Loading...
HomeMy WebLinkAboutNC0081370_Approval_20010119NPDES DOCUNENT :MCANNIN` COVER !;c1EET NC0081370 Claremont / McLin Creek WWTP NPDES Permit: Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Approval Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: January 19, 2001 This; document is printed on reuse paper - ignore any content on the reYerse side OFV‘1 A T••i9 Michael F. Easley QG Govemor r William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources 'C Kerr T. Stevens, Director Division of Water Quality January 19, 2001 MR. M. DEAN MCGINNIS CITY MANAGER CITY OF CLAREMONT POST OFFICE BOX 446 CLAREMONT, NORTH CAROLINA 28610 Subject: Short Term Monitoring Plan and Sewer Use Ordnance Modifications, City of Claremont, NPDES# NC0081370 Catawba County Dear Mr. McGinnis: „ The Pretreatment Unit of the Division of Water Quality received copies of the revised Short Term Monitoring Plan and an amendment to the Sewer Use Ordnance on October 14, 1999. These documents were misfiled and recently found. We apologize for this mistake. The review indicates that both the Short Term Monitoring Plan and Sewer Use Ordnance are adequate and satisfy requirements of 15A NCAC 2H .0900 and 40 CFR 403. The Division's review process assures that the permit(s), Allocation Table, Headworks Analysis, (HWA), and other supporting documents, have been properly placed in the Division's files and that key information is entered and updated in the state's database where they are maintained for public record. On January 8, 2001, Mr. Tony Gragg of the Water Tech Company called Keyes McGee of the Pretreatment Unit Staff to report that some STMP sampling had not been done. This sampling was unfortunately discontinued during the transition from city operations to contract operations of the McLin Wastewater Treatment Plant (WWTP) by the Water Tech Company. Your. approved STMP, calls for quarterly monitoring for all influent and effluent Parameters of Concern (POCs). During the year preceding the Headworks Analysis (HWA) the sampling frequency increases to monthly. The Town of Claremont should immediately resume the STMP monitoring. STMP sampling must be completed once for the first two quarters of 2001 and increased to monthly starting in June 2001. This data is necessary for technically based local limits and HWA which is due July 21, 2002. After completion of a good HWA the STMP sampling can revert to quarterly monitoring. NC —DEAR, DWQ, PRETREATMENT UNIT 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Website: http://h2o.enr.state.nc.us/Pretreatlindes.html NCDENR Telephone: 919-733-5083 Fax: 919-715-2941 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper Please submit to the Division by September 1, 2001, a summary of your STMP, DMR, and sludge data collected to date in preparation for HWA calculations. The data will be reviewed by the Pretreatment Unit to determine if it is organized properly for use in completing the HWA. The Pretreatment Unit received today IUP coversheets for Alcatel and Pierre Foods from the City of Claremont. This submission is appreciated and the corrected pages will be collated into the filed permits for the public record. Thank you for your continued cooperation with the Pretreatment Program. If you have any questions or comments, please contact Keyes McGee at (919) 733-5083 extension 580 or Tom S. Poe, Supervisor of the Pretreatment Unit (ext. 522). Sincerely, Kerr T. Stevens _cr Path: ADSHARE\Claremont\LETTERSI Claremont STMP_SUO 008.doc cc: Tony Gragg, Pretreatment Coordinator, City of Claremont John Lesley, MRO Central Files TKM, Pretreatment Unit CITY OF CLAREMONT P.O. Box 446 3301 EAST MAIN STREET CLAREMONT, N.C. 28610 828/459-7009 • FAX 828/459-0596 October 8, 1999 Mr. Tom Poe Division of Water Quality 1625 Mail Service Center Raleigh, N.C. 27626 Dear Tom: j/lI3 - srsil° qL /y_ Sao Enclosed are copies of the revised Short Term Monitoring Plan and an amendment to our Sewer Use Ordinance. We changed the level of mercury from 0.0003 to 0.0002 in Section I Detection Level And Sampling Method. Ordinance No. 324-99 changes three sections of our Code of Ordinances governing wastewater pretreatment. Please call me at 828-459-7009 if you need additional information. Cordially, M.D. McGinnis City Manager SHORT TERM MONITORING PLAN City of Claremont, N.C. NPDES Permit No. NC0081370 McLin Creek WWTP June 20, 1996 REVISED OCTOBER 4, 1999 Prepared by: Rothrock Engineering P.O. Box 3236 Hickory, NC 28603 (704) 322-1516 A. SAMPLING POINTS (See Figure 1) 1. Influent (prior to mixing with side streams) 2. Effluent 3. Activated Sludge from Aeration Basins 4. Sludge to Disposal 5. SIU No. N001 - WSMP, Inc. 6. SIU No. M002 - Alcatel B. POLLUTANTS OF CONCERN (POC) 1. NPDES limited and monitored pollutants required. 2. For Land Application 40CFR503 Pollutants - As, Cd, Cr, Cu, Pb, H Mb Ni, Se, Zn, % solids, sludge to disposal flow. g' ' 3. EPA Required: Cd, Cr, Cu, Ni, Pb, and Zn. 4. SIU permitted pollutants required with exception of organics. 5. Pollutant exceptions: DO, pH, temperature, conductivity, oil & ease fecal colliform, aquatic toxicity, and TTO. ' C. DETENTION TIMES The aeration basin, clarifier and sand filter detention time during typical flow pperiod hours. Therefore, samples from point 2 will be taken 24 hours aftsamples is t21 taken. from point 1 are D. FLOW Flow monitoring points are indicated on the attached facility diagram (see Figure 1 will be monitored during sampling events. Flow #2 will be monitored quarterly. )' Flow # 1 E. SIU MONITORING Significant Industrial User (SIU) monitoring will be conducted per SIU permit. F SEPTAG Septage is not accepted at this facility. 2 G, SAMPLING FREQUENCY Sampling Pt. 1 - Influent, 2 - Effluent 3 - Aeration Basin 4 - Sludge to Disposal 5 - SIU #N001 WSMP 6 - SILT #M002 First Year Monthly on Workday and per NPDES requirement 1 per 6 mo. Per sludge permit and 503 regs. Per SIU permit Per SIU permit H. SAMPLING PLAN POC Flow BOD TSS % Solids Ammonia-N As Cd Cr Cu Cyanide Floride Pb Hg Mo Ni Se Ag Zn Pt. 1 Pt. 2 X X X X X kkkXkXkkkkkkkk kkXkkkkkkXXkXk Thereafter Quarterly on Workday and per NPDES requirement 1 per 6 mo. per sludge permit and 503 regs. Per SIU permit Per SIU permit Pt.3 Pt.4 X X X X X X X X X X X X X X X 3 1 Year Before HWA Monthly on Workday and per NPDES requirement 1 per 6 mo. per sludge permit and 503 regs. Per SIU permit Per SIU penult I. DETECTION LEVEL AND SAMPLING METHOD POC Detection Level (mg/1) Sample Method BOD 1.0 24 hr. composite TSS 0.1 24 hr. composite Ammonia-N 0.5 24 hr. composite As 0.01 24 hr. composite Cd 0.002 24 hr. composite Cr 0.005 24 hr. composite Cu 0.01 24 hr. composite Cyanide 0.01 Grab Floride 0.2 24 hr. composite Pb 0.01 24 hr. composite Hg 0.0002 24 hr. composite Mo 0.1 24 hr. composite Ni 0.01 24 hr. composite Se 0.01 24 hr. composite Ag 0.005 24 hr. composite Zn 0.01 24 hr. composite Sampling, preservation, and analytical methods must be from 40 CFR 136. Sludge to disposal shall be grab samples. FIGURE 1 - FACILITY DIAGRAM MCLIN CREEK WWTP CLAREMONT, N.C. NPDES PERMIT NO. NC0081370 SEQUENCING BATCH REACTOR (SBR) / AEROBIC DIGESTOR Influent Bar Screen/Grit Removal Pump Station ›- Tertiary Filter Chlorine Contact SAMPLING POINTS 1 - Influent 2 - Effluent 3 - Aeration Basin (SBR) 4 - Sludge to Disposal Batch Reactors Flow Metering Aerobic Digestors Supernatant Waste Sludge > Dechlorination 5 Cascade Aeration Sludge Disposal Stream