HomeMy WebLinkAboutSW6211203_Add Info_20220209ROY COOPER Governor ELIZABETH S. BISER Secretary BRIAN WRENN Director Carlo Pardo, PE 4004 Barrett Drive, Suite 101 Raleigh, NC 27609 AND NORTH CAROLINA Environmental Quality February 9, 2022 211 Shopping Center, LLC Attn: Mubarak Shahbain — Managing Member 1184 Fayetteville Road Raeford, NC 28376 Subject: Request for Additional Information Stormwater Permit No. SW6211203 McCain Gas Station Hoke County Dear Mr. Pardo and Mr. Shahbain: The Division of Energy, Mineral and Land Resources (DEMLR), received a Stormwater Management Permit Application for the subject project on December 16, 2021. A review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Section IX of the Application — Since the Applicant is also the Property Owner, the Property Owner Authorization is not required and should not be signed. With your permission, I will cross -out this signature on the form. If that is not acceptable, please provide a revised signature page for the Application. 2. General MDC 4 — Please provide calculations showing that the inlet to the SCM has been adequately designed to protect the SCM from erosion. It is noted that the 10-year design storm does not result in a discharge from the SCM so outlet calculations are not required. 3. General MDC 9 — Please increase the size of the SCM access/maintenance easement to include the entire SCM system. Per the provided plans, the emergency spillway appears to be partly located outside of the easement. Per the Manual, the entire footprint of the SCM system (The SCM system includes the side slopes, forebay, riser structure, SCM device, basin outlet, dam embankment, outlet, and emergency spillway) must be included North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 NORTH CAROLINA _ oepm nt of EnvimnmwUl uwl ry 919.707.9200 in the access and maintenance easement. You may wish to extend the easement an additional 10 feet around the SCM system to provide sufficient room to complete maintenance tasks. 4. Supplement-EZ Form, Infiltration System Page: a. Line 22 —Per the provided soils report (9/21/2021), the soil conditions were only evaluated to elevation 422. Please either revise this item to "< 422" or provide a soil report verifying that the SHWT is lower than elevation 415 (as shown on the form). b. Line 24 — Per the provided soils report, the SHWT was not observed within 15 feet of the ground surface elevation. Per the prior comment, the soil conditions were only evaluated to elevation 422 so the ground surface elevation can be determined to be at elevation 437 (422 + 15). Please either revise this item to "437" or provide a soil report verifying that the ground surface elevation is at elevation 440 (as shown on the form). c. Line 26 — Per the provided soils report, the soil infiltration rate at the proposed bottom elevation of the infiltration basin is 18 in/hr (10 in/hr if using the more conservative infiltration rate at a slightly lower elevation). Please either revise this item to coincide with the soils report or provide a soil report verifying that the infiltration rate is 9 in/hr (as shown on the form). If the infiltration rate was intentionally lowered (to account for clogging of the soils that will happen over time) you can make a note of it in the "Additional Information" section (Line 46) and use the lowered infiltration rate for this item. d. Line 30 — The storage elevation for the infiltration basin is the elevation that the design volume (7,481 cf) would pond to. Per the provided stage -storage table, the design volume would pond to an elevation of approximately 437.25 (The provided storage volume at elevation 437 is only 5,830 cf). Please revise as needed. e. Line 33 — Similar to the prior comment, the surface area for the storage elevation should be evaluated at the elevation that the design volume would pond to. Per the provided stage -storage table, the design volume would have a surface area of approximately 6,500 sf. Please revise as needed. f. Line 45 — Please calculate the actual drawdown time of the design volume (72 hours is the maximum allowable per the MDC, but the actual drawdown time of this infiltration basin would be much faster. Equation 2 in Part C-1 of the Manual can be re -arranged as follows to calculate the actual drawdown time based on the actual design parameters: T = FS * (DV * 12) / (K * SA) 5. Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, 1 hardcopy of other documents, and a response to comments letter briefly describing how the comments have been addressed. a. Pdfs must be uploaded using the form at: https:,[/edocs.deq.nc.gov/Forms/SW-Supplemental-Upload b. Hard copies must be mailed or delivered to the following address: i. For FedEx/UPS: Jim Farkas 512 N. Salisbury Street, Office 640E Raleigh, NC 27604 ii. For USPS: Jim Farkas 1612 Mail Service Center Raleigh, NC 27699-1612 iii. Hand Delivery: Please reach out to me prior to hand delivering a submission to make sure that I (or someone else in my group) will be able to receive the submission. Do not leave the package in the foyer with the security guard. NOTE: Hard copies should not be sent to a Regional Office. Doing so will delay the review process and the submission package may be lost while being sent from the Regional Office to me in the Central Office. While it is not required, it is recommended that the off -site drainage from upstream properties be diverted around the SCM since the Applicant cannot maintain control over the development of property that they do not own. If the Applicant elects to account for off -site drainage, it must be accounted for at its full build out potential (per 15A NCAC 02H .1003(3)(b)) which can either be assumed to be 100% BUA or can be handled by having a recorded legal agreement in place between the Applicant and the Owner of the upstream property in which the Owner of the upstream property agrees to record a deed restriction limiting the minimum/maximum amount of BUA on the upstream property that will be treated in the Applicant's SCM, the locations and sizes of access and drainage easements, how construction and/or ongoing maintenance costs will be handled, maintenance responsibility, a list of legal recourses available to each party should one party fail to hold up their end of the agreement, and any other related legal issues. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to March 11, 2022, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. Please reference the State assigned project number SW6211203 on all correspondence. If you need additional time to submit the information, please submit your request for a time extension to the Division at the contact below. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. If you have any questions concerning this matter please feel free to contact me at Jim.Farkas@ncdenr.gov or (919) 707-3646. Sincerely, V✓vl Jim Farkas Environmental Engineer Stormwater Program cc: Fayetteville Regional Office