Loading...
HomeMy WebLinkAboutNC0020354_Authorization to Construct_20090603 (2)NPDES DOCIMENT !;CANNING COVER SHEET NPDES Permit: NC0020354 Pittsboro WWTP Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) j;` Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Technical Correction Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: June 3, 2009 This document is printed on reuse paper - ignore any content on the resrerse side ern NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Govemor Director Secretary June 3, 2009 Mr. William Terry, Town Manager Town of Pittsboro Post Office Box 759 Pittsboro, North Carolina 27312 SUBJECT: Authorization to Construct A to C No. 020354A02 Town of Pittsboro WWTP Wet Weather Flow Improvements Chatham County Dear Mr. Terry: A letter of request for an Authorization to Construct was received on May 14, 2009, by the Division of Water Quality (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 0.75 MGD Wastewater Treatment Plant, with discharge of treated wastewater into the Roberson Creek in the Cape Fear River Basin. Please note that if the Town of Pittsboro applies, or has applied, for funding through the American Recovery and Reinvestment Act (ARRA) of 2009 and receives a successful priority rating score, an engineering report must also be submitted for our review and approval. Based on our review, the approved engineering report may limit ARRA funding eligibility to a particular size for the proposed flow equalization basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Installation of a 675,000 gallon flow equalization basin with two (2) compartments each with a 7.5 Hp floating surface aerator; a flow equalization basin pump station with two (2) 1,110 GPM pumps and a magnetic flow meter; a return activated sludge (RAS) pump station consisting of three (3) 300 GPM pumps with VFDs; a UV disinfection system with two (2) banks each rated to treat a peak flow of 1.875 MGD; replacement of a VFD and PLC at the influent pump station; and a standby diesel generator with automatic transfer switch, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-64921 Customer Service:1-877-623-6748 Internet www.ncwaterquality.org An Equal opportunity 1 Affirmative Action Employer None hCarolina 7V'aturallij Mr. William Terry, Town Manager June 3, 2009 Page 2 This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0020354 issued December 15, 2006, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0020354. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Construction Grants & Loans, DWQ/DENR, 1633 Mail Service Center, Raleigh, NC 27699-1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. Mr. William Terry, Town Manager June 3, 2009 Page 3 You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you in a separate transmittal. If you have any questions or need additional information, please contact Seth Robertson, P.E. at telephone number (919) 715-6206. Sincerely, Coleen H. Sullins st:sr cc: John Eick, P.E. — Stearns & Wheler, PLLC, 3128 Highwood Blvd, Suite 140, Raleigh, North Carolina 27604 Chatham County Health Department DWQ Raleigh Regional Office, Surface Water Protection Technical Assistance and Certification Unit Point Source Branch, NPDES Program Steve Tsadwa, E.I. ATC File