HomeMy WebLinkAboutSW6211203_Plansheet SCM-1 - SCM Detail_20220310"STORMWATER MANAGEMENT NOTES:
I. THE DEVELOPER OR HIS AGENT SHALL CONTACT THE DESIGN ENGINEER WHEN THE
BEST MANAGEMENT PRACTICE(S) ARE CONSTRUCTED AND ABOUT TO BECOME
OPERATIONAL SO A FINAL INSPECTION CAN BE PERFORMED TO DETERMINE
COMPLIANCE WITH THE APPROVED PLAN CAN BE PERFORMED.
2. ANNUAL MAINTENANCE INSPECTION AND REPORT REQUIRED - THE OWNER OF A
PERMITTED STRUCTURAL STORMWATER BMP/CONTROL SHALL ANNUALLY SUBMIT A
MAINTENANCE AND INSPECTION REPORT FOR EACH BMP TO THE STORMWATER
ADMINISTRATOR. ANNUAL INSPECTIONS SHALL BEGIN WITHIN ONE YEAR OF THE
RECORDATION OF ANY DEED(S) SHOWING STORMWATER BMPs/CONTROL
STRUCTURES.
3. UPON COMPLETION OF THE PROJECT, AND BEFORE A CERTIFICATE OF OCCUPANCY
SHALL BE GRANTED, THE ENGINEER OF RECORD SHALL CERTIFY THAT THE
COMPLETED PROJECT IS IN ACCORDANCE WITH THE APPROVED STORMWATER
MANAGEMENT PLANS AND DESIGNS.
4. A FINAL INSPECTION OF THE SITE AND STORMWATER MANAGEMENT BMP/CONTROL!
TO BE SCHEDULED WITH AND COMPLETED BY THE PROJECT ENGINEER,
5. NCDEQ AND THEIR ASSIGNS HAVE RIGHT TO ACCESS THE STORMWATER
CONTROL(s) FOR INSPECTIONS OR MAINTENANCE AS NECESSARY.
6. THE ENGINEER'S CERTIFICATION OF COMPLETION WILL BE REQUIRED PRIOR TO THE
FINAL PLAT OR CERTIFICATE OF OCCUPANCY. THE STORMWATER CONTROL IS TO
BE INSPECTED TO ENSURE IT IS FUNCTIONING AS DESIGNED AND HAS FULL
DESIGN VOLUME PRIOR TO ISSUANCE OF THE FINAL CERTIFICATE OF OCCUPANCY.
11, THE PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING THE STORMWATER
CONTROLS(s) ACCORDING TO THE APPROVED MAINTENANCE PLAN AND DIRECTION
OF NCDEQ.
OPERATION & MAINTENANCE PROVISIONS (INFILTRATION)
e .men :
Potential problem:
How to rem. §a e e ro em
he entire infiltration basin
Trash/debris is present
Remove the trash/debris
The grass filter strip or other pretreatment
area
Areas of bare soil and/or erosive gullies
have formed
Regrade the soil if necessary to remove
the gully, plant ground cover and water
until established. Provide lime and a
one-time fertilizer application
Sediment has accumulated to a depth
Search for the source of the sediment and
greater than three inches
remedy the problem if possible. Remove
the sediment and dispose of it in a
location where it will not cause impacts
to streams or the SCM
The flow diversion structure (if applicable)
The structure is clogged
Unclog the conveyance and dispose of any
sediment in a location where it will not
cause impacts to streams or the SCM
The structure is damaged
Make any necessary repairs or replace if
damage is too much for repair
The inlet device
The inlet pipe is clogged (if applicable)
Unclog the pipe and dispose of any
sediment in a location where it will not
cause impacts to streams or the SCM
The inlet pipe is cracked or otherwise
damaged (if applicable)
Repair or replace the pipe
Erosion is occurring in the swale
(if applicable)
Regrade the swale if necessary and
provide erosion control devices such as
reinforced turf matting or rip -rap to avoid
future erosion problems
Stone verge is clogged or covered in
sediment (if applicable)
Remove sediment and clogged stone and
replace with clean stone
The basin
More than four inches of sediment has
Search for the source of the sediment and
accumulated
remedy the problem if possible. Remove
the sediment and dispose of it in a
location where it will not cause impacts
to streams or the SCM
Erosion of the basin surface has occurred
Provide additional erosion protection such
or riprap is displaced
as reinforced turf matting or riprap if
needed to prevent future erosion problems
Water is standing more than three days
after a storm event
Replace the top few inches of soil to see
if this corrects the standing water problem.
If not, consult an appropriate professional
for a more extensive repair
The embankment
Shrubs or trees are growing on the
embankment
Remove trees and shrubs immediately
An annual inspection by an appropriate
professional shows that the embankment
Make needed repairs immediately
needs repair
The outlet device
Clogging has occurred
Clean out the outlet device and dispose of
sediment in a location where it will not
cause impacts to streams or the SCM
The outlet device is damaged
Repair or replace the outlet device
The receiving water
Erosion or other signs of damage have
occurred at the outlet
Repair the damage and improve the flow
dissipation structure
Discharges from the infiltration trench are
causing erosion or sedimentation in the
Contact the local NCDEQ Regional Office
receiving water
OPERATION AND MAINTENANCE
North Carolina storm water rules require quarterly inspections by the regulating agency of infiltration areas as a minimum. More
frequent inspections by the land owner or system operator are strongly encouraged to ensure the proper operation of infiltration
areas.
A. Rainfall Event
1. Inspect the basin after every rainfall event greater than 1.5 inches.
B. Monthly Inspection
1. Inspect the basin monthly
2. Check the infiltration area side slopes; remove trash and repair eroded areas before the next rainfall event.
3. Check the vegetative and rock filters for sediment accumulation, erosion and proper operation of the flow spreader
mechanism and repair as necessary.
C. Quarterly Inspection
1. Inspect the collection system (i.e. catch basin, pipes and grass swales) for proper functioning. Clear accumulated
trash from basin grates and basin bottoms. Check piping for obstructions.
2. Check pond inlet pipes for undercutting, replace rip -rap and repair broken pipes.
3. Reseed grassed swales, including the vegetated filter if applicable, twice a year as necessary. Repair eroded areas
immediately.
D. Six Month Inspection
1. Remove accumulated sediment from the bottom of the outlet structure or other areas where accumulated sediment is
noted.
2. Inspect the embankment taking note of any wet areas where water may be seeping through the soil.
E. General Inspection
1. Maximum grass height is to be bin.
2. No woody vegetation shall be allowed to grow in the infiltration area.
3. Debris shall be removed from blocking the inlet and outlet structures and from areas of potential clogging.
4. Periodic removal of dead vegetation shall be accomplished.
1 5. All components of the infiltration system must be kept in good working order.
RASS SOD NOTE:
RASS SOD SHALL BE EITHER HYBRID BERMUDA GRASS OR CENTIPEDE THAT HAS BEEN GROWN IN A SOIL
iAT IS FREE OF AN IMPERMEABLE LAYER (SUCH AS CLAY).
NOTES:
1. ALL INFILTRATION BASINS SHALL HAVE AN ACCESS EASEMENT CONNECTING TO A DEDICATED PUBLIC RIGHT OF WAY.
2. ALL DRAINAGE AREAS TO AN INFILTRATION BASIN ARE TO BE STABILIZED PRIOR TO INSTALLATION OF SOILS OR GRASS SOD.
3. THE DRAINAGE AREA OF THE INFILTRATION BASIN WILL BE CAREFULLY MANAGED TO REDUCE THE SEDIMENT LOAD TO THE SAND FILTER SYSTEM.
4. THE WATER LEVEL IN THE MONITORING WELL(S) WILL BE RECORDED ONCE A MONTH AND AFTER EVERY STORM EVENT GREATER THAN 1.5 INCHES.
5. IMMEDIATELY AFTER THE INFILTRATION BASIN IS ESTABLISHED, THE VEGETATION WILL BE WATERED TWICE WEEKLY IF NEEDED UNTIL PLANTS BECOME
ESTABLISHED (COMMONLY SIX WEEKS)
6. NO PORTION OF THE INFILTRATION BASIN WILL BE FERTILIZED AFTER THE INITIAL FERTILIZATION THAT IS REQUIRED TO ESTABLISH THE VEGETATION.
7. THE VEGETATION IN AND AROUND THE BASIN WILL BE MAINTAINED AT A HEIGHT OF APPROXIMATELY SIX INCHES.
TOP OF EMBANKMENT = 441.0
100-YEAR STORM ELEVATION = 440.18
SPILLWAY ELEVATION = 439.4
10-YEAR STORM ELEVATION = 439.34
2-YEAR STORM ELEVATION = 438.09
1-YEAR STORM ELEVATION = 437.61
EXISTING GRADE = 437.0
1.0" RAINFALL ELEVATION = 436.18
BOTTOM OF BASIN = 436.0
r ILl LR MIA I URL (FROM TOP)
1'-0" OF CLEAN ASTM C-33 SAND
(MEDIUM AGGREGATE SAND WITH A SIZE
RANGE OF 0.02-INCH TO 0.04-INCH
DIAMETER)
LAYER OF GEOTEXTILE PERMEABLE
FILTER FABRIC (MIRAFI N-SERIES OR
EQUIVALENT)
1'-0" MIN. UNDISTURBED IN -SITU SOIL
SEASONAL HIGH WATER TABLE < 422.0
STORMWATER MANAGEMENT DETAILS
NOT TO SCALE
- 440
1'-0" CLEAN SAND
INFILTRATION BASIN TYPICAL SECTION
NTS
FILTER FABRIC AT BOTTOM
AND SIDES OF CLEAN SAND
RIP -RAP PRE-TREATMENT
FOREBAY AT PIPE INLETS
SEE DETAIL THIS SHEET
GRASS SOD
FILTER FABRIC
L\\\
\> 440
/r-
P.
STORMWATER `Z
MANAGEMENT \
EASEMENT
lot dA
\
TOP OF EMBANKMENT
�� \
\
ELEV=341.0
r
I
o
r
/
GRASS SPILLWAY \ \
\
\
/
REFER TO DETAIL
I
THIS SHEET
I
/
/ I
STORMWATER
1
MANAGEMENT
EASEMENT
I \
I
1
.5
/
X
u \ OBSERVATION WELL \ \
\ (TYP.) \
GRAPHIC SCALE
30 0 15 30
1 INCH = 30 FEET
INFILT
SAND
REMOVABLE CAP
6" SCHEDULE 40 PVC, SDR35, OR SMOOTH WALL
CORRUGATED PLASTIC PIPE WITH 3/8" PERFORATIONS
FLUSH WITH PAVEMENT IN ® 6" ON CENTER (4 HOLES PER ROW)
PFRMFABLF PAVFMFNT ARFAS4,
+iu5 41 nos
;yNi Syw x}T>',s�
0
�(L �a d1{Y'y.y{ yr$'�`•
1 s ; ayr
�y�
•e ,$".' NybpY .,Au.sp dao+
0 O
O
�ppaw®yai^
L•`'. k"M 'q�piyPP` !
atin#wkntiw p�' SP iS':.i!`
r^g YS S '',7.� �A�OtI{kt a�'yM
p p
O
r"AN },vim
R ,' , t. * ,d 4 "�`b'#`u da�q
ex
L�+re`k,ak tRYSk jeg Li§0a,
�a ii' t 7 hP
p p
p
o o
, p
: ei�gN�?ti•p"{��ap}en
p p
RATION
I, a�vtalcem'A
n $ ba nS,e yayhws 4, `# adr
"% 4,•", ;,.4
0
°rMPr§r
O
a°•m 6 A4rk 48� td
V9
W
MEDIAE
•d€r.%tYd
R Ct9 ,� YdR tl k" "p9.{db
0 0
0}"rs
p
,t+ny°Nq�SrPwniri§F{Y"dR
AnA Jfi",
i
,�q5% 4"`Y 0 +°�4 P33Ci tl JPo s'
O O
0
t�
`R
C9•
vy5yy�P�q«,.pr5tl/SSbWI
0 OUJ
p
0
'"'aY''Pi*"i�®f®'',i`T�Y tw'�bRq
'pa
0
r.0
OW9.dwq74,+r�g'
fir1y,M��X,r�,r
}•(' d�ai+ero
Z\{A^a41,r
oa
O
4q C�bd'��°
F#i6"'f�&g
aa+,,k+ '
0 0
0 0 0
,�4 §pia¢s1'% "•, y,
a,E�+°pPk^;54
000°'
o
h� R a« itsgx p.
O o
z= w F Spr
o
INSERT 4"-6" INTO-,-*
IN -SITU SOIL BASE OBSERVATION WELL
SCALE: N.T.S.
STORM DRAINAGE PIPE
OR CONCRETE FLUME
OUTFALL INTO POND LENGTH & WIDTH
DIMENSIONS TO BE
PER RIP -RAP
J �.. APRON DETAIL
SILT FENCE AS NEEDED
UNDISTURBED SUBSOIL
FILTER BED
ELEVATION
r BIO-RETENTION POND
6" CLASS B
RIP -RAP OVER
FILTER FABRIC
/--FILTER MEDIA (SEE NOTE 2)
PUMP
FLOW
NOTE:
1 PRIOR TO INSTALLATION, MANUFACTURER SPECIFICATIONS OF FILTER MEDIA SHALL
BE REVIEWED TO ENSURE THAT DISCHARGE FROM FILTER MEDIA SHALL MEET OR
EXCEED THE PROVISIONS OF THE CLEAN WATER ACT,
2. ENSURE THAT PUMP PRESSURE DOES NOT EXCEED FILTER MEDIA PRESSURE RATING.
3. FILTER MEDIA MAY BE, BUT NOT LIMITED TO, SAND MEDIA FILTRATION DEVICES,
RATED FILTER FABRIC BAGS OR POLYMER BASED DEWATERING PRACTICES,
4. PUMP STRAINER SHALL NOT BE IN CONTACT WITH BOTTOM OF POND.
INFILTRATION BASIN DEWATERING
LOW POINT
TER LEVEL
FLOW LONG. TOP OF EMBANKMENT
SPILLWAY 0000) SLOPE(%) H B W SS CHANNEL LINING FI FVATION SPILLWAY ELEVATION
INFILTRATION
18.08 CFS
3.33
1.6'
10'
19.6'
3:1
STRAW WITH NET
441.0
439.4
SPILLWAY
NAG SHOREMAX
CLASS C W/ P300
EXTEND LINING TO W
TEXTEND LINING TO
OP OF SPILLWAY
TOP OF SPILLWAY TOP OF EMBANKMENT=441.0
ss H CHANNEL LINING
SPILLWAY ELEVATION=439.4
MATTING SHALL BE AS
NOTED OR APPROVED EQUAL. B
GRASS SPILLWAY DETAIL
GRASS SOD ON SPILLWAY
AND SIDE SLOPES
-STAGE/STORAGE
TABLE
INFILTRATION
BASIN
STAGE
ELEVATION
CONTOUR
INCREMENTAL
TOTAL
(FT)
(FT)
AREA (SF)
STORAGE (CF)
STORAGE CIF,)
0.0
436.0
5385
0
0
1.0
437.0
6275
5830
5830
1.3
437.3
6560
1925
7755 (WQv)
2.0
438.0
7230
4827
12532
3.0
439.0
8235
7733
20314
4.0
440.0
9300
8768
29082
5.0
441.0
10420
9860
38942
STORMWATER MANAGEMENT DESIGN
INFILTRATION BASIN
RIVER BASIN: LUMBER
RECEIVING STREAM: MOUNTAIN CREEK
STREAM INDEX: 14-2-16-(2)
STREAM CLASS: C
HUC: 03040203
POND DESIGN SUMMARY
DRAINAGE AREA TO POND:
3.43
ACRES
SITE IMPERVIOUS AREA TO POND:
1.69
ACRES
OFF -SITE DESIGN IMPERVIOUS AREA TO POND:
0.41
ACRES
TOTAL DESIGN IMPERVIOUS AREA TO POND:
2.10
ACRES
PRE -DEVELOPED
POST -DEVELOPED
POST -DEVELOPED
POST -DEVELOPED
POST -DEVELOPED
THROUGH POND
BYPASS
COMBINED
DRAINAGE AREA: 3.43 AC
3.43 AC
1.98 AC
CURVE NUMBER: 77.6
89.5
79.2
INFILTRATION RATE:
9.0 IN/HR
1.0" STORM EVENT:
0.818 CFS
0.000
CFS
1-YEAR STORM EVENT: 8.767 CFS
11.25 CFS
0.000
CFS
3.498 CFS
3.498 CFS
2-YEAR STORM EVENT: 12.52 CFS
14.42 CFS
0.000
CFS
4.927 CFS
4.927 CFS
10-YEAR STORM EVENT: 23.82 CFS
23.05 CFS
0.000
CFS
9.137 CFS
9.137 CFS
100-YEAR STORM EVENT: 42.80 CFS
36.64 CFS
18.08
CFS
16.12 CFS
34.20 CFS
70
1 CD
ca o �
c 0 c0 u,
0 N M E
U Lu Z Lo q Lo
t CC a Co vt
o m 3 rn E 7
Z rn 3LL
CU o _J o
3 n
0
m
*%sono f,,
CAR ��'�.
Off! FESS/p'•,.�
4�O 4,
q!
SEAL
051571
/1 `
C' %'• N� I N 6� •' p0
f
OWNER/DEVELOPER:
Lee Humphrey
Double D Engineering, PLLC
150 S. Page Street
Southern Pines, NC 28387
910-684-8646 (Office)
910-206-1808 (cell)
lee@doubledeng.com
C
0
z
z
�
C
�
z
Q
�
�
V)
N
Q
>-
w
U
Z
Z
U
=
Q
z
••
U
�
U
rill
Q
W
W
W
0
z
UJ
a
0
N
W
N
O
M
Drawn
Checked
Approved
Project No: 048020
Date: November 2, 2021
Title
STORMWATER
CONTROL
MEASURE DETAILS
Sheet No.
�cm