOOD DECKING z_ CO EXISTING RIM BAND TO REMAIN EXISTING FLOOR JOISTS TO REMAIN FASTEN 2X P.T. DECK BAND TO HOUSE BAND WITH STAGGERED a"0 BOLTS @ 16" O.C. AND 3-12D NAILS @ 8" O.C. OR SELF DRILLING SCREWS AT 6" O.C. STAGGERED. PROVIDE WASHERS BETWEEN BAND AND SHEATHING FOR DRAINAGE DECK LEDGER CONNECTION EXISTING FOUNDATION WALL TO REMAIN Scale:4"=1'-0" FRAMING NOTES: 1. TEMPORARY SUPPORT OF THE EXISTING FRAMING DURING AND AFTER DEMOLITION OF EXISTING CONDITIONS IS THE RESPONSIBILITY OF THE CONTRACTOR. 2. NEW LOAD BEARING HEADERS SHALL BE (2)2X8 SPF#2 UNLESS NOTED OTHERWISE 3. WHERE DIMENSIONS ARE NOT INDICATED, BEAMS THAT RUN PARALLEL TO FLOOR JOISTS ARE INTENDED TO ALIGN UNDER LOAD BEARING WALLS (SEE THE ARCHITECTURAL PLANS FOR DIMENSIONS TO WALLS) 4. NEW WALLS UP TO 10'-6". TALL SHALL BE A MINIMUM OF 2X4 SPF#2 @ 16" o.c. UNLESS NOTED OTHERWISE ON THE PLAN. WALLS BETWEEN 10'-6" AND 14'-2" TALL SHALL BE A MINIMUM OF 2X6 SPF#2 @ 16"o.c. UNLESS NOTED OTHERWISE ON THE PLAN. TALLER WALLS ARE SPECIFICALLY NOTED ON THE PLAN. 5. RIM BOARDS AND BANDS PARALLEL TO FLOOR FRAMING TO BE DOUBLED. DBL JOISTS OR CRIPPLES WALLS TO BE INSTALLED BETWEEN STACKING LOAD BEARING WALLS TO TRANSFER LOADING. 6. STUD SUPPORT AT EACH END OF BEAMS/HEADERS UNLESS NOTED OTHERWISE 2x LUMBER = SAME AS NUMBER PLIES FOR BEAMS; 1 FOR HEADERS LVL, PSL, GLU-LAM = 3 STEEL BEAM = 5 7. NEW POINT LOADS FROM ROOF BRACES, JACK STUDS, AND BEAM SUPPORTS MUST BE SUPPORTED WITH SOLID BLOCKING AND/OR STUDS EQUAL TO THE NUMBER OF STUDS ABOVE ALL THE WAY DOWN TO THE FOUNDATION (1 STUD/2X4 BLOCK MINIMUM) (RIM BOARDS AND I -JOIST BLOCKING SHALL NOT BE CONSIDERED AS AN ACCEPTABLE MEANS OF SUPPORT UNDER POINT LOADS FROM LVL AND STEEL BEAMS OR WHERE SQUASH BLOCKS "S.B" ARE INDICATED 8. NUMBER OF KING STUDS BASED ON OPENING WIDTH: 2x4 WALL LESS THAN < 3'-9" = 1 KING 3'-9" TO 6'-0" = 2 KINGS 6'-1" TO 10'-0" = 3 KINGS OVER 10'-1" = SEE PLAN 2X6 WALL LESS THAN < 9'-0" = 1 KING GREAT THAN > 9'-0" = SEE PLAN 9. NEW FRAMING MEMBERS TO BE SPF#2 OR SYP#2 UNLESS NOTED OTHERWISE 10. FASTEN ALL TRIPLE PLY LVLs TOGETHER WITH TWO ROWS OF 5" LONG FLATLOK OR SIMPSON SDS SCREWS @ 16" o.c. AND FOUR PLY LVLs WITH TWO ROWS OF 63/4" FLATLOK SCREWS @ 16" o.c. UNLESS NOTED OTHERWISE ON THE PLANS. THE SCREWS SHALL BE LOCATED A MINIMUM OF 2" AND A MAXIMUM OF 3" FROM THE TOP OR BOTTOM OF THE BEAM. 11. DOUBLE JOISTS CAN BE SEPARATED BY UP TO 32" TO ALLOW FOR PASSAGE OF PLUMBING PIPES AND ELECTRICAL WIRES. 12. WOOD BEAMS SHALL BE SUPPORTED BY METAL HANGERS OF ADEQUATE CAPACITY WHERE FRAMING INTO BEAMS OR LEDGERS. THE FOLLOWING HANGER SCHEDULE MAY BE USED UNLESS NOTED OTHERWISE ON THE PLAN: (HANGERS WITH EQUIVALENT CAPACITIES TO THOSE LISTED BELOW ARE ALSO ACCEPTABLE) MEMBER SIZE (2) 2X8 (2) 2X10, (2) 2X12 (3)-2x10, (3)-2x12 (2) 13/4' X 9%4" LVL (2)1%4'X117/4'-14"LVL (2) 1 A' X 16" - 24"LVL ALL TRIPLE LVLs SIMPSON HANGERS LUS 28-2 LUS 210-2 LUS 210-3 HUS 410 HUS 412 HHUS 410 HHUS 5.50/10 13. FILL ALL OF THE HOLES IN BEAM HANGERS WITH 16d x 3X" COMMON NAILS (32'x 0.162") OR 16d x22' (22'x 0.162") NAILS UNLESS OTHERWISE SPECIFIED BY THE MANUFACTURER. DO NOT BEND OR MODIFY THE HANGER OR USE INAPPROPRIATE FASTENERS. DO NOT USE 10dX 1X" "HANGER NAILS" UNLESS OTHERWISE NOTED ON THE PLANS OR IN SITUATIONS WHERE ONLY 14" OR LESS OF WOOD IS PROVIDED TO NAIL INTO. 14. CONTRACTOR RESPONSIBLE FOR ALL WATERPROOFING AND FLASHING. BRACED WALL LINE NOTE: THIS STRUCTURE HAS BEEN ANALYZED FOR LATERAL LOADING USING DIAGONAL WALL BOARD SHEATHING FOR EXISTING PORTION OF STRUCTURE. NEW PORTIONS OF THIS STRUCTURE HAVE BEEN ANALYZED FOR CONTINUOUSLY SHEATHED 6" OSB WALL SHEATHING USING 8d NAILS AT 6" o.c. ALONG EDGES AND 12" o.c. AT INTERMEDIATE FRAMING. BLOCK AND NAIL ALL PANEL EDGES. WHERE BRACED WALLS DO NOT MEET THE PRESCRIPTIVE REQUIREMENTS OF SECTION R602.10 OF THE CODE, IT HAS BEEN ANALYZED BY ENGINEERING ANALYSIS INCORPORATING ENGINEERED LATERAL BRACING ELEMENTS WHERE NEEDED TO MEET THE INTENT OF THE CODE. SEE PLANS FOR ALL NOTES AND DETAILS. PLAN LEGEND: 6x6 POST - 6x6 PT POST WITH TWO SIMPSON LCE4 CAPS AT CORNER POSTS AND TWO SIMPSON AC6 CAPS AT INTERMEDIATE POSTS (BLOCK AS NEEDED). IF WOOD FRAMING BELOW, SECURE WITH SAME CAPS AT BOTTOM; IF CONC. OR MASONRY BELOW, SECURE WITH SIMPSON ABW66Z BASE WITH i" x6" TITEN HD ANCHOR SCREW OR EQUAL. KNEEBRACE OR K.B. - 6x6 PT KNEE BRACE INSTALLED PER APPENDIX M IN CODE OR PLAN DETAILS. DECK LEDGER - SECURE DECK JOISTS TO 2x PT BAND WITH METAL HANGERS. SECURE BAND TO HOUSE BAND WITH $"0 GALV. CARRIAGE BOLT AT 16"o.c. AND THREE 12D NAILS AT 8"o.c. EXISTING OBSTRUCTIONS AND CONCEALMENT OF SOME FRAMING ELEMENTS MAKES IT DIFFICULT TO DETERMINE THE EXACT AS -BUILT CONDITIONS AND DIMENSIONS. THESE PLANS REPRESENT OUR BEST APPROXIMATION OF THE AS -BUILT CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FRAMING ASSUMPTIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES THAT COULD IMPACT THE DESIGN. THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR THESE DISCREPANCIES OR ANY COSTS ASSOCIATED WITH REQUIRED DESIGN OR CONSTRUCTION CHANGES. 15. INTELLIGENT DESIGN ENGINEERING 1 945 J N PEASE PLACE, SUITE #204 CHARLOTTE, NC 28262 CORPORATE LICENSE #: C-31 1 8 PHONE: 704-335-7200 SEAL 40 i 1111 iJ 4} SEAL 48941 - f, GiN 0 t ,ti lrilrl111111hV FOR STRUCTURAL ONLY For structural questions: Cameron Lober (704)-877-9093 3600 Sadler Road Charlotte, NC 28278 Basement Level Framing Plan Drawn: 12/1/2021 Scale: 41' = 11-011 S2 COPYRIGHT 2021 - PROPERTY OF INTELLIGENT DESIGN ENGINEERING P.C. ADD 2x6 @ 16" O.C. CEILING JOISTS ADD (3)-2x4 BALLOON FRAMED STUDS UP TO LVL RIDGE NEW 2x4 @ 16" O.C. STUDS FRAMED FROM BOTTOM PLATE TO VAULTED CEILING 4 (2)-2x8 HDR 3 KINGS 2 JACKS NEW (2)-2x10 HEADER H O 3 KINGS 2 JACKS NEW (2)-14"x94' LVL HEADER ADD 3 JACKS VAULTED C 0 0 0 EILING 1 JACK 2 KINGS VERIFY/ADD (2)-2x8 HEADER 0 — EXTEND HEADER TO BEAR OVER WALL BELOW ADD 3 JACKS ADD 3 STUDS ADD 3 STUDS U O 0 z N J w U z 1 JACK 2 KINGS ADD 3 STUDS NEW (2)-14" x11$" LVL DROPPED ADD 3 v UDS O 1 (FULL HEIGHT) (2)-2x8 HEADER J z //// • — ADD 2 NEW KINGS UP TO NEW TOP PLATE CUT LOWER DOUBLE TOP PLATE TO FASTEN NEW 2x4 @ 16" O.C. STUD SECTION TO THE SIDE OF EXISTING STUDS w/ (2)-8d NAILS @ 3" O.C. PER DETAIL 2/S3 (TYP.) 6x6 POST CO w CO CO w L0 i�//A 1- J 5 m (D z 1- co X w X z BALLOON FRAME NEW 2x4 @ 16" O.C. STUD WALL FROM NEW MAIN LEVEL FOUNDATION WALL UP TO CEILING AT TRUSSES NEW (2)'x8 HDR 0 w w w 0 0 0 z U 0 w x w z 3LEAR SPAN NEW (2)-2x10 HDR U O EXISTING BUILT-UP ROOF TRUSSES @ NEW 16' OSB SHEATHING CUT EXIST SHEATHING 12" BELOW TOP PLATE. NAIL NEW OSB TO STUD AND BLOCKING WITH (4)-8D NAILS 12 NEW 2x4 CONT. STUD FASTENED TO EACH EXISTING STUD w/ (2)-8d NAILS @ 3" O.C. (TYP.) EXISTING KNEEWALL OVER LOWER WALL ADD 2X4 BLOCKING FOR SHEATHING NAILING 1" (MAX) EXISTING WALL TO REMAIN EXISTING WALL EXTENSION CUT DOUBLE TOP PLATE FOR NEW 2x4 EXTENSION STUD z \S3 NEW (2)-14"x11$" LVL HEADER Scale: a"=1'-0" EW (2)-2 HDR \ ADD 2 STUDS VAULTED CEILING 4x4 POST UP TO RIDGE NEW (2)-2x1 DROPPED NEW (2)-2x10 DROPPED ADD 3 JACKS ADD 2 STUDS EXISTING HEADER EXISTING BUILT-UP ROOF TRUSSES @ 24" O.0 L SIMPSON HUC210-2 CONCEALED HANGER. INSTALL HANGER PRIOR TO SETTING BEAM ADD 2 STUDS 6x6 POST = NEW (2)-2x8 HDR ADD 3 JACKS EXISTING HEADER EXISTING BUILT-UP ROOF TRUSSES @ 24" O.0 1 � NEW /�/���.#—. i (2)-2x8 HDR / / / / / / / / / / / / / / 2 KINGS 1 JACK U 0 w CO CO 1- w 0 0 0_ 1- J 5 co (D z EXISTING HEADER BUILD NEW WALL BENEATH EXISTING HEADER. STRAP STUDS ACROSS HEADER w/ SIMPSON LSTA24 VERTICAL STRAPS (TYP.) HDR. PER PLAN NOTCH POST TO RECEIVE HDR & FASTEN WITH (2)412) BOLTS CENTERED ON POST POST PER PLAN POST -TO -BEAM DETAIL S3 Scale: a"=1'-0" FRAMING NOTES: 1. TEMPORARY SUPPORT OF THE EXISTING FRAMING DURING AND AFTER DEMOLITION OF EXISTING CONDITIONS IS THE RESPONSIBILITY OF THE CONTRACTOR. 2. NEW LOAD BEARING HEADERS SHALL BE (2)2X8 SPF#2 UNLESS NOTED OTHERWISE 3. NEW WALLS UP TO 10'-6". TALL SHALL BE A MINIMUM OF 2X4 SPF#2 @ 16" o.c. UNLESS NOTED OTHERWISE ON THE PLAN. 4. WALLS BETWEEN 10'-6" AND 14'-2" TALL SHALL BE A MINIMUM OF 2X6 SPF#2 @ 16"o.c. UNLESS NOTED OTHERWISE ON THE PLAN. TALLER WALLS ARE SPECIFICALLY NOTED ON THE PLAN. STUD SUPPORT AT EACH END OF BEAMS/HEADERS UNLESS NOTED OTHERWISE 2x LUMBER = SAME AS NUMBER PLIES FOR BEAMS; 1 FOR HEADERS LVL, PSL, GLU-LAM = 3 STEEL BEAM = 5 5. NEW POINT LOADS FROM ROOF BRACES, JACK STUDS, AND BEAM SUPPORTS MUST BE SUPPORTED WITH SOLID BLOCKING AND/OR STUDS EQUAL TO THE NUMBER OF STUDS ABOVE ALL THE WAY DOWN TO THE FOUNDATION (1 STUD/2X4 BLOCK MINIMUM) (RIM BOARDS AND I -JOIST BLOCKING SHALL NOT BE CONSIDERED AS AN ACCEPTABLE MEANS OF SUPPORT UNDER POINT LOADS FROM LVL AND STEEL BEAMS OR WHERE SQUASH BLOCKS "S.B" ARE INDICATED 6. NUMBER OF KING STUDS BASED ON OPENING WIDTH: 2x4 WALL LESS THAN < 3'-9" = 1 KING 3'-9" TO 6'-0" = 2 KINGS 6'-1" TO 10'-0" = 3 KINGS OVER 10'-1" = SEE PLAN 2X6 WALL LESS THAN < 9'-0" = 1 KING GREAT THAN > 9'-0" = SEE PLAN 7. NEW FRAMING MEMBERS TO BE SPF#2 OR SYP#2 UNLESS NOTED OTHERWISE 8. WOOD BEAMS SHALL BE SUPPORTED BY METAL HANGERS OF ADEQUATE CAPACITY WHERE FRAMING INTO BEAMS OR LEDGERS. THE FOLLOWING HANGER SCHEDULE MAY BE USED UNLESS NOTED OTHERWISE ON THE PLAN: (HANGERS WITH EQUIVALENT CAPACITIES TO THOSE LISTED BELOW ARE ALSO ACCEPTABLE) MEMBER SIZE (2) 2X8 (2) 2X10, (2) 2X12 (3)-2x10, (3)-2x1 2 (2)13/4"X9%4"LVL (2)13/4"X117/4"-14"LVL (2) 13/4" X 16" - 24"LVL ALL TRIPLE LVLs SIMPSON HANGERS LUS 28-2 LUS 210-2 LUS 210-3 HUS 410 HUS 412 HHUS 410 HHUS 5.50/10 9. FILL ALL OF THE HOLES IN BEAM HANGERS WITH 16d x 3X" COMMON NAILS (32"x 0.162") OR 16d x22" (22"x 0.162") NAILS UNLESS OTHERWISE SPECIFIED BY THE MANUFACTURER. DO NOT BEND OR MODIFY THE HANGER OR USE INAPPROPRIATE FASTENERS. DO NOT USE 10dX 1%2" "HANGER NAILS" UNLESS OTHERWISE NOTED ON THE PLANS OR IN SITUATIONS WHERE ONLY 1i" OR LESS OF WOOD IS PROVIDED TO NAIL INTO. 10. CONTRACTOR TO PROVIDE 22"x30" MIN. ACCESS TO ATTIC AREAS MORE THAN 400 SF. 11. CONTRACTOR RESPONSIBLE FOR ALL WATERPROOFING AND FLASHING. 12. SEE ARCHITECTURAL PLANS FOR ALL DIMENSIONS. BRACED WALL LINE NOTE: THIS STRUCTURE HAS BEEN ANALYZED FOR LATERAL LOADING USING DIAGONAL WALL BOARD SHEATHING FOR EXISTING PORTION OF STRUCTURE. NEW PORTIONS OF THIS STRUCTURE HAVE BEEN ANALYZED FOR CONTINUOUSLY SHEATHED 16" OSB WALL SHEATHING USING 8d NAILS AT 6" o.c. ALONG EDGES AND 12" o.c. AT INTERMEDIATE FRAMING. BLOCK AND NAIL ALL PANEL EDGES. WHERE BRACED WALLS DO NOT MEET THE PRESCRIPTIVE REQUIREMENTS OF SECTION R602.10 OF THE CODE, IT HAS BEEN ANALYZED BY ENGINEERING ANALYSIS INCORPORATING ENGINEERED LATERAL BRACING ELEMENTS WHERE NEEDED TO MEET THE INTENT OF THE CODE. SEE PLANS FOR ALL NOTES AND DETAILS. PLAN LEGEND: 6x6 POST 6x6 PT POST NOTCHED FOR NEW BEAM TO BEAR. SECURE BEAM TO POST w/ (2)-5/8" 0 CARRIAGE BOLTS PER DETAIL ?. SECURE POST TO FOOTING WITH SIMPSON ABW66Z BASE WITH 2"Ox6" TITEN HD ANCHOR SCREW OR EQUAL. SEE DETAIL 3/S3 EXISTING OBSTRUCTIONS AND CONCEALMENT OF SOME FRAMING ELEMENTS MAKES IT DIFFICULT TO DETERMINE THE EXACT AS -BUILT CONDITIONS AND DIMENSIONS. THESE PLANS REPRESENT OUR BEST APPROXIMATION OF THE AS -BUILT CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FRAMING ASSUMPTIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES THAT COULD IMPACT THE DESIGN. THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR THESE DISCREPANCIES OR ANY COSTS ASSOCIATED WITH REQUIRED DESIGN OR CONSTRUCTION CHANGES. 15. 1 945 J N PEASE PLACE, SUITE #204 CHARLOTTE, NC 2B262 CORPORATE LICENSE #: C-31 1 8 PHONE: 704-335-7200 Sty hY11111 t Q SEAL . 48941 '4F !GIN co. y�y% f, �' +`+11111ikk O' SEAL FOR STRUCTURAL ONLY For structural questions: Cameron Lober (704)-877-9093 3600 Sadler Road Charlotte, NC 28278 1 Level and per Level Drawn: 12/1/2021 Scale: 411 = 11-011 S3 COPYRIGHT 2021 - PROPERTY OF INTELLIGENT DESIGN ENGINEERING P.C. 0 O w'- z@ x NEW BEAM BELOW CO w 1- w Q BEAR RAFTERS OVER BEAM BELOW co w 1- w o 0 X z NEW (2)-10:14" LVL STRUCTURAL RIDGE O.C. RAFTERS x z co w 1- u_ w O z0 x NEW BEAM BELOW BEAR RAFTERS OVER BEAM BELOW 0 O CO �1J CO CO 1- w 0 0 w R EXISTING BUIL w 1- w X z z 2x6 RAFTER SECURED TO HOUSE STUDS w/ (2)-3R" LEDGERLOK SCREWS @ 16" O.C. (TYP.) SECURE ALL RAFTERS TO BEAM BELOW w/ SIMPSON H2.5A CLIPS OR EQUAL o 0 w'- z X x NEW (2)-2x6 0 O co X w z 6 RAFTER w Q X z USSES @ 24" O.0 SECURE ENDS OF TRUSSES TO WALL PLATE w/ SIMPSON H2.5A CLIPS OR EQUAL (TYP.) 0 CO LLI CO NEW 2x10 STRUCTURAL CO RIDGE BRACED DOWN TO (2)-2x12 BEAM BELOW AND u_ SECURED TO ADJACENT 0 TRUSS TOP CHORDS ON —0 EACH END w/ (3)-8d TOENAILS III II 0III EIII w cr-1 III III NEW I 11 A 2x6 @ 16" O.C. I I oUI di III NEW wII 2x6 @ 16" O.C. COI I o N cD E Q D U_,c III RAFTERS } BEAM BELOW} D co RAFTERS ifII IIN 4x4 POST BRACE DOWN TO BEAM BELOW EXISTING BUILT-UP NEW BEAM BELOW EXISTING BUILT-UP ROOF TRUSSES @ 24" O.0 L EXISTING BUILT-UP ROOF TRUSSES @ 24" O.C. SECURE ENDS OF TRUSSES TO WALL PLATE w/ SIMPSON H2.5A CLIPS OR EQUAL (TYP.) SECURE ALL RAFTERS TO BEAM BELOW w/ SIMPSON H2.5A CLIPS OR EQUAL SECURE ENDS OF TRUSSES TO WALL PLATE w/ SIMPSON H2.5A CLIPS OR EQUAL (TYP.) ROOF CONSTRUCTION NOTES: 1. NEW RAFTERS SHALL BE 2X6 SPF#2 @ 16" o.c. UNLESS NOTED OTHERWISE 2. SECURE EXISTING ROOF TRUSSES TO DOUBLE TOP PLATE w/ SIMPSON H2.5A CLIPS OR EQUAL 3. NEW HIPS, VALLEYS, AND RIDGES ARE 2X10 SPF#2 UNLESS NOTED OTHERWISE 4. ALL SHADED OR HATCHED AREAS INDICATE ROOF OVERBUILDS 5. STRUCTURAL RIDGE - FASTEN NEW RAFTERS INTO THE STRUCTURAL RIDGE BEAMS WITH: * (3) 3"X 0.131" TOE -NAILS FOR SPANS UP TO 8 FT. * (3) 3"X 0.131" TOE -NAILS AND A BEVELED 2x LEDGER, OR SIMPSON A34 OR L50 ANGLE OVER 8 FT. 6. IN ADDITION TO THE CODES FASTENER SCHEDULE, UNLESS NOTED OTHERWISE ON THE PLAN, INSTALL SIMPSON H2.5A HURRICANE CLIPS AT THE ENDS OF THE RAFTERS WHERE THEY BEAR ON THE WALL PLATE @ 48" o.c. INSTALLING OVER WALL SHEATHING IS ACCEPTABLE. AT OPEN FRAMED ROOFS, SUCH AS PORCHES, INSTALL HURRICANE CLIPS AT EACH RAFTER. 7. NEW ROOF BRACES MUST HAVE A STUD FROM PLATE THROUGH ALL FLOORS TO THE FOUNDATION OR SUPPORTING BEAM BELOW. 8. ROOF BRACES UNDER 7'-0" ARE 2-2X4 NAILED WITH 3"X 0.131"NAILS @ 6" o.c. VERTICALLY FROM TOP TO BOTTOM. BRACES LONGER THAN 7'-0" SHALL CONSIST OF (2)2X6 T-BRACES. BRACES LONGER THAN 12 FT. MUST BE BRACED HORIZONTALLY IN TWO DIRECTIONS AT MID -HEIGHT. 9. CONNECT BOTTOMS OF NEW BRACES THAT ARE NOT WITHIN 26° FROM VERTICAL TO BEAMS OR WALLS WITH ONE SIMPSON A34 BRACKET, OTHERWISE CONNECT WITH FOUR 3"X 0.131" TOENAILS. ROOF PLAN LEGEND: BB - BEAM BELOW RB - RAFTERS BEAR ON WALL BELOW 0 INDICATES LOCATION OF ROOF BRACE POINT AT RAFTER LEVEL. ®j ARROWAWAY FROM THE BRACE POINT INDICATES DIRECTION OF ROOF BRACE TO PARTITION, BEAM, OR OTHER BRACE POINT BELOW. 0< ARROW INTO BRACE POINT INDICATES A VERTICAL OR ALMOST VERTICAL ROOF BRACE TO PARTITION, BEAM, OR OTHER BRACE POINT BELOW. RAFTER BAN D - SECURE 2X BAND (ONE SIZE LARGER THAN RAFTER) TO HOUSE STUDS/BAND WITH 3-16D NAILS AT 16"o.c. SECURE EACH RAFTER TO BAND WITH 3-8D TOENAILS AND SUPPORT WITH SIMPSON A34 OR L50 SIDE ANGLE OR BEVELED 2x LEDGER. EXISTING OBSTRUCTIONS AND CONCEALMENT OF SOME FRAMING ELEMENTS MAKES IT DIFFICULT TO DETERMINE THE EXACT AS -BUILT CONDITIONS AND DIMENSIONS. THESE PLANS REPRESENT OUR BEST APPROXIMATION OF THE AS -BUILT CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FRAMING ASSUMPTIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES THAT COULD IMPACT THE DESIGN. THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR THESE DISCREPANCIES OR ANY COSTS ASSOCIATED WITH REQUIRED DESIGN OR CONSTRUCTION CHANGES. 16. 1 945 J N PEASE PLACE, SUITE #204 CHARLOTTE, NC 2B262 CORPORATE LICENSE #: C-31 1 8 PHONE: 704-335-7200 SEAL t5y1111111 Q` SEAL 48941 Stir lei .: f,¢!YG I Nt-,C? f l V 1 ! ��77 +1}Il lllylyl FOR STRUCTURAL ONLY For structural questions: Cameron Lober (704)-877-9093 3600 Sadler Road Charlotte, NC 28278 Roof Framing Plan Drawn: 12/1/2021 Scale: 41' = 11-011 S4 COPYRIGHT 2021 - PROPERTY OF INTELLIGENT DESIGN ENGINEERING P.C. WALL HEIGHT UNBALANCED FILL FOOTING V=VERTICAL BARS & DOWELS FOOTING REINF. W1 W2 W3 0' TO 2'-8" 6" 6" 20" SOLID GROUTED N/A 2'-8" TO 4' 8" 12" 28" # 4 @ 16" O.C. 2-#4 REBAR 6 MIL. POLY ACROSS TOP OF TOP COURSE OF BLOCK & FLASHING W/ WEEPS BRICK VENEER OR FINISH PER BUILDER 9 GA. LADDER JOINT REINFORCEMENT EVERY OTHER COURSE 4"0 PERFORATED DRAIN PIPE SET IN GRAVEL (WHERE REQ'D) CONTINUOUS CONC. FOOTING, IF NEEDED, PER CHART (3000 PSI) • WALL HEIGHT c E \ W1 W2 8" CMU FOUNDATION WALL W3 3" 4" CONC. SLAB WITH 6x6 10/10 W.W.M OR FIBER REINFORCEMENT OVER 6 MIL. POLY. VAPOR BARRIER OVER 4" POROUS STONE OVER SOLID SOIL V=VERTICAL BARS WATERPROOF MEMBRANE PER CONTRACTOR 8" CMU BLOCK (SOLID GROUTED) FOUNDATION WALL VERIFY NUMBER OF COURSES V=DOWELS IF MASONRY STAIRS COVERS MORE THAT 60% OF WALL LENGTH, THEN WALL REINFORCEMENT IS NOT REQUIRED. Scale: a"=1'-0" DEMO EXISTING 8" CMU FOUNDATION WALL ABOVE SLAB POUR SELF -LEVELING CONCRETE OVER EXISTING SLAB TO FLATTEN FLOOR TO A MAX OF 2" THICK. EXISTING CONCRETE SLAB EXISTING FOOTING NEW SLAB OVER EXISTING WALL EXISTING CONCRETE SLAB EXISTING MASONRY FOUNDATION WALL S5 Scale: a"=1'-0" NEW 2x4 @ 12" O.C. STUD WALL NEW FLASHING PER CONTRACTOR ADD NEW 2x6 PT PLATE FILL TOP COURSE SOLID WITH GROUT OR MORTAR. EXIST. 8" CMU FOUNDATION WALLS CONTRACTOR TO VERIFY MIN. 18"x8" EXISTING CONCRETE FOOTING 2" EXPANSION JOINT FLASHING PER CONTRACTOR IC) NEW 4" CONC. SLAB W/ W1.4x1.4 WWF O/ 6 MIL POLY VAPOR BARRIER 0/ 4" POROUS STONE WATERPROOFING MEMBRANE PER CONTRACTOR EXISTING FOOTING IC) -IJ N Tr fO' �C4 v at • for? NEW SLAB OVER EXISTING WALL NEW 4" CONC. SLAB W/ W1.4x1.4 WWF 0/ 6 MIL POLY VAPOR BARRIER 0/ 4" POROUS STONE EXISTING MASONRY FOUNDATION WALL S5 Scale: a"=1'-0" IN LIEU OF a"0 BOLTS, (3)-10" LONG TIMBER-LOK SCREWS CAN BE USED 6X6 P.T. POST w/ (2) SIMPSON LCE4 POST CAPS NOTCH LVL TO 52" MIN. TO BEAR OVER MASONRY PIERS AND FOUNDATION WALL AT EACH END. BEAM PER PLAN 00 LLJ Al cn= 0_w P.T. 6X6 KNEE BRACE FASTENED TO BEAM AND 6X6 POST USING (1) 2"0J GALV. CARRIAGE BOLTS WITH SQUARE WASHER ON BOTH SIDES OF BRACE (BRACE DIM. SAME ALL LEGS) SIMPSON ABW66Z POST BASE W/ 2' Q ANCHOR BOLT CONC FTG PER PLAN 6x6 PT KNEEBRACES S5 Scale: a"=1'-0" NEW 2x4 P.T. PLT. W/ DIAMTER ANCHOR BOLTS AT 72" O.C. 12" FROM CORNERS W/7" MINIMUM EMBEDMENT IN SOLID GROUTED COURSE 2' T&G PLYWOOD OVER FLOOR JOISTS PER PLAN. (BLOCK BETWEEN JOISTS RUNNING PARALLEL TO FOUNDATION WALL ©24" O.C. FOR THREE CONSECUTIVE JOISTS SPACINGS) BLOCK BETWEEN JOISTS RUNNING PARALLEL TO WALL @ 24" O.C. w/ 2x10 FOR THREE CONSECUTIVE JOIST SPACINGS. TOENAIL BLOCKING TO 2x10 JOISTS W/ 3-8D NAILS. SECURE BLOCKING TO FLOOR SHEATHING W/ ROW OF 2" LONG #10 SCREWS OR 8D NAILS @ 6" O.C. NEW 2x10 PT BAND SECURED TO EXIST. BASEMENT WALL w/ a"x3" TAPCON SCREWS @ 16" O.C. WATERPROOFING MEMBRANE PER CONTRACTOR NEW 4" CONC. SLAB WITH 6x6 10/10 W.W.M OR FIBER REINFORCEMENT OVER 6 MIL. POLY. VAPOR BARRIER OVER POROUS STONE OVER SOLID SOIL ADD NEW 4" CMU FOUNDATION WALL UP AGAINST EXISTING FOUNDATION WALL OVER EXIST. FOOTING FOR NEW SLAB TO BEAR NOTE: 1. FILL REINFORCED CELLS WITH CONCRETE. CONCRETE SHALL BE 3,000 PSI AT 28 DAYS. THE USE OF AN ADMIXTURE TO FACILITATE CONSOLIDATION OF CONCRETE IS RECOMMENDED, IN ADDITION TO VIBRATION. 2. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 318. PROVIDE CLEANOUT HOLES AT BOTTOM BLOCKS TO ENSURE CONSOLIDATION. 3. REINFORCEMENT SHALL BE GRADE 60 4. SPACING FOR REBAR SHALL BE WITHIN 1" OF DIMENSION SHOWN. DISTANCE OF REBAR FROM EDGE OF WALL SHALL BE WITHIN 2". 5. EXISTING CMU BASEMENT WALL LOOKS TO BE IN GOOD CONDITION. ANALYSIS OF THE EXISTING BASEMENT WALL WAS NOT COMPLETED DUE TO THE UNKNOWN NATURE OF THE WALL CONSTRUCTION.THIS WALL DESIGN IS BASED ON AN ASSUMED EQUIVALENT FLUID PRESSURE OF 45 PCF, ALLOWABLE BEARING CAPACITY OF 2000 PSF EXISTING BASEMENT WALL REINF. AT FRONT DOOR Scale: a"=1'-0" EXTEND NEW FLOOR SHEATHING 12" MIN. OVER EXISTING FLOOR JOISTS EXISTING FLOOR JOISTS PER PLAN EXIST. 8" CMU FOUNDATION WALLS CONTRACTOR TO VERIFY MIN. 18"x8" EXISTING CONCRETE FOOTING EXISTING GRADE. VERIFY 2000 PSF BEARING PRESSURE ADD NEW 2x PLATES TO FLUSH NEW FLOOR LEVEL w/ EXISTING FLOOR LEVEL 2' T&G PLYWOOD OVER FLOOR JOISTS PER PLAN. (BLOCK BETWEEN JOISTS RUNNING PARALLEL TO FOUNDATION WALL ©24" O.C. FOR THREE CONSECUTIVE JOISTS SPACINGS) NEW 2x10 BLOCKING BETWEEN FLOOR JOISTS WATERPROOFING MEMBRANE PER CONTRACTOR NEW 2x4 @ 16" O.C. P.T. STUD WALL FILL w/ #57 STONE EXISTING MASONRY PIER EXISTING CONCRETE FOOTING REINFORCE EXIST. (2)-2x6 FLUSH GIRDER w/ NEW 14'x94' LVL. WRAP LVL TO WATERPROOF PER BUILDER SIDE VIEW REINFORCED EXISTING GIRDER EXISTING FLOOR JOISTS PER PLAN EXISTING MASONRY PIER EXISTING CONCRETE FOOTING SECTION VIEW S5 EXISTING STUD WALL NEW 2x10 BLOCKING BETWEEN FLOOR JOISTS NEW 4" CONC. SLAB WITH 6x6 10/10 W.W.M OR FIBER REINFORCEMENT OVER 6 MIL. POLY. VAPOR BARRIER OVER POROUS STONE OVER SOLID SOIL ADD NEW 4" CMU FOUNDATION WALL UP AGAINST EXISTING FOUNDATION WALL OVER EXIST. FOOTING FOR NEW SLAB TO BEAR NOTE: 1. FILL REINFORCED CELLS WITH CONCRETE. CONCRETE SHALL BE 3,000 PSI AT 28 DAYS. THE USE OF AN ADMIXTURE TO FACILITATE CONSOLIDATION OF CONCRETE IS RECOMMENDED, IN ADDITION TO VIBRATION. 2. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 318. PROVIDE CLEANOUT HOLES AT BOTTOM BLOCKS TO ENSURE CONSOLIDATION. 3. REINFORCEMENT SHALL BE GRADE 60 4. SPACING FOR REBAR SHALL BE WITHIN 1" OF DIMENSION SHOWN. DISTANCE OF REBAR FROM EDGE OF WALL SHALL BE WITHIN 2". 5. EXISTING CMU BASEMENT WALL LOOKS TO BE IN GOOD CONDITION. ANALYSIS OF THE EXISTING BASEMENT WALL WAS NOT COMPLETED DUE TO THE UNKNOWN NATURE OF THE WALL CONSTRUCTION.THIS WALL DESIGN IS BASED ON AN ASSUMED EQUIVALENT FLUID PRESSURE OF 45 PCF, ALLOWABLE BEARING CAPACITY OF 2000 PSF 10 EXISTING BASEMENT WALL REINFORCEMENT S5 Scale: a"=1'-0" EXIST. 8" CMU FOUNDATION WALLS CONTRACTOR TO VERIFY MIN. 18"x8" EXISTING CONCRETE FOOTING EXISTING GRADE. VERIFY 2000 PSF BEARING PRESSURE Scale: a"=1'-0" IAI 0 III A i I At Q v REPLACE DAMAGED AND ROTTEN JOISTS EXISTING SHEATHING OVER EXISTING FLOOR JOISTS EXISTING STUD WALL WATERPROOFING MEMBRANE PER CONTRACTOR FILL w/ #57 STONE CONTINUOUS CONCRETE FOOTING PER PLAN O F- Qw o EMBED NEW #4 BARS 6" INTO EXISTING CONCRETE FOOTING @ 6" O.C. WITH SIMPSON "SET" EPDXY OR EQUAL EXISTING ASSUMED CONCRETE FOOTING NEW -TO -EXISTING FOOTING DETAIL S5 EXISTING STUD WALL NEW 2x10 BLOCKING BETWEEN FLOOR JOISTS POUR SELF -LEVELING CONCRETE OVER EXISTING SLAB TO FLATTEN FLOOR TO A MAX OF 2" THICK. NEW 4" CONC. SLAB WITH 6x6 10/10 W.W.M OR FIBER REINFORCEMENT OVER 6 MIL. POLY. VAPOR BARRIER OVER POROUS STONE OVER SOLID SOIL ADD NEW 4" CMU FOUNDATION WALL UP AGAINST EXISTING FOUNDATION WALL OVER EXIST. FOOTING FOR NEW SLAB TO BEAR NOTE: 1. FILL REINFORCED CELLS WITH CONCRETE. CONCRETE SHALL BE 3,000 PSI AT 28 DAYS. THE USE OF AN ADMIXTURE TO FACILITATE CONSOLIDATION OF CONCRETE IS RECOMMENDED, IN ADDITION TO VIBRATION. 2. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 318. PROVIDE CLEANOUT HOLES AT BOTTOM BLOCKS TO ENSURE CONSOLIDATION. 3. REINFORCEMENT SHALL BE GRADE 60 4. SPACING FOR REBAR SHALL BE WITHIN 1" OF DIMENSION SHOWN. DISTANCE OF REBAR FROM EDGE OF WALL SHALL BE WITHIN 2'. 5. EXISTING CMU BASEMENT WALL LOOKS TO BE IN GOOD CONDITION. ANALYSIS OF THE EXISTING BASEMENT WALL WAS NOT COMPLETED DUE TO THE UNKNOWN NATURE OF THE WALL CONSTRUCTION.THIS WALL DESIGN IS BASED ON AN ASSUMED EQUIVALENT FLUID PRESSURE OF 45 PCF, ALLOWABLE BEARING CAPACITY OF 2000 PSF EXISTING BASEMENT WALL REINFORCEMENT Scale: a"=1'-0" EXISTING CONCRETE SLAB. EXIST. 8" CMU FOUNDATION WALLS CONTRACTOR TO VERIFY MIN. 18"x8" EXISTING CONCRETE FOOTING EXISTING GRADE. VERIFY 2000 PSF BEARING PRESSURE Scale: a"=1'-0" 0 Q 0 0) Iv REPLACE DAMAGED AND ROTTEN JOISTS EXISTING SHEATHING OVER EXISTING FLOOR JOISTS EXISTING STUD WALL WATERPROOFING MEMBRANE PER CONTRACTOR FILL w/ #57 STONE NEW 4" CONC. SLAB WITH 6x6 10/10 W.W.M OR FIBER REINFORCEMENT OVER 6 MIL. POLY. VAPOR BARRIER OVER POROUS STONE OVER SOLID SOIL ADD NEW 4" CMU FOUNDATION WALL UP AGAINST EXISTING FOUNDATION WALL OVER EXIST. FOOTING FOR NEW SLAB TO BEAR NOTE: 1. FILL REINFORCED CELLS WITH CONCRETE. CONCRETE SHALL BE 3,000 PSI AT 28 DAYS. THE USE OF AN ADMIXTURE TO FACILITATE CONSOLIDATION OF CONCRETE IS RECOMMENDED, IN ADDITION TO VIBRATION. 2. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 318. PROVIDE CLEANOUT HOLES AT BOTTOM BLOCKS TO ENSURE CONSOLIDATION. 3. REINFORCEMENT SHALL BE GRADE 60 4. SPACING FOR REBAR SHALL BE WITHIN 1" OF DIMENSION SHOWN. DISTANCE OF REBAR FROM EDGE OF WALL SHALL BE WITHIN 2'. 5. EXISTING CMU BASEMENT WALL LOOKS TO BE IN GOOD CONDITION. ANALYSIS OF THE EXISTING BASEMENT WALL WAS NOT COMPLETED DUE TO THE UNKNOWN NATURE OF THE WALL CONSTRUCTION.THIS WALL DESIGN IS BASED ON AN ASSUMED EQUIVALENT FLUID PRESSURE OF 45 PCF, ALLOWABLE BEARING CAPACITY OF 2000 PSF 12 EXISTING BASEMENT WALL REINFORCEMENT S5 Scale: a"=1'-0" 16 1 945 J N PEASE PLACE, SUITE #204 CHARLOTTE, NC 2B262 CORPORATE LICENSE #: C-31 1 B PHONE: 704-335-7200 4y k L1.11+ q¢ SEAL 48941 " f fr'I,, jy 0' SEAL FOR STRUCTURAL ONLY For structural questions: Cameron Lober (704)-877-9093 3600 Sadler Road Charlotte, NC 28278 tru ctu ra l Details Drawn: 12/1/2021 Scale: 411 = 1I-0" S5 COPYRIGHT 2021 - PROPERTY OF INTELLIGENT DESIGN ENGINEERING P.C.