HomeMy WebLinkAboutWI0501074_Injection Event Record_20220324North Carolina Department of Environmental Quality — Division of Water Resources INJECTION EVENT RECORD (IER) Permit Number WI0501074 1. 2. 3. Permit Information Schlage Lock Company LLC Permittee Former Schlage Lock Plant Facility Name 213 Red Iron Rd., Rocky Mount, NC, 27804, Nash County Facility Address (include County) Injection Contractor Information Michael Gerber/ Cascade Injection Contractor / Company Name Street Address: 3020 Avondale Mill Rd. Macon GA 31216 City State Zip Code L951)743-5497 Area code — Phone number Well Information Number of wells used for injection 102 DPT Temporary Injection Points — No well casing installed Well IDs: See Table 1 Were any new wells installed during this injection event? a Yes ❑ No If yes, please provide the following information: Number of Monitoring Wells 0 Number of Injection Wells 102 DPT Temporary Injection Points — No well casing installed Type of Well Installed (Check applicable type): ❑ Bored ❑ Drilled /1 Direct -Push ❑ Hand -Augured ❑ Other (specify) 4. 5. Please include a copy of the GW-1 form for each well installed Were any wells abandoned during this injection event? A/ Yes ❑ No If yes, please provide the following information: Number of Monitoring Wells 0 Number of Injection Wells 102 DPT Temporary Injection Points — No well casing installed Please include a copy of the GW-30 for each well abandoned. Injectant Information ABC, ABC+, KB-1 Plus, Magnesium Hydroxide, Sodium Bicarbonate, Sodium Sulfite, KB-1 Primer. Amounts summarized in Table 2 Injectant(s) Type (can use separate additional sheets if necessary Concentration Products received and batched to final concentrations described in Table 3 If the injectant is diluted please indicate the source dilution fluid Potable Water — City of Rocky Mount Total Volume Injected (gal) 307,382 Volume Injected per well (gal) See Table 1 Injection History Injection date(s)1/12/20221 to 2/26/2022 Injection number (e.g. 3 of 5) 1 (No follow up injections planned at this time: post injection monitoring results will be used to determine if future injections are required) Is this the last injection at this site? a Yes ❑ No Submit the original of this form to the Division of Water Resources within 30 days of injection. Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-807-6464 Form UIC-IER Rev. 3-1-2016 I DO HEREBY CERTIFY THAT ALL THE INFORMATION ON THIS FORM IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE INJECTION WAS PERFORMED WITHIN THE STANDARDS LAID OUT IN THE PERMIT. 3/21/2022 SIGNATURE OF INJECTION CONTRACTOR DATE Michael Gerber PRINT NAME OF PERSON PERFORMING THE INJECTION Submit the original of this form to the Division of Water Resources within 30 days of injection. Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-807-6464 Form UIC-IER Rev. 3-1-2016 Table 1 - Well IDs and Volumes Former Schlage Lock Company Rocky Mount, North Carolina CHA8509 Geosyntec Consultants ABC _ Aquifer Injection Area Well ID (DPT Injection Location) Minimum Total Volume Injected per DPT Injection Location (gals) Maximum Total Volume Injected per DPT Injection Location (gals) Middle HC1 HC1-01, HC1-02, HC1-03, HC1-04, HC1-05, HC1-06 2,338 5,108 HC2 HC2-12, HC2-14, HC2-15, HC2-16, HC2-17, HC2-18, HC2-19, HC2-20, HC2-21, HC2-22, HC2-23, HC2-25, HC2-30 2,359 3,696 HC3 HC3-05, HC3-06, HC3-07, HC3-08 HC3-09, HC3-10, HC3-11, HC3-12, HC3-13, HC3-14, HC3-15 2,305 3,227 DG1 DG1-01, DG1-02, DG1-03, DG1-04, DG1-05, DG1-06, DG1-07, DG1-08, DG1-09, DG1-10, DG1-11, DG1-12, DG1-13, DG1-14 1,696 3,150 Lower HCl HC1-01, HC1-02, HC1-03, HC1-04, HC1-05, HC1-06 2,305 2,766 HC2 HC2-03, HC2-04, HC2-05, HC2-06, HC2-11 1,296 3,948 HC3 HC3-01, HC3-02, HC3-08 HC3-09, HC3-10 3,688 3,688 HC4 HC4-01, HC4-02, HC4-03 3,786 4,205 DG1 DG1-06, DG1-07, DG1-08, DG1-09 4,200 4,244 DG2 DG2-01, DG2-02, DG2-03, DG2-04 2,613 2,615 DG3 DG3-01, DG3-02, DG3-03, DG3-04, DG3-05, DG3-06, DG3-07, DG3-08, DG3-09, DG3-10, DG3-11, DG3-12 2,610 3,152 ABC+ Aquifer Injection Area Well ID (DPT Injection Location) Minimum Total Volume Maximum Total Volume Injected per DPT Injection Location (gals) Injected per DPT Injection Location (gals) Middle HC2 HC2-01, HC2-02, HC2-03, HC2-04, HC2-05, HC2-06, HC2-07, HC2-08, HC2-09, HC2-10, HC2-11 2,384 3,136 HC3 HC3-01, HC3-02, HC3-03, HC3-04 1,490 2,060 Lower HC3 HC3-03, HC3-04, HC3-07 2,376 3,144 Notes: 1. gals indicates gallons. 2. DPT indicates direct push technology. 3. DG indicates downgradient injection areas. 4. HC indicates high concentration injection areas 5. Total volume is the summation of the volume of diluted carbon amendment and chase water injected at each injection location. 1 of 1 Table 2 - Materials Injected Former Schlage Lock Company Rocky Mount, North Carolina CHA8509 Geosyntec Consultants Material Injected Amount Unit ABC 94,054 lb ABC+ (ABC and ZVI) 43,460 lb Sodium Bicarbonate 46,950 lb Magnesium hydroxide 4,500 lb Sodium Sulfite 214 lb KB-1 Primer 856 lb KB-1 Plus 46.2 L Notes: 1. lb indicates US pounds. 2. L indicates liters. 3. ABC+ is a 1 to 1 (by weight) mixture of ABC and zero-valent iron (ZVI). 1 of 1 Table 3 - Summary of Injectant Concentrations Former Schlage Lock Company Rocky Mount, North Carolina CHA8509 Geosyntec Consultants Material: ABC Injection Solution Area Aquifer Concentration of ABC (lb/gal) Comment ABC 1:20 HC and DG Middle and Lower 0.41 ABC was diluted with potable water to the concentrations shown. ABC+ 1:10 HC Middle and Lower 0.82 ABC+ 1:15 HC Middle and Lower 0.55 Anaerobic Chase Water No ABC Added to Anaerobic Chase Water Material: Zero Valent Iron (ZVI) Injection Solution Area Aquifer Concentration of ZVI (lb/gal) Comment ABC 1:20 No ZVI Added to ABC 1:20 Injection Solution ABC+ 1:10 HC Middle and Lower 0.82 Concentration reduced partway through injections ABC+ 1:15 HC Middle and Lower 0.55 Anaerobic Chase Water No ZVI Added to Anaerobic Chase Water Material: Magnesium Hydroxide Injection Solution Area Aquifer Concentration of Magnesium Hydroxide (lb/gal) Comment ABC 1:20 No Magznesium Hydroxide Added to ABC 1:20 Injection Solution ABC+ 1:15 HC Middle 0.131 Lower 0.021 ABC+ 1:10 HC Middle 0.196 Lower 0.032 Anaerobic Chase Water No Magnesium Hydroxide Added to Anaerobic Chase Water Material. Sodium Bicarbonate Injection Solution Area Aquifer Concentration of Sodium Bicarbonate (lb/gal) Comment ABC 1:20 HC Middle 0.274 Lower 0.082 DG Middle 0.572 Lower 0.073 ABC+ 1:10 No Sodium Bicarbonate Added to ABC+ 1:10 Injection Solution. ABC+ 1:15 No Sodium Bicarbonate Added to ABC+ 1:15 Injection Solution. Anaerobic Chase Water No Sodium Bicarbonate Added to Anaerobic Chase Water Material: Sodium Sulfite Injection Solution Area Aquifer Concentration of Sodium Sulfite (lb/gal) Comment ABC 1:20 HC and DG Middle and Lower 0.0012 to 0.0005 Concentration reduced partway through injections ABC+ 1:10 HC and DG Middle and Lower 0.0012 to 0.0005 ABC+ 1:15 HC and DG Middle and Lower 0.0012 to 0.0005 Anaerobic Chase Water No Sodium Sulfite Added to Anaerobic Chase Water _ Material: KB-1 Primer Injection Solution Area Aquifer Concentration of KB-1 Primer (lb/gal) ABC 1:20 HC and DG Middle and Lower 0.00175 ABC+ 1:10 HC and DG Middle and Lower 0.00175 ABC+ 1:15 HC and DG Middle and Lower 0.00175 Anaerobic Chase Water HC and DG Middle and Lower 0.007 Material: KB-1 Plus Injected Directly - No Dilution of KB-1 Plus Notes: 1. Four injection solutions were batched and injected. These included a diluted ABC solution, two diluted ABC+ solutions, and anaerobic chase water. 2. 1:10, 1:15, and 1:20 indicate the mixing ration of ABC to potable water that was used to batch the diluted ABC solutions used during injections. 3. lb/gal indicates pound per gallon. 4. DG indicates downgradient injection areas. 5. HC indicates high concentration injection areas 1 of 1