Loading...
HomeMy WebLinkAboutNCG080881_2021 DMR_20220307James E. Shepard March 7, 2022 NC DEQ Raleigh Regional Office Division of Water Resources (DWR) 3800 Barrett Drive Raleigh, North Carolina 27609 To Whom It May Concern: Utilities Services and Operations Please find enclosed the Quarterly Discharge Monitoring Report for North Carolina Central University - Durham, North Carolina. This report was mailed out on January 11, 2022, but it still does not show that it has been uploaded into the system. I am sending a second copy to ensure that you have it. Sincerely, Harold L. Seegars Interim Assistant Director of Utilities and Facilities Operations. NORTH CAROLINA CENTRAL UNIVERSITY • P.O. BOX 19735 • DURHAM, NC 27707 • (919) 530-6392 • FAX (919) 530-7884 NORTH CAROLINA CENTRAL UNIVERSITY IS A CONSTITOENT I\ STITUFTIOAT OF THE U WERSITY OF NORTH CAROLINA NCDEQ Division of Energy, Mineral and Land Resources Storrnwater Discharge Monitoring Report (DMR) Form for NCGO80000 Transit and Transportation Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. This DMR form is only applicable to stormwater discharges from the following areas that have been specifically designated by the Division as subject to the requirements of Part F-1 and brought under NCG080000: (1) oil water separators (2) containment structures at petroleum bulk stations and terminals with a total petroleum storage capacity of less than 1 million gallons (3) other stormwater discharges specifically designated. For stormwater discharges associated with vehicle maintenance areas at categorically captured facilities under NCG080000, please use the standard NCGO80000 DMR form. Certificate of Coverage No. NCGO80881 Person Collecting Samples: Lindsay Fletcher Facility Name: NCCU Physical Plant Laboratory Name: Waypoint Analytical Facility County: Durham Laboratory Cert. No.: 415 Discharge during this period:: Yes E] No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? 0 Yes ID No If so, which Ter (I, II, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg nc.gov/Forms/SW DMR Yes No Date Uploaded: Analytical Monitoring Requirements for Oil/Water Separators and Secondary Containments Areas at Bulk Stations & Terminals (Those Designated and Brought Under NCG080000) — Effluent Limits in (Red) Parameter Code Parameter Outfall001 outfall Outfall Outfall Outfall N/A Receiving Stream Class WS-V, NSW N/A Date Sample Collected MM/DD/YYYY 12/08/2021 46529 24-Hour Rainfall in inches 0.3 C0530 TSS in mg/L (100 or 50*) 18.6 00552 Non -Polar Oil & Grease in mg/L (15) <1 .7 00400 pH in standard units (6.0 — 9.0 FW, 6.8 — 8.5) 7.0 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of taw, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee or Delegafed Authorized Individual p14 Email Address I r! -/ V Date Phone Number ►h Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visithttps://deq.ne.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gp s Permit No.: N/C/G/0/8/0/0/0/0/ or Certificate of Coverage No.: N/C/G/0/8/0/8/8/1/ Facility Name: NCCU County: Durham Phone No. 919-530-6392 Inspector: Lindsay Fletcher Date of Inspection: 12/08/2021 Time of Inspection: 0855 Total Event Precipitation (inches): 0.3 ------------------------------------------------- ---------------------------------------------------------------------------- All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site P outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR i Regional Office. ---------------------------------------------------------------------------------------------------------------------------------------------- By this signature, I certify that this report is accurate and complcte to the best of myknowledge: (Signature of Permittee or 1. Outfall Description: Outfall No. 001 Structure (pipe, ditch, etc.): Concrete culvert Receiving Stream: Discharge flows into unnamed tributary to Third Fork Creek Describe the industrial activities that occur within the outfall drainage area: Oil -Water Separator Pagel of 2 SwU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors. clear light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: © 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: (D 2 3 4 5 G. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 01 2 3 4 5 7. Is there any foam in the stormwater discharge? C7, Yes a No. 8. Is there an oil sheen in the stormwater discharge? Q Yes o No. No 9. Is there evidence of erosion or deposition at the outfall? ,o Yes 0 No. No 10. Other Obvious Indicators of Stormwater Pollution: List and describe None Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 6 Waypoin-L..demb ANALYTICAL 12/15/2021 Kleinfelder SE, Inc. (Morrisville) Lindsay Fletcher 3200 Gateway Centre Blvd. Suite 100 Morrisville, NC, 27560 Ref: Analytical Testing Lab Report Number: 21-343-0001 Client Project Description: NCCV Dear Lindsay Fletcher: 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypoiiitanalytical.com Waypoint Analytical, LLC (Charlotte) received sample(s) on 12/9/2021 for the analyses presented in the following report. The above referenced project has been analyzed per your instructions. The analyses were performed in accordance with the applicable analytical method. The analytical data has been validated using standard quality control measures performed as required by the analytical method. Quality Assurance, method validations, instrumentation maintenance and calibration for all parameters were performed in accordance with guidelines established by the USEPA (including 40 CFR 136 Method Update Rule May 2021) unless otherwise indicated. Certain parameters (chlorine, pH, dissolved oxygen, sulfite...) are required to be analyzed within 15 minutes of sampling. Usually, but not always, any field parameter analyzed at the laboratory is outside of this holding time. Refer to sample analysis time for confirmation of holding time compliance. The results are shown on the attached Report of Analysis(s). Results for solid matrices are reported on an as - received basis unless otherwise indicated. This report shall not be reproduced except in full and relates only to the samples included in this report. Please do not hesitate to contact me or client services if you have any questions or need additional information. Sincerely, Angela D Overcash Senior Project Manager Laboratory's liability in any claim relating to analyses performed shall be limited to, at laboratory's option, repeating the analysis in question at laboratory's expense, or the refund of the charges paid for performance of said analysis. Waypointo ANALYTICAL 449 $pringbrook Rd, Charlotte, NC 28717 Main 704.529.6364 www.waypointanalyt[cal.com Certification Summary Laboratory ID: WP CNC: Waypoint Analytical Carolina, Inc. (C), Charlotte, NC State Program Lake ID Expiration Date North Carolina State Program 37735 07/31/2022 North Carolina State Program 402 12/31/2021 South Carolina State Program 99012 07/31/2022 South Carolina State Program 99012 12/31/2021 Page 1 of 1 00016/21-343-0001 (2) Wa YPOI*nt, ANALYTICAL Report Number: 21-343-0001 Client Project Description: NCCV Lab No Client Sample ID 449 5pringbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytiral.com Sample Summary Table Matrix Date Collected Date Received 90172 5D0-1 Aqueous 12/08/2021 08:55 12/09/2021 11:00 i Wa I n� 449 5pringbrool< Rd, Charlotte, 28217 Main 70G.5.529.Ii364 G4 YPO ANALYTICAL www.waypointanalytical.com Summary of Detected Analytes Project- NCCV Report Number: 21-343-0001 Client Sample ID Lab Sample ID Method Parameters Result Units Report Limit Analyzed Qualifiers SDO-1 V 90172 2540D-2015 Total Suspended Solids 16.6 rng/L 4500H+B-2011 pH 7.00 s.u. 23 12/13/2021 1020 12/09/2021 12:50 wavDoint.o ANALYTICAL 01123 Kleinfelder SE, Inc. (Morrisville) Lindsay Fletcher 3200 Gateway Centre Blvd. Suite 100 Morrisville , NC 27560 Project NCCV Information : 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Report Date : 12/15/2021 Received : 12/09/2021 Report Number : 21-343-0001 REPORT OFANALYSIS Lab No : 90172 Matrix: Aqueous Sample ID: SDO-1 Sampled: 12/8/2021 8:55 Test Results Units MDL MQL DF Date 1 Time By Analytical Analyzed Method SGT HEM: Non -Polar Material <1.7 mg/L 1.7 5.7 1 12/14/21 10:22 CEG 1664E-SGT pH 7.00 SM. 1 12/09/2112:50 CLB 4500H+B-2011 Total Suspended Solids 18.6 mg/L 2.3 8.3 1 12/13/21 10:20 SLO 2540D-2015 QualiFers/ DF Dilution Factor L Limit Exceeded Definitions MQL Method Quantitation Limit Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: Project Description: Report No: Kleinfelder SE, Inc. (Morrisville) NCCV 21-343-0001 QC Analytical Batch: V12784 Analysis Method: 1664B-SGT Analysis Description: Oil and Grease - TPH Lab Reagent Blank LRB Matrix: AQU Associated Lab Samples: 90172 Blank MDL MQL Analyzed Parameter Units Result SGT HEM: Non -Polar Material mg/L <1,5 1.5 5A 12/14/21 10:22 Ongoing Precision and Recovery OPR Spike OPR a/o Analyzed %Rec Qualifie Parameter Units Conc. Result Recovery Limits SGT HEM: Non -Polar Material mg/L 20.0 17.4 87.0 12/14/21 10:22 64-132 Date: 12/15/2021 11:02 AM Page i of 3 0 Waypoint 449 Springbrppk Rd, Charlptte, NC 28217 w Main 704.529.6364 ANALYTICAL www.waypointanalytical.com Quality Control Data Client ID: Kleinfelder SE, Inc. (Morrisville) Project Description: NCCV Report No: 21-343-0001 QC Analytical Batch: V12771 Analysis Method: 2540D-2015 Analysis Description: Total Suspended Solids Lab Reagent Blank LRB Matrix: AQU Associated Lab Samples: 90172 Blank MDL MQL Analyzed Parameter Units Result Total Suspended Solids mg/L <0.7 0.7 2.5 12/13/21 10:20 Laboratory Control Sample LCS Spike LCS LCS %Rec % Rec Parameter Units Conc. Result Limits Total Suspended Solids mg/L 477 437 92.0 90-110 Duplicate V 90157-DUP Result DUP RPD Max RPD Analyzed Parameter Units Result Total Suspended Solids mg/1_ 61.4 65.7 6.7 10.0 12/13/21 10:20 Date: 12/15/2021 11:02 AM Page 2 of 3 0 Waypoint 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytiral.com Quality Control Data Client ID: Kleinfelder SE, Inc. (Morrisville) Project Description: NCCV Report No: 21-343-0001 QC Analytical Batch: V12643 Analysis Method: 4500H+B-2011 Analysis Description: pH Laboratory Control Sample LCS Spike LCS LCS %Rec % Rec Parameter Units Conc. Result Limits pH s.U. 6.86 6.86 100 3.54-101.z Laboratory Control Sample LC521 Spike LCS LCS %Rec % Rec Parameter Units Conc. Result Limits pH S.U. 6.86 6.84 100 3.54-101,,� Duplicate V 90215-DUP Result DUP Criteria Analyzed Parameter Units Result pH S.U. 7.04 7.05 +/- 0.1 12/09/21 12:50 Date: 12/15/2021 11:02 AM Page 3 of 3 Q) WayPAo nt .. NALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Shipment Receipt Form Customer Number. 01123 Customer Name: Kleinfelder SE, Inc. (Morrisville) Report Number: 21-343-0001 Shipping Method Fed Ex US Postal ;Lab Other UPS Client Courier Thermometer ID: IRT-15 -0.5C Shipping container/cooler uncompromised? Yes t, ' No Number of coolers/boxes received 1 Custody seals intact on shipping container/cooler? l! Yes No ;_ Not Present Custody seals intact on sample bottles? Yes _ ` No Not Present Chain of Custody (COC) present? Yes C No COC agrees with sample label(s)? Yes C) No COC properly completed Yes C) No Samples in proper containers?; Yes No Sample containers intact? Yes " ; No Sufficient sample volume for indicated test(s)? '! Yes l; No All samples received within holding time? Yes ;) No Cooler temperature in compliance? (_) Yes No Cooler/Samples arrived at the laboratory on ice. ;,; Yes ; ,j No Samples were considered acceptable as cooling process had begun. Water - Sample containers properly preserved (0. Yes 0 No NIA Water - VOA vials free of headspace ; Yes 0 No J*; NIA Trip Blanks received with VOAs .) Yes 0 No ; NIA Soil VOA method 5035 —compliance criteria met Yes _ No J NIA High concentration container (48 hr) Low concentration EnCore samplers (48 hr) High concentration pre -weighed (methanol -14 d) Low conc pre -weighed vials (Sod Bis -14 d) Special precautions or instructions included? _j Yes No Comments: The samples were -0.5C, when they should be between OC and 6C. As a result the samples were partially frozen. Signature: 1,Sarah J. Locklear Date & Time: 12/09/2021 11:27:4� jLL �L 9 I3 nm' Ly" SL m R 0 y c m •c °'' � a Ci] a- cL;ZN� a o -4 L g ,dSi m c3 m' 9 .. L L M m 00L � o° L m� �c A.i^. i n cu a "I y D N i m or n�•c a m Mc n�L of rn C � W i c Q y rig g z W Z n 6' i n 2 3 ! o L n m w ID c) �9 a 1 m m 5 m o by M v �A LCzn ' 0 �I W. 7 L 0 Z T f r) Er x to m ,Z m l Rai Z z Lr y W W ya _f Z Z 0 ❑ Lw i n �Lo u nm 0 S r L p O C u N n 3 g n 0 m N ......... ......... ........... cn ....... G) zi z r L--- ---............... ....... a v C• m i yr N m n� z N C7 M. rn h 0 = 3 O 0=tm� �Dnm /tJ1 q CN ►w m o rr 'o n m n -0zgm �rN N CL a I n �n O 0 � p 3 m 3 0 .n ti y -1, 7 y m N rnT >m�a� W off.;mw;°or mvmt�w m p. In 9.._ m N z <A,b v m — a (L 0ri r 4 m a C m n6U,8 a ra° a L' {m_F N r c O _O n O � L c$i 7� F L \\` �� n N'CV N wa CL v d N N m, m t0 04Dx N C N p m lu m ,CL m m € x� U p a y � y o 0 luv m m Z. ff W �i C m � m o 3 � Aa � a F � n r-:.C- AD Paae 10,,of io NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCGO80000 Transit and Transportation Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upfoad form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. This DMR form is only applicable to Stormwater discharges from the following areas that have been specifically designated by the Division as subject to the requirements of Part F-1 and brought under NCG080000: (1) oil water separators (2) containment structures at petroleum bulk stations and terminals with a total petroleum storage capacity of less than 1 million gallons (3) other stormwater discharges specifically designated. For stormwater discharges associated with vehicle maintenance areas at categorically captured facilities under NCGO80000, please use the standard NCGO80000 DMR form. Certificate of Coverage No. NCG080881 Person Collecting Samples: Lindsay Fletcher Facility Name: NccU Physical Punt Laboratory Name: Waypoint Analytical Facility County: Durham Laboratory Cert. No.: 415 Discharge during this period:E] Yes 0 No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?Ej Yes QNo If so, which Tier (1, 11, or 111)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR 0 Yes 0 No Date Uploaded: Analytical Monitoring Requirements for Oil/Water Separators and Secondary Containments Areas at Bulk Stations & Terminals (Those Designated and Brought Under NCG080000) — Effluent Limits in (Red) Parameter Code Parameter Outfall floc Outfall C#utfall Outfall Outfall N/A Receiving Stream Class WS-V, NSW N/A Date Sample Collected MM/DD/YYYY 12/08/2021 46529 24-Hour Rainfall in inches 0.3 C0530 TSS in mg/L (100 or 50*) 18.6 00552 Non -Polar Oil & Grease in mg/L (15) <1.7 00400 pH in standard units (6.0 — 9.0 FW, 6.8 — 8.5) 7.0 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 5o mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." / - zy - 7-'2. Signature of Permittee or Delegated Authorized Individual Date Email Address Phone Number