Loading...
HomeMy WebLinkAboutWI0501074_Injection Event Record_20220112RECEIVED MAR 2 4 2022 North Carolina Department of Environmental Quality — Division of Water Resources INJECTION EVENT RECORD (IERR NC DEg1DW►i Central Office Permit Number W10501074 . Permit Information Schlage Lock Company LLC Permittee Former Schlage Lock Plant Facility Name 213 Red Iron Rd., Rock), Mount. NC. 27804, Nash County Facility Address (include County) Injection Contractor Information Michael Gerber/ Cascade Injection Contractor / Company Name Street Address: 3020 Avondale Mill Rd. Macon City GA State 31216 Zip Code (_951)743-5497 Area code — Phone number . Well Information Number of wells used for injection 102 DPT Temporary Injection Points — No well casing installed Well IDs: See Table 1 Were any new wells installed during this injection event? ® Yes ❑ No If yes, please provide the following information: Number of Monitoring Wells 0 Number of injection Wells 102 DPT Temporary Injection Points — No well casing installed Type of Well Installed (Check applicable type): ❑ Bored ❑ Drilled ® Direct -Push ❑ Hand -Augured ❑ Other (specify) 4. 5. Please include a copy of the GW-I 1 orm for each well installed Were any wells abandoned during this injection event? / 1 Yes ❑ No If yes, please provide the following information: Number of Monitoring Wells 0 Number of injection Wells 102 DPT Temporary Injection Points — No well casing: installed Please include a copy of the GW-30 for each well abandoned Injectant Information ABC. ABC+ KB-1 Plus, Magnesium Hydroxide, Sodium Bicarbonate, Sodium Sulfite, KB-1 Primer. Amounts summarized in Table 2 Injectant(s) Type (can use separate additional sheets if necessary Concentration Products received and batched to final concentrations described in Table 3 If the injectant is diluted please indicate the source dilution fluid Potable Water — Cis), of Rock), Mount Total Volume Injected (gal) 307,382 Volume Injected per well (gal) See Table 1 Injection History Injection date(s)_ 1 / 12/20221 to 2/26/2022 Injection number (e.g. 3 of 5) 1 (No follow up injections planned at this time: post injection monitoring results will be used to determine if future injections are required) Is this the last injection at this site? ► , Yes ❑ No Submit the original of this form to the Division of Water Resources within 30 days of injection. Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-807-6464 Form UIC-IER Rev. 3-1-2016 I DO HEREBY CERTIFY THAT ALL THE INFORMATION ON THIS FORM IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE INJECTION WAS PERFORMED WITHIN THE STANDARDS LAID OUT IN THE PERMIT. 3/21/2022 SIGNATURE OF INJECTION CONTRACTOR DATE Michael Gerber PRINT NAME OF PERSON PERFORMING THE INJECTION Submit the original of this form to the Division of Water Resources within 30 days of injection. Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-807-6464 Form UIC-IER Rev. 3-1-2016 Table 1 - Well IDs and Volumes Former Schlage Lock Company Rocky Mount, North Carolina CHA8509 Geosyntec Consultants ABC Aquifer Injection Area Well ID (DPT Injection Location) Minimum Total Volume Injected per DPT Injection Location 1 gals) Maximum Total Volume Injected per DPT Injection Location (gals) Middle HC1 HC1-01, HC1-02, HC1-03, HC1-04, HC1-05, HC1-06 T 2,338 5,108 HC2 HC2-12, HC2-14, HC2-15, HC2-16, HC2-17, HC2-18, HC2-19, HC2-20, HC2-21, HC2-22, HC2-23, HC2-25, HC2-30 2,359 3,696 HC3 HC3-05, HC3-06, HC3-07, HC3-08 HC3-09, HC3-10, HC3-11, HC3-12, HC3-13, HC3-14, HC3-15 2,305 3,227 DG1 DG1-01, DG1-02, DG1-03, DG1-04, DG1-05, DG1-06, DG1-07, DG1-08, DG1-09, DG1-10, DGI-11, DGI-12, DG1-13, DG1-14 1,696 3.150 Lower HC1 HC1-01, HC1-02, HC1-03, HC1-04, HC1-05, HC1-06 2,305 2,766 HC2 HC2-03, HC2-04, HC2-05, HC2-06, HC2-11 1,296 3,948 HC3 HC3-01, HC3-02, HC3-08 HC3-09, HC3-10 3,688 3,688 HC4 HC4-01, HC4-02, HC4-03 3,786 4,205 DGl DGI-06, DG1-07, DG1-08, DGI-09 4,200 4,244 DG2 DG2-01, DG2-02, DG2-03, DG2-04 2,613 2,615 DG3 DG3-01, DG3-02, DG3-03, DG3-04, DG3-05, DG3-06, DG3-07, DG3-08, DG3-09, DG3-10, DG3-11, DG3-12 2,610 3,152 ABC+ Aquifer Injection Area Well ID (DPT Injection Location) Minimum Total Volume Injected per DPT Injection Location i uals l Maximum Total Volume Injected per DPT Injection Location E gals; Middle HC2 HC2-01, HC2-02, HC2-03, HC2-04, HC2-05, HC2-06. HC2-07. HC2-08. HC2-09, HC2-10, HC2-11 2,384 3,136 HC3 HC3-01, HC3-02, HC3-03, HC3-04 1,490 2,060 Lower HC3 HC3-03, HC3-04, HC3-07 2,376 _ 3,144 Notes: 1. gals indicates gallons. 2. DPT indicates direct push technology. 3. DG indicates downgradient injection areas. 4. HC indicates high concentration injection areas 5. Total volume is the summation of the volume of diluted carbon amendment and chase water injected at each injection location. 1 of 1 Table 2 - Materials Injected Former Schlage Lock Company Rocky Mount, North Carolina CHA8509 Geosyntec Consultants Material Injected Amount Unit ABC 94,054 lb ABC+ (ABC and ZVI) 43,460 lb Sodium Bicarbonate 46,950 lb Magnesium hydroxide 4,500 lb Sodium Sulfite 214 lb KB-1 Primer 856 lb KB-1 Plus 46.2 L Notes: 1. lb indicates US pounds. 2. L indicates liters. 3. ABC+ is a 1 to 1 (by weight) mixture of ABC and zero-valent iron (ZVI). 1 of l Table 3 - Summary of Injectant Concentrations Former Schlage Lock Company Rocky Mount, North Carolina CHA8509 Geosyntec Consultants Material: ABC Injection Solution Area Aquifer Concentration of ABC (lb/gal) Comment ABC 1:20 HC and DG Middle and Lower 0.41 ABC was diluted with potable water to the concentrations shown. ABC+ 1:10 HC Middle and Lower 0.82 ABC+ 1:15 HC Middle and Lower 0.55 Anaerobic Chase Water No ABC Added to Anaerobic Chase Water Material: Zero Valent Iron (ZVI) Injection Solution Area Aquifer Concentration of ZVI (lb/gal) Comment ABC 1:20 No ZVI Added to ABC 1:20 injection Solution ABC+ 1:10 HC Middle and Lower 0.82 Concentration reduced partway through injections ABC+ 1:15 HC Middle and Lower 0.55 Anaerobic Chase Water No ZVI Added to Anaerobic Chase Water Material: Magnesium Hydroxide Injection Solution Area Aquifer Concentration of Magnesium Hydroxide (lb/gal) Comment ABC 1:20 No Magnesium Hydroxide Added to ABC 1:20 Injection Solution ABC+ 1:15 HC Middle 0.131 Lower 0.021 ABC+ 1:10 HC Middle 0.196 Lower 0.032 Anaerobic Chase Water No Magnesium Hydroxide Added to Anaerobic Chase Water Material. Sodium Bicarbonate Injection Solution Area Aquifer Concentration of Sodium Bicarbonate (lb/gal) Comment ABC 1:20 HC Middle 0.274 Lower 0.082 DG Middle 0.572 Lower 0.073 ABC+ 1:10 No Sodium Bicarbonate Added to ABC+ 1:10 Injection Solution. ABC+ 1:15 No Sodium Bicarbonate Added to ABC+ 1:15 Injection Solution. Anaerobic Chase Water No Sodium Bicarbonate Added to Anaerobic Chase Water Material: Sodium Sulfite Injection Solution Area Aquifer Concentration of Sodium Sulfite (lb/gal) Comment ABC 1:20 HC and DG Middle and Lower 0.0012 to 0.0005 Concentration reduced partway through injections ABC+ 1:10 HC and DG Middle and Lower . 0.0012 to 0.0005 ABC+ 1:15 HC and DG Middle and Lower 0.0012 to 0.0005 Anaerobic Chase Water No Sodium Sulfite Added to Anaerobic Chase Water Material: KB-1 Primer Injection Solution Area Aquifer Concentration of KB-1 Primer (lb/gal) ABC 1:20 IIC and DG Middle and Lower 0.00175 ABC+ 1:10 ITC and DG Middle and Lower 0.00175 ABC+ 1:15 HC and DG Middle and Lower 0.00175 Anaerobic Chase Water 11C and DG Middle and Lowers 0.007 Material: KB-1 Plus Injected Directly - No Dilution of TSB-1 Plus Notes: 1. Four injection solutions were batched and injected. These included a diluted ABC solution, two diluted ABC+ solutions, and anaerobic chase water. 2. 1:10, 1:15, and 1:20 indicate the mixing ration of ABC to potable water that was used to batch the diluted ABC solutions used during injections. 3. Ib/gal indicates pound per gallon, 4. DG indicates downgradient injection areas. 5. HC indicates high concentration injection areas 1 of 1 WELL_ABANDONMENT RECORD For humnal Use ONLY: 1. Wed Coatneeter IrMrmativa: Daniel Carr Ferrell Well Coawactar Nana (ar well owner persomily abandoning well on huller properly) NCWC 3221-8 NC Well Contractor Certification Number Cascade Environmental Company Nemo 2. WeeComtrrettaa Permit# UIC IM0501074 Um all applicable well constructionpeiarih r e. UIC, Camay, Stare, variance, etc) if brown 3. Wee use (the&k well use): Water Supply Wee: ❑Aglicuhural ❑Gwtl:amal (Heating/Cooling Supply) ❑haduslriaIJComme cial ❑ '_• - ion Non -Water Supply Wen: ❑Monitoring Injection Welt ❑Aquifer Recharge ['Aquifer Storage and Recovery ❑Aquifer Test ❑Experimental Technologyy, ❑ceothenal (Closed Loop) ❑Gcopbantal f[cdi Cmolin QMunicipallPublic ❑Residential Water Supply (single) ['Residential Water Supply (slated) ❑Recovery INGrouodwater Reurediation ❑Salinity Barrier ❑Stormwater Drainage ['Subsidence Control ❑Tracer Return) ❑Other .. , ain under 7 4. Date *Otis) abandoned:2/2 5/2022 • Wen IIscadou: Former Schlage Lock Plant FacilitylOwniar Name Facility mY (ifapeieabk) 213 Red Iron Road, Rocky Mount, NC 27804 Physical Address, City, and Zip Nash County 019708, 034658 Panel idenalca ion No. IPiN) Sb. Latitude and Iaoptade iia de lmineteafaeeoads or decimal degrees: (ifweil 1ie1d on; Wong is wlFiciert) N W CONSTRUCTION IJ TAILS co -WELLIES) BEING ABANDONED Admit well oawiwcsiarrecord()ifaauilable. For mwhi*i ectionornon-leateremppIywe$a ONLY with Ube scope catrsmeraowa6dndonarear. yaw wit nitwit: deepen,. 6s Well um See Table 1 6b. Total well depth: 22 t0 550 .. -(ft) 6c. Borehole tearneter: 2 (ia.) lid Water level below ground surface: 10 t0 15 _ Aft) 6e. Omer codas length (if Iowa):N/A IA 6E inner as ltabiag length (if la•ow.) - - 6g. Screen length (if known): NIA Form GW-30 __I MO WELI1 ABANDONMENT DETAILS 7a. For Ceoprobe/DPT or Closed -Loop Geothermal Weis having the same well construction/depth, only 1 OW-30 is nmdcd. Indicate TOTAL NUMBER of wells abandoned: to2,eporaytgetJn taease,e 7b. Approximate volume of water remeiairg in 'milk): NIA l2al.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing smu ri ills used (theekall that apply): ❑ Neat Cement Grout ❑ Sand Cement Giota O Concrete crag ❑ Specialty Gran ❑ Bentonite Slurry Pi BentoniteChips orPellets ❑ Thy Clay ❑ Drill Cuttings 0 Gravel 0 Other (explain wader 7g) 7E For each material selected above, provide amount of materials ased: Approximately 2-3 bags 7g. Provide a brief description of the abandonment procedure Baahmae chips WHO poured dewrt,ale. nPT'Leong was used to push chips to depth *ram rest. Webs added to hydrate. Agohonel chips and water were added* allow chbe to seat to eutace. B. Certification SigtmttaeofCodified WdIC Owner By signing Oats form, 1 hereby cerrlfy that the wells) was (were) abandoned in accordance with 15.4 NCAC 02C .0100 or 2C _02110 Well Constrarchon Standards and theta copy of this reared hal beenprovdded to the we9awner. 9. Site diagram oar additional well details: You may use the bade of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS Ilia. For All Wells: Submit this form within 30 days of completion of well abandonment to die following; Division of W:ter Resources, Information Processing Unit, 1617 Mall Service Center, Raleigh, NC 27699-1617 19k For IaleetiprRWells: In addition to sending the farm to the address is IOa above, also submit one copy of this farm within 30 days of completion of well abandaunent to the following: Division of Water Resources, Underground ligation Control Program, 1tt"i. 6 Mail Sender Center, Raleigh, NC 27699-1636 life For Water Suueiv & laiedioa Welk: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. RECEIVED North Carolina Depantent ofEnvtmnrneatel Quality - Diviaioa of Wets Resources MAR 2 4 2022 Revised 2-22-2016 Central Office