HomeMy WebLinkAboutNC0005321_Compliance Evaluation Inspection_19950601. -( (`,,\t State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., PE., Director June 1, 1995 Mr. Ronald Radford Alpha Cellulose Corporation P.O. Box 1305 Lumberton, NC 28358 V I-1NIF 1, - • EM Vi MAN!'1NEMEN FAYETTEVIla REG. OFFICEj SUBJECT: Initial Laboratory Certification Inspection ' Dear Mr. Radford: Enclosed is a copy of the subject inspection report as prepared by Ms. Cooper. Each of the deviations must be corrected prior to certification. Within sixty days, please supply this office with a written item for item description of how these deviations were corrected. As a certification requirement, your laboratory must continue to carry out the requirements set forth in NCAC 15R 2H .0800. Thank you for your cooperation during the inspection. Please contact us at 919-733-3908 if you have questions or need additional information. Sincerely, William B. Edwards', Jr. Laboratory Section Enclosure cc: Norman L. Good Harvi Cooper Fayetteville Regional Office /gwt a� e tIa rof ,1 6 1995 it��AGEF��i Laboratory Section 4405 Reedy Creek Road, Raleigh, North Carolina 27607-6445 Telephone 919-733-3908 FAX 919-733-6241 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper ON -SITE INSPECTION REPORT LABORATORY NAME & ADDRESS: Alpha Cellulose Corporation P.O. Box 1305 Lumberton, NC 28358 CERTIFICATE NO.: DATE OF INSPECTION: May 24, 1995 TYPE OF INSPECTION: Initial EVALUATORS: Harvi C. Cooper LOCAL PERSON CONTACTED: Chuck Oxendine and Ronald Radford I. INTRODUCTION: This laboratory requirements of samples. was inspected to verify its compliance with the 15A NCAC 2H .0800 for the analysis of environmental II. GENERAL COMMENTS: Lab is spacious and well equipped. Instruments and facilities are well maintained. Records are well kept and data looked good. A few minor deviations were found and some further quality control procedures need to be implemented. III.DEVIATIONS, REQUIREMENTS AND COMMENTS: BOD Deviation: Lab is not currently checking BOD effluent samples for residual chlorine and dechlorinating when necessary. Requirement: Lab must check all BOD samples for residual chlorine and dechlorinate as required in Standard Methods 18th Edition and document the process. Residual Chlorine Deviation: The lower reporting limit for Residual Chlorine is below the lowest calibration standard analyzed. Lab is currently calibrating with a 1.0 and a 10.0 mg/L standard. Page 2 Alpha Cellulose Residual Chlorine contd. Requirement: For analytical procedures requiring analysis of a series of standards, the concentration of these standards must bracket the concentration of the samples analyzed. One of the standards must have a concentration equal to the laboratory's lowerlreporting concentration for the parameter involved. Comment: Lab has established 0.01 ug/L as the lower reporting concentration for Residual Chlorine. Lab is currently using anion selective electrode due to color interferences in the effluent. Documentation of the lab's ability to meet this established lower reportingconcentration must be submitted to this office for review. Deviation: The daily 1.0 mg/L check standard for Residual Chlorine is often outside the + 10% acceptance criteria. Requirement: A daily mid -range check standard must meet a + 10% acceptance criteria. Specific Conductance Deviation: Lab has not documented the required calibration standards for Specific Conductance analyses. Requirement: Each day of use, the Conductivity meter must be calibrated with a high standard, the cell constant must be calculated and the process documented. A low and mid -range standard must also be analyzed and the results documented. Comment: Lab has developed a new bench sheet for the calibration records for pH, Conductivity and TDS, but has not documented all of the required standards for Conductivity. Considering the range of concentrations of samples analyzed, it is recommended to use a 10,000 umhos/cm standard in order to bracket sample concentrations as required. Ammonia Deviation: Ammonia samples are not checked for dechlorinated at the time of sampling. chlrine and Requirement: Lab must check samples to be analyzed.for Ammonia for chlorine, treat with an approved dechlorinating agent where necessary at the time of sampling and document the process. Comment: Lab is collecting a composite sample to be used for several analyses. Recommend splitting a sample for Ammonia analyses and dechlorinating immediately following the 24 hr. composite period. 3 Page(3 Alpha Cellulose Deviation: Lab is not each group of Ammonia Requirement: Lab must each group of Ammonia documenting the analysis of a reagent blank with samples. document the analysis of a reagent blank with samples. Deviation: Lab is omitting the distillation procedure for Ammonia analysis but has not conducted the distillationl comparison study required to document that the distillation step; is unnecessary for a particular waste stream. • Requirement: Lab must submit a copy of the distillation comparison study to this office for review. This is required if the distillation step is not conducted as part of the ammonia analyses. Comment: Lab may contract with a commercial lab to conduct the distillation part of the comparison study on each waste stream that the distillation step will be excluded from in Ammonia analysis. Enclosed is a memo on the distillation comparison requirement. Total Suspended Residue Deviation: Lab is not analyzing a quarterly check s Suspended Residue. tandard for Total Requirement: Lab must analyze -and indicate the true' value and percent recovery of a Total Suspended Residue check standard quarterly. General Deviation: Lab is using pencil to record data on bench sheets. Requirement: Lab must use ink for all documentationL. If corrections are made, a slash must be drawn through the error and the analyst must initialthe correction. Deviation: Lab has not documented refrigerator temperatures on the refrigerator log. Requirement: Lab must record temperatures and initial the temperature log each day of use, for all refrigerators, incubators and ovens.ref: 15A NCAC 2H .0805 (7)(J) pcq.7 Deviation: All lab thermometers are not calibrated against a NIST certified thermometer annually. Degree deviations are not listed tag on the thermometers. on a Requirement: All thermometers must meet NIST specifications for accuracy or must be calibrated against a NIST certified thermometer annually and proper corrections made. Ref: 15A NCAC 2H .0805 (7)(0) pg. 7 Page 4 Alpha Cellulose Comment:. Lab has calibrated some of the thermometers but has done so at approximately 20°C for all thermometers calibrated. A temperature within the range that the individual thermometers are required to operate should be selected for calibration. IV. DATA REVIEW: Data review consisted of a.review of the bench sheets and DMR's for the -months of September 1994 thru March 1995. No problems in adhering to required hold times or in properly calculating data were detected. . CONCLUSION: This lab is doing a good job overall. Personnel contacted were cooperative and competent. Documentation of the correction of the 'above deviations mustbe submitted to this office for review. Correction of the above deviations should help this lab continue to produce quality data. Report Prepared by: Harvi C. Cooper Date: May 28, 1995