HomeMy WebLinkAboutWQCSD0083_Compliance Evaluation Inspection_20220512DocuSign Envelope ID: A01EE1F2-109E-4270-AB03-013DEC5410B8 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director The Honorable John White, Mayor Town of Halifax PO Box 222 Halifax, NC 27839 NORTH CAROLINA Environmental Quality May 12, 2022 Subject: Compliance Evaluation Inspection Town of Halifax Deemed Collection System Collection System Permit Number WQCSD0083 Halifax County Dear Mr. White: On April 13, 2022, Colleen Cohn and Cheng Zhang of the Raleigh Regional Office (RRO) conducted an inspection of the town's wastewater collection system to evaluate compliance with North Carolina Administrative Code Section 15A NCAC 02T .0403 (Permitting by Regulation). The cooperation of Ms. Ester Beal, Mr. Donald Crowder, and Mr. Albert Davis was greatly appreciated. During the inspection, the following items were noted: 1. The Town of Halifax, hereinafter referred to as the Town, operates a deemed collection system pursuant to 15 NCAC .02T .0403. 2. The system includes four (4) duplex pump stations, approximately 26,400 feet of gravity collection line, approximately 7,920 feet of force main, approximately 39,600 feet of force main to the Town of Weldon, and one (1) high priority line. 3. All four (4) pump stations were inspected. All pump stations are connected to a telemetry system. Mr. Davis stated that he inspects the pump stations at least once per week. a. At the Convenience Store Lift Station, minimal grease was observed, and the high-level float, audible alarm, and visual alarm were all operational. A stationary generator is maintained by Gregory Poole. b. At the 903 Lift Station, excessive grease was observed, and water was observed in the dry well. The high-level float and audible alarm were operational, but the visual alarm was not operational. A stationary generator is maintained by Gregory Poole. c. At the Purnell Park Lift Station, minimal grease was observed. The high-level float and audible and visual alarms were operational. A portable generator is on - site. Signs for the facility were overgrown with moss and illegible. Additionally, a power plug on the control panel appeared to have blown a fuse. NORTH CAROLINA E, Department of M Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office I 3800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: A01EE1F2-109E-4270-AB03-013DEC5410B8 Town of Halifax WQCDS0083 May 12, 2022 d. At the Quankey Hills Apartments Lift Station, some grease was observed. The high-level float and audible alarm were operation, but the visual alarm was not operational. There is no generator at this location. e. Within 30-days receipt of this letter, please provide this office with a written response indicating the actions the Town will take or has taken to repair the visual alarms at the 903 Lift Station and Quankey Hills Apartment Lift Station. 4. The high priority line near Purnell Park Lift Station was observed. The right of way was adequately maintained and there were no visible signs of damage. 5. The Convenience Store Lift Station Manhole was inspected. A buildup of rags was observed in the Manhole. Within 30-days receipt of this letter, please provide this office with a written response indicating the actions the actions the Town will take or has taken to minimize the buildup of rags and debris in manholes. Please provide a list of the actions or tasks that are performed during pump station inspections. 6. No Sanitary Sewer Overflows (SSO) have been identified or reported in the last 12 months. 7. Documentation of compliance as required by 15A NCAC 02T .0403(10) were not available during the inspection. The following records were not available: a. Pump stations are required to be inspected at least once per week. Mr. Davis stated that he inspects the pump stations at least once per week. Documentation of these inspections, such as a logbook at each pump station, was not available. b. High -priority sewer shall be inspected once every six -months. Documentation of these inspections was not available. c. A general observation of the entire collection system shall be conducted once per year. As discussed, this is conducted over the course of day-to-day operations, however, documentation of this inspection was not available. d. Right-of-ways and easements appeared to be maintained. No documentation on the frequency of maintenance, such as a mowing schedule, was available. e. An Operation and Maintenance Plan was not available. The plan should include, at a minimum, the pump station inspection frequency, a preventative maintenance schedule, a spare parts inventory, and an overflow response plan. If an Operation and Maintenance Plan has not been developed, then provide this office with a written response outlining the schedule the Town will take to develop an Operation and Maintenance Plan. f. The Town has developed a map of its sewer collection system. The map includes size, location, and flow direction. However, only three of the four pump stations are identified on the map. The 903 Lift Station is not shown on the map. Within 30-days receipt of this letter, please provide this office with a written response indicating the actions the Town will take to update the map to include the 903 Lift Station. g. Documentation of the Town's Grease Control Program was not available. Grease Control Programs should include bi-annual distribution of educational materials for both commercial residential users and the legal means to require grease £ D_E NORTHCAROLINA Department of Environmental Deal North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office I 3800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: A01EE1F2-109E-4270-AB03-013DEC5410B8 Town of Halifax WQCDS0083 May 12, 2022 interceptors for new construction and retrofit and if necessary, of grease interceptors at existing establishments. The plan should also include legal means for inspections of grease interceptors, enforcement for violators, and the legal means to control grease entering the system from other public and private satellite collection systems. Ms. Beal stated that the Town is currently working on creating information packets for new water meters, and the Town plans to distribute Fats, Oils, and Grease (FOG) educational materials with this packet. If materials have been provided within the last 12 months, please provide a copy of those materials and when they were distributed. Please provide the Division with a written response outlining how the Town plans to document compliance with 15A NCAC 02T .0403(10). Within 30-days receipt of this letter, please provide this office with a written response to address Items 3, 5, and 7. If you have questions concerning this report, please contact Colleen Cohn at 919-791-4258 or Colleen.Cohn@ncdenr.gov. Sincerely, pDocuSigned by: Uailn.t,SSa•'. AI -MIA/ B2916E6AB32144F... Vanessa Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachments: Compliance Inspection Report cc: Laserfiche £ D_E NORTHCAROLINA Department of Environmental Deal North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office I 3800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: A01 EE1 F2-109E-4270-AB03-013DEC5410B8 Compliance Inspection Report Permit: WQCSD0083 Effective: 03/01/00 Expiration: SOC: Effective: Expiration: County: Halifax Region: Raleigh Contact Person: Gerald L Wright Directions to Facility: Owner : Town of Halifax Facility: Halifax Collection System Title: Phone: 252-583-6571 System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Ms. Esther Beal Mr. David Crowder Mr. Albert Davis Inspection Date: 04/13/2022 Entry Time 10:OOAM Primary Inspector: Colleen Cohn ,DocuSned by: / Secondary Inspector(s): �FBCB8277092044D... Exit Time: 12:30PM Phone: 919-791-4258 Cheng Zhang ,DocuSigned by: Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling D6171508E1 EC41 F... Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: ▪ Miscellaneous Questions II Spills/Response Plan ▪ Manholes (See attachment summary) ▪ General ▪ Inspections ▪ Pump Stations ▪ Grease Control ▪ Lines Page 1 of 6 DocuSign Envelope ID: A01 EE1 F2-109E-4270-AB03-013DEC5410B8 Permit: WQCSD0083 Owner - Facility:Town of Halifax Inspection Date: 04/13/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: On April 13, 2022, Colleen Cohn and Cheng Zhang of the Raleigh Regional Office (RRO) conducted an inspection of the town's wastewater collection system to evaluate compliance with North Carolina Administrative Code Section 15A NCAC 02T .0403 (Permitting by Regulation). The cooperation of Ms. Ester Beal, Mr. Donald Crowder, and Mr. Albert Davis was greatly appreciated. During the inspection, the following items were noted: 1. The Town of Halifax, hereinafter referred to as the Town, operates a deemed collection system pursuant to 15 NCAC .02T .0403. 2. The system includes four (4) duplex pump stations, approximately 26,400 feet of gravity collection line, approximately 7,920 feet of force main, approximately 39,600 feet of force main to the Town of Weldon, and one (1) high priority line. 3. All four (4) pump stations were inspected. All pump stations are connected to a telemetry system. Mr. Davis stated that he inspects the pump stations at least once per week. a. At the Convenience Store Lift Station, minimal grease was observed, and the high-level float, audible alarm, and visual alarm were all operational. A stationary generator is maintained by Gregory Poole. b. At the 903 Lift Station, excessive grease was observed, and water was observed in the dry well. The high-level float and audible alarm were operational, but the visual alarm was not operational. A stationary generator is maintained by Gregory Poole. c. At the Purnell Park Lift Station, minimal grease was observed. The high-level float and audible and visual alarms were operational. A portable generator is on -site. Signs for the facility were overgrown with moss and illegible. Additionally, a power plug on the control panel appeared to have blown a fuse. d. At the Quankey Hills Apartments Lift Station, some grease was observed. The high-level float and audible alarm were operation, but the visual alarm was not operational. There is no generator at this location. e. Within 30-days receipt of this letter, please provide this office with a written response indicating the actions the Town will take or has taken to repair the visual alarms at the 903 Lift Station and Quankey Hills Apartment Lift Station. 4. The high priority line near Purnell Park Lift Station was observed. The right of way was adequately maintained and there were no visible signs of damage. 5. The Convenience Store Lift Station Manhole was inspected. A buildup of rags was observed in the Manhole. 6. No Sanitary Sewer Overflows (SSO) have been identified or reported in the last 12 months. 7. Documentation of compliance as required by 15A NCAC 02T .0403(10) were not available during the inspection. The following records were not available: a. Pump stations are required to be inspected at least once per week. Mr. Davis stated that he inspects the pump stations at least once per week. Documentation of these inspections, such as a logbook at each pump station, was not available. b. High -priority sewer shall be inspected once every six -months. Documentation of these inspections was not available. c. A general observation of the entire collection system shall be conducted once per year. As discussed, this is conducted over the course of day-to-day operations, however, documentation of this inspection was not available. d. Right-of-ways and easements appeared to be maintained. No documentation on the frequency of maintenance, such as a mowing schedule, was available. e. An Operation and Maintenance Plan was not available. The plan should include, at a minimum, the pump station inspection frequency, a preventative maintenance schedule, a spare parts inventory, and an overflow response plan. f. The Town has developed a map of its sewer collection system. The map includes size, location, and flow direction. However, only three of the four pump stations are identified on the map. The 903 Lift Station is not shown on the map. g. Documentation of the Town's Grease Control Program was not available. Grease Control Programs should include bi-annual distribution of educational materials for both commercial residential users and the legal means to require grease interceptors for new construction and retrofit and if necessary, of grease interceptors at existing establishments. The plan should also include legal means for inspections of grease interceptors, enforcement for violators, and the legal means to control grease entering the system from other public and private satellite collection systems. Ms. Beal stated that the Town is currently working on creating information packets for new water meters, and the Town plans to distribute Fats, Oils, and Grease (FOG) educational materials with this packet. Page 2 of 6 DocuSign Envelope ID: A01 EE1 F2-109E-4270-AB03-013DEC5410B8 Permit: WQCSD0083 Owner - Facility:Town of Halifax Inspection Date: 04/13/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE # Is this system a satellite system? • ❑ ❑ ❑ # If Yes, what is system name or permit number? NC0025721 - Town of Weldon • ❑ ❑ ❑ Is there a overall sewer system map? Does the map include: Pipe sizes Pipe materials (PVC, DIP, etc) Pipe location # Flow direction # Approximate pipe age # Pump station ID, location and capacity # Force main air release valve location & type # Location of satellite connections Are system maintenance records maintained? Comment: 903 Lift Station and associated sewer lines need to be added to the map. Grease Control Is grease/sewer education program documented with req'd customer distribution? # Are other types of education tools used like websites, booths, special meetings, etc? If Yes, what are they? (This can reduce mailing to annual.) For public systems, is there a Grease Control Program via an ordinance/agreement? If Yes, does it require grease control devices at applicable locations? Is the Grease Control Program enforced via periodic inspections/records review? Is action taken against violators? • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ • ❑ Yes No NA NE ▪ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • Comment: Records of Town's Grease Control Program and educational materials were not available. Spills and Response Action Plan # Is system free of known points of bypass? If No, describe type of bypass and location # Have there been any sewer spills in the past 3 years? If Yes, were they reported to the Division if meeting the reportable criteria? If applicable, is there documentation of press releases and public notices issued? Are all spills or sewer related issues/complaints documented? # Are there repeated overflows/problems (2 or more in 12 months) at same location? # If Yes, is there a corrective action plan? Is a Spill Response Action Plan available? Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Page 3 of 6 DocuSign Envelope ID: A01 EE1 F2-109E-4270-AB03-013DEC5410B8 Permit: WQCSD0083 Owner - Facility:Town of Halifax Inspection Date: 04/13/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is a Spill Response Action Plan available for all personnel? Does the plan include: # 24-hour contact numbers ❑ ❑ • ❑ # Response time ❑ El • El # Equipment list and spare parts inventory ❑ ❑ • ❑ # Access to cleaning equipment ❑ ❑ • ❑ # Access to construction crews, contractors, and/or engineers ❑ ❑ • ❑ # Source of emergency funds ❑ ❑ • ❑ # Site sanitation and cleanup materials ❑ ❑ • ❑ # Post-overflow/spill assessment ❑ ❑ • ❑ Comment: A Spill Response Plan needs to be developed as part of the O&M requirements of 15A NCAC 02T .0403(a)(3). ❑ • ❑ ❑ Inspections Yes No NA NE Are adequate maintenance records maintained? ❑ • ❑ ❑ Are pump stations being inspected at the required frequency? • ❑ ❑ ❑ Is at least one complete functionality test conducted weekly per pump station? • ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? • ❑ ❑ ❑ Is the annual inspection documented? ❑ • ❑ ❑ # Does the system have any high -priority lines/locations? • ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? ❑ • ❑ ❑ Are new lines being added to the HPL list when found or created? ❑ ❑ • ❑ Comment: No records of weekly pump station inspections, annual system inspection, or high -priority line inspections were available. Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: High -Priority Line near Purnell Park Lift Station Are right-of-ways and easements maintained for the full width for access? If No, give details on temporary access: Yes No NA NE ❑ ❑ ❑ • Is maintenance documented? ❑ • ❑ ❑ Were all areas/lines inspected free of issues? • ❑ ❑ ❑ Comment: Inspection and maintenance records were unavailable. High -priority line observed from Purnell Park Lift Station. No leaks were observed. Manholes Please list the Manholes Inspected: Covnenience Store Lift Station Manhole Are manholes accessible? # Are manhole covers/vents above grade? Yes No NA NE Page 4 of 6 DocuSign Envelope ID: A01 EE1 F2-109E-4270-AB03-013DEC5410B8 Permit: WQCSD0083 Owner - Facility:Town of Halifax Inspection Date: 04/13/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Are manholes free of visible signs of overflow? Are manholes free of sinkholes and depressions? Are manhole covers present? # Are manholes properly seated? # Are manholes in good condition? # Are inverts in good condition? Is flow unrestricted in manholes? Are manholes free of excessive amounts of grease? Are manholes free of excessive roots? Are manholes free of excessive sand? Are manhole vents screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: Debris and rags noted in manhole. Pump Stations Please list the Pump Stations Inspected: Convenience Store Lift Station, 903 Lift Station, Purnell Park Lift Station, and Quankey Hills Apartments Lift Station # Number of duplex or larger pump stations in system # Number of vacuum stations in system # Number of simplex pump stations in system # Number of simplex pump stations in system serving more than one building How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? # A simple one-way telemetry/communication system (auto -dialer) installed? For pump stations inspected: Are they secure with restricted access? Were they free of by-pass structures/pipes? Were wet wells free of excessive grease/debris? # Do they all have telemetry installed? Is the telemetry system functional? Is a 24-hour notification sign posted ? Does the sign include: Owner Name? Pump station identifier? # Address? Instructions for notification? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE 4 • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 5 of 6 DocuSign Envelope ID: A01 EE1 F2-109E-4270-AB03-013DEC5410B8 Permit: WQCSD0083 Owner - Facility:Town of Halifax Inspection Date: 04/13/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine 24-hour emergency contact numbers? Are audio and visual alarms present? Are audio and visual alarms operable? # Is there a backup generator or bypass pump connected? If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ Comment: No pump station logs were available. Excessive grease was observed at the 903 Lift Station. Visual alarms were not operational at the 903 Lift Station or Quankey Hills Apartments Lift Station. Stationary generators at Convenience Store Lift Station and 903 Lift Station. Portable generator located on -site at the Purnell Park Lift Station. No generator at the Quankey Hills Apartments Lift Station. Page 6 of 6