Loading...
HomeMy WebLinkAboutNC0026441_Increased Monitoring_20220512DocuSign Envelope ID: 794E35A0-7630-46FB-98CA-57B2B6805F6C ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. NORTH CAROLINA Director Environmental Quality 5/12/2022 Bill Zell, Interim Town Manager Town of Siler City PO Box 769 Siler City, NC 27344 Subject: Increased Monitoring Siler City WWTP NPDES Permit NC0026441 Grade IV Biological WPCS Chatham County Dear Mr. Zell: As a result of the continuing nature of the Town of Siler City's wastewater treatment plant non-compliance, the Division of Water Resources is requiring that the Town begin increased wastewater treatment plant monitoring [15A NCAC 02B .0508 (b)(2) and G.S. 143-215.66]. Effective upon receipt of this letter, the Town of Siler City shall monitor at a minimum frequency of Daily for the following parameters from the wastewater treatment plant effluent discharge: BOD5, TSS, and Fecal Coliform. Additionally, monitoring for Chronic WET testing shall be increased to Monthly and will be performed as a multiple -concentration toxicity test, as described in "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised- December 2010) or subsequent versions. The Town shall also monitor for Total Iron, Ammonia Nitrogen, NO2-N + NO3-N, and TKN at the influent to the wastewater treatment plant at the frequencies stated in Table 2. These samples shall be analyzed and the results of the analyses reported at the end of each month on the facility's Discharge Monitoring Report form. In addition, the Town of Siler City is required to increase monitoring in the pretreatment permit for Industrial User Mountaire Farms Inc. (IUP 004). The following parameters shall be monitored at a minimum frequency of Daily: BOD, TSS, Ammonia Nitrogen, Total Nitrogen and Total Phosphorous. A summary of the requirements for all increased and additional monitoring are detailed in Tables 1-3 on page three of this letter. This supplemental self -monitoring shall begin immediately and shall continue until the DWR notifies the Town in writing that the increased monitoring is no longer required. The monitoring requirements listed in this notification exist as a supplement to the monitoring required in the Town's NPDES permit (NC0026441), and does not remove any requirements stated in the NPDES permit. The condition of the wastewater treatment plant for the Town of Siler City is a serious concern to the Division of Water Resources and steps must be taken immediately to return the facility to compliance with the NPDES permit and prevent ongoing water quality standards violations that are occurring downstream of the discharge. LD_E NORTH CAROLINA Mryrh,lent of Fnh,onnianbl 9ual North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.9000 DocuSign Envelope ID: 794E35A0-7630-46FB-98CA-57B2B6805F6C Increased Monitoring Siler City WWTP — NC0026441 Page 2 of 3 If you have any questions regarding this matter, please contact the Water Quality Regional Operations staff of our Raleigh Regional Office at (919) 791-4200. You can also contact Sydney Carpenter of the Compliance & Expedited Permitting Unit at (919) 707-3712 or via e-mail at sydney.carpenter@ncdenr.gov. Sincerely, �DocuSigned by: (/ 8328B44CE9EB4A1... Richard E. Rogers Jr., Director Division of Water Resources ec: NPDES Permit Files [Laserfiche] Municipal Permitting Unit Aquatic Toxicity Branch Raleigh Regional Office Jenifer Johnson, Town of Siler City Chris McCorquodale, Town of Siler City Brittany York, Town of Siler City Blakely Hildebrand, SELC Jean Zuang, SELC DocuSign Envelope ID: 794E35A0-7630-46FB-98CA-57B2B6805F6C Increased Monitoring Siler City WWTP — NC0026441 Page 3 of 3 Table 1. Effluent Monitoring Requirements — Siler City WWTP PARAMETER [eDMR Code] MONITORING REQUIREMENTS Measurement Frequency Sample Type Sample Location BOD, 5-day, 20°C (mg/I) [C0310] Daily Composite Effluent Total Suspended Solids (TSS) (mg/L) [C0530] Daily Composite Effluent Fecal Coliform (geometric mean) [31616] Daily Grab Effluent Chronic Toxicity [THP3B] Monthly Composite Effluent Table 2. Influent Monitoring Requirements — Siler City WWTP PARAMETER [eDMR Code] MONITORING REQUIREMENTS Measurement Frequency Sample Type Sample Location Total Iron (as Fe) (ug/L) [01045] Daily Composite Influent Ammonia (NH3 as N) (mg/L) [C0610] Weekly Composite Influent NO2-N + NO3-N (mg/L) [00630] Weekly Composite Influent TKN (mg/L) [00625] Weekly Composite Influent Table 3. Pretreatment Monitoring Requirements — Mountaire Farms Inc. PARAMETER MONITORING REQUIREMENTS Measurement Frequency Sample Type Sample Location BOD (mg/I) Daily Composite Effluent Total Suspended Solids (TSS) (mg/L) Daily Composite Effluent Ammonia (NH3 as N) (mg/L) Daily Composite Effluent Total Phosphorous (TP) (mg/L) Daily Composite Effluent Total Nitrogen (TN) (mg/L) Daily Composite Effluent