Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW3220302_Plansheet - Misc. Detail_20220308 (3)
ACCESSIBLE PARKING REQUIREMENTS MINIMUM NUMBER MINIMUM NUMBER OF TOTAL PARKING SPACES OF ACCESSIBLE SPACES ACCESSIBLE SPACES REQUIRED PROVIDED SPACES REQUIRED TO BE VAN ACCESSIBLE 1 TO 25 1 1 26 TO 50 2 1 51 TO 75 3 1 76 TO 100 4 1 101 TO 150 5 1 151 TO 200 6 1 201 TO 300 7 1 301 TO 400 8 1 401 TO 500 9 2 501 TO 1000 2%OFTOTAL 1 IN EVERY8 ACCESSIBLE SPACES 1001 AND OVER 20 PLUS 1 FOR 1 IN EVERY 8 EACH 100 OVER 1000 ACCESSIBLE SPACES SECTION 4.1.2 (5) OF THE AMERICANS WITH DISABILITIES ACT (ADA). SEE 4.1,2,(5) (d) FOR MEDICAL CARE FACILITIES NOTES: 1 . ALL 12"x18" ACCESSIBLE SIGNS (R7-8a & R7-1) SHALL BE MOUNTED AT 7 FEET FROM MOUNTING HEIGHT CAN BE REDUCED TO GRADE TO BOTTOM EDGE OF SIGN FACE (MUTCD). 5 FEET IF PLACED IN AN AREA BETWEEN SIDEWALK AND BUILDING FACE IN WHICH PEDESTRIANS ARE NOT EXPECTED TO USE. 2. REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, (MUTCD) U.S. DEPARTMENT OF TRANSPORTATION AND CITY / COUNTY / STATE DEPARTMENT OF TRANSPORTATION SUPPLEMENTS. 3. IF ACCESSIBLE ROUTE IS A RAISED SIDEWALK AREA, THEN RAMPS ARE REQUIRED AT LOADING ZONE AREA. CURB TAPER HANDICAP PARKING SIGN TYP. EA. SIDE CENTERED @ EACH SPACE 6' CONCRETE SIDEWALK CURB RAMP FLUSH W/ SIDEWALK CURB & GUTTER WH LINE AS 4" SEE a 8' --j� 5' 8' - 9'— H.C. SPACE OR 8' H.C. SPACE TYPICAL SEE PLAN SPACES (MIN.) O © © SIGNAGE R7-8e RESERVED ACCESSIBLE 12"x6" H PARKING MUTCD PARKING R7-1 12" W MUTCD RESERVED DISABLED /// R78a PARKING MUTCD PASSENGER / 12"x18" R7-8a LOADING 12"x18" ONLY REQUIRED ACCESSIBLE MAXIMUM R7-81D ACCESSIBLE ROUTE © (SEE NOTE 3) RESERVED PARKING SIGN L�$2 ENALTY 12'x9 ONE OUT OF EVERY EIGHT (8)ACCESSIBLE SPACES, BUT 50NOT LESS THAN ONE, IS REQUIRED TO BE VAN ACCESSIBLE. MAXIMUM PARKING SPACE PAVEMENT MARKINGS PENALTY R7-8D $ 250 12"x9" SEE STANDARD NO. 50.1OC FOR SUPPLEMENTAL SIGN DETAIL ACCESSIBLE PARKING AND SIGNAGE STANDARDS N.T.S. TE PAINTED S 'HALT PARKING DETAIL JOINT SEALER 1/8" RADIUS (TYPICAL) SURFACE OF GUTTER 1/8" d JOINT FILLER PAVEMENT N d° d 7„ 11„ v. NOTES: 1. CONTRACTION JOINTS SHALL BE SPACED AT 10-FOOT INTERVALS. JOINT SPACING MAY BE ALTERED BY THE ENGINEER TO PREVENT UNCONTROLLED CRACKING. 2. CONTRACTION JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, A MINIMUM DEPTH OF 1 1 /2" SHALL BE OBTAINED. 3. ALL EXPANSION JOINTS SHALL BE SPACED AT 90 FOOT INTERVALS, AND ADJACENT TO ALL RIGID OBJECTS. JOINTS SHALL MATCH LOCATIONS WITH JOINTS IN ABUTTING SIDEWALK. 4. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3600 P.S.I. IN 28 DAYS. 5. CURB SHALL BE DEPRESSED AT INTERSECTIONS TO PROVIDE FOR FUTURE ACCESSIBLE RAMPS. 6. TOP 6" OF SUBGRADE BENEATH THE CURB AND GUTTER SHALL BE COMPACTED TO 100% STANDARD PROCTOR DENSITY. 7. ALL CONC. TO BE 3,000 PSI (CLASS A) IN ACCORDANCE WITH ASTM C94-90. 8. ALL EXPOSED CONC. TO HAVE BROOM FINISH. STANDARD l'-6" CURB AND GUTTER N.T.S. 14' 1' I 12' 4' 4' 4' PROVIDE TWO STEEL BOLLARDS 12" MASONRY WALL fLINE OF FOOTING SHOWN DASHED PROVIDE HARDWARE FOR GATE AS REQ'D. TURN DOWN SLAB In I W/ 1 /2" E.J. '04, 66 6' 1 'v 12' Q a PLAN a Q n �8'� 81 H11 IIIIIIIIIIII�IIIII 1' VAR IES I. BRICK TO MATCH BUILDING BASE IN COLOR & COURSING 2x4 SMOOTH SAWN CEDAR GATE ELEVATION NOTE: OTHER THREE ELEVATIONS ARE SIMILAR OF ELEVATION SHOWN, WITH CONTINUOUS WALL CONSTRUCTION IN LIEU OF GATE. 12 ROWLOCK BRICK @ TOP PAINT INTERIOR CMU TO MATCH BRICK 4" BRICK FACE W/ 8" CMU BACK-UP W/ #4'S VERT. @ CORNERS AND EACH SIDE OF GATE. FILL CELLS SOLID W/ 3000 PSI PEA GRAVEL CONC. WHERE BARS OCCUR. 1/2" EXPASION JOINT SLOPED CONCRETE SLAB SLAB 0 oSTONE DUMPSTER PAD STANDARD 2'-0" WIDE x 10" MIN. DEEP CONCRETE FOOTING W/ 2 #4'S SHALL BE INSTALLED 16" CONTINUOUS. TOP OF WALL SECTION FOOTING BELOW GRADE SINGLE DUMPSTER ENCLOSURE DETAIL N.T.S. NOTES: 1. REMOVE WIRE OR NYLON TWINE FROM BALL 2. INSTALL TOP OF BALL 2" ABOVE FINISH GRADE 3. SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION 4. IF STAKING IS REQUIRED USE DETAIL FOR STD. NO. 40.01 5. 4" SAUCER WILL BE OUTSIDE OF BACKFILL. 6. SEE SPECIFICATIONS FOR OTHER PLANTING REQUIREMENTS. 7. ADDITIONAL INFORMATION ON TREE PLANTING AND PRESERVATION IS AVAILABLE IN THE LANDSCAPE CONSTRUCTION STANDARDS (CITY OF CHARLOTTE) TOP OF ROOT BALL TO BE 2" ABOVE FINISH GRADE 4" LAYER OF MULCH- NO MORE THAN 4" TOUCHING TRUNK. 4" HIGH WATER BERM FINISH GRADE REMOVE TOP 1/3 OF WIRE BURLAP, AND ANY NAILS/PINS, ETC. PLANTING MIX REMOVE TOP 2/3 OF WIRE BASKET (AS SPECIFIED) WHERE PRESENT UNDISTURBED SOIL LINE (IF SOIL HAS BEEN $ 20" 6" 8" PREVIOUSLY DISTURBED, FIRM SOIL UNDER 48" ROOT BALL) ALL TREES SHALL MEET AMERICAN STANDARD FOR NURSERY STOCK (ANSI, 1990, PART 1, "Shade and Flowering Trees") For Example: Caliper Height (range) Max. height Min. root ball dia. Min. root ball depth 2" 12-14' 16' 24" 16" 3" 14-16' 18' 32" 21 " NOTES: 1. MINIMUM TREE SIZE AT PLANTING IS 2 - 2.5 INCH CALIPER & 10 - 12 FEET IN HEIGHT FOR SHADE TREES AND 1.5 - 2 INCH CALIPER FOR ORNAMENTAL TREES (6' MINIMUM HEIGHT AT PLANTING). 2. ALL STRAPPING AND TOP 2/3 OF WIRE BASKET MUST BE CUT AWAY AND REMOVED FROM ROOT BALL PRIOR TO BACKFILLING PLANTING PIT. REMOVE TOP 1 /3 OF THE BURLAP FORM ROOT BALL. 3. FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB -BASE AND CONSTRUCTION DEBRIS; REMOVE COMPACTED SOIL AND ADD 18" NEW TOPSOIL OR UNCOMPACT AND AMEND THE TOP 24" OF EXISTING SOIL TO MEET TOPSOIL/PLANTING MIX STANDARDS FOR TREES (WITHIN ENTIRE MINIMUM AREA OF 274 SF PER TREE) PLANTING DETAIL -SINGLE STEM TREE N.T.S. CONCRETE SLAB OR PAVEMENT HEAVY DUTY, DUCTILE IRON LOCKING GRATE 10" MIN. - REMOVABLE SPACER VARIES / \\\ \\\ p p v � AQUEDUCT ..�CHANNEL /\/ DRAIN GRATE SHALL BE RATED FOR VEHICULAR AREA USE AQUEDUCT TRENCH DRAIN DETAIL SECTION N.T.S. )I CUING -Kilt l_v ZO UATJ DMPACTED SUBGRADE STIFF BROOM FINISH PERPENDICULAR TO TRAFFIC FLOW HAND TROWEL SCORE JOINT W/ TOOL BANDING 1" DEEP Lu LuJ _ W ~ m w m w N 04 N '-- R3' 1 /2" BIT. EXP JT PROVIDE 1 /2" BIT. EXPANSION JOINT @ 25' O.C.(SEALED) NOTE: PROVIDE 1 /2" BIT. EXPANSION JOINTS @ 25' O.C. (SEALED) & WHEN CONCRETE ABUTS A RIGID SURFACE. (i.e. WALLS, CURBS) TYP. SCORING PATTERN @ INTERSECTIONS CONCRETE SIDEWALK DETAIL N.T.S. PLAN ANGLE FRAME SYSTEM WITH ANCHORS COURSE 2" INTERMEDIATE COURSE ASPHALT �����•�t�1,�1�S���t�l,i�il��i� ��i1� �i 1�'}�i I�l�i��`i•�i I�l�`t��it�i1� i 8" AGGREG BASE COURSE (ABC) COMPACTED SUBGRADE HEAVY DUTY ASPHALT PAVING N.T.S. PAVEMENT RECOMMENDATIONS BASED ON GEOTECH REPORT REFER TO GEOTECH REPORT FOR FURTHER INFORMATION ON PAVEMENT SPECIFICATION - GEOTECH REPORT SPECIFICATION SHALL BE USED N.T.S. PAVEMENT RECOMMENDATIONS BASED ON GEOTECH REPORT REFER TO GEOTECH REPORT FOR FURTHER INFORMATION ON PAVEMENT SPECIFICATION - GEOTECH REPORT SPECIFICATION SHALL BE USED C O U (D O 1,11 c rn CD O 10?' O CO U N � U N ) W of LL z 0>�3U 3 W W J U No in — Cie U n` _ O J m 5 QZ u L mW O N 00 Z Ln ) 00 x O -4 O w QOr z �Q ^^`` (D W N Q Q (D U Ct 3n z Q U J -0 r N — Z c rL0 J � 00 CD Q (y) LJJ CD 00 --zj- 00 CV U z CD °' z v) LJJ L0 Lu LL LJJ CD CD 1-0 / Z W 0 Lu Lu Lu W LJJ Lu CL 00 z v) Lu z U Q C z REVISIONS: C09 - DETAILS.DWG PROJECT NUMBER: 221011 DATE: 2/4/2022 DRAWN BY: KIW SHEET C OF 12 C09 - DETAILS.DWG - PLOT: Kennedy - WED. 2-16-2022 8:47 AM