Person Collecting Samples: J Frei/ SwSG
Facility Name: Flowserve US Inc
Laboratory Name: Pace Analytical/ SwSG
Facility County: Wake
Laboratory Cert. No.: 12, 40, 5054
Discharge during this period:
Yes
Lj
No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes U No
If so, which Tier (I, II, or III)?
A copy of this DMR has been uploaded electronically via https:Hedocs.deg.nc.gov/Forms/SW-DMR Yes No
Date Uploaded: 04/04/2022
Analytical Monitoring Requirements for Outfalls with Industrial Activities - Benchmarks in (Red)
Parameter
Parameter
Outfall ALT
Outfall 001
Outfall 002
Outfall 003
Outfall
Code
N/A
Receiving Stream Class
C; NSW
C; NSW
C; NSW
C; NSW
N/A
Date Sample Collected MM/DD/YYYY
03/24/2022
03/24/2022
03/24/2022
03/24/2022
46529
24-Hour Rainfall in inches
0.78
0.78
0.78
0.78
C0530
TSS in mg/L (100 or 50*)
-
11.5
< 2.6
< 3.0
pH in standard units (6.0 - 9.0 FW,
00400
6.49
6.08
6.87
6.62
6.8-8.5 SW)
Copper, total recoverable in mg/L
01119
(0.010 FW, 0.0058 SW)
0.0096
0.0075
0.0055
0.0077
Lead, total recoverable in mg/ L
01051
0.0073
0.0077
< 0.0050
< 0.0050
(0.075 FW, 0.22 SW)
Zinc, total recoverable in mg/ L (0.126
01094
FW, 0.095 SW)
0.049
0.045
0.036
0.075
Chemical Oxygen Demand (COD) in
00340
mg/L (120)
-
< 25.0
< 25.0
< 25.0
00552
Non -Polar Oil & Grease in mg/L (15)
< 5.0
< 5.0
< 5.0
< 5.1
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SW (Saltwater)
_ Notes (optional): ALT is off -site flow into 001.
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false Information, including the possibility of fines and imprisonment for knowing violations."
of Obr tteior Delegated Authorized Individual
Daigneault, Stephen [SDaigneault@flowserve.com]
Email Address
4/- y - Q. G :)-::L
Date
(985) 688-4270
Phone Number