Loading...
HomeMy WebLinkAboutSW3220302_Plansheet - Other_20220308I' APPROX. LOCATION OFEX. WATER SERVICE LINE(SIZE AND LOCATION TO BE FIELD VERIFIED) SEWER PUMP EX. WATER 1 METER GAS LINE iv i i 484 LF OF 2" PVC WATER SERVICE WATERSHED LINE `C.O. CABLE LINE „—•_— LINE TO NEW BUILDING NOT IN WATERSHED ! sss � °�� TAP INTO EX. SERVICE LINE EX. SEWER SERVICE LATERAL 8' ws AFTER WATER METER 481 LF OF 4" PVC SEWER SERVICE ss _.C.O. \\� I (SIZE TO BE FIELD VERIFIED) \\\�� -- --- -- I @ 1.04%MIN. SLOPE TO NEW BUILDING � � IF SEWER PUMP IS REQUIRED � s - C.O. � � 68.4 I I � 1 — a FOR EX. BUILDING SEWER SERVICE 8. II WS TIE PROP. SEWER SERVICE LINE IN 0 ` — 45° BENDS ws _ s= C O \ AT PUMP II I ss — 30, SETBACK ° I C O I Icl — — — _C.O. I w1 _ C.O. ' — _ I 8 �� n III I 70 n FFE: 847.4, ➢ I < m — — O L BUILDING z c 4° C.O. LOADING DOCKWELL FUTURE MANUFACTURING BUILDING 12,000 SF 4.775 AC +- DB 2990-634 SEE ARCH PLANS FOR TIE IN LOCATIONS FFE: 857.25 UNDERGROUND POWER WATERSHED LINE WS-IV CRITICAL GAS LINE CABLE LINE LAKE NORMAN LUTHERAN CH. _ DB 555-731 EX. 15" HDPE PIPE TION ----- � � - yr c REMAIN) _ _ _ I 17 I I \ I 6 \ I � \ I \ PROPOSED I SCM — EX. 15" RCP PIPE CROWN ATLANTIC CO. \ I DB 1113-540 \ � I � \ I \ I � \ I \ 60' RIGHT OF WAY PER DEED BOOK 787-339 _ (30' EACH SIDE OF BOUNDARY) GENERAL NOTES: 1. ALL PRIVATE SEWER AND WATER TO ABIDE BY NC BUILDING CODE AND LINCOLN COUNTY DEVELOPMENT STANDARDS. T.R.C.O - TRAFFIC RATED CLEANOUT (FLUSH) C.O. - STANDARD CLEANOUT 72.5' ONE STORY COMMERCIA ➢ v, III i � I EX. BUILDING = Z ` p f 17,030 SF ➢ III Q O- �PN 70 `I— — (D NEW ADDITION a d I i 5,203 SF O •vt° d � \\ n \ 1 � I � I \ T � ASPHALT PARKING AREA 46. 15SETBACK 11 THE INVESTMENT CO. DB 2224-807 PB 15-417 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO BEGINNING CONSTRUCTION. 2. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES USING FLAGMEN, ETC., AS NECESSARY TO INSURE SAFETY TO THE PUBLIC. 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO STANDARDS OF THE DEPARTMENT OF TRANSPORTATION. 4. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART P, OR AS AMENDED. Know what's below. Call before you dig. E O U O O1 co O a CDO M �O c) U U � U W � w z 3 MW 62 0 '> m 3 U W J ULL > Z< UO ^,— C V / LU LU 01 SCD Q O O U CD mw v O 186 (\^ � CO w Q Z W i Q � � c� a O O WN W aU r U_ O V) J � Cq O Q N W E S NORTH ARROW 0 15 30 60 GRAPHIC SCALE 1"=30 FT. �� �-•.•••�pNDs • p / Z��i�2022• � . .N C'7 LU o 00 -q 00 N U zo;z z � �� Q LU 1-0w > Q ^�^ I..L LU � LU F— LU Q:� V—) J \ Q � / m F— z� LU z I U QIL z REVISIONS: C07 - UTILITY.DWG PROJECT NUMBER: 221011 DATE: 2/4/2022 DRAWN BY: KIW C07 SHEET 12 OF C07 - UTILITY.DWG -PLOT: Kennedy -WED. 2-16-2022 8:47 AM