Loading...
HomeMy WebLinkAboutSW4220501_Supplement-EZ Form_20220510SUPPLEMENT-EZ COVER PAGE FORMS LOADED rrcvdo�, 1 r uvrvrcrvw r rvry Project Name 2 Project Area ac 3 Coastal Wetland Area ac 4 Surface Water Area ac 5 Is this project High or Low Density? 6 Does this project use an off -site SCM? COMPLIANCE WITH 02H .1003(4) 7 Width of ve etated setbacks provided feet 50 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMS: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader -Filter Strip LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Ba filter 2 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: GREGORY R. HOFFMAN, P.E. 28 Organization: CIVIL DESIGN CONCEPTS, PA 29 Street address: 168 PATTON AVE 30 City, State, Zip: ASHEVILLE, NC 28801 31 Phone numbers : 828 252-5388 32 Email: GHOFFMAN@CDCGO.COM Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. \1`yt11111lI!!!� ,ACAp6' ,,, F -SSI °°° i SEAL o 035093 o 2 z Ajer � Sig ature of Designer Date DRAINAGE AREAS 1 Is this a high density pro ect? Yes 2 If so number of drainage areas/SCMs 2 3 Does this project have low density areas? No 4 If so number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 4 Type of SCM Ba filter Ba filter 5 Total drainage area (sq ft 223953 197022 26931 6 Onsite drainage area (sq ft 223953 197022 26931 7 Offsite drainage area (sq ft N/A N/A N/A 8 Total BUA in pro ect (sq ft 184999 sf 163350 sf 21649 sf 9permitting) New BUA on subdivided lots (subject to s ft N/A N/A N/A 10 New BUA not on subdivided lots (subject to ermittin sf N/A N/A N/A 11 Offsite BUA (sq ft N/A N/A N/A 12 Breakdown of new BUA not on subdivided lots: - Parking (sq ft 13446 sf 13446 sf sf - Sidewalk (sq ft 10846 sf 10846 sf sf - Roof (sq ft 74390 sf 74390 sf sf - Roadway s ft 86317 sf 64655 sf 21662 sf - Future (sq ft N/A N/A N/A - Other, please specify in the comment box below (sq ft N/A N/A N/A 13 New infiltrating permeable pavement on subdivided lots (sq ft N/A N/A N/A 14 New infiltrating permeable pavement not on subdivided lots (sq ft N/A N/A N/A 15permitting) Existing BUA that will remain (not subject to s ft N/A N/A N/A 16 Existing BUA that is already permitted (sq ft N/A N/A N/A 17 Existinq BUA that will be removed (sq ft N/A N/A N/A 18 Percent BUA 82% 83% 80% 19 Desi n storm inches 1.0 in 1.0 in 1.0 in 20 1 Design volume of SCM cu ft 9800 cf 1303 cf 21 lCalculation method for design volume 1" WQV 1" WQV ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): BAYFILTER 1 Drainage area number 1 2 2 Minimum required treatment volu me cu ft 9800 cf 1303 cf GENERAL MDC FROM 02H .1050 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes 3 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM (H:V)? N/A N/A 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? N/A N/A 7 Are the inlets, outlets, and receiving stream protected from erosion 10- ear storm)? Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? N/A N/A 11 Does the maintenance access comply with General MDC (8)? Yes Yes 12 Does the drainage easement comply with General MDC 9 ? Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? Yes Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC 12 ? Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM desi ned by an NC licensedprofessional? Yes Yes BAYFILTER MDC FROM THE STORMWATER DESIGN MANUAL 18 If Volume Design is used, what is the volume from the drainage area (cubic feet)? 9800 cf 1303 cf 19 Is an upstream detention used? Yes Yes 20 Volume of the upslope detention system (cubic feet) 4699 cf 1407 cf 21 Percent of the design volume contained in the upslope detention s stem 46% 100% 22 If Rate Based Sizing is used, for 1 inch or 1.5 inch (Coastal areas). Water Quality flow rate for drainage area cfs N/A N/A 23 Number of cartridges 8 1 24 Cartridge height (inches) 22 in 22 in 25 SHWT elevation fmsl 2665 2665 26 Elevation of bottom of Ba Filter vault fmsl 2667.65 2667.65 27 Clearance from the SHWT (feet) 2.65 ft 2.65 ft 28 BayFilter Media Flow Rate (GPM/ft2 of Media Surface) .5 gpm/sf .5 gpm/sf 29 Does the system includes a sediment sump? No No 30 If yes, the diameter of the sum feet N/A N/A 31 If yes, the depth of the sump (feet) N/A N/A 32 Time to drain the sump (hours) N/A N/A 33 Time to drain the Ba Filter hours 27.5 hrs 25 hrs 34 Is an off-line flowsplitting device used? No No 35 Type of media used (EMC or GAC-metals) EMC EMC 36 "r" maintenance be performed by Certified Maintenance Providers er instructions? Yes Yes ADDITIONAL INFORMATION 37 Please use this space to provide any additional information about the Ba Filters stems :