Loading...
HomeMy WebLinkAboutNCG140506_Site Layout Map_20220505ADJACENT PROPERTY OWNERS LOCATION MAP SCALE : 1" = 2000' SITE DATA ZONING: R-17MF, 1-1, & 1-2 EXISTING: QUARRY & MANUFACTURE OF ASPHALT PROPOSED: QUARRY& MANUFACTURE OF CONCRETE PARCEL ID # : 20513102 GIB ID # :20513102 ZONING JURISDICTION: CHARLOTTE DEED BOOK -PAGE: 11362-675 LAND OWNER: VULCAN LANDS INC. ACREAGE: 161.12 (DATA FROM TAX DEPARTMENT) DRAINAGE BASIN: CENTRAL CATAWBA DISTRICT PROJECT DATA DEVELOPER: BLUE DOT READI-MIX, LLC ADDRESS: 11330 BAIN SCHOOL ROAD MINT HILL, NC 28227 PHONE # : 704-971-7676 PROJECT ADDRESS: 10500 OLD NATIONS FORD ROAD PROPOSED USEADDITION: CONCRETE MANUFACTURING FACILITY HEIGHT: 13'-5 3/8" (BUILDING) 82'-2" (SILO) NO. OF PARKING SPACES REQUIRED: AUTO: 6 (2,400 SQ. FT./400) SHOP BUILDING 6 (2,227 SQ. FT./400) OFFICE BUILDING LOADING SPACES: 1 LONG TERM BICYCLE 2 SHORT TERM BICYCLE:2 PARKING PROPOSED: 11 REGULAR SPACES 1 VAN ACCESS. HANDICAP SPACE LOADING SPACES: 1 LONG TERM BICYCLE: 2 (INTERIOR STORAGL, SHORT TERM BICYCLE: 2 (EXTERIOR) DENUDED AREA: N/A (EXISTING QUARRY- MINE PERMIT NO. 60-05) TREE SAVE AREA: OFFSITE MITIGATION SITE NOTES: 1. THIS PROPERTY IS INCLUDED IN MINING PERMIT #60-05, ISSUED BY NC DEQ. SITE DISTURBANCE IS REGULATED BY THE MINING ACT AND EXEMPT FROM THE REQUIREMENTS OF THE SEDIMENT POLLUTION CONTROL ACT. 2. THE SITE IS LOCATED ON A TRACT OF LAND WITH A FEMA DESIGNATED FLOODPLAIN AND THE MAJORITY OF THE PROJECT AREA IS IMPERVIOUS AREA. STORM WATER DETENTION IS BEING PROVIDED BY STORAGE IN THE QUARRY PIT. 3. THE LOCATION OF THE EXISTING PRIVATE 6" WATER LINE IS BASED ON PLANS PREPARED BY ESP AND ASSOCIATES. THE LOCATION OF THE EXISTING HYDRANT AND BACKFLOW DEVICE IS BASED ON FIELD SURVEYS BY OTHERS. THE LOCATION OF THE OFFICE BACKFLOW PREVENTER AND SERVICE LINE IS BASED ON CONSTRUCTION PLANS AND A SURVEY BY ASCENSION LAND SURVEYING, PC AND IS SHOWN IN IT'S APPROXIMATE LOCATION. 4. THE DISTURBED AREA IS COLLECTED IN EXISTING SETTLING PONDS AND TREATED. ADDITIONAL EROSION CONTROL MEASURES, OTHER THAN NOTED ON THE PLANS ARE NOT REQUIRED. 5. THE ENTRANCE/EXIT FOR THE CONCRETE PLANT IS PROVIDED BY EXISTING CONNECTIONS TO OLD NATIONS FORD ROAD. 6. THIS PLAN DOES NOT PURPORT TO SHOWN ALL EXISTING UTILITIES, LINES, APPURTENANCES, ETC., AND THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES, PIPES, VALVES, ETC., AS SHOWN ARE IN A APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE ENGINEER. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES, LINES, PIPES, ETC., BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES, PIPES AND VALVES. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY CONFLICTS WITH EXISTING OR PROPOSED FACILITIES TO DETERMINE IF AN ITEM WILL NEED TO BE RELOCATED. 7. THE ENGINEER HAS MADE NO EXAMINATION TO DETERMINE WHETHER ANY HAZARDOUS OR TOXIC MATERIALS ARE PRESENT OR CONTAINED IN, UNDER OR ON THE SUBJECT PROPERTY OR ITS WATERS, OR IF ANY HAZARDOUS OR TOXIC MATERIALS HAVE CONTAMINATED THIS OR OTHER PROPERTIES OR ITS WATERS IN ANY WAY WHATSOEVER, NO SUBSURFACE EXAMINATION OF ANY TYPE HAS BEEN MADE BY THE ENGINEER, AND ACCORDINGLY, NO OPINION IS RENDERED AS TO ANY VIOLATION OF ANY ENVIRONMENTAL LAWS OR REGULATIONS, EITHER FEDERAL, STATE, OR LOCAL RELATED TO THE INFORMATION SHOWN ON THIS PLAN AND THE ENGINEER IS IN NO WAY LIABLE FOR ANY VIOLATION OF SUCH ENVIRONMENTAL LAWS SHOULD SUCH EXIST. 8. THIS PROPERTY HAS FLOOD FRINGE AND FLOODWAY AREAS AS SHOWN ON FIRM PANEL #3710453000L, EFFECTIVE 9/02/15. 9. BENCHMARK LOCATIONS AND ELEVATIONS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO BEGINNING CONSTRUCTION. 10. TO ENSURE PROPER LOCATION OF EXISTING UTILITIES, THE CONTRACTOR SHALL CONTACT NC ONE CALL (1-800-632-4949, AT LEAST 48-HOURS PRIOR TO CONSTRUCTION. 11. THE CONTRACTOR SHALL PROVIDE APPROPRIATE BARRICADES, WARNING LIGHTS, AND WARNING SIGNS TO ENSURE THE SAFETY OF THE PUBLIC AT ALL TIMES. 12. THE CONTRACTOR SHALL VERIFY ALL SOIL CONDITIONS PRIOR TO CONSTRUCTION. 13. VERTICAL DATUM DESCRIPTION: THE ELEVATIONS ARE BASED ON NAVD 88 DATUM. 14. LOCATIONS OF ZONING BOUNDARIES AREA BASED ON MECKLENBURG COUNTY GIS DATA. 15. THE LOCATIONS OF FEMA FLOODPLAIN AND FLOODWAY ARE BASED ON MECKLENBURG COUNTY GIS DATA. 16. ALL PLANT EQUIPMENT IS NOT SHOWN ON THIS SHEET. TOPOGRAPHICAL NOTES: 1. AERIAL PHOTOGRAPHY AND TOPOGRAPHICAL DATA PROVIDED BY TUCK MAPPING SOLUTIONS, INC. DATE OF PHOTOGRAPHY IS 2-8-21. �1 f� LORETTA WALLACE 1D PARCEL ID: 20304641 ZONING: R-4 MARY JANE HILL ROBINSON 02 PARCEL ID: 20304542 ZONING: R-4 AMOS WILLIAMS JR ® PARCEL ID: 20304541 ZONING: R-4 WAYNE MORRISON ® PARCEL ID: 20304539 ZONING: R-4 JAMES F LOMAS ® PARCEL ID: 20304538 ZONING: R-4 YANET LOURDES RUIZ SOSA © PARCEL ID: 20304537 ZONING: R-4 MARTHA R MCCULLOUGH PARCEL ID: 20304536 ZONING: R-4 HORACE & ANNIE D GUNN ® PARCEL ID: 20304535 ZONING: R-4 SITE LEGEND PROPERTY LINE ADJACENT VMC PROPERTY LINES FEMA FLOODWAY FEMA COMMUNITY ENCROACHMENT LINE (0.1) FEMA FLOOD FRINGE LINE FEMA FUTURE CONDITIONS FLOOD FRINGE LINE FEMA CROSS-SECTION LINE 30' STREAM SIDE S.W.I.M. BUFFER 45' MANAGED USE S.W.I.M. BUFFER UPLAND S.W.I.M. BUFFER / PCCO VEGETATED NO BUILD ZONE 5' 1-1/1-2 BUILDING SETBACK ZONING BOUNDARY BLUE DOT READI-MIX LLC TENANT LEASE AREA FER / PCCO NO 236 1. THE STREAM SIDE ZONE OF THE BUFFER MUST BE LEFT COMPLETELY UNDISTURBED. IN THE MANAGED USE ZONE, A LIMITED NUMBER OF TREES CAN BE REMOVED PROVIDED THAT THE TREE DENSITY REMAINING IS A MINIMUM OF 8 HEALTHY TREES OF A MINIMUM 6 INCH CALIPER PER 1000 SQUARE FEET. THESE TREES SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE MANAGED USE ZONE. REMOVAL OF EXISTING VEGETATION MUST BE PERFORMED BY HAND IN SUCH A MANNER AS TO PREVENT DAMAGE TO THE ROOTS OF REMAINING TREES. NO HEAVY EQUIPMENT IS PERMITTED IN THE MANAGED USE OR STREAM SIDE ZONES EXCEPT FOR APPROVED INSTALLATION OF UTILITIES. NO FILL MATERIAL CAN BE BROUGHT INTO ANY OF THE BUFFER ZONES. NO GRUBBING IS ALLOWED IN THE MANAGED USE OR STREAM SIDE ZONES. 2. GRADING AND OTHER LAND DISTURBING ACTIVITIES ARE ALLOWED ONLY IN THE UPLAND ZONE; HOWEVER, THESE ACTIVITIES MUST BE PERFORMED IN SUCH A MANNER AS TO PREVENT DAMAGE TO THE ROOTS OF REMAINING TREES. GRASS OR OTHER SUITABLE GROUND COVER CAN BE APPLIED TO THE UPLAND ZONE. 3. THE OUTSIDE BUFFER BOUNDARY MUST BE CLEARLY MARKED BY ORANGE FABRIC FENCING PRIOR TO ANY LAND DISTURBING ACTIVITIES AT THE SITE AND THIS FENCING MUST BE CALLED OUT ON THE PLANS. IN SITUATIONS WHERE THE DISTURBED UMITS OF A DEVELOPMENT OCCUR PRIOR TO THE S.W.I.M. STREAM BUFFER, THE ORANGE FABRIC FENCING MAY BE INSTALLED AT THE EDGE OF THE DISTURBED AREA AND PRIOR TO THE OUTSIDE EDGE OF THE BUFFER. 4. THE OUTSIDE BOUNDARY OF THE STREAM BUFFER MUST BE PERMANENTLY MARKED WITH AN IRON PIN OR OTHER ACCEPTABLE PROPERTY CORNER MARKER AT STREET CROSSINGS AND THIS MARKER MUST BE CALLED OUT ON PLANS. 5. THE LOCATIONS OF THE S.W.I.M. STREAM BUFFERS AND PCCO VEGETATED NO BUILD ZONE ARE BASED ON THE ORDINANCE DEFINITIONS AND CHARLOTTE LAND DEVELOPMENT SERVICES S.W.I.M. BUFFER CHECKLIST. THE LOCATION OF THE BUFFERS HAVE NOT BEEN ADJUSTED TO REFLECT THE EXEMPTIONS FOR EXISTING QUARRY DEVELOPMENT OR AREAS APPROVED FOR MINING ACTIVITIES BY NC DIED UNDER A MINE PERMIT. 6. DRAINAGE OUTFALLS MUST BE DESIGNED TO ALLOW WATER TO SHEET FLOW ACROSS THE BUFFER TO FILTER OUT POLLUTANTS. alley, williams, carmen, & king, inc. CONSULTING ENGINEERS FIRM LICENSE No. F-0203 120 SOUTH MAIN STREET P.O. BOX 1 KANNAPOLIS, NC 28082 704/938-1515 15 SITE LAYOUT MAP BLUE DOT READI-MIX PLANT BLUE DOT READI-MIX, LLC 10500 OLD NATIONS FORD ROAD CHARLOTTE, NORTH CAROLINA ESS SEAL = 16883 (�DocuS1l9��nledby: %i01N6���00��, 11% Wea�.e�. Oak "',',' SIEY �����`� 2/I1/2022 3AOD005HSA54013... SCALE V = 200' PROFILE 2-11-22 V B.. RCC (m BY: G W W NO.:21549 Blue Dot Site Plan.dwo JOB NO. 21549 SHEET NO. c 1