Loading...
HomeMy WebLinkAboutWQ0000962_NOD-2022-PC-0072_20220511ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Mark Creech, Plant Manager Culp, Inc. P.O. Box 488 Stokesdale, NC 27357 NORTH CAROLINA Environmental Quality May 11, 2022 SUBJECT: Notice of Deficiency (NOD-2022-PC-0072) Compliance Evaluation Inspection Culp, Inc. Closed Loop Recycle Wastewater Permit No. WQ0000962 Guilford County Dear Mr. Creech: On May 6, 2022, Division of Water Resources staff Caitlin Caudle conducted a routine compliance inspection. A review of records, treatment facility, and monitoring wells were conducted. Mark Creech, Derr Leonhardt, Tyler Miles, and Chad Cusin were present during the review of records, facility, and monitoring wells. Chris Miles and Barry Bryant were also present during the review of the facility and the monitoring wells. This review reflected non-compliance with the subject permit. The following deficiency was noted: 1. Effective December 1, 2021, effluent sampling increased from yearly in November to three times a year in March, July, and November, as listed in Attachment A. Sampling of effluent was not completed in March 2022. This is a violation of the subject permit. Moving forward please ensure that all sampling is conducted at the required frequency. The following item of concern was noted: A. Per Permit Condition 111.7 "a protective vegetative cover shall be established and maintained on all berms, pipe runs, erosion control areas, surface water diversions, and earth embankments...." At the time of inspection, little living vegetation was present on the earthen berm surrounding the concreate containment structure. Please continue to make efforts to establish a vegetative cover on this earthen berm. GDE NORTH CAROLINA ' omm mr� ep..of o�.i North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 Please review the enclosed inspection report for additional comments and observations. If you have any questions regarding this letter, please contact me or Caitlin Caudle at the letterhead address or phone number, or by email at lon.snider@ncdenr.gov or caitlin.caudle@ncdenr.gov. Sincerely, DocuSiiggned by:G t- . l . cJn 1c..,- "- 145B49E225C94EA... Lon T. Snider, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ-WSRO Enc: Inspection Report Cc: Leondhardt Environmental (electronic copy) Guilford County Environmental Health (electronic copy) Laserfiche File WQ0000962 WSRO Electronic Files D_E NORTH CAROLINA gaparMeM of Environment,/quay North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 W. Hanes Mill Rd, Suite 300 I Raleigh, North Carolina 27105 336.776.9800 Compliance Inspection Report Permit: WQ0000962 Effective: 12/01/21 Expiration: 04/30/28 Owner : Culp, Inc SOC: Effective: Expiration: Facility: Culp Ticking CLRS County: Guilford 7209 US 158 E Region: Winston-Salem Contact Person: Teresa Huffman Stokesdale NC 27357 Title: Vice President Phone: 336-888-6266 Directions to Facility: From downtown Winston-Salem, take NC 158 East approximately 22 miles to Stokedale. Continue on NC 158 for approximately 2 more miles. Facility is on the right at address #7209. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 05/06/2022 Primary Inspector: Caitlin Caudle Secondary Inspector(s): Entry Time 10:OOAM Exit Time: 10:51AM Phone: 336-776-9699 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Closed -Loop Recycle Facility Status: ❑ Compliant II Not Compliant Question Areas: ▪ Miscellaneous Questions Record Keeping Storage ▪ Wells (See attachment summary) Page 1 of 4 Permit: WQ0000962 Owner - Facility: Culp, Inc Inspection Date: 05/06/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On May 6, 2022, Division of Water Resources staff Caitlin Caudle conducted a routine compliance inspection. A review of records, treatment facility, and monitoring well were conducted. Mark Creech, Derr Leonhardt, Tyler Miles, and Chad Cusin were present during the review of records, facility, and monitoring wells. Chris Miles and Barry Bryant were also present during the review of the facility and the monitoring wells. This review reflected non-compliance with the subject permit. The following deficiency was noted: 1. Effective December 1, 2021, effluent sampling increased from yearly in November to three times a year in March, July, and November, as listed in Attachment A. Sampling of effluent was not completed in March 2022. This is a violation of the subject permit. Moving forward please ensure that all sampling is conducted at the required frequency. The following item of concern was noted: A. Per Permit Condition 111.7 "a protective vegetative cover shall be established and maintained on all berms, pipe runs, erosion control areas, surface water diversions, and earth embankments...." At the time of inspection, little living vegetation was present on the earthen berm surrounding the concreate containment structure. Please continue to make efforts to establish a vegetative cover on this earthen berm. Other observations: • Stormwater is now being pumped form the earthen berm to inside the concrete containment area so any effluent captured in the earthen berm can be retreated. The earthen berm is serving as a secondary containment area. • Ms. Caudle requested that at least the emergency contact information from the spill plan be posted in the treatment building. A central point of contact handles any spills. • A lock was present on the valve to release stormwater from the earthen berm. • Rip rap was present under the stormwater release valve. • Locks were present on all monitoring wells. All monitoring wells were in good condition. • Shamrock still hauls residuals captured from the dewatering roll off box and wastewater from the reverse osmosis waste tank. The 8,000 gallon "clean water tank" hold wastewater from the reverse osmosis process. • Shamrock hauls residuals once every three weeks. • The 3,650 gallon pump tank with high-water alarms and two Gorman -Rupp trash pumps with float level switch for large solids removal is no longer present. • Maintenance records are maintained as Preventative Maintenance logs that are completed monthly. • Inspection logs are completed daily. Page 2 of 4 Permit: WQ0000962 Owner - Facility: Culp, Inc Inspection Date: 05/06/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Reuse (Quality) Infiltration System Lagoon Spray, LR Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Activated Sludge Drip, LR Single Family Drip Recycle/Reuse Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? Yes No NA NE • Yes No NA NE ▪ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ▪ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Page 3 of 4 Permit: WQ0000962 Owner - Facility: Culp, Inc Inspection Date: 05/06/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine No treatment units bypassed since last inspection? Comment: MW violations are present but all wells are within compliance boundaries. • ❑ ❑ ❑ Page 4 of 4