Loading...
HomeMy WebLinkAboutWQ0023261_Inspection_20220428DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Compliance Inspection Report Permit: WQ0023261 Effective: 10/01/20 SOC: Effective: County: Onslow Region: Wilmington Contact Person: Edward M Caron Expiration: 10/31/26 Expiration: Title: Owner : Onslow Water and Sewer Authority Facility: Swansboro WWTP 199 Williams Rd Swansboro NC 28584 Phone: 910-937-7523 Directions to Facility: Approximately 0.25 miles southeast of the intersection of SR 1511 and SR 1512 at the Town of Swansboro WWTP site and also northeast of the intersection of SR 1432 adn SR 1744 System Classifications: WW3., Primary ORC: Mark Curtis Young Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 04/28/2022 Primary Inspector: Geoff Kegley Secondary Inspector(s): Entry Time 10:30AM DocuSigned by: G'aa# "-CD17E2515D3B417... Reason for Inspection: Routine Permit Inspection Type: High Rate Infiltration Facility Status: Compliant ❑ Not Compliant Question Areas: ▪ Treatment Flow Measurement -Effluent ▪ Treatment Flow Measurement -Water Use Records ▪ Treatment Filters ▪ Treatment Sludge Storage/Treatment ▪ End Use -Infiltration ▪ Standby Power (See attachment summary) Certification: 1001105 Exit Time: 12:30PM Phone: 910-937-7570 Phone: Inspection Type: Compliance Evaluation ▪ Treatment Flow Measurement -Influent ▪ Treatment ▪ Record Keeping ▪ Treatment Clarifiers ▪ Treatment Flow Measurement ▪ Wells ▪ Miscellaneous Questions ▪ Treatment Barscreen ▪ Treatment Activated Sludge ▪ Treatment Disinfection ▪ Treatment Return pumps Page 1 of 7 DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Permit: WQ0023261 Owner - Facility: Onslow Water and Sewer Authority Inspection Date: 04/28/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection was conducted at the Swansboro WWTF and disposal site on April 28, 2022. The evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0023261. The primary ORC, Mark Young, was present during the inspection and was very helpful providing assistance throughout the inspection. The facility consists of: • 123,00 gallon EQ basin • Mechanical cylindrical screen with screw conveyor, vortex grit chamber and manual bar screen • Two 300,00 gallon oxidation ditches • Two 22' clarifiers and one 32' clarifier • Dual rotating cloth disk filters • UV disinfection • 4.28 MG 5-day upset pond • Sludge digester and sludge holding tank (and currently unused sand filter drying beds) • Disposal via four high -rate infiltration basins located off site According to the monitoring reports, the plant has been treating an average of approximately 350,000gpd for the months of January and February 2022, the permitted flow is 600,000gpd. Only one oxidation ditch was in operation at the time of inspection and is handling all the current flows appropriately. The Operation and Maintenance logs, sampling data and records are very well organized. Two NOVs were issued in March and April 2021 for fecal and TSS which occurred during an upset event, otherwise monitoring records generally show consistent compliance with permit limits. The freeboard in the 5-day upset pond was compliant at the time of inspection, but the level was fairly high due to another upset event which appears to be under control at this time. These springtime upset events could possibly be somewhat correlated with seasonal temperature swings. The facility is deemed compliant with the non -discharge permit WQ0023261. Page 2 of 7 DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Permit: WQ0023261 Owner - Facility: Onslow Water and Sewer Authority Inspection Date: 04/28/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Tvpe Reuse (Quality) Lagoon Spray, LR Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Activated Sludge Drip, LR Recycle/Reuse Single Family Drip Infiltration System Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Comment: Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: The flowmeter was calibrated on October 27, 2021 by Carolina Technical Services. Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: The flowmeter was calibrated on October 27, 2021 by Carolina Technical Services. Standby Power Is automatically activated standby power available? Yes No NA NE • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ • ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ II ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ Page 3 of 7 DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Permit: WQ0023261 Owner - Facility: Onslow Water and Sewer Authority Inspection Date: 04/28/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The generator is tested under load every Monday and runs for approximately 1 hour each test. Results are recorded in the maintenance log, along with generator fuel capacity. The generator was tested and run during the inspection. Treatment Barscreen Is it free of excessive debris? Is disposal of screenings in compliance? Are the bars spaced properly? Is the unit in good condition? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: This process involves mechanical screen with a screw conveyor and a vortex grit chamber. There is a bypass channel with a manual barscreen available in times of need. Treatment Activated Sludge Is the aeration mechanism operable? Is the aeration basin thoroughly mixed? Is the aeration equipment easily accessed? Is Dissolved Oxygen adequate? Are Settleometer results acceptable? Is activated sludge an acceptable color? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: This process involves the use of variable frequency drives to control the rotor brushes and DO levels inside of the two 300,000 gallon oxidation ditches, with a sluice gate connecting the two. Oxidation ditch #1 is only used in peak -flow events. Treatment Clarifiers Are the weirs level? Are the weirs free of solids and algae? Is the scum removal system operational? Is the scum removal system accessible? Is the sludge blanket at an acceptable level? Is the effluent from the clarifier free of excessive solids? Comment: Treatment Return pumps Are they in place? Are they operational? Comment: Treatment Filters Is the filter media present? Yes No NA NE • ❑ ❑ ❑ • ▪ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ Page4of7 DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Permit: WO0023261 Owner - Facility: Onslow Water and Sewer Authority Inspection Date: 04/28/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the filter media the correct size and type? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids? Is the mud well free of excessive solids and filter media? Does backwashing frequency appear adequate? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: This process consists of two, dual rotating cloth disk filters with a timed/high-level automatic backwash. These basins are cleaned using bleach when needed to help control algae growth. The high water alarm in one of these units was tested during the inspection. Treatment Sludge Storage/Treatment Is the aeration operational? Is the aeration pattern even? If required, are Sanitary "Ts" present in tankage? Comment: Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? Yes No NA NE ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑• Yes No NA NE • ❑ ❑ ❑ ▪ ❑ ❑ ❑ Page5of7 DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Permit: WQ0023261 Owner - Facility: Onslow Water and Sewer Authority Inspection Date: 04/28/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? No treatment units bypassed since last inspection? Comment: End Use -Infiltration # Is the application High Rate or Low Rate? Are buffers maintained? Are any supply wells within the CB? Are any supply wells within 250' of the CB? Is municipal water available in the area? Are GW monitoring wells required? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Is a usable green area maintained? Is the disposal site acceptable? Is the distribution equipment acceptable? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑•❑ ❑ ❑•❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ • Yes No NA NE High Rate • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page6of7 DocuSign Envelope ID: A6D58F3E-2F48-4B54-B254-51D53B24F357 Permit: WO0023261 Owner - Facility: Onslow Water and Sewer Authority Inspection Date: 04/28/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the disposal site free of ponding? • ❑ ❑ ❑ Is the disposal site free of breakout? • ❑ ❑ ❑ Are the disposal sites free of solids, algae, etc.? • ❑ ❑ ❑ Do the records show that the fields are properly maintained? • ❑ ❑ ❑ Are the disposal sites free of vegetation? • ❑ ❑ ❑ Do any surface water features appear to be adversely impacted by GW discharge? ❑ • ❑ ❑ No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? • ❑ ❑ ❑ Comment: There have been inconsistent minor groundwater exceedance of pH and Nitrate. The WWTF is not designed to denitrify. Infiltration ponds, berms, mowing, monitoring wells and general housekeeping were in great condition. Page 7 of 7