HomeMy WebLinkAboutNCG030134_2021 DMR_20220412 (2)NCDEQ Division of Energy, Mineral and land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG03 0134
Person Collecting Samples: Abbey Nett
Facility Name: Thermo Fisher Scientific LLC Asheville plant
Laboratory Name: Pace Analytical
Facility County: Buncombe
Laboratory Cert. No.:
Discharge during this period: ❑ Yes
El
No (if no, skip to signature and dote)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances7 ❑ Yes No
If so, which Tier (I, Il, or 111)7
A copy of this DMR has been uploaded electronically via h_ttps:Hedocs.deg.nc.Rov/Forms/SW-DMR Yes ❑ No
Date Uploaded: 4/12/2022
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Code
parameter Outfall t
Outfail 2
Outfall 3
Outfall 4
Outfali
N/A
Receiving Stream Class
TROUT
TROUT
TROUT
TROUT
N/A
Date Sample Collected MM/DD/YYYY
46529
24-Hour Rainfall in inches
C0530
TSS in mg/L (100 or 50•)
0040D
pH in standard units (6.0 — 9.0 FW,
6.8-8.5 SW)
01119
Copper, total recoverable in mg/L
(0.010 FW, 0.0058 SW)
Lead, total recoverable in mg/ L
01051
10.075 FW, 0.22 SW)
01094
zinc, total recoverable In mg/ L (0.126
FW, 0.095 SW)
Chemical Oxygen Demand (COD) In
00340
mg/L (120)
n/a
n/a
n/a
n/a
00552
Non -Polar Oil & Grease in mg/L (15)
' Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SLV (Saltwater)
Notes (optional): i
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the Information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete- I am aware that there are significant penalties for submitting
false information, including the possibility of fines and imprisonment for knowing violations."
Signature of Permitlee or
abbey.nelf@thermofisher.com
Email Address
Authorized Individual
Date
828-658-2882
Phone Number