HomeMy WebLinkAboutWI0700323_Injection Inspection Repot_20220429North Carolina Department of Environment and Natural Resources Division of Water Quality — Aquifer Protection Section INJECTION FACILITY INSPECTION REPORT PERMIT NO. WI0700323 DATE OF INSPECTION: 4/27/22 INSPECTOR: R. Sipe w/ WQROS-WaRO NAME OF PERMITTEE(S) Jonathon & Melynda Oliver MAILING ADDRESS OF PERMITTEE 1409 Potomac Dr., Chocowinity, NC 27817 PHYSICAL ADDRESS OF SITE (if different than above) same as above PERSON MET WITH ON -SITE Jonathon Oliver ; TELE NO. (936) 200-3696 WELL(S) STATUS: XExisting and operating Class V Well Existing well proposed to be converted to Class V well Proposed/not constructed LAT/LONG OF WELL(S) 35.492293N, 77.047070W Appx. distance of well to property boundaries: —30 feet Appx. distance of well from foundation of house/structure: —60 feet Appx. distance of well from septic tank/field (if present): No Septic system onsite. Area served by municipal WWTP. Appx. distance of well to other well(s) (if present): —60 feet to supply well Appx. distance to other sources of pollution: _None known Flooding Potential of Site: high moderate X low Comments: _The conditions observed during the site visit were consistent with the last visit. Based on observations of the wells during the site visit, it appears both the wells are in good condition and operating adequately. Injection Facility Insp. Report (Rev. Sept 2009) Page 1 of 3 Pages See Attached Map DRAW SKETCH OF SITE ABOVE (Show property boundaries, buildings, other wells, septic tanks/drain fields, other potential pollution sources, roads, approximate scale, and NORTH arrow) See attached GW-1 form Draw Schematic of well above showing TD, casing depth, grout, etc. Injection Facility Insp. Report (Rev. Sept 2009) Page 2 of 3 Pages Well Construction Information Date Constructed: 10/15/15 Well Contracting Company: Magette Well & Pump Co. Well Driller Name: Bill Magette NC Well Cert. No.: 2299 — A Address: 2342 US 13, Ahoskie, NC 27910 Telephone No.: (252)332-2265 ; Cell No.: Email Address: Proposed Depth of Well(s): 160 feet Total Depth: 160 Total Depth of Source Well, if present: 160 Casing: Depth: 140 feet ; Diameter: 4 inch ; Type (gay. steel, PVC, etc.): PVC Stick Up: 1.0 ft Grout: Depth: 120 feet ; Type (cement, bentonite, etc.):Bentonite_ Placement (pumping, press. etc.): tremie Well ID Plate Present (Y or N): Y_; Heat Pump ID plate present (Y or N): N/A Influent spigot (Y or N): Y ; Effluent spigot (Y or N): Y Well Sampled? (Y or N): Y ; If Yes, Lab Sample ID numbers: Influent (Supply) Effluent (Injection) Static Water Level: Not Meas. 26 feet BLS reported on GW-1 Injection Information (if applicable): Injection Rate: NM GPM Injection Pressure: NM PSI Injection Volume: NM GPD Temperature- Summer: NM F° Temperature- Winter: NM F° Comments/Notes The wells appeared to be in good condition and Mr. Oliver stated that the system had been working well since he purchased the property. Samples were collected from the supply well (Influent) and injection well (Effluent) and lab reports for the sampling event will be provided to the Central Office and Mr. Oliver when they are received by WaRO. Injection Facility Insp. Report (Rev. Sept 2009) Page 3 of 3 Pages