Loading...
HomeMy WebLinkAboutSW3211202_Plansheet - Misc. Detail_20220223Old Pageland — Monroe Road Solar Farm, LLC 919 Old Pageland Monroe Road Monroe, NC 28112 Union County SOLAR PANEL AND RACKING SYSTEM DETAILS 1. Typical Solar Panel Detail The project fixed tilt Solar PV system complies with NCDEQ Stormwater Design Manual Section E-6 Solar Farms. • Recommendation 2: Disconnect runoff from solar panel arrays (DL Ratio = 85% >_ 80%); >See calcualtions with Figure 1 dimensions: Solar Panel Width = 12.94 ft; Row Spacing: 11 ft; Average Slope = 1% • Recommendation 6: Limit vertical clearance to <_ 10 feet (per below, max. vertical height is 6 ft — 7 % in). This detail is provided to show vertical height clearances and module install configuration. See Detail #2 for typical racking support design. T GAt W SOLAR NODULE INSTALLED IN PORTRAIT PO mm TYPICAL TWO IN A ROW FAS RACK BY LEGRAND s PV SOLAR RACKING DETAILS L. j SFxE: Nis 2. Typical GM-1 Single Post Portrait Detail Per Ground Mount System Model GM -I Assemby Instructions Manual (Page 3, RBI Solar www.rbisolar.com) Module Dimensions: 76.93 x 38.7x1.57 inches (Quartech Max Power CS6X-310/315/320P; Canadian Solar, Inc.) MODULE 1 MECHANICAL DATA SINGLE POST Specification Data Cell Type Poly -crystalline, 6 inch PORTRAIT Cell Arrangement 72 (6 x 12) Dimensions 1954x982x40mm(76.93x38.7x1.57in)