HomeMy WebLinkAboutSW3211202_Plansheet - Misc. Detail_20220223Old Pageland — Monroe Road Solar Farm, LLC
919 Old Pageland Monroe Road
Monroe, NC 28112
Union County
SOLAR PANEL AND RACKING SYSTEM DETAILS
1. Typical Solar Panel Detail
The project fixed tilt Solar PV system complies with NCDEQ Stormwater Design Manual Section E-6 Solar Farms.
• Recommendation 2: Disconnect runoff from solar panel arrays (DL Ratio = 85% >_ 80%);
>See calcualtions with Figure 1 dimensions: Solar Panel Width = 12.94 ft; Row Spacing: 11 ft; Average Slope = 1%
• Recommendation 6: Limit vertical clearance to <_ 10 feet (per below, max. vertical height is 6 ft — 7 % in). This
detail is provided to show vertical height clearances and module install configuration. See Detail #2 for typical
racking support design.
T GAt W SOLAR NODULE
INSTALLED IN PORTRAIT PO mm
TYPICAL TWO IN A ROW
FAS RACK BY LEGRAND
s PV SOLAR RACKING DETAILS
L. j SFxE: Nis
2. Typical GM-1 Single Post Portrait Detail
Per Ground Mount System Model GM -I Assemby Instructions Manual (Page 3, RBI Solar www.rbisolar.com)
Module Dimensions: 76.93 x 38.7x1.57 inches (Quartech Max Power CS6X-310/315/320P; Canadian Solar, Inc.)
MODULE 1 MECHANICAL DATA
SINGLE POST Specification Data
Cell Type Poly -crystalline, 6 inch
PORTRAIT Cell Arrangement 72 (6 x 12)
Dimensions 1954x982x40mm(76.93x38.7x1.57in)