HomeMy WebLinkAboutWM0501482_Permit (Issuance)_20220519ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
NORTH CAROLINA
Environmental Quality
May 19, 2022
Gary Fisher
Nokia of America Corporation
600 Mountain Avenue
Murry Hill, NJ 07974
Subject: Monitoring Well Construction
Permit # WM0501482
Alcatel Former
1200 Wake Towne Drive.
Raleigh, NC -Wake County
Dear Mr. Fisher:
In accordance with the application received on May 5, 2022, we are forwarding herewith
Monitoring Well Construction Permit No. WM0501482 dated May 19, 2022, issued for the construction of
a monitor well system (installation of two wells) at the subject property (621 E. Six Forks Road). Please
be aware that some counties have well construction programs, and you may be required to obtain a
well construction permit before installation.
This Permit will be effective from the date of its issuance and shall be subject to the conditions and
limitations as specified therein. Please note the addition of stipulation #3 to the permit enclosed. If you have
any questions about this permit, please contact Eric Rice at (919) 791-4242.
Sincerely,
Scott Vinson, Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Enclosure
cc: RRO Files/Laserfiche
Wake County Health Department
Email: bonani.langan@.woodplc.com Wood E&IS, 4021 Stirrup Creek Drive, Durham, NC
North CRzolina Department of Environmental Quality r Division of Water Resources
512 North Salisbury Street F l6i I Mail Service Center k Raleigh, North Carolina 27699-1611
919.707.9000
NORTH CAROLINA
DEPARTMENT OF ENVIRONMENTAL QUALITY
DIVISION OF WATER RESOURCES
PERMIT FOR THE CONSTRUCTION OF A MONITORING WELL
In accordance with the provisions of Article 7, Chapter 87, North Carolina General Statutes, and other applicable Laws,
Rules and Regulations.
PERMISSION IS HEREBY GRANTED TO
Nokia of America Corporation
FOR THE CONSTRUCTION OF A MONITOR WELL SYSTEM (Alcatel Former) consisting of two monitoring wells
owned by Nokia of America Corporation at mailing address 600 Mountain Avenue, Murray Hill, NJ 07974. The wells
will be located on the property owned by RRPV 601 Midtown Raleigh LP at 621 E. Six Forks Road in Raleigh, NC -Wake
County. This Permit is issued in accordance with the application received on May 5, 2022, in conformity with
specifications and supporting data, all of which are filed with the Department of Environment and Natural Resources and
are considered integral parts of this Permit.
This Permit is for well construction only, and does not waive any provision or requirement of any other applicable law or
regulation. Construction of any well under this Permit shall be in strict compliance with the North Carolina Well
Construction Regulations and Standards (15A NCAC 02C .0100), and other State and Local Laws and regulations pertaining
to well construction.
If any requirements or limitations specified in this Permit are unacceptable, you have a right to an adjudicatory hearing upon
written request within 30 days of receipt of this Permit. The request must be in the form of a written petition conforming
to Chapter 150B of the North Carolina General Statutes and filed with the Office of Administrative Hearings, 6714 Mail
Service Center, Raleigh, North Carolina 27699-6714. Unless such a demand is made, this Permit is final and binding.
This Permit will be effective for one year from the date of its issuance and shall be subject to other specified conditions,
limitations, or exceptions as follows:
1. Issuance of this Permit does not obligate reimbursement from State trust funds, if these wells are being
installed as part of an investigation for contamination from an underground storage tank or dry cleaner
incident.
2. Issuance of this Permit does not supersede any other agreement, permit, or requirement issued by another
agency.
3. The well(s) shall be located and constructed as shown on the attachments submitted as part of the Permit
application.
4. Each well shall have a Well Contractor Identification Plate in accordance with 15A NCAC 02C .0108(o).
5. Well construction records (GW-1) for each well shall be submitted to the Division of Water Quality's
Information Processing Unit within 30 days of the well completion.
6. When the well is discontinued or abandoned, it shall be abandoned in accordance with 15A NCAC 02C
.0113 and a well abandonment record (GW-30) shall be submitted to the Division of Water Quality's
Information Processing Unit within 30 clays of the well abandonment.
7. If the well penetrates any water -bearing zone that contains contaminated waters, the upper three feet of the
well shall be grouted within one day after the casing is set or the well abandoned.
Permit issued the 10 May 2022
FOR THE NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
Scott Vinson, Regional Supervisor
Division of Water Resources
By Authority of the Environmental Management Commission
Permit No. WM0501482
d�yr�+.er y� �IY+i1n�4�F�
North Carolina Department of Environmental Quality 1 Division of Water Resources
512 North Salisbury Street 11611 Mail Service [:enter 1 Raleigh, North Carolina 27699-1611
919 707 9000
NORTH CAROUNA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISIO F WATER RESOURCES
APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM
1.
2.
3.
4.
r rr . --1 DNS .rrrNO► u
PLEASE TYPE OR PRINT CLEARL
In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto,
application is hereby made for a permit to construct monitoring or recovery wells.
ate: April 19.2022
County: Wake County
FOR OFRCE USE ONLY
PERMIT NO. L,Vil050/182 ISSUED DATE
What type of well are you applying for? (monitoring or recovery): Monitoring
Applicant: Gary Fisher. Nokia of America Corporation
Telephone: (908) 358-7475
Applicant's Mailing Address: 600 Mourjaln Avenue. Murray Hill. New Jersey 07974
Applicant's Email Address (if available): garv.fisheretnoktacom
5. Contact Person (if different than Applicant): Bonani Langan. Wood E&IS Telephone: (919) 564-9999
Contact Person's Mailing Address: 4021 Stirrup Creek Drive. Suite 100. Durham. NC 27703
Contact Person's Emai Address (if available): bonani.Iangan(dtwoodolc.com
RRPV 601 Midtown Raleigh LP
6. Property Owner (if different than Applicant): Pete McCintock. Telephone: 919-336-5313
Property Owner's Mailing Address: 127 W. Worthington Avenue. Suite 290. Charlotte. NC 28203
Property Owner's Emati Address (if available): dklepsearamrealestate.com
7. Property Physical Address (Including PIN Number) 621 E Six Forks Road (PIN 1715133477)
City Raleigh County Wake Zip Code 27609
8. Reason for Well(s): Replacement wells for aroundwater contaminatioNpost remediation monitoring
(ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.)
9. Type of facility or site for which the walks) is(are) needed: Fortner electroplating. RCRA generator
(ex: non -discharge facility, waste disposal site, landfill, UST, etc.)
10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s).
RCRA Permit NCD-003-185-2 R-2
11. Type of contaminants being monitored or recovered: Volatile Organic Compounds
(ex: organics, nutrients, heavy metals, etc.)
12. Are there any existing wells associated with the proposed well(s)? If yes, how many? 19 monitoring
Existing Monitoring or Recovery Well Construction Permit No(s).: WM0501363
13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): approximately 550 feet
14. Are there any water supply wells located less than 500 feet from the proposed wef(s)? No
If yes, give distance(s):
15. Well Contractor: Parratt-Wolff. Inc. Certification No.: 2973
Well Contractor Address: 501 Millstone Dr. Hillsborough. NC 27278
PROPOSED WELL CONSTRUCTION INFORMATION
1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following:
a.
b.
c.
d.
orehole and well diameter
Estimated well depth
Screen intervals
Sand/gravel pack intervals
e.
f.
9.
Type of casing material and thickness
Grout horizons
Well head completion details
Continued on Reverse
PROPOSED WELL CONSTRUCTION INFORMATION ( ontinued)
2. Number of wells to be constructed in unconsolidated 5. How wilt the well(s) be secured? Flush -mount,
material: 1 protective cover. concrete pad. locking well cap
3. Number dwells to be constructed in bedrock: 1
6. Estimated beginning construction date: Mav 1..2022
4. Total Number of wells to be constructed: 2
(add answers from 2 and 3) 7. Estimated construction completion date May 30.2022
1.
ADDITIONAL I FORMATION
As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following:
a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as Identified roads,
intersections, streams, or lakes within 500 feet of the proposed well or well system.
b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system.
c. The proposed well or well system.
d. Any test borings within 500 feet of proposed well or well system.
e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel
storage areas, animal feedlots as defined in G.S. 143-215.10B landfills, or other waste disposal areas) within 500 feet
of the proposed well or well system.
The Applicar4ereby
this Well Cldnt(tru
Signature of Pro jr Own: (if
}Caren D. Geller 1
SIGNATURES
rees tit the proposed well(s) will be constructed in accordance with approved specifications and conditions of
itfaA regulated under the Well Construction Standards ('Celle 15A of the North Carolina Administrative Code,
/5ubchapter2C) and accepts full responsibility for compliance with these rules
Environmental Engineering Manager
Signature of pplcant or Agent Title of Applicant or *Agent
Gary Fisher
Printed name of Applicant or *Agent
'If signing as Agent, attach authorization agreement stating
that you have the authority to act as the Agent.
If the property is owned by someone other than the applicant the property owner hereby consents to allow the applicant to construct
welts as outlined in this Well Construction Permit application and that it shall be the responslb ity of the applicant to ensure that the
well(s) nfonn o Well • nst 'o t andards (Title 15A of the N pnt gdmirlist Ve ode Subcha ter 2C).
�Ps��m F�ea�ljr-Assordatea� LL�. as fufansyerCf
RRPV 601 Midtown Raleigh GP LLC, as General Partner of
Pnn eel name rope caner erent than Applicant)
nt an Applicant)
r S. Stull
DIRECTIONS
Please send the completed application to the appropriate Division of Water Resources' Regional Office:
Asheville Regional Office
2090 U.S. Highway 70
Swannanoa, NC 28778
Phone: (828) 296-
Fax: (828) 299
Fayetteville Regional Office
225 Green Street, Suite 714
Fayetteville, NC 28301-5094
Phone: (910) 433-
Fax: (910) 486
Mooresville Regional Office
610 East Center Avenue
Mooresville, NC 28115
Phone: (704) 663-
Fax: (704) 683
Raleigh Regional Office
3800 Barrett Drive
Raleigh, NC 27609
Phone: (919)791-
Fax: (919) 57
Washington Regional Office
943 Washington Square Mali
Washington, NC 27889
Phone: (252) 948-
Fax: (252) 975-371
Wilmington Regional Office
127 Cardinal Drive Extension
IMImington, NC 28405
Phone: (910) 796-7215
Fax: (910) 350-2004
Winston-Salem Regional Office
450 W. Hanes Mill Road
Suite 300
Winston-Salem, NC 27105
Phone: (336) 776-9800
Fax: (336) 776-9797
ti
GW-22MR Rev. 3-1-2016
J.
fitd
tel
o : 100 200 1
J I . Feet
is
r
Monitoring Wells
• TYPE II Monitoring Welk
it TYPE DI Monitoring Welk
O Monitoring Wai Not Coated
■ Proposed TYPE R Monitoring Wells
* Proposed TYPE RI Monitoring Wells
Approximate Extent of Groundwater Contamination In Bedrock Aquifer (July 2021)
Approximate Extent of Groundwater Contamination In Unconsolidated Aquifer (July 2021
streets
Former Structure
_ ; 500 Foot Buffer
I= Property Boundary
I orrer t. C W ,.eaa}v+r. 5p1�
. Gi+'m8'?ahar rumru'7.0.1.; ; WuC. r19i8maoa,7 .N370Tr
wood.
SITE:
FORMER ALCATEL-LUCENT USA INC. FACILITY
1200 WAKE TOWNE DRIVE
RALEIGH, NORTH CAROLINA 27000
CLIENT:
NOKIA OF AMERICA CORPORATION
MURRAY HILL, NEW JERSEY
TIRE:
PROPOSED WELL LOCATION MAP
SCALE: 1ti170
DATE: 345)2022
PROJECT: B228220050
Figure
1
Wood Environment S Infrastructure Solutions, Inc.
4021 Stirrup Creek Drive. Sine 100
Durham, NC 27703
(919) 3S1-9900
ORAWN BY: A. Bousquel
CHECKED BY: S. Lonna
LOCATION' n... • r nw.aw.nnurwu . am n,.
mnr...rv.....
PROJECT NAME: Former Alcatel -Lucent USA, Inc. Facility WELL NUMBER: MW 9dkr
LOCATION: 621 E Six Forks Road, Raleigh, NC INSTALLATION DATE: May 2022
SUBCONTRACTOR: Parrett Wolff FIELD REP: TBD
PROJECT NO.: 6228220058
Ground
Surface
Concrete Pad
Flush -Mounted
Protective Cover
(8" Bolt -Down)
a
d.
4
1
6" —
Portland Cement Grout
2" Schedule 40 Flush -Threaded
P.V.0 Well Casing
6" Schedule 40
P.V.0 Isolation Casing
Bentonite Chips Seal
I v
vIvl
v vc v4/
v` v c vVIvN
ry v
�V1 vN1v1
v •v
vvd VTv1
v`° 'v v
vN v o vvV 10" Diameter Boring
v``v� V VN
V'V '° V
v`oV o�
vvi
vvc vv v
v`° '° v
v� oa ° ._— Bottom of Isolation Casing
VC V
• bmi
j- Top of Bentonite
Top of Casing
Silica Sand Filter Pack
2" Diameter Schedule 40 0.010"
Slotted P.V.0 Well Screen (Pre -Pack)
v
✓ v N Top of Isolation Casing
v
,v • v7
✓ v
vs
v
o vN
v
✓ v
vI
Top of Sand Filter Pack
Top of Well Screen
8" Diameter Borehole
Flush -Threaded Plug "01- Bottom of Well Screen
Bottom of Boring
[}FPTH
0'
0.5'
50'
51'
55.'
70'
70'
WOO
d4021 Stirrup Creek Drive,
Suite 100
Durham, NC 27703
• (919) 381-9900
PROPOSED MW-9DR
TYPE III MONITORING WELL
CONSTRUCTION DIAGRAM
PROJECT NAME: Former Alcalel-Lucwit USA. Inc. Facility
LOCATION' 621 i= Six Forks Road, Raleigh. NC
SUBCONTRACTOR: Parrett Wolff
WELL NUMBER: MW-9skr
INSTALLATION DATE: PAW
FIELD REP! TBD
PROJECT NO.: 6226220fl66
Ground
Surface
Concrete Pad
6„
Portland Cement Grout
2" Schedu]e 40 Flush -Threaded
P.V.0 Well Casing
BeeksItle Chips Seel
Silks Sand Filter Pads
2" Diameter Schedule 40 0,010"
SIolted P.V.0 Well Screen —
Flush -Threaded Plug
Na1w Scala
Flush-Mou nted
Protective Cover
(8" Solt -Down)
Top of Casing
- Top of Banion lie
DEPTH
fl'
0.5'
6'
— TCp of $end Filter Pack $'
Top of Well Screen 10'
- -Bottom of Well Screen
Bodoni of Wen
Bottom of Boring
BCf7fiE fER
20'
WOO
d4021 Stirrup Creek Drive,
Suite 100
Durham, NC 27703
• (919) 381-9900
PROPOSED MW 9SR
TYPE II MONITORING WELL
CONSTRUCTION DIAGRAM