Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0040266_Wasteload Allocation_19821207
NPDES DOCIMENT SCANNIN`: COVER SHEET NPDES Permit: NC0040266 Knightdale Estates WWTP Document Type: Permit Issuance (aste1oad Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Technical Correction Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: December 7, 1982 This document is printed on reuse paper - ignore any content on the reYerse side w cu Facility Name: E c� Existing Proposed a) y= O NPDES WASTE LOAD ALLOCATION )6, ic, 7,4 Lc,- Date 10-14 LV Permit No.: oVeoo 40 Z(e (7. Pipe No.: 00-i County- 6C/.O,e6- Design Capacity (MGD) : 0• D / 2 s Industrial (% of Flow) : Domestic (% of Flow) : /00 YJ Receiving Stream: (AT Pkc.I5 ��c/1- Class: C_ Sub -Basin: Q-59-°7 - O Z- .�� Reference USGS Quad: (Please attach) Requestor• ff✓r ' 2 Reg}enal Office "IV Cc (Guideline limitations, if applicable, are to be listed on the back of this form.) Design Temp.: r)q o Drainage Area 02,0 r,-) a Avg. Streamflow: 7Q10: 1C-5 Winter 7Q10: 30Q2- ^� Location of D.O.minimum (miles below outfall) : Slope•. ( t"�r a> a) cn a) U cu CU Velocity (fps): 0, K1 (base e, per day, 20°C): K2 (base e, per day, 20°C)• Effluent Characteristics Monthly Average Comments 005 30r Q. T55 30Q,. tat. Got + prrll (WI) A)0m 2- Original Allocation Rev ed Allocation cfr CO/ rEff luent Characteristics Monthly Average �U" Date(s) of Revision(s) [ C (Please attach previous allocation) LKxtc•Ick, kP Comments Prepared By: 040.4.4:4.. Reviewed By: i/(1 Date: I L) REQUEST NO. : 466 RW ********************* WASTELOAD ALLOCATION APPROVAL FORM ********************* FACILITY NAME TYPE OF WASTE COUNTY REGIONAL OFFICE RECEIVING STREAM 7010 : 0.1 CFS DRAINAGE AREA : • • • • KNIGHTDALE MHP DOMESTIC: WAKE RALEIGH UT NEUSE RIVER W7010 : 2.00 S0.MI. CFS 1�k-.C3-19Q2 WATER QUALITY „,,,a! BFFiCE OPERA[ku' S BRANCH REOUESTOR RAVE ADKINS SUBBASIN : 030402 3002 : STREAM CLASS tC CFS ************************ RECOMMENDED EFFLUENT LIMITS ************************ WASTEFLOW(S) BOD-5 NH3--N D.Q. PH FECAL COLIFORM TSS (MGD) (MG/L) : (MG/L) : (MG/L) : (SU) (/100ML): (MG/L) 0.0125 30 NR NR 6-9 1000 30 KNIGHTDALE MHP WAS PREVIOUSLY CALLED BULLUCKS MHP. ******************************************************************************** FACILITY IS : PROPOSED ( LIMITS ARE : REVISION ( ) EXISTING () NEW ( ) ) CONFIRMATION ( ) OF THOSE PREVIOUSLY ISSUED REVIEWED AND RECOMMENDED BY: MODELER SUPERV'ISOR,MODELING GROUP REGIONAL SUPERVISOR PERMITS MANAGER APPROVED BY : DIVISION DIRECTOR DATE : _ ! 14 aU DATE t J113V/.. IATE : 2ZAZA __DATE : _%z..�.�/1.z-_ G4u-4 111301a2-- •• 71-44-P — 'WI -"1-u- - -c 4 ....> W 44 guitt.4 4 k., vumf Cc.a i 1 _--- .. M+tf 0.017ri ©s1-7 71t o e• 0.1 'rho = 70 13A'iiceav2 -Qs-_0, 'DA .O ' ( 0 - — au:! a A' i. o 2,4 = o.l 0.0 lso - - -- - Dl012,c 122 ./s0 --=Ile 5.11, , - I(v ..75 1y O ( a 0 55- 5,0 5.0 ********** MODEL RESULTS ********** DISCHARGER :KNIGHTDALE MHP RECEIVING STREAM :UT NEUSE RIVER ****************************************** C*************************** THE END D.O. IS 7.63 MG/L ********************************************************************** THE END CBOL► IS 1.99 MG/L ********************************************************************** THE END NBOI► IS 0.00 MG/L ********************************************************************** THE D.O. MIN. OF SEGMENT 1 IS 6,22 MG/L THIS MINIMUM IS LOCATED AT SEGMENT MILEPOINT 0.2 WHICH IS LOCATED IN REACH NUMBER 1 THE WLA FOR SEGMENT 1 REACH 1 IS 110 MG/L OF CBOD THE WLA FOR SEGMENT 1 REACH 1 IS 0 MG/L OF NBOD THE REQUIRED EFFLUENT D,0, IS 0 MG/L THE WASTEFLOW ENTERING SEG 1 REACH 1 IS 0.0125 MGD THE WLA FOR SEGMENT 1 REACH 2 IS 2 MG/L OF CBOT► THE WLA FOR SEGMENT 1 REACH 2 IS 0 MG/L OF NBOD THE REQUIRED EFFLUENT D.0, IS 7.56 MG/L THE WASTEFLOW ENTERING SEG 1 REACH 2 IS 45,22 MGD ********************************************************************** *** MODEL SUMMARY DATA *** DISCHARGER RECEIVING STREAM 7010 DESIGN TEMPERATURE . . • , , . KNIGHTDALE MHP UT NEUSE RIVER 0.1 CFS 25 DEGREES C. SUBBASIN t 030402 STREAM CLASS: C WINTER 7010 : CFS WASTEFLOW : 0,0125 MGD ILENGTHISLOPE I VELOCITY (DEPTH 1 Ki 1 Kr 1 Kri 1 K2 1 Oro 1 (MILES IFT/MI 1 FPS 1 FT t /DAY /DAY 1/DAY 1/DAY (CFS/MII SEGMENT 1 REACH 1 1 1 2.001 16.01 1 I 0,10 1 0,38 1 0.54 1 0.54 1 0.00 1 3.21 1 0,10 SEGMENT 1 REACH 2 1 0.501 1 1 1 1 1 1 1 I 3,81 1.93 1 1.56 1 0.64 1 0.64 1 0.00 1 7.10 1 0.00 1 1 1 1 1 1 t ALL RATES ARE AT 25 DEGREES C.