HomeMy WebLinkAboutSW5220302_Plansheet C5.7 - SCM Detail_20220406SOD INSIDE BANKS AND BOTTOM 1 1 �1 100-YR STORM ELEV=427.73 10-YR STORM ELEV=427.69 PVC CLEANOUT 2' ABOVE PLANTING SURFACE WITH 2-YR STORM ELEV=427.64 GLUED FITTINGS AND RIM ELEV: 427.22' 1-YR STORM ELEV=427.49 SCREW CAP (TYP.) ----------------- --- TOP OF SOD ELEV: 425.62' OUTLET STRUCTURE BIORETENTION ~ PLANTING SOIL SEED & MULCH EMBANKMENT SEE SEEDING SCHEDULE (INSTALL SLOPE PROTECTION MATTING ON ALL SLOPES STEEPER THAN 6: 1) 10' TOP OF EMBANKMENT ELEV: 429.20' SOD INSIDE BANKS AND BOTTOM\ - �I III-"' SPILLWAY WEIR: 428.00' ' 1 3 / =ICI ICI =- PROPOSED MANHOLE d C2 (SEE SHEET C4.0) a 99' ° 8 ° ° d d d ° ° a °d d / d \ ANCHOR d DRAWDOWN \ / PIPE TO WALL ° ° d \ d d / 12" 6"PVC °° ° \\ ° e I ' d 6" PVC UNDERDRAIN 6" PVC END CAP I INV=421.99 ° 6" PVC TEE WATERTIGHT ° d NON -SHRINK ° ° ° d d GROUT ° ° Ad d / \ a °° a d d ° e ° a / ° d° d e / \ \ \ UNDERDRAIN ELBOW \ ENLARGEMENT \ \ \ RIM ELEV.: 427.22 PLAN VIEW \ -11 C ° IMPERVIOUS SEFFILL / IMPEORVIO US d N 7 1 - - - - - - - - - - - - - - - - - - - - --------------------------- BARREL OUTLET 49 LF OF 18" RCP WITH RUBBER GASKET (ASTM C-443) INV ELEV.: 421.99' - - - - - - - - - - - - - - - - - - - - - - -4 - I INV IN=419.90 NOTE \LL / EMBANKMENT SHALL BE CONSTRUCTED OF CLEAN STRUCTURAL SOIL, FREE OF ONE CONC. ANTI -SEEP COLLAR (6" WIDE) ROOTS, VEGETATION, ROCKS & OTHER OBJECTIONABLE MATERIAL. SCARIFY \ UNDER CENTER OF EMBANKMENT SURFACES BEFORE PLACING FILL. PLACE FILL IN 6-8 INCH LOOSE LIFTS. COMPACT TO AT LEAST 95% OF THE STANDARD PROCTOR DENSITY. BIORETENTION BASIN CONSTRUCTION SHALL BE UNDER THE SUPERVISION OF , • • • z \ d THE OWNERS GEOTECHNICAL CONSULTANT. / ; •• • \ . • . N BIO-RETENTION AND EMBANKMENT SECTION ° •' SCALE: N.T.S. •1 • ••• 24" RCP • d •°• j\ d • d \ \ Al N / A.a• • ANTI -SEEP COLLAR \ \ ENLARGEMENT / WELDED ALUMINUM BAR GRATING 3" x 3" OPENINGS PEAKED ROOF TRASH RACK A: MATERIAL: ALUMINUM WITH 25 YEAR DESIGN LIFE ° I 4'-0" e (6) 1/2" X 4" d ° STAINLESS STEEL d BOLTS PER SIDE (TYP). UPTURNED ELBOW SOD ELEV.: 425.62 ON 6" UNDERDRAIN d I_ PIPE (4) 5" MIN. WALL (TYP) ° / d d a \ e d/ ° d ' O/ • UNDERDRAINS tLtV. ° Al ° d ADDITIONAL CLASS B CONCRETE IN BOTTOM OF ° ° d , AA d STUCTURE d ° Lo ° ° ° a da ._ SECTION X-X DAM EMBANKMENT CONSTRUCTION STANDARDS 1. CONTROLLED FILL, AS SPECIFIED BY THE GEOTECHNICAL ENGINEER, IN THE DAM EMBANKMENT SHALL BE PLACED IN 6-INCH LOOSE LAYERS (3-INCH LOOSE LAYERS WITHIN 3-FEET OF EITHER SIDE OF THE PRINCIPAL SPILLWAY PIPE TO A DEPTH OF 2-FEET OVER THE PIPE) AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. 2. ALL VISIBLE ORGANIC DEBRIS SUCH AS ROOTS AND LIMBS SHALL BE REMOVED FROM THE FILL MATERIAL PRIOR TO COMPACTION TO THE REQUIRED DENSITY. SOILS WITH ORGANIC MATTER CONTENT EXCEEDING 5% BY WEIGHT SHALL NOT BE USED. STONES GREATER THAN 3-INCH (IN ANY DIRECTION) SHALL BE REMOVED FROM THE FILL PRIOR TO COMPACTION. 3. FILL MATERIAL PLACED AT DENSITIES LOWER THAN SPECIFIED MINIMUM DENSITIES OR AT MOISTURE CONTENTS OUTSIDE THE SPECIFIED RANGES OR OTHERWISE NOT CONFORMING TO SPECIFIED REQUIREMENTS SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE MATERIALS. 4. ANY FILL LAYER THAT IS SMOOTH DRUM ROLLED TO REDUCE MOISTURE PENETRATION DURING A STORM EVENT SHALL BE PROPERLY SCARIFIED PRIOR TO THE PLACEMENT OF THE NEXT SOIL LIFT. 5. SURFACE WATER AND STREAM FLOW SHALL BE CONTINUOUSLY CONTROLLED THROUGHOUT CONSTRUCTION AND THE PLACEMENT OF CONTROLLED FILL. 6. FOUNDATION AREAS MAY REQUIRE UNDERCUTTING OF COMPRESSIBLE AND/OR UNSUITABLE SOILS IN ADDITION TO THAT INDICATED ON THE PLANS. ALL SUCH UNDERCUTTING SHALL BE PERFORMED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER AND SHALL BE MONITORED AND DOCUMENTED. IN NO CASE SHALL THERE BE AN ATTEMPT TO STABILIZE ANY PORTIONS OF THE FOUNDATION SOILS WITH CRUSHED STONE. 7. TREATMENT OF SEEPAGE AREAS, SUBGRADE PREPARATION, FOUNDATION DEWATERING AND ROCK FOUNDATION PREPARATION (I.E., TREATMENT WITH SLUSH GROUTING, DENTAL CONCRETE, ETC.) MAY BE REQUIRED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER. ALL SUCH ACTIVITIES SHALL BE CLOSELY MONITORED AND DOCUMENTED BY THE GEOTECHNICAL ENGINEER. 8. FILL ADJACENT TO THE RISER AND PRINCIPAL SPILLWAY PIPE SHALL BE PLACED SO THAT LIFTS ARE AT THE SAME LEVEL ON BOTH SIDES OF THE STRUCTURES. 9. EARTHWORK COMPACTION WITHIN 3-FEET OF ANY STRUCTURES SHALL BE ACCOMPLISHED BY MEANS OF HAND TAMPERS, MANUALLY DIRECTED POWER TAMPERS OR PLATE COMPACTORS OR MINIATURE SELF-PROPELLED ROLLERS. 10. COMPACTION BY MEANS OF DROP WEIGHTS FROM A CRANE OR HOIST SHALL NOT BE PERMITTED. 11. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO PASS OVER CAST -IN -PLACE STRUCTURES (INCLUDING THE CRADLE) UNTIL ADEQUATE CURING TIME HAS ELAPSED. 12. TO RE-ESTABLISH VEGETATION AFTER CONSTRUCTION, A 2- TO 3-INCH LAYER OF TOPSOIL SHALL BE PLACED ON THE DISTURBED EMBANKMENT SURFACE AND THE AREA SEEDED AND MULCHED OR HYDROSEEDED. TESTING, OBSERVATION, AND CERTIFICATION 1. TESTS OF THE DEGREE (%) OF COMPACTION OF THE PLACED FILL IN THE DAM SHALL BE PERFORMED AS A PART OF THE PERMITTEE'S NORMAL QUALITY CONTROL PROGRAM FOR THE CONSTRUCTION OF THE DAM. TESTS SHALL BE CONDUCTED CONCURRENT WITH THE INSTALLATION OF THE COMPACTED FILL AND THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF THE DAM SO THAT THE TESTING CAN BE COMPLETED. SHOULD THE RESULTS OF THE TESTS INDICATE THAT THE SPECIFIED DEGREE OF COMPACTION HAS NOT BEEN OBTAINED; THE PORTIONS OF THE DAM REPRESENTED BY SUCH TESTS SHALL BE REWORKED OR REBUILT. ALL PORTIONS OF THE DAM SHALL ACHIEVE THE SPECIFIED MINIMUM DEGREE OF COMPACTION. 2. CONSTRUCTION OF CLASS A, B AND C DAM EMBANKMENTS SHALL BE DONE UNDER THE OBSERVATION OF A QUALIFIED GEOTECHNICAL ENGINEER, WHO IS REGISTERED AS A PROFESSIONAL ENGINEER IN THE STATE OF NORTH CAROLINA. THE GEOTECHNICAL ENGINEER MUST HAVE EXPERIENCE IN THE DESIGN AND CONSTRUCTION MONITORING OF DAMS OF THE SIZE AND SCOPE COVERED BY THESE STANDARDS AND GUIDELINES. 3. ON CLASS A, B, AND C DAMS (WITH THE EXCEPTION OF DETENTION ONLY CLASS C DAMS THAT COLLECT DRAINAGE FROM AN AREA OF 25-ACRES OR LESS), THE GEOTECHNICAL ENGINEER, AS DEFINED ABOVE, SHALL OBSERVE ALL ASPECTS OF THE CONSTRUCTION OF THE DAM (I.E., PREPARATION OF THE FOUNDATION, INSTALLATION OF THE CUT-OFF TRENCH, INSTALLATION OF THE PRINCIPAL SPILLWAY PIPE, INSTALLATION OF THE INTERNAL DRAINAGE, INSTALLATION OF COMPACTED FILL, ETC.). THE FREQUENCY OF OBSERVATION AND TESTING MUST BE SUFFICIENT FOR THE GEOTECHNICAL ENGINEER (OR THE DESIGN ENGINEER ON CLASS D DAMS AND CLASS C, DETENTION ONLY, DAMS) TO STATE, IN HIS/HER PROFESSIONAL OPINION, THAT THE SPECIFIC ITEMS OBSERVED AND TESTED WERE INSTALLED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DRAWINGS AND SPECIFICATIONS. REFERENCE IS MADE TO THE CITY OF DURHAM 'REFERENCE GUIDE FOR DEVELOPMENT" SECTIONS 4.1 TO 4.5 REGARDING GEOTECHNICAL CERTIFICATION OF DAM EMBANKMENTS. OUTLET STRUCTURE SCALE: N.T.S. 30" x 24" LOCKABLE ACCESS HATCH WITH HINGES 4'-10" WELDED ALUMINUM BAR GRATING 3" x 3" OPENINGS PEAKED ROOF TRASH RACK MATERIAL: ALUMINUM WITH 25 N YEAR DESIGN LIFE ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ 3" x 3" OPENINGS O co ° O ° O 1/2" STEEL PLATE co d Od (6) 1/2" X 4" EMBANKMENT STAINLESS STEEL 4 0 a SLOPE BOLTS PER SIDE (TYP). d ° d SOD ELEV.: 425.62 d r 5" MIN. WALL (TYP) EMBANKMENT d ° a d ° ° a 6" UNDERDRAIN INV. ELEV.:421.99 • OUTLET BARREL 18" RCP PIPE INV. BOTTOM OF MEDIA ELEV.: 421.99 ELEVATION = 421.99. 11 11 I I d ° d III II IL IL II II II _ d ° II�I- 11=11 � COMPACTED A ° °d d SUBGRADE ° ° "' ° ° d d ° ° d (SEE SPECS) ° BIO-RETENTION AREA CONSTRUCTION SEQUENCE FOLLOWING FULL STABILIZATION OF THE SITE AND APPROVAL BY NCDENR INSPECTOR AND THE SITE ENGINEER, CONVERT SEDIMENT BASINS AND TRAPS TO FINAL BIO-RETENTION AREAS AS FOLLOWS: 1. ENSURE ENTIRE PERIMETER OF BIO-RETENTION AREA IS STABILIZED WITH A HEALTHY STAND OF VEGETATION. 2. REMOVE ACCUMULATED SEDIMENT AND EXCAVATE TO SUB DRAIN ELEVATIONS, DISPOSE OF EXCAVATED MATERIALS AND SEDIMENT OFF -SITE. 3. FINE GRADE INTERIOR OF DEVICE. 4. REPAIR ANY DAMAGED VEGETATED PERIMETER AREAS WITH SOD OR RE -SEED AND COVER WITH EXCELSIOR SLOPE PROTECTION MATTING. INSTALL SILT FENCE AS NEEDED TO KEEP ANY SEDIMENT FROM DRAINING INTO EXCAVATION. 5. INSTALL SUBDRAIN PIPING WASHED STONE DRAINAGE LAYER AND FILTER FABRIC. DO NOT LEAVE STONE EXPOSED WITHOUT FILTER FABRIC COVER. 6. REMOVE FAIRCLOTH SKIMMER AND PATCH HOLE. 7. PLACE PLANTING SOIL MIX IN DEEP, UNCOMPACTED LIFTS STARTING AT FAR END OF CELL TO AVOID PLACING EARTH MOVING EQUIPMENT ON PLACED SOIL. NO HEAVY EQUIPMENT SHALL BE ALLOWED ONTO THE PLANTING SOIL. 8. INSTALL RIPRAP ENERGY DISSIPATERS WITHOUT PLACING HEAVY EQUIPMENT ON PLANTING SOIL BED. 9. FINE GRADE SURFACE PLANTING SOIL BED BY HAND. 10. INSTALL ALL PLANT MATERIAL BY HAND. 11. REPAIR ALL REMAINING DISTURBED AREAS WITH SOD OR RE -SEED AND COVER WITH SLOPE PROTECTION MATTING. 12. PERFORM GRASS MAINTENANCE UNTIL FULL COVERAGE IS OBTAINED. 13. REMOVE PERIMETER SILT FENCE AND STABILIZE RESULTING DISTURBED AREAS. 14. SILT FENCE BELOW TRAPS AND BASINS SHALL REMAIN IN PLACE UNTIL CONVERSION TO PERMANENT FACILITIES AND FINAL STABILIZATION ARE COMPLETE. SECTION Y-Y PROVIDE AS -BUILT SURVEY, REQUIREMENTS ARE LISTED BELOW: CONTRACTOR SHALL PROVIDE SIGNED, SEALED AND DATED AS -BUILT SURVEY PLANS PERFORMED BY A PROFESSIONAL LAND SURVEYOR THAT INCLUDES THE FOLLOWING: • BIO-RETENTION AREA DIMENSIONS • AREA OF BERMUDA SOD • ELEVATIONS • SIDE SLOPES • BENCHMARK FOR CLEANOUT • INLET DEVICES AND ENERGY DISSIPATERS • OUTLET STRUCTURE INVERTS • ORIFICE DIAMETER • PIPE SIZES • CLEANOUT LOCATIONS AND ELEVATIONS • PLAN AND CROSS-SECTION VIEW AT A SCALE OF 1"=30' OR LARGER • CROSS SECTION • TOPOGRAPHY SHALL EXTENDED TO 20 FEET OUTSIDE LIMITS OF BIO-RETENTION AREA. CONTRACTOR SHALL PROVIDE SPECIFICATION SHEETS FOR MATERIALS USED IN THE SCM SUCH AS PLANTING MEDIA, FILTER MEDIA AND AGGREGATE. PROTECT PLANTING SOIL WITH PERIMETER SILT FENCE AND A TEMPORARY COVER OF NON -WOVEN DRAINAGE (FILTER) FABRIC UNTIL COMPLETE SITE STABILIZATION IS ACHIEVED. REMOVE SILT FENCE AND DRAINAGE FABRIC AND INSTALL MULCH AND PLANT MATERIAL ONCE SITE IS COMPLETELY STABILIZED WITH PERMANENT GROUND COVER. BIORETENTION STORMWATER CONTROL MEASURE (SCM) OUTLET - aii TO SURFACE MIN. 12" UPTURNED ELBOW = (424.00) FOR INTERNAL WATER STORAGELAYER INV ELEV: 421.99 0 VALVE INV.: 425.62 4'-0" 0 - RIM ELEV= 427.22 -12" SHALLOW PONDING "' -"'-"'-"' "' "' CONVERT TO 6" SOLID WALL 2 LF 12" UPTURNED ELBOW PVC PIPE PRIOR TO ENTERING FOR IWS THE OUTLET STRUCTURE (TYP.) SHWT ELEV= 420.00' o BIORETENTION SECTION N.T.S. 8-FT WEIR WIDTH 3 3 �1 1� SPILLWAY CREST ELEV: 428.00 EMERGENCY SPILLWAY SECTION SCALE: N.T.S. WELDED ALUMINUM BAR GRATING 3" x 3" OPENINGS PEAKED ROOF TRASH RACK A: MATERIAL: ALUMINUM WITH 25 / YEAR DESIGN LIFE ° 4'-0" ° STAINLESS STEEL BOLTS (TYP). d °° SOD ELEV.: 425.6 d dO dd ° ° ° d d d ° d d d 5" MIN. WALL (TYP) nBARREL ° d OUTLET BARREL ADDITIONAL CLASS B CONCRETE IN BOTTOM OF STUCTURE d ° 9 Ln d SECTION Z-Z BIORETENTION AREA MAINTENANCE SCHEDULE DESCRIPTION METHOD FREQUENCY SEASON SOIL INSPECT AND REPAIR VISUAL MONTHLY ALL EROSION GRASS REPLACE ANY DEAD OR SEE PLANTING TWICE PER YEAR MAR 15 - APR 30 DISEASED VEGETATION SPECIFICATIONS OCT 1 - NOV 30 CONSIDERED BEYOND TREATMENT TREAT ALL DISEASED MECHANICAL WHENEVER NEEDED ALL PLANTS NOT TO BE REMOVED OR BY HAND WATER PLANT MATERIAL BY HAND IMMEDIATELY AFTER N/A AND END OF EACH DAY COMPLETION OF FOR 14 CONSECUTIVE PROJECT DAYS AFTER PLANTING MOW GRASS ONCE ESTABLISHED AS MECHANICAL MONTHLY ALL NECESSARY TO MAINTAIN PLANT HEALTH CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE UNTIL SUBSTANTIAL COMPLETION AT WHICH TIME OWNER WILL ASSUME MAINTENANCE RESPONSIBILITY. LANDSCAPE WARRANTIES SHALL APPLY TO BIORETENTION AREA PLANTINGS. - SOD WITH CELEBRATION BERMUDA 30-IN PLANTING SOIL BED PLACE IN 10" LIFTS LOOSELY COMPACTED ��tllllllff// Q - L = 033612 / 51122 FNGINEE�y\N;����` •,��NL+'S S i 'NS�,���. RECORD DRAWING THIS DOCUMENT DEPICTS THE ORIGINAL 3-IN WASHED SAND DESIGN REVISED TO INCLUDE NON -WOVEN FILTER FABRIC CONSTRUCTION PHASE REVISIONS AND 9-IN #57 WASHED STONE AS -BUILT INFORMATION FURNISHED (4-IN MIN. ON TOP AND SIDES) IN -PART BY OTHERS. WHILE THE AS -BUILT INFORMATION IS BELIEVED TO BE RELIABLE, THE SUB -DRAIN 6" SCH 40 PVC DESIGNER CANNOT ASSURE ITS PERFORATED PIPE ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS DOCUMENT OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. 12-IN THICK CLASS B RIPRAP OVER FILTER FABRIC OUTLET STRUCTURE NOTES: 1. OUTLET STRUCTURE TO BE PRE -CAST OR CAST IN PLACE. 2. CLASS "A" (3,000 PSI) CONCRETE TO BE USED. 3. FORMS ARE TO BE USED FOR THE CONSTRUCTION OF THE BOTTOM SLAB. 4. ALL STRUCTURES OVER T-6" IN DEPTH TO BE PROVIDED WITH STEPS V-2" ON CENTERS. STEPS SHALL BE IN ACCORDANCE WITH STANDARD 840.66. 5. ALL PENETRATIONS TO BE WATERPROOF SEALED WITH NON -SHRINK, HIGH -STRENGTH GROUT. PLANTING SOIL BED MIXTURE pH RANGE 5.2 TO 7.00 P-INDEX 10-30 SOLUBLE SALTS 500 PPM MAXIMUM FINES (SILT AND CLAY) 9% (ACCEPTABLE RANGE: 8-15%) SAND 82% (ACCEPTABLE RANGE: 75-85%) ORGANIC MATERIAL (PINE BARK FINES) 9% (ACCEPTABLE RANGE: 5-10%) PERMEABILITY 1"/HOUR MIN, 6"/HOUR MAX. 1-2"/HOUR PREFERRED NOTES: - PLANTING MEDIA FOR BIO-RETENTION SHOULD BE UNIFORM FREE OF STONES, STUMPS, ROOTS OR OTHER SIMILAR MATERIAL GREATER THAN 2 INCHES AND MEET THE SPECIFICATION NOTED ABOVE. - SM, ML, SC SOIL CLASSIFICATIONS (USCS) - POSSIBLE SOURCE OF PLANTING SOIL BED MIXTURE: TRIANGLE LANDSCAPE SUPPLIES - PROTECT PLANTING SOIL WITH PERIMETER SILT FENCE AND INSTALL SOD ON SIDE SLOPES. - REMOVE SILT FENCE AND DRAINAGE FABRIC ONCE SITE IS STABILIZED WITH PERMANENT GROUND COVER. - INSTALL PLANT BED SOIL ONCE THE SITE IS STABILIZED AND THE BIO-RETENTION AREA IS NO LONGER UTILIZED AS A TEMPORARY SEDIMENT BASIN. - PLACE IN 12-18" LOOSE LIFTS, LOOSELY COMPACTED WITH BACKHOE BUCKET. - PEFORATED SUB -DRAIN PIPES SHALL HAVE A MINIMUM OF 4 ROWS OF STAGGERD PERFORATIONS EQUIDISTANT AROUND THE PERIMETER OF THE PIPE, PERFORATIONS IN EACH ROW SHALL BE SPACED 6-IN O.C. PERFORATION SHALL BE 3/8" DIAMETER. N.T.S. E 0 V C tp 0 ui N E 9 LuU Z Lu dLL NOD W C M W �_'ia0 �J�x M 1 Z O � -4 > c L ko oOR o L� J W H- DATE 21 ]AN 2022 DRAWN BY • WA • DESIGNED BY • FS • CHECKED BY • • FS SCALE • NTS 0 • <Q um ,, 1� CD J M TW � (I � LU Lu J u O V / U JJ ICY CD l0 Lu LL r� N 0 N z dS � o (n '-' Lu U Q U o = O (D ~ z Lu V 0 z J z z Lu < 0 J z Lu 0 az z Lu J O o Q o w N uzwp Q Ln 00 z 0O L z '-' >_ J � O LL < H Q U-) U 0 J 0 110 LL � O � z JOB NO. 42866 SHEET NO. C5.7 0 L_