Loading...
HomeMy WebLinkAboutNCG030134_2022 DMR_20220412 (2)Mtq?-Cq UV2- NCDEQ Division of Energy, Mineral and land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the 5tormwater NPDES Permit Data Monitoring Report (Di1AR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0134 Person Collecting Samples: Abbey Neff Facility Name: Thermo Fisher Scientific LLC Asheville plant Laboratory Name: Pace Analytical Facility County: Buncombe Laboratory Cert. No.: Discharge during this period: ❑ Yes 0 No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑ Yes 0 No If so, which Tier (I, 11, or Ill)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR Yes ❑ No Date Uploaded: 4/12/2022 Analytical Monitoring Requirements for Qutfalls with Industrial Activities — Benchmarks in (Red) Parameter ' Parameter Code Outfall 1 Outfall 2 Outfall 3 Outfall 4 Outfall N/A Receiving Stream Class TROUT TROUT TROUT TROUT N/A Date Sample Collected MM/DD/YYYY 46529 24-Hour Rainfall in inches CO530 TSS in mg/L (100 or 50*) 00400 pH in standard units (6.0-9.0 FW, 6.8-8.5 SW) 01119 Copper, total recoverable in mg/L (0.010 FW, 0.0058 SW) 01051 Lead, total recoverable in mg/ L 0.075 FW, 0.22 SW) 01094 Zinc, total recoverable in mg/ L(0.126 FW, 0.095 5w) Chemical Oxygen Demand (COD) in 00340 mg/L (120) nla n/a n/a n/a 00552 Non -Polar Oil & Grease in mg/L (IS) * Outfalls to outstanding Resource Waters (URW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TS5 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L rw (Freshwater) 5W (saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision In accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false Information, Including the possibility of fines and Imprisonment for knowing violations." Signature of Perm4ee or Dellftated Authorized Individual abbey.neff@thermofisher.com Email Address L[ /)"/�- Date 828-658-2862 Phone Number