HomeMy WebLinkAboutNCG550783_Compliance Evaluation Inspection_20220505 North Carolina Department of Environmental Quality Division of Water Resources
Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609
919.791.4200
May 5, 2022
Victor Pickard
1403 Farmview Road
Hillsborough, NC 27278
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG550783
Facility: 5620 Blue Spruce Drive
Durham County
Dear Mr. Pickard:
On May 2, 2022, Stephanie Goss from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject General
NPDES Permit. You were contacted to schedule an inspection via telephone and the number is
no longer in service and a mailed letter with no response.
Our records indicate the treatment system consists of a septic tank, Advantex sand filter, UV
disinfection and discharge pipe.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550783 authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as an unnamed tributary to Crooked Creek classified a WS-IV, Nutrient Sensitive Waters (NSW)
in the Neuse River Basin. The authorized discharge is in accordance with the effluent limits and
monitoring requirements established within the General Permit. Findings during the inspection
were as follows:
1. Treatment system operation: The wastewater treatment system shall be maintained at all
times to prevent seepage of sewage to the surface of the ground.
2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks should
be pumped out every five years or when the solids level is found to be more than 1/3 of the
liquid depth in the septic tank compartment, whichever is greater. A pumping company can
check the status periodically and determine when pumping is required. Within 30-days of
receiving this letter, please send a copy of the most recent receipt/invoice to this office
showing the date the septic tank was last checked and/or pumped out. The General NPDES
Permit requires the permittee to retain records associated with sewage disposal activities for a
period of at least 5 years.
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
North Carolina Department of Environmental Quality Division of Water Resources
Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609
919.791.4200
Page | 2
3. UV Disinfection: Your system uses an ultra-violet (UV) light system for disinfection of the
discharged wastewater. New rules put into place on August 1, 2007 require all SFR systems
to have a means of disinfection (and dechlorination when chlorine tablets are used to
disinfect, if the system was installed since that date). A UV disinfection system provides
effective disinfection and prevents/limits harmful bacteria from discharging to the
environment. Unless the UV disinfection unit is monitored by telemetry, the unit shall be
checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to
ensure proper disinfection of the discharged wastewater. Please ensure the UV disinfection
unit is properly operated and maintained to ensure optimal performance.
4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within
General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving
his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed
include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform,
Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous. Within
30-days of receiving this letter, please let this office know if you have monitored your
effluent discharge within the last 12 months and provide this office with a copy of the lab
results if you have. If you have not monitored your effluent, then please collect a
representative sample of the effluent, have it analyzed by a certified commercial laboratory
and submit the results to this office no later than August 31, 2022. If, during this time, you
are unable to collect a representative sample of the effluent discharge due to insufficient flow
from the discharge pipe, then update this office with that information and continue to monitor
the discharge and if conditions for sampling become favorable, then arrange to collect a
sample. Failure to monitor the effluent discharge as required is a violation of NPDES
General Permit NCG550000.
5. Discharge outlet location. The permittee is required to conduct a visual review of the outfall
location at least twice each year (one at the time of sampling) to ensure that no visible solids
or other obvious evidence of system malfunctioning is observed. Any visible signs of a
malfunctioning system shall be documented, and steps taken to correct the problem. The end
of discharge pipe was not visible nor accessible the day of the inspection. To comply with
the general permit monitoring requirements, you need to be able to sample and analyze the
effluent from your SFR system through the discharge pipe. You need to keep the area
around the discharge pipe cleared of vegetation, soil and leaves. Please take the necessary
steps to ensure the discharge outlet is visible and accessible. Maintaining the area will allow
you to monitor the discharge and to collect effluent samples as required by the subject
permit.
Division records indicate the required annual fee ($60 per year) for the period ending February
28, 2010 and due December 2, 2021 has been paid. There are no overdue fees for the subject
COC.
The wastewater treatment system should be periodically inspected to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all monitoring data and associated maintenance records onsite for a minimum of
three years and available for inspection.
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
North Carolina Department of Environmental Quality Division of Water Resources
Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609
919.791.4200
Page | 3
Within 30-days receipt of this letter, please submit a written response to this office indicating
the actions you will take or have taken to comply with or resolve the issues noted items 2-5
above.
If you have questions or comments about this inspection or the requirements to take corrective
action (if applicable), then please contact via email at stephanie.goss@ncdenr.gov or 919-791-
4256.
Sincerely,
Vanessa E. Manuel Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
Cc: RRO/SWP Files
Laserfiche
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NCG550783 22/05/02 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
5620 Blue Spruce Drive
5620 Blue Spruce Dr
Durham NC 27712
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
12:08PM 22/05/02 21/08/19
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
12:17PM 22/05/02 25/10/31
Name, Address of Responsible Official/Title/Phone and Fax Number
Victor Pickard,1403 Farm View Rd Hillsborough NC 27278//919-417-8417/Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Operations & Maintenance Records/Reports Self-Monitoring Program Facility Site Review
Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Stephanie Goss DWR/RRO WQ/919-791-4200/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
5/5/2022
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
5/5/2022
NPDES yr/mo/day
22/05/02
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
NCG550783 17
Page#2
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
Permit:NCG550783
Inspection Date:05/02/2022
Owner - Facility:
Inspection Type:
5620 Blue Spruce Drive
Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain-of-custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Page#3
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
Permit:NCG550783
Inspection Date:05/02/2022
Owner - Facility:
Inspection Type:
5620 Blue Spruce Drive
Compliance Evaluation
Effluent Pipe Yes No NA NE
The effluent pipe was not visible during the inspection.Comment:
Disinfection - UV Yes No NA NE
Are extra UV bulbs available on site?
Are UV bulbs clean?
Is UV intensity adequate?
Is transmittance at or above designed level?
Is there a backup system on site?
Is effluent clear and free of solids?
Comment:
Septic Tank Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Comment:
Sand Filters (Low rate)Yes No NA NE
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re-circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1)
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
Page#4
DocuSign Envelope ID: 97A898A5-3909-4842-829F-4D7AE8797C48
Permit:NCG550783
Inspection Date:05/02/2022
Owner - Facility:
Inspection Type:
5620 Blue Spruce Drive
Compliance Evaluation
Effluent Sampling Yes No NA NE
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment:
Page#5