20202013 Ver 1_NOV-2022-PC-0079 Response (Restoration Plan)_20220408
BRIDGEWATER LANDING RESTORATION PLAN Edens Lane Hampstead, NC Pender County Prepared By: DAVEY Resource Group Prepared For: Edens Lane, LLC Action ID# SAW-2021-00135 DWR Project No. 20202013 APRIL 2022 TABLE OF CONTENTS 1.0 INTRODUCTION 1 2.0 SITE HISTORY 1 3.0 EXISTING CONDITIONS 2 4.0 CROSSING INFORMATION 2 4.1 Crossing #1 2 4.2 Crossing #2 3 4.3 Crossing #3 3 5.0 PROPOSED STREAM RESTORATION METHODS 4 6.0 PROPOSED MONITORING 4 LIST OF FIGURES & APPENDICES Figure 1. Vicinity Map Figure 2. USGS Topographic Map Figure 3. Aerial Photograph Figure 4. USACE-Approved Wetland Map Figure 5. Wetland Map Showing Approximate Location of 5 Crossings Figure 6. Crossing #1: Existing Conditions Figure 7. Crossing #1: Proposed Conditions Figure 8. Crossing #2: Existing Conditions Figure 9. Crossing #2: Proposed Conditions Figure 10. Crossing #3: Existing Conditions Figure 11. Crossing #3: Proposed Conditions Appendix A. Site Photos Appendix B. Site Plan Drawings Appendix C. Retaining Wall Plans BRIDGEWATER LANDING RESTORATION PLAN PENDER COUNTY, NC Action ID# SAW-2021-00135 DWR Project No. 20202013 APRIL 2022 1.0 Introduction In order to mitigate for unauthorized impacts to approximately 290 linear feet of streams and 0.181 acres of 404 wetlands within the Bridgewater Landing Subdivision, Edens Lane, LLC proposes to restore 76 LF of stream and 0.014 acres of wetlands and obtain after -the -fact Section 404/401 permits for 214 LF of stream and 0.201 acres of wetland impact. Additionally, the applicant will purchase 428 LF of stream and 0.4 acre of wetland mitigation credits from the Northeast Cape Fear Umbrella Mitigation Bank or NC Division of Mitigation Services (dependent upon credit availability). This site consists of 86 acres and is located off Edens Lane in Hampstead, NC (Pender County) (Figures 1-3). 2.0 Site History A Sedimentation and Erosion Control Permit was obtained for the project in 2021. The site plan attached to this plan was an outdated version that included five stream/wetland crossings. The developer has assumed that Section 404/401 permits had also been secured and contractors installed the five road crossings that impacted streams and/or wetlands. It was discovered that permits had not been obtained and Davey Resource Group, Inc. (DRG) submitted a Section 404/401 permit application for the project on December 1, 2021. A site inspection conducted by NC Division of Water Resources staff determined that the project had impacted wetlands and streams without a permit and that the installed configuration did not match the site plan submitted with the application. A Notice of Violation was issued to Edens Lane, LLC on March 9, 2022 (NOV-2022-PC-0079). Additionally, the 401 Water Quality Certification application was denied (DWR Project # 20202013). 3.0 Existing Conditions The site consists of 86 acres and is located off Edens Lane in Hampstead, NC (Pender County) (Figures 1-3). Several streams run through the site and along the southern project boundary (Figure 4). Swamp forest wetlands exist adjacent to most of these streams and support hardwood species such as red maple (Acer rubrum), green ash (Fraxinus pennsylvanica), tulip poplar (Liriodendron tulipifera), black gum (Nyssa sylvatica), and sweetgum (Liquidambar styraciflua). Adjacent land use is mostly undeveloped and forested, with some residential and cleared fields. As noted above, five wetland/stream crossings were installed within the site (Figure 5). Two of these crossings (#4 and #5) are not needed and have since been removed and stabilized with jute matting (Appendix A). Three other road crossings remain in place (Crossings #1 - #3 on site plan; Appendix B). All three of these crossings are currently stabilized with several layers of silt fence. These crossings will be needed within the subdivision to provide access and utilities to the planned lots. Therefore, the developer proposes to restore sections of the unauthorized impacts at each crossing and apply for Section 404/401 permits for unavoidable impacts. See below for information about current conditions and proposed restoration efforts at each crossing. 4.0 Crossing Information 4.1 Crossing #1 Based on survey information and data collected by DRG in early 2021, the natural stream channel at Crossing #1 is approximately five feet wide. The contractor installed two 24" culverts and an approximate 45-ft wide dirt road at this location. Some rip rap was also installed at the downstream end of the culverts. When installing the culverts and the road, the contractor excavated the existing stream channel to between 20 — 25' wide both upstream and downstream of the crossing (Figure 6). Total unauthorized impacts at this location are 106 LF of stream and 0.045 acre of wetlands. A recent survey concluded that the culverts were installed too deep. The applicant plans to remove this road crossing and reinstall the two 24" culverts to the correct elevations (as noted on the site plan). Additionally, 38 LF of stream and 0.01 acre of adjacent wetlands will be restored (Figure 7). The proposed road crossing will permanently impact 68 LF of stream and 0.035 acres of wetlands. A Section 404/401 permit application will be submitted for this impact. 4.2 Crossing #2 The natural stream channel at Crossing #2 is approximately 7 feet wide. The contractor installed two 36" culverts and a 45' wide dirt road at this crossing. Some rip rap was also installed downstream of the culverts. Similar to Crossing #1, the contractor excavated the existing stream channel to between 20 — 25' wide both upstream and downstream of the crossing (Figure 8). The length of widening is between 20 LF and 25 LF at each location. Total unauthorized impacts at this location are 97 LF of stream and 0.06 acre of wetlands. The engineer recently determined that these culverts are undersized. The applicant plans to remove this crossing and replace with three 48" culverts. One culvert will be installed within the stream channel. The other two culverts will be raised 1.6' onto the stream banks to accommodate high flow events. Approximately 23 LF of stream will be restored (Figure 9). Note that areas immediately upstream and downstream of the culverts will remain open to allow water to pass through the culverts. The proposed road crossing, culverts, and rip rap will impact 74 LF of stream and 0.066 acres of wetlands. A Section 404/401 permit application will be submitted for this impact. 4.3 Crossing #3 The natural stream channel at Crossing #3 is approximately 7 feet wide. The contractor installed three 24" culverts and a 45' wide dirt road at this crossing. Some rip rap was also installed downstream of the culverts. The contractor excavated the existing stream channel approximately 17' wide both upstream and downstream of the crossing (Figure 10). The length of widening is between 13 LF and 17 LF at each location. Total existing impacts at this location are 87 LF of stream and 0.076 acre of wetlands. Similar to Crossing #2, the engineer recently determined that these culverts are undersized. The applicant plans to remove this crossing and replace with one 36" culvert and two 48" culverts. The 36" culvert will be installed in the 7' wide stream channel. The two 48" culverts will be placed in adjacent wetlands. Approximately 15 LF of stream and 0.003 acre of wetlands will be restored (Figure 11). The proposed road crossing, culverts, and rip rap will impact 72 LF of stream and 0.1 acres of wetlands. 5.0 Proposed Stream Restoration Methods At each of the three crossings discussed above, stream and wetland restoration work will occur. Prior to performing restoration activities, the contractor will ensure that silt fencing is secure. Additionally, rock check dams will be installed downstream of the restoration work. First -order stream channel restoration of pattern, profile, dimension, and riparian floodplain bench is proposed. The existing channel and riparian floodplain bench have been excavated for the installation of road crossings and culverts. Restoration activities are proposed for 76 linear feet of stream and 0.014 acres of riparian wetlands, encompassing Impact areas #1 - #3. Proposed restoration activities of the stream channel include the restoration of the natural channel dimension, profile, and plan form. Elevation of the channel bed and reconnection of the stream to the adjacent floodplain will re-establish characteristic riparian wetland hydrology. Additionally, the natural vegetated riparian buffer will be constructed to pre-existing grade. These areas will be planted with characteristic and native wetland species as those found in adjacent areas (i.e. red bay, wax myrtle, gallberry, fetterbush). Seed matting and stabilization will be installed to provide for the temporary stabilization of newly constructed areas. Jute/coir fiber matting will be installed along the restored stream banks and left in place indefinitely. Silt fencing and check dams will be removed once the areas are stabilized. 6.0 Proposed Monitoring Restored areas will be monitored for stability and after every heavy rain event until the area has stabilized. Any failure of the stream and/or riparian floodplain bench will be addressed immediately. An on -site meeting is proposed directly after restoration activities and three months after construction to review the restored areas for stability and closeout. FIGURES or,tE, itl r • 1i Sources: Esri, HERE, Garmin, USGS, Intermap, INCREMENT P, NRCan, Esri Japan, METI, Esri China (Hong Kong), Esri Korea, Esri (Thailand), NGCC, (c) OpenStreetMap contributors, and the GIS User Community, Esri, HERE, Garmin, (c) OpenStreetMap contributors L:\WETLANDS\2020 WETLANDS FILES\LMG20.121 --- Edens Lane Property, Logan Developers\Maps Boundaries are approximate and not meant to be absolute. Map Source: GIS World Street Map Layer N 0 1,000 2,000 4,000 A Feel Scale applies to 11X17" print. Bridgewater Landing Pender County, NC LMG Figure 1 Vicinity Map Map Date: January 2021 LMG20.121 LAND MANAGEMENT GROUP a WWEY1. company 3805 Wrightsville Avenue Wilmington, NC 28403 (910) 452-0001 L:\WETLANDS\2020 WETLANDS FILES\LMG20.121 --- Edens Lane Property, Logan Developers\Maps Boundaries are approximate and not meant to be absolute. Map Source: USGS Topsail Topographic Quad Bridgewater Landing Pender County, NC Map Date: January 2021 LMG20.121 LMG LAND) MANAGEMENT GROUP a DAVEYt company 3805 Wrightsville Avenue Wilmington, NC 28403 (910) 452-0001 N 0 350 700 1,400 A Feet Scale applies to 11X17" print. Figure 2 Topographic Map L:\WETLANDS\2020 WETLANDS FILES\LMG20.121 --- Edens Lane Property, Logan Developers\Maps Boundaries are approximate and not meant to be absolute. Map Source: 2016 GIS World Imagery Layer Bridgewater Landing Pender County, NC Map Date: January 2021 LMG20.121 LMG LAND MANAGEMENT GROUP a DAVEY1 company 3805 Wrightsville Avenue Wilmington, NC 28403 (910) 452-0001 S/Airbus OpenStreetMap N 0 250 500 1,000 A Feet Scale applies to 11X17" print. Figure 3 Current Aerial This is not a survey. All boundaries and distances are considered approximate. This represents a preliminary sketch prepared from field notes. A survey of delineated areas and review and approval by the US Army Corps of Engineers is recommended prior to specific site planning. CA123 tt PL , Uplands - 75.1 ac (86%) Wetlands - 12.6 ac (14%) Perennial Stream - 3,800 L.F. Intermittent Stream - 540 L.F. - --- Waters of the US (RPW) - 700 L.F. - 1-1-11 Non -Jurisdictional Ditch - 1,600 L.F. Wetland Line Off Property © Data Points L:\WETLANDS\2020 WETLANDS FILES\LMG20.121 --- Edens Lane Property, Logan Developers\Maps Boundaries are approximate and not meant to be absolute. Map Source: 2016 NC OneMap Aerial Photography Bridgewater Landing Pender County, NC Map Date: 04/24/2020 LMG20.121 LMG LAND MANAGE -WENT GROUP a DAVEY company 3805 Wrightsville Avenue Wilmington, NC 28403 (910) 452-0001 N 0 250 500 1,000 A Feet Scale applies to 11X17" print. Figure 4. USACE Approved Wetland Delineation Map This is not a survey. All boundaries and distances are considered approximate. This represents a preliminary sketch prepared from field notes. A survey of delineated areas and review and approval by the US Army Corps of Engineers is recommended prior to specific site planning. Uplands - 75.1 ac (86%) Wetlands - 12.6 ac (14%) Perennial Stream - 3,800 L.F. Intermittent Stream - 540 L.F. - --- Waters of the US (RPW) - 700 L.F. - 1-1-11 Non -Jurisdictional Ditch - 1,600 L.F. Wetland Line Off Property Road Crossings L:\WETLANDS\2020 WETLANDS FILES\LMG20.121 --- Edens Lane Property, Logan Developers\Maps Boundaries are approximate and not meant to be absolute. Map Source: 2016 NC OneMap Aerial Photography Bridgewater Landing Pender County, NC April 2022 LMG20.121 LMG LAND MANAGE -WENT GROUP a DAVEY company 3805 Wrightsville Avenue Wilmington, NC 28403 (910) 452-0001 N 0 250 500 1,000 A Feet Scale applies to 11X17" print. Figure 5. Road Crossings Overlaid On Wetland Map (Crossings 4 & 5 Removed) 1 1 1 1 1 1 Excavated Area w w w w n � SS FM FM FM FM 1 nr II m Unauthorized Stream Impact: 106 LF Unauthorized Wetland Impact: 0.045 ac Excavated Area ■■■ Existing Culvert 1 1 1 1 1 nauthorized Stream Impact: 106 LF 1- w 1— w nauthorized Wetland Impacts: 0_045-acre w w w w FM FM FM FM xcavated Area PRELIMINARY: NOT FOR CONSTRUCTION Survey and site plan information provided by: Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 BRIDGEWATER LANDING Pender County, NC SCALE: 1" = 20' Figure 6. Existing Conditions: Crossing #1 .■ ■ -estoration Area PAD = 29.00 Excavated Area FM FM 9.40 \ • \�\�\ i \ \ J \ \ \ \ \ \ \ • •y\ FM FM FIB\\ f \\\\\F\.\\ estorat on Area (130 sf) — — Proposed Stream Impact: 68 LF I====1 Proposed Wetland Impact: 0.035 ac — Excavated Area ® Proposed Restoration Area (447 sf) 1 1 1 1 1 1 — Proposed Headwall ■ ■ ■ Proposed Culvert • (317 sf) xcavated Area PRELIMINARY: NOT FOR CONSTRUCTION Survey and site plan information provided by: Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 BRIDGEWATER LANDING Pender County, NC SCALE: 1" = 20' Figure 7. Proposed Crossing #1 71.gM 13M I 1.3M T� M OFT 4# / f Unauthorized Stream Impact: 97 LF 1 1 9 1 / 1 1 1 1 1 1 1 // 1 1 1 1 1 1 \ xcavated Area 1 1 1 nauthorized Wetland Im.: _ s: 0.056 ac xcavated Area Unauthorized Stream Impact: 97 LF (:::=1 Unauthorized Wetland Impact: 0.06 ac — Excavated Area ■■■ Existing Culvert PRELIMINARY: NOT FOR CONSTRUCTION Survey and site plan information provided by: Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 BRIDGEWATER LANDING Pender County, NC SCALE: 1" = 20' Figure 8. Existing Conditions: Crossing #2 1 1 Area to Remain O•en to Allow Water to Flow rivAsywarrdp-47 --v Area to Remain O•en to Allow Water to Flow 1 1 1 1 1 1 1 1 1 1 1 xcavated Area — — Proposed Stream Impact: 74 LF Proposed Wetland Impact: 0.066 ac — Excavated Area — Proposed Headwall ■■■ Proposed Culvert PRELIMINARY: NOT FOR CONSTRUCTION Survey and site plan information provided by: Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 BRIDGEWATER LANDING Pender County, NC SCALE: 1" = 20' Figure 9. Proposed Crossing #2 1 JET 1 1 i 1 1 1 1 /1 44/ // / 44, // 11 Ixcavated Area I 1 /77 1 hargnel 1 Unauthorized Stream Impact: 87 LF ====� Unauthorized Wetland Impact: 0.076 ac — Excavated Area ■■■ Existing Culvert SCALE: 1" = 20' PRELIMINARY: NOT FOR CONSTRUCTION Survey and site plan information provided by: Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 BRIDGEWATER LANDING Pender County, NC Figure 10. Existing Conditions: Crossing #3 1 Res ration Area (74 sf) ' 1 1 1 1 1 // yo dd 44.10:0, i;_vj — — Proposed Stream Impact - 72 LF Proposed Wetland Impact - 0.1 ac — Excavated Area Proposed Restoration Area (148 sf) 1 / 1 I xcavated Area 1 1 4 — Proposed Headwall ■ ■ ■ Proposed Culvert /77 1 1 1 1 1 hagnel —Restoration Area (74 sf) 1 PRELIMINARY: NOT FOR CONSTRUCTION Survey and site plan information provided by: Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 BRIDGEWATER LANDING Pender County, NC SCALE: 1" = 20' Figure 11. Proposed Crossing #3 Appendix A. Site Photos Bridgewater Landing; Pender County Appendix A. Site Photos Note: Photos of Crossings 1-3 taken in February of 2022. Additional silt fencing has been installed since then. Looking Downstream at Crossing #1 Looking Upstream at Crossing #1 Bridgewater Landing; Pender County Appendix A. Site Photos Looking Upstream at Crossing #2 Looking Downstream at Crossing #2 Bridgewater Landing; Pender County Appendix A. Site Photos Looking Upstream at Crossing #3 Looking Downstream at Crossing #3 Bridgewater Landing; Pender County Appendix A. Site Photos Crossing #4 (with road still present) Crossing #4 (restored; photo taken 3/3/22) Bridgewater Landing; Pender County Appendix A. Site Photos Crossing 5 (with road still present) Crossing 5 (with road present and sediment in channel) Bridgewater Landing; Pender County Appendix A. Site Photos Crossing 5 (restored; photo taken 3/3/22) Crossing 5 (Restored; looking downstream; photo taken 3/3/22) Appendix B. Site Plan Drawings NORTH LOCATION MAP SCALE: 1 "=1,000' SITE INFORMATION APPLICANT INFORMATION: OWNER: CURRENT LAND USE: CAMA LAND USE PLAN DESIGNATION: EXISTING ZONING: PROPOSED ZONING: PIN: TOWNSHIP: DEED BOOK/ PAGE: PROPOSED USE: LOGAN DEVELOPERS 60 GREGORY RD, SUITE 1 BELVILLE, NC 28451 EDENS LANE, LLC 60 GREGORY RD, SUITE 1 BELVILLE, NC 28451 VACANT LAND EX. GRADE, TYP. PROPOSED RI RAP APRON LOW DENSITY RESIDENTIAL/COASTAL RESIDENTIAL RP RP 4214-14-4919-0000 (86.18 ACRES) TOPSAIL 4683/103 SFD- SINGLE FAMILY DWELLING DETACHED CONVENTIONAL (SEC. 4.15.1) TOTAL SITE AREA: ±86.40 ACRES SINGLE FAMILY DIMENSION REQUIREMENTS PROPOSED HOUSING TYPE: ALL UNITS ARE SINGLE FAMILY DWELLING DETACHED CONVENTIONAL (SEC. 4.15.1) DIMENSION (LID OPTION): MINIMUM LOT SIZE: MAXIMUM LOT SIZE: FRONTYARD SETBACK: SIDEYARD SETBACK: CORNER SIDEYARD SETBACK: REAR SETBACK: MAXIMUM BUILDING HEIGHT: STRUCTURE SEPARATION (ON SEPARATE LOTS): MINIMUM CHORD DISTANCE: MINIMUM LOT WIDTH: UNIT TOTALS & SITE YIELD TOTAL SINGLE FAMILY: 139 LOTS 9,000 SF 60,000 SF 15' MINIMUM 5' MINIMUM OPEN SPACE TOTAL REQUIRED OPEN SPACE 139 LOTS x 0.03 AC 15' MINIMUM 12.5' MINIMUM 35' 15' MINIMUM 15' 30' 4.17 AC 50% MIN. ACTIVE SPACE REQUIRED: ±2.09 AC ACTIVE OPEN SPACE PROVIDED: ±2.31 AC PASSIVE OPEN SPACE PROVIDED: ±16.23 AC TOTAL OPEN SPACE PROVIDED: ±18.54 AC NAICS CODE USE (No Code) SFD: SINGLE FAMILY DETACHED - CONVENTIONAL AND ALL USES ASSOCIATED WITH CONSTRUCTION AND SALE OF HOMES, TEMPORARY BUILDINGS FOR CONSTRUCTION OR DEVELOPMENT, AMENITIES, ETC. FLOODPLAIN NOTES 1. THIS PARCEL IS IN FLOOD ZONE X, WHICH IS NOT A SPECIAL FLOOD HAZARD AREA, ACCORDING TO FEMA FLOOD PANELS 3720320400J AND 3720329200J WITH AN EFFECTIVE DATE OF FEBRUARY 16, 2007. WETLAND NOTES 1. THERE ARE WETLANDS ON THE PROPERTY. WETLAND JD IS APPROVED HISTORICAL & ARCHAEOLOGY NOTES 1. NO KNOWN HISTORIC OR ARCHEOLOGICAL SITES EXIST ON ANY OF THE SUBJECT PARCELS. Wetland Impacts WETLAND IMPACTS IMPACT AREA LENGTH PERMANENT IMPACT LF SF ACRES 1 62 1,890 0.043 2 68 3,200 0.073 3 70 4,275 0.098 4 0 1,580 0.036 TOTAL IMPACTS = ' 200 10,945 0.251 w z J HENNINGS DRIVE 50' PRIVATE RIGHT-OF-WAY w z J -62' IMPACT AREA 1/4" PER FT 1/4" PER FT PROPOSED RETAINING WALL OPROPOSED FORCE MAIN EDENS LANE 60' PUBLIC ROW OPROPOSED O PROPOSED SANITARY SEWER WATER MAIN PERM. IMPACT LIMIT PROPOSED GRADE, TYP. -,J EX. GRADE, TYP. PROPOSED RIP RAP APRON — PROPOSED (2) 50 LF 24" RCP CULVERT WITH HEADWALLS PER NCDOT STANDARDS & PROPOSED SPECIFICATIONS (BURIED 5") RETAINING WALL WETLAND IMPACT AREA 1 TYP. CROAD CROSS SECTION NOT TO SCALE yCC /VETLAN TYP LJJ \ALQ W W 90' 0' 20' V47EA THERBEE A Y� 50' PRIVATE ROW p. ---IAI,I �� IA J 10' x 70' SIGHT TRIANGLE, TYP. w z HENNINGS DRIVE 50' PRIVATE RIGHT-OF-WAY -68' IMPACT AREA IMPACT LIMIT 1/4" PER FT 1/4" PER FT OPROPOSED WATER MAIN PROPOSED RETAINING WALL OPROPOSED 0 PROPOSED SANITARY SEWER FORCE MAIN — PROPOSED (1) 52 LF 48" RCP CULVERT WITH HEADWALLS PER NCDOT STANDARDS & SPECIFICATIONS (BURIED 10"), (2) 48" RCP FOR HIGHER STORMS WETLAND IMPACT AREA 2 TYP. CROAD CROSS SECTION NOT TO SCALE PERM. IMPACT LIMIT PROPOSED GRADE, TYP. --J PROPOSED RETAINING WALL EX. GRADE, TYP. PROPOSED RIP RAP APRON NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS 200 NORTH SCALE: 1 "=200' 400 HENNINGS DR 50' PRIVATE ROW 600 IARITT STREE 50' PRIVATE RO PROPOSEI RETAINING WALL 30 25 20 PROPOSED RIP RAP APRON 15 10 rn N N STORMWATER BMP 50' PRIVATE RIGHT-OF-WAY -10' II 30 STORMWATER BMP wW TLAND TYP.. ROPOSED GRADE XISTING GRADE PROPOSED / RETAINING WALL PROPOSED RETAINING WALL 20 ITCH BOTTOM W/5" BURIED PIPE 15 (2) 24' RCP (5" (FILL AT BOTTOM) INV UP 20.50 INV DOWN 20.30 10+00 10 WETLAND IMPACT AREA 1 CROSS SECTION 1 "=50' HORIZONTAL 1 "=5' VERTICAL 25 20 15 W z LANGSTON ROAD 50' PRIVATE RIGHT-OF-WAY -70' IMPACT AREA IMPACT LIMIT 1/4" PER FT 1/4" PER FT OPROPOSED WATER MAIN PROPOSED RETAINING WALL PERM. IMPACT LIMIT PROPOSED GRADE, TYP. \ PROPOSED O PROPOSED SANITARY SEWER FORCE MAIN — PROPOSED (1) 50 LF 36" RCP CULVERT WITH HEADWALLS PER NCDOT STANDARDS & SPECIFICATIONS (BURIED 7"), (2) 48" RCP FOR HIGHER STORMS WETLAND IMPACT AREA 3 TYP. CROAD CROSS SECTION NOT TO SCALE 5' SIDEWALK ALONG COLLECTOR ROADS, REFER TO STREET CROSS SECTION, THIS SHEET \� _I STORMWATER BMP 50' PRIVATE RIGFT-OF-WAY 25 PROPOSED GRADE 20 ----PROPOSED RETAINING WALL (52' BETWEEN RETAINING WALLS DITCH BOTTOM W/10" BURIED 10 Pr 5 0 15 XISTING GRADE PROPOSED RIP RAP APRON 10 \--(1) 48" RCP (10" (FILL AT BOTTOM) INV UP 13.70 INV DOWN 12.30 (2) 48" RCP (HIGHER STORMS) INV UP 15.20 INV DOWN 13.80 O CV 10+00 0 PENDER COUNTY GROUP 1 COLLECTOR ROAD WETLAND IMPACT AREA 2 CROSS SECTION 1 "=50' HORIZONTAL 1"=5' VERTICAL PROPOSE RETAINING WALL 25 20 15 STORMWATER BMP 90' PRI' /ATE RIGHT OF -WAY DITCH BOTTO W/7" BURIED PIPE i 5 0 15' PROPOSED RETAINING WALL PUMP STATION EI 25 PROPOSED GRADE 20 PROPOSED RETAINING WALL (55' BETWEEN RETAINING WALLS EXISTING GRADE 10 1 0 ROPOSED RIP RAP APRON 1) 36" RCP (7" (FILL AT BOTTOM) INV UP 10.85 INV DOWN 10.60 (2) 48" RCP (HIGHER STORMS) INV UP 15.60 INV DOWN 15.35 C N- CO 71- CO N 0 WETLAND IMPACT AREA 3 10+0o CROSS SECTION 1"=50' HORIZONTAL 1 "=5' VERTICAL REVISIONS: NCDEQ PH 2 EC 01/28/22 CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITF, 1 BELVILLE, NC 28451 ENGINEERING, INC. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 03.30.21 SCALE: 1" = 200' DESIGNED: AHE DRAWN: JRC CHECKED: AHE SEAL\ \\\\\IiiiiiCAR�//// , 'sN,... Olt /0„ / - .OS9lq _ 028847 _- 'moo` NGINE��°*1 /////Illni\\\\ 3/11/22 1 FIG PEI JOB#: 20178.PE EDENS LANE i 1 kali ( II, 11111111 n r 7 SHT. C-4.1 SHT. C-4.2 SHT. C-4.3 SHT. C-4.4 KEY MAP 41. NOT TO SCALE O SEE SHEET C-4.0 FOR SWALE SCHEDULE LEGEND: ---16--- 16 NOTATION: EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SWALE PROPOSED RETAINING WALL (BY OTHERS) DI PG EX HP LP sw TW BW = DROP INLET = PROPOSED GRADE = EXISTING GRADE = HIGH POINT ELEVATION = LOW POINT ELEVATION = SIDEWALK ELEVATION = TOP OF WALL ELEVATION = BOTTOM OF WALL ELEVATION CULVERT #2 [54 LF] [2] 18" RCP CL IV PIPE INV.UP=26.20 PIPE INV.DWN=26.00 DRAINAGE EASEMENT (TYP.) 1 1 1 JAMES R HALL II PIN: 4214-06-6482-0000 DB 634, PG 92 PB 21, PG 36 ' w EDENS LANE 1 EXIST. U`60/W (PUBLIC) 1 1 1 1 1 M M POND 1 INLET RIP -RAP APRON [10'X20'] SSEt- SS SWALE 9 L DRIVEWAY CULVERT #2 [60 LF] 24" RCP CL III (W/ FES) [4.8" FILL AT BOTTOM] PIPE INV.UP(NW)=26.10 PIPE INV.DWN(SE)=25.85 r RIP RAP APRON (TYP. - SEE DETAIL) EL29.45 v �\ PROPOSED SWALE 2/ J (TYP.-SEE DETAIL) CULVERT #5 [52 LF] [3] 24" RCP CL IV PIPE INV.UP=25.60 PIPE INV.DWN=25.40 - 26� STORM SCHEDULE: HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-15-0974-0000 DB 4725, PG 1766 29- �27 POND 1 EMERGENCY SPILLWAY [SEE DETAIL] ji C I \ \ ``+� TW 25.00 BW21.4± \ \ TW 25.50 BW 25.50 SWALE 15 28 - -1.25 1.25 POND 1 OUTLET STRUCTURE [SEE DETAIL] POND 1 SKIMMER [SEE DETAIL] BRYAN TRAVIS HALL PIN: 4214-15-3749-0000 DB 1858, PG 210 ERICA LEWIS PIN: 4214-15-4757-0000 DB 4167, PG 220 B B LOB LBD tU ., -L-tl 3g_ 2 \ 111 \ / / 1 / TW 25.00� BW 25.00 WETLAND TW 25.50 [2] 24" BW 24.00 [5" FILL PIPE PIPE SWALE L 0 CROSSING #1 [50 RCP CL III (OR HDPE) AT BOTTOM] INV.UP=20.50 INV.DWN=20.30 18 �_ - - �6 / � LF] -�" _ _ - PAD 27.00/ / ' / �� ( � y� Act \ • \ \ISN \ \ s2\ \ _ _ �� s PAD 25.50 �' �\\ - \ I r- J I \ \ J /�/ k PAD 26.00 25 -� 25 // _- ��� ;,>,,; �, -c.1l \ \ �, \N. i - _ �, SWA 21 '�=i a �TW 19.0� vv v�, �. ._ BW 19.01 \2 ��.`"``�����0 TW 22 2 � BW 1E a� A.°• E 20 _ \or* WETLANDS POND 1 RIP -RAP APRON [SEE DETAIL] VV Ira)! 00.47 I � a'c' EL28.87 y SILT FENCE (TYP.-SEE DETAIL) SEE SHEET C-4.5 FOR AMENITY GRADING PLAN .00 .50 At- vv wirgrismarA, ritWri 4!riOi TW 20.00 rr:� BW 20.00 • �'�,� `i TW2 0 BW 20.00 RETAINING WALL (BY OTHERS), TYP. 1-1 'HOPE OR RCP; IF MEETS AND CONST CTED PER NyFACTURER SPECIFICATIONS / J � \ E�TALLSTORF\4DRAU'J4\GE PIPING QAN B I NSTRUCTED WITH E Upstream Node Downstream Node Diameter (In) Upstream Invert Downstream Invert Pipe Length (ft) Slope (%) Upstream Rim Elev Downstream Rim Elev MH-4.1 FES-3.1 36 20.13 17.00 37 8.51 31.03 20.00 DI-2.1 MH-4.1 1 36 20.36 20.13 80 0.30 26.00 31.03 J L MORRIS ENTERPRISES PIN: 4204-95-5947-000L DB 1089, PG 274 PB 22, PG 39 I\ / / I ICJ 29 - = - 27 TW 22.00 BW 14.5± TW 23.00 BW 19.00 TW 19.00 BW 19.00 0 sv HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-15-7760-0000 DB 4725, PG 1766 \\ TW 22.00 BW 14.2± \WETL\ DS \ \ \ Wit✓_ i. WETLAND CROSSING #2 [52 LF] 48" RCP CL III [PRIMARY] / [10" FILL AT BOTTOM] PIPE INV.UP=13.70 PIPE INV.DWN=12.30 TW 20.00 / BW 20.00 50'R/ti / WETLAND CROSSING #2 [52 LF] / [2] 48" RCP CL III [SECONDA PIPE INV.UP=15.20 PIPE INV.DWN=13.80 0.70 SS / 1 1 1 1 1 1 1 1 2' (PRIVATE) / 001 GRAPHIC SCALE 0 25 50 100 200 SCALE: 1 "=50' 1 1 1 1 1 1 1 1 1 1 1 Know what's below. CaII before you dig. U LJJ LLJ LLJ L.IJ REVISIONS: NCDEQ PH 2 EC 01/28/22 02/28/22 WETLAND CROSSING REVISION CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 E N G I N E E R I N G, INC. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: 1 "=50' DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL\��\�iiiiliiio, \\,\\\\.\N CAR///////// - 028847 2'O �• cciVGI NE`G" . ° //io r G. 0 L Nx \\\\\ 3/11/22 4•2 C PEI JOB#: 20178.PE EDENS LANE ) vole SHT. C-4.1 SHT. C-4.2 SHT. C-4.3 SHT. C-4.4 KEY MAP 1.i., NOT TO SCALE P 0 i 2 SEE SHEET C-4.0 FOR SWALE SCHEDULE LEGEND: 16 NOTATION: EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SWALE PROPOSED RETAINING WALL (BY OTHERS) DI PG EX HP LP SW TW BW = DROP INLET = PROPOSED GRADE = EXISTING GRADE = HIGH POINT ELEVATION = LOW POINT ELEVATION = SIDEWALK ELEVATION = TOP OF WALL ELEVATION = BOTTOM OF WALL ELEVATION U LLJ LLJ LLJ LLJ 1 1 1 1 1 1 1 1 1 1 ss 01 7 -18 Q0/ a01 WETLANDS TO REMAIN UNDISTURBED, TYP. LOD ROAD F2 C01 X POND 3 INLET RIP -RAP APRON [10'X20'] CULVERT #7 [50 LF] [2] 15" RCP CL IV PIPE INV.UP=25.20 PIPE INV.DWN=25.00 CULVERT #6 [56 LF] [2] 18" RCP CL IV N PIPE INV.UP=24.75 PIPE INV.DWN=24.25 /. PROPOSED SWALE (TYP.-SEE DETAIL) ALE 31 POND 2 INLET RIP -RAP APRON [10'X20'] HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-25-3147-0000 DB 4725, PG 1766 \ WET POND 3 \O WET3l\ POND 3 EMERGENCY SPILLWAY [SEE DETAIL] n POND 2 RIP -RAP APRON [SEE DETAIL] POND 2 OUTLET STRUCTURE [SEE DETAIL] J L MORRIS ENTERPRISES PIN: 4204-95-5947-000L DB 1089, PG 274 PB 22, PG 39 POND 3 OUTLET STRUCTURE [SEE DETAIL] ,\\ POND 3 RIP -RAP APRON [SEE DETAIL] WETLAND CROSSING #3 [50 LF] 36" RCP CL III [PRIMARY] [7" FILL AT BOTTOM] PIPE INV.UP=10.85 PIPE INV.DWN=10.60 -RIP RAP APRON (TYP. - SEE DETAIL) \ RETAINING WALL (BY OTHERS), TYP. NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS WETLANDS WETLAND IMPACT FOR \ N. ROAD AND CULVERT INSTALLATION, TYP. WETLAND CROSSING #3 [50 L[E] 48" RCP CL III [SECONDARY] PIPE INV.UP=15.60 PIPE INV.DWN=15.35 / \ 001 GRAPHIC SCALE 0 25 50 100 POND 4 RIP -RAP APRON [SEE DETAIL] POND 4 OUTLET STRUCTURE [SEE DETAIL] POND 4 SKIMMER [SEE DETAIL] 200 SCALE: 1 "=50' 1 1 1 1 1 1 1 1 \01 1 1 1 1 1 1 1 Know what's below. CaII before you dig. LLJ z_ J U CQ REVISIONS: NCDEQ PH 2 EC 01/28/22 N N co N N O WETLAND CROSSING REVISION CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 E NIGIN E E R 1 N G. I N C. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: 1 "=50' DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL ooliuiiiii 028847 :co :3 °° O `° �NGI NEB' ' /,/ /Y G. C1.0 \\\\\\ I 3/11/22 4•3 c PEI JOB#: 20178.PE EDENS LANE ° I i__,. ) Vail SHT. C-4.1 SHT. C-4.2 SHT. C-4.3 SHT. C-4.4 KEY MAP 4* , NOT TO SCALE i.P 0 2 1 1 1 1 WET WETLANDS 1 1 1 WET POND 4 [SEE DETAILS] 1 1 1 1 1 WET CT SEE SHEET C-4.0 FOR SWALE SCHEDULE ET \\ „ l/ I / POND4EMERGENCY SPILLWAY [SEE DETAIL] DRAINAGE EASEMENT (TYP.) POND 4 INLET RIP -RAP APRON [10'X20'] J L MORRIS ENTERPRISES PIN: 4204-95-5947-000L DB 1089, PG 274 PB 22, PG 39 aTi ' PAD = 28.90 PAD = 29.75 -1.28-1.28 LEGEND: 16 EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SWALE PROPOSED RETAINING WALL (BY OTHERS) NOTATION: HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-25-3147-0000 DB 4725, PG 1766 POND 5 INLET RIP -RAP APRON [10'X20'] PAD = 26.60 DI PG EX HP LP SW TW BW = DROP INLET = PROPOSED GRADE = EXISTING GRADE = HIGH POINT ELEVATION = LOW POINT ELEVATION = SIDEWALK ELEVATION = TOP OF WALL ELEVATION = BOTTOM OF WALL ELEVATION PAD = 25.25 Q12 / PROPOSED SWALE 4 (TYP.-SEE DETAIL) i J L MORRIS ENTERPRISES PIN: 4214-23-2291-0000 DB 3362, PG 68 STORM SCHEDULE: Upstream Node Downstream Node Diameter (In) Upstream Invert Downstream Invert Pipe Length (ft) Slope (%) Upstream Rim Elev Downstream Rim Elev MH-8.4 FES-8.1 18 20.43 19.50 220 0.42 26.27 19.50 DI-8.2 MH-8.4 18 20.50 20.43 25 0.30 24.75 26.27 DI-8.3 DI-8.2 18 21.50 20.50 54 1.85 24.75 24.75 i PAD = 22.85 CULVERT #9 [54 LF] [2] 12" RCP CL IV PIPE INV.UP=20.50 PIPE INV.DWN=20.30 NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS RETAINING WALL (BY OTHERS), TYP. c PG 18.21 PG 18.30 SS POND 5 INLET RIP -RAP APRON [10'X20'] WET POND 5 [SEE DETAILS] POND 5 SKIMMER [SEE DETAIL] -4-2-- TW 14.00 12 BW 14.00 POND 5 EMERGENCY SPILLWAY [SEE DETAIL] WETLANDS GRAPHIC SCALE 0 25 50 100 WETLANDS 200 SCALE: 1 "=50' 0 F- J Z o (NJ J Lo Q p N Cn O Ur 0 i 0 L C) W co m CD Q Z Z c9 0 m LL 0 0 N 0 v7 O W co 0) 0 0 M 00 0 Know what's below. CaII before you dig. REVISIONS: NCDEQ PH 2 EC [ 01/28/22 CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 E N G I N E E R 1 N G. I N C. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: 1 "=50' DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL \\\\\1HI!///0 028847 O `° �NGI NEs- °° ''' /,/ Y /G. C L N�\\\\\� I 3/11/22 4•4 c PEI JOB#: 20178.PE LOCATION MAP SCALE: 1 "=1,000' SERVICE NOTE: 1. CONTRACTOR SHALL INSTALL ONE (1) 1-INCH WATER SERVICE PER LOT AND ONE (1) 4-INCH SEWER SERVICE PER LOT. J L MORRIS ENTERPRISES P1N:4204-95-5947-000L DB 1089, PG 274 PB 22, PG 39 ZONING: GB PROPERTY LINE (TYP.) 10 UTILITY NOTES: (NCAC 15A.02T.0305 / T15A.18C.0906) 1. WATER MAINS SHALL BE LAID SO AS TO PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 10 FEET FROM SEWERS. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, THE WATER MAIN CAN BE INSTALLED AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER, EITHER IN A SEPARATE TRENCH, OR IN THE SAME TRENCH ON A BENCH OF UNDISTURBED EARTH. 2. WHEN CROSSING A WATER MAIN OVER A SEWER, THE WATER MAIN SHALL BE LAID AT LEAST 18 INCHES ABOVE THE SEWER. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH JOINTS THAT MEET WATER MAIN STANDARDS. THE DUCTILE IRON PIPE SHALL EXTEND 10 FEET ON EACH SIDE OF THE CROSSING WITH A SECTION OF WATER MAIN PIPE CENTERED ON THE CROSSING. 3. CROSSING A WATER MAIN UNDER A SEWER. WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. 4. WHERE VERTICAL CLEARANCE IS LESS THAN 24" BETWEEN SANITARY SEWER AND STORM DRAIN, SANITARY SEWER SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 5. WHERE VERTICAL CLEARANCE IS LESS THAN 18" BETWEEN WATER MAIN AND STORM DRAIN, WATER MAIN SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 6. A MINIMUM VERTICAL DISTANCE OF 12" SHALL BE MAINTAINED BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF OTHER UTILITIES. MATCHLINE - SHEET C-5 3 co act- tvo \\� a h 7 i 0 11+00 -3 (1) 8"x8" MJ TEE (2) 8" MJ GATE VALVE -km- SSMH-042 -N HENNINGS DRIVE 50' PRIVATE RNV / PROPOSED CULVERT (TYP.) SSMH-030 (SEE GRADING AND DRAINAGE PLANS) 1 MATCHLINE - SHEET C-5.6 8" C-900 (DR-18 PVC WATER MAIN PROPOSED SWALE (TYP.) (SEE GRADING AND DRAINAGE PLANS) o HENNINGS DRIVE PLAN VIEW STA. 10+00 TO STA. 16+50 HORIZONTAL SCALE: 1 =50 NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS 45 40 35 30 25 20 15 10 SSMH-030 MATCHLINE - SHEET C-5.2 ��� I _I■,' uulm- SSMH-031 SSMH-029 (1) 8" X 6" MJ TEE (1) FIRE HYDRANT ASSEMBLY 0 co (1)8"x8"MJTEE c" (2) 8" MJ GATE VALVE PROPOSED DRAINAGE EASEMENT (TYP.) w 0 w 01 MATCHLINE - SEE RIGHT (1) 8"x8" MJ TEE (2) 8" MJ GATE VALVE LANE 50 ACIVATE R/nN PR% MATCHLINE - SEE LEFT GRAVITY SEWER NOTES; 1. ALL MANHOLES LOCATED WITHIN 50' OF WETLANDS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1.1. SEAMS SHALL BE EXTERNALLY TAPED / SEALED WITH WATERTIGHT MATERIAL. 1.2. ALL MANHOLE INTERIORS SHALL BE FULLY LINED WITH WATERPROOF COATING. 1.3. MANHOLES SHALL BE TESTED IN ACCORDANCE WITH ASTM C1244 "STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY NEGATIVE AIR PRESSURE (VACUUM) TEST PRIOR TO BACKFILL. 2. ALL SEWER PIPE MATERIALS, INSTALLATION, AND TESTING SHALL MEET WATER MAIN STANDARDS WHEN LOCATED WITHIN 50' OF WETLANDS. WATER MAIN NOTES; 1. ALL WATER MAIN SHALL BE INSTALLED A MINIMUM OF 5' FROM EDGE OF PAVEMENT. 2. NO VALVES, HYDRANTS, OR OTHER WATER MAIN APPURTENANCES SHALL BE INSTALLED IN THE SWALES. FORCE MAIN NOTES; 1. ALL FORCE MAIN SHALL BE INSTALLED A MINIMUM OF 5' FROM EDGE OF PAVEMENT. 2. NO VALVES OR OTHER FORCE MAIN APPURTENANCES SHALL BE INSTALLED IN THE SWALES. PAD = 30.50 43 \ \ 29 1 ..o ss 1 WINO saiNNIN 1 tic 'Y 9Ooo��O / / / PAD = 29.85 \ \ Cr (1) 8" X 6" MJ TEE (1 FIRE HYDRANT ASSEMBLY 2:.82 8" C-900 (DR-18) PVC WATER MAIN - HENNINGS DRIVE I 50' PRIVATE R/W 17+00 ss ss s 1 ■ 4" C-900 (DR-18) PVC FORCE MAIN (4' MIN. COVER) 1 A ,A L PAD Era-vu' 17.:ui>w\u \ 1800 \ / .I. i 1 1 . 18 / ►4 Lv.a MIE \1 SSMH-028 (1) 4" MJ 90° BEND - 29-- J / /I PAD = / PG 28.00 / \ N I,/� 4" C-900 (DR- 8) II PVC FORCE MAIN I, (4' MIN. COVER) , I PAD = 29.40 HENNINGS DRIVE PLAN VIEW STA. 16+50 TO STA. 19+50 HORIZONTAL SCALE: 1 "=50' FM F IGH POINT STA. = 10+55.43 HIGH POINT PVI STA. ELEV. = 10+75.00 = 32.55 PVI STA. = 11+50.00 PVI ELEV. = 32.79 PVI ELEV. = K = 56' 31.59 K=43' VC 50' VC -0- N v 100' LOW POINT STA. = 15+60.87 HIGH HIGH POINT POINT STA. ELEV. = 16+86 = 29.45 53 m o 6 rn co it II LOW POINT PVI STA. ELEV. = 15+60.63 = 28.87 PVI PVI STA. ELEV. = 17+00.63 = 29.67 LOW POINT STA. = 18+95.16 _+ II II + a? ,- ¢ w PVI ELEV. = 28.69 K = 51' LOW l'VI POINT STA. ELEV. = 18+§5.63 = 27.61 VC STA. VC ELE\ co U 1- w K = 71' ELEV� = 29.32 100' VC PV ELEV. K - 48' = 2 .36 co 100 VC m M a a 0 r> 00 o +l0 o 100'VC I P + ELEV. = 29.i I I I I t CO N ( II PVT EL EV1= 21 co CO lf)r PROPOSED GRAD E II la> II II �_ . 070 ° /° a EXISTING GRADE ¢ II • - v I- [2] 18" 0 RCP _ - ---- -- >-> a d a - >-- ---- _ 0.71 % - - --------- _ --------- a__ a_____ 0 a a 0 vrLL� �a [2] 18" 0 RCP ----- -- ---- I2 �- 25��0 4' C-900 PVC FORCE (DR-18) MAIN - � 11111.1111111M \\ o 11� [3](4' 24" RCP MIN. COVER) / 175 LF OF 8 IN. C-900 PVC (DF �� � \ ` 8"CAT 149 11 I- i - -"--' LF OF 8 IN. C -900 PVC (DR-18) ° PVC WATER R MAIN) @ -0.40 /° � � '�i.�////jl ` �/ 154 LF (TOTAL) OF 8 IN. � - � SANITARY/WATER CROSSING. USE 45° VERT. -� I w 6 C-900 PVC (DR-18) @ -0.40% 7 ,, 140 LF OF PVC (DR-18) 8 N. C-900 \i __,„if 1255 LF TOTAL OF 12" MIN. @ -0.40/0 BENDS & DUCTILE IRONli WATER/STORM CROSSING. PIPE TO PROVIDE 18" MIN. x._ i USE DUCTILE 45° VERT. BENDS & IRON PIPE TO SEPARATION AS REQ'D PROVIDE 18"MIN. [TYP.] (SEE NOTE) - WATER/STORM CROSSING. USE 45° [2] 24" RCP 18' MIN. SANITARY/WATER J SEPARATION AS REQ'D SANITARY / STORM CROSSING. VERT. BENDS & CROSSING. USE 45° VERT. I �l [TYP.] (SEE NOTE) PROVIDE 20 LF DIP (PRESSURE CL. (SMHI-048) DUCTILE IRON PIPE BENDS & DUCTILE IRON 9 9 9 0 0 0 4 o 350) SANITARY MAIN CENTERED AT CROSSING AND BRIDGE STORM M TO PROVIDE 18" MIN. M 0 N 0 PIPE TO PROVIDE 18" MIN. SEPARATION AS REQ'D _ _ = 2 2 2 i- 2 - SEWER AS REQ'D[TYP. - 0" TO 12" SEPARATION AS = [TYP.] (SEE NOTE) <n cn-cn u) u) u) o cn _ o SEPARATION] (SEE NOTE & DETAIL) REQ'D [TYP.] (SEE NOTE)s cn 0O �N CO CO CO IO .... M CCOO 7 ! (�I M T = 24.72 UT=24I C M (�I INV IN = 23.32 INV OUT = 23. STA. = 17+87 RIM = 28.60 N O- N N N M II II II Is SSMH-04£ -A. = 13 M=30.: V IN = 2 V OUT O-•�+Nr... co N II O N N II co O in (�2»» II zzz0 2 2 II II zz0 2 > » rII. II ZC• aiH »cn _ wcoEzzzz ���zz� cn�n�z� Iu) Mf-- N MN CO N N MN M NN N MN M I-- M M.- M LC) O M M rnrn N O MO M ,-M 00 MO M CO O MO M CO CO O MO M CO Mf-- 00 O MO N MN O MO N CO O Mcd N CO CflCO M O Ncd N I--N O NO N CflM M O NO N e0LO M NO N ,-M O O Ncd N CflM O N N M M I: N N N- 0) O O ti N N 9+50 10+00 11+00 12+00 13+00 14+00 15+00 HENNINGS DRIVE - PROFILE VIEW STA. 10+00 TO STA. 19+50 HORIZONTAL SCALE 1 "=50' VERTICAL SCALE: 1 "=5' 16+00 17+00 18+00 19+00 45 40 35 30 WATER/STORM CROSSING. PROVIDE 18" MIN. SEPARATION AS REQ'D 25 [TYP.] (SEE NOTE) SANITARY/STORM 20 CROSSING. PROVIDE 20 LF DIP (PRESSURE CL. 350) SANITARY MAIN CENTERED AT CROSSING 15 10 19+50 FORCE MAIN / STORM CROSSING. PROVIDE 18" MIN. SEPARATION AS REQ'D [TYP.] (SEE NOTE) GRAPHIC SCALE 0 25 50 100 200 SCALE: 1 "=50' REVISIONS: NCDEQ PH 2 EC 01/28/22 CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 E NIGIN E E R 1 N G. I N C. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: 1" = 50' DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL \\\\\III H//// \\\\\\. CARGL�/////, °pFES 9 1 028847 O °° �NGI N -s' .** � //////Y G. L I\ NS\\\\\ 16 3/11/22 C 5•4 PEI JOB#: 20178.PE (1) 2"X2" COMPRESSION WYE REDUCE TO IRRIGATION SERVICE CLASS 200 CTS POLYETHYLENE (1) 1" 45° BEND LO U w W ' AG \ SERVICE NOTE: 1. CONTRACTOR SHALL INSTALL ONE (1) 1-INCH WATER SERVICE PER LOT AND ONE (1) 4-INCH SEWER SERVICE PER LOT. ( 13M / (1) 2" DOMESTIC METER (PER PCU STD. DETAIL) (1) 2" RPZ BFP & ENCLOSURE (WATTS LF909 OR APPROVED EQUAL) PROVIDE 6" SEWER SERVICE FOR AMENITY BUILDING. PG 2846 21+00 SSMH-027 a (1) 3/4" IRRIGATION METER (PER PCU STD. DETAIL) (1) 1" RPZ BFP & ENCLOSURE (WATTS LF909 OR APPROVED EQUAL) 45 40 35 30 25 20 15 10 aN ,Ip 2" CLASS 200 CT .7. ��1 POLYETHYLENE DOMESTIC / SERVICE N 8" C-900 (DR-18 PVC WATER MAIN G 28 43 pAD = 28.80 WE 14 w, UTILITY NOTES: (NCAC 15A.02T.0305 / T15A.18C.0906) 1. WATER MAINS SHALL BE LAID SO AS TO PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 10 FEET FROM SEWERS. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, THE WATER MAIN CAN BE INSTALLED AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER, EITHER IN A SEPARATE TRENCH, OR IN THE SAME TRENCH ON A BENCH OF UNDISTURBED EARTH. 2. WHEN CROSSING A WATER MAIN OVER A SEWER, THE WATER MAIN SHALL BE LAID AT LEAST 18 INCHES ABOVE THE SEWER. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH JOINTS THAT MEET WATER MAIN STANDARDS. THE DUCTILE IRON PIPE SHALL EXTEND 10 FEET ON EACH SIDE OF THE CROSSING WITH A SECTION OF WATER MAIN PIPE CENTERED ON THE CROSSING. 3. CROSSING A WATER MAIN UNDER A SEWER. WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. 4. WHERE VERTICAL CLEARANCE IS LESS THAN 24" BETWEEN SANITARY SEWER AND STORM DRAIN, SANITARY SEWER SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 5. WHERE VERTICAL CLEARANCE IS LESS THAN 18" BETWEEN WATER MAIN AND STORM DRAIN, WATER MAIN SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 6. A MINIMUM VERTICAL DISTANCE OF 12" SHALL BE MAINTAINED BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF OTHER UTILITIES. PAD=27.45 -- 1)8"X6"MJTEE (1) FIRE HYDRANT HENNNIGS DRIVE ASSEMBLY I 1 50' PRIVATE R/W_ _ PG26.4. - III FM.- F-F FM 6 _-. f tadillffidari 26- SSMH-026 MY _,-- ., __ - ,,, ,... ___--- , - - „ __- 4" C-900 (DR-18) PVC FORCE MAIN (4' MIN. COVER) / S 3M! 3 HENNINGS DRIVE PLAN VIEW STA. 19+50 TO STA. 25+50 HORIZONTAL SCALE: 1 "=50' // / / / / /tir' / / / / S j ( <7 / �) 2 �\ IMPACT #2 / r1I^l/ry I I I I I I // //. 14 -/--j,`/ //7__- / - / / i- /� / / / / / / //�// V//7,e(/ 46 - ..,./, / 7 /ip-/ / % / / / // /, ,/ //� ,7 - - 1 r ---_. ry/ / #' PG/EG 28 42 PROPOSED WETLANDS /, CROSSING CULVERT (TYP.) ,/" �� / (SEE GRADING AND //// DRAINAGE PLANS) / / c MATCHLINE - SHEET C-5.7 PROPOSED SWALE (TYP.) ra (SEE GRADING AND DRAINAGE PLANS) c 17 M o d (1)8"x8"MJTEE (2) 8" MJ GATE VALVE GRAVITY SEWER NOTES; 1. ALL MANHOLES LOCATED WITHIN 50' OF WETLANDS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1.1. SEAMS SHALL BE EXTERNALLY TAPED / SEALED WITH WATERTIGHT MATERIAL. 1.2. ALL MANHOLE INTERIORS SHALL BE FULLY LINED WITH WATERPROOF COATING. 1.3. MANHOLES SHALL BE TESTED IN ACCORDANCE WITH ASTM C1244 "STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY NEGATIVE AIR PRESSURE (VACUUM) TEST PRIOR TO BACKFILL. 2. ALL SEWER PIPE MATERIALS, INSTALLATION, AND TESTING SHALL MEET WATER MAIN STANDARDS WHEN LOCATED WITHIN 50' OF WETLANDS. WATER MAIN NOTES; 1. ALL WATER MAIN SHALL BE INSTALLED A MINIMUM OF 5' FROM EDGE OF PAVEMENT. 2. NO VALVES, HYDRANTS, OR OTHER WATER MAIN APPURTENANCES SHALL BE INSTALLED IN THE SWALES. FORCE MAIN NOTES; 1. ALL FORCE MAIN SHALL BE INSTALLED A MINIMUM OF 5' FROM EDGE OF PAVEMENT. 2. NO VALVES OR OTHER FORCE MAIN APPURTENANCES SHALL BE INSTALLED IN THE SWALES. LI 8" C-900 (DR-18) PVC WATER MAIN 5 PRE SSMH-023 4" C-900 (DR-18) PVC FORCE MAIN (4' MIN. COVER) a. N N CO \116' tic ti J 28+00 f-ss MATCHLINE - SHEET C-5.7 i 28-87 ss s SSMH-024 (1) 4" MJ 90° BEND W Lu 0) EE tr) d 0 HENNINGS DRIVE PLAN VIEW MATCHLINE -SHEET C-5.6 STA. 25+50 TO STA. 28+77 HORIZONTAL SCALE: 1 =50 HIGH POINT STA. = 27+14.72 HIGH POINT ELEV. = 32.08 PVI STA. = 26+60.63 PVI ELEV. = 32.90 K = 43' 200' VC HIGH POINT STA. = 20+90.47 PVI STA. = 22+10.63o 2 co. M HIGH POINT ELEV. PVI STA. = 20+85.63 = 28.87 PVI ELEV. = 28.18 I +� "' c0� `� PVI ELEV. = 29.06 K = 65' I I K = 69' LOW LOW POINT POINT STA. ELEV. = 23+85.22 = 25.24 PVC STA =2 N II PVC STA.1= 2i+60.63 PVC EILEV. = 28.53 100 VC co CO w ¢ w - PVI STA. ELEV. = 24+10.63 = 23.90 100' VC co Lri co co LEVI. _ w O N STA. = 21+3 ELEV. = 28.. PVT STA.1= 24 co.o rA.= 25+10I63 -> II O_ + H Lu -1w• co w w PVC STA. 23I N I I w 1.07% 00 a �\\' PROPOSED GRADEEt I --- I-1--------- -- � ��0.85°% 0�� -A --;1-.70% �Mr \ 2.14h 6 0 = EXISTING GRADE �' ': �X1 B" MIN. C-900 96 LF OF 8 IN. PVC (DR-18) ` i� ,r� @ -0.40% IN. C -900 PV �' 8" C-900 (DR-18) DR-18) A -0.40% 8 IN. C-900 PVC WATER MAIN 291 F •F I PVC (DR-18 @ -0.40% e -- 155 TPVC L OF 8 IN. C-900 (DR-18) 175 LF OF 8 N. C-900 PVC (DR-18)° 1 I \ l �� @ -0.40% - 4" C-900 (DR-18) PVC FORCE MAIN © -0.40 /° �� �i� (4' MIN. COVER) I Cri N 9 N 9 I N 9 N O $ I I 2.20 (SSMH .22110 25. 2 V IN = 20.94 (SSMH VOUT=20;84I (C [3] 48" Q RCP (SMH .12-r NV IN3119.42 (SSMH INV OUT = 19;32 I SMH-02 3Mhi-00, 1 � V I -024 Nco + coO + co co� ^Oco -A.=20E M = 28. V IN = 2 V OUT INV IN = 2 -INV OUT = pN M-- N SSMH-038 STA. = 27+ RIM = 30.81 INV IN 25.9, INV IN 25.5E D-+- O N p CO N N -A. = 27 M=31.E V OUT I _ = I1I H IIII- HO =� (1) cn (/ I co (/ co cO (nIII co co d) �jM I� N N co0-)coO �I� Cd N N �M Cd N N 00 Cd N N �� Cd N N �M 00 N N coLf) �N I,:- N N f� inN �� O r N �N Lfi r N 0p coLfl �j00 Lfi Nisi N mac- N N CON OS Ns: N N coCfl a" �Lf� Cd N N �L(j CS COM O O DO CO L1� O O� N COCON CO CO M O O� 00 csj00 M I� O CO 19+50 20+00 21+00 22+00 23+00 24+00 25+00 HENNINGS DRIVE - PROFILE VIEW STA. 19+50 TO STA. 28+77 HORIZONTAL SCALE 1 "=50' VERTICAL SCALE: 1 "=5' 26+00 27+00 28+00 45 40 35 30 ( ) 8"x8" MJ TEE (2) 8" MJ GATE VALVE N r) Ii SSMH-038 PAD = 31.85 NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS 25 FORCE MAIN / WATER CROSSING. PROVIDE 18" MIN. SEPARATION AS REQ'D [TYP.] (SEE NOTE) 20 15 10 29+00 GRAPHIC SCALE 0 25 50 100 200 SCALE: 1 "=50' REVISIONS: NCDEQ PH 2 EC 101/28/22 N N W N N 0 WETLAND CROSSING REVISION CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 ENGINEERING, I N C. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: 1" = 50' DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL \\ oliii//// 028847 /o 41 `°/VG I NE\� ' ° � /,/ /Y G C L ', \\\\\ I 3/11/22 5•5 c PEI JOB#: 20178.PE SERVICE NOTE: 1. CONTRACTOR SHALL INSTALL ONE (1) 1-INCH WATER SERVICE PER LOT AND ONE (1) 4-INCH SEWER SERVICE PER LOT. MATCHLINE - SHEET C-5.7 P 1 z SSMH-018 (1) 4" MJ 90° BEND W 1 j /mi MATCHLINE - SHEET C-5.7 45 40 35 30 25 20 WATER/FORCEMAIN CROSSING. PROVIDE 18" MIN. SEPARATION AS REQ'D [TYP.] (SEE NOTE) 15 10 5 0 cv UTILITY NOTES: (NCAC 15A.02T.0305 / T15A.18C.0906) 1. WATER MAINS SHALL BE LAID SO AS TO PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 10 FEET FROM SEWERS. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, THE WATER MAIN CAN BE INSTALLED AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER, EITHER IN A SEPARATE TRENCH, OR IN THE SAME TRENCH ON A BENCH OF UNDISTURBED EARTH. 2. WHEN CROSSING A WATER MAIN OVER A SEWER, THE WATER MAIN SHALL BE LAID AT LEAST 18 INCHES ABOVE THE SEWER. IF CONDITIONS EXIST SUCH THAT THIS SEPARATION CANNOT BE ACHIEVED, BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH JOINTS THAT MEET WATER MAIN STANDARDS. THE DUCTILE IRON PIPE SHALL EXTEND 10 FEET ON EACH SIDE OF THE CROSSING WITH A SECTION OF WATER MAIN PIPE CENTERED ON THE CROSSING. GRAVITY SEWER NOTES; 1. ALL MANHOLES LOCATED WITHIN 50' OF WETLANDS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1.1. SEAMS SHALL BE EXTERNALLY TAPED / SEALED WITH WATERTIGHT MATERIAL. 1.2. ALL MANHOLE INTERIORS SHALL BE FULLY LINED WITH WATERPROOF COATING. 1.3. MANHOLES SHALL BE TESTED IN ACCORDANCE WITH ASTM C1244 "STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY NEGATIVE AIR PRESSURE (VACUUM) TEST PRIOR TO BACKFILL. 2. ALL SEWER PIPE MATERIALS, INSTALLATION, AND TESTING SHALL MEET WATER MAIN STANDARDS WHEN LOCATED WITHIN 50' OF WETLANDS. WATER MAIN NOTES; 1. ALL WATER MAIN SHALL BE INSTALLED A MINIMUM OF 5' FROM EDGE OF PAVEMENT. 3. CROSSING A WATER MAIN UNDER A SEWER. WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND 2. NO VALVES, HYDRANTS, OR OTHER WATER MAIN APPURTENANCES SHALL BE INSTALLED IN THE SWALES. THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. 4. WHERE VERTICAL CLEARANCE IS LESS THAN 24" BETWEEN SANITARY SEWER AND STORM DRAIN, SANITARY SEWER SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 5. WHERE VERTICAL CLEARANCE IS LESS THAN 18" BETWEEN WATER MAIN AND STORM DRAIN, WATER MAIN SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10' EITHER SIDE OF CROSSING AND STORM DRAIN SHALL BE RC PIPE. 6. A MINIMUM VERTICAL DISTANCE OF 12" SHALL BE MAINTAINED BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF OTHER UTILITIES. \ \ \ \ \ STORMWATER \ N POND N N N (1) 8"x8" MJ TEE (2) 8" MJ GATE VALVE STORMWATER "�- /- POND SSMH 017 �2— 13M 1=M 13M 13M Lti I I gyp, \ \ — — — — — �� — 14, N\\--:\\ \\\ � (1)8"X6"MJTEE j is / \ \ \ (1) FIRE HYDRANT \ ,- _ / i \ ASSEMBLY \ N\ 'I / �_\\\ N\\ \\ \ \ \\ (1) 8" MJ 22.5° BEND _ 7%�I� // / 8" C-900 (DR-18) //. PVC WATER MAIN // FORCE MAIN NOTES; 1. ALL FORCE MAIN SHALL BE INSTALLED A MINIMUM OF 5' FROM EDGE OF PAVEMENT. 2. NO VALVES OR OTHER FORCE MAIN APPURTENANCES SHALL BE INSTALLED IN THE SWALES. (1) 8" MJ 11.25° BEND LANGSTON ROAD 50' PRIVATE R/W ANT TAM �..�Vr.��` viN. \ SSMH-016 '-"Iir�� PROPOSED WETLANDS CROSSING CULVERT (TYP.) / / (SEE GRADING AND \ DRAINAGE PLANS) \ / I I III t Ik I I l\ \ Iil \ \ PROPOSED SWALE (TYP.) (SEE GRADING AND DRAINAGE PLANS) LANGSTON ROAD PLAN VIEW STA. 10+00 TO STA. 19+50 HORIZONTAL SCALE: 1 "=50' SSMH-015 2�^ STORMWATER POND 4" C-900 (DR-18) PVC FORCE MAIN — — (4' MIN. COVER) MATCHLINE - SHEET C-5.9 NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS PVI STA. = 11+25.00 PVI PVI STA. ELEV. = 15+50.00 = 27.08 o0 Q PVI ELEV. K = 60' = 25.98 K = 120 52' VC c - rn 0 100' VCLn o �� + xi� LOW LOW POINT POINT STA. =1 ELEV. = +12.34 21.°-kri oN o,� + u K u 7 co oN ° + .-N �� PVI STA. = 13+00.00 a `� u w ii Q> PVI ELEV}. K- = 19.58 38' it r w u > Lil EXISTING GRADE 0 > a v)w H <nw �w 250 VC - u)w a s p d a >> � a PROPOSED GRADE -\E o nr ---- fog%_____ ,` N ii 0.70% _ Qw - -- _ 5 c.� Lt U > fn w 1— H > — -- _ ��__--__ z- - --- _'� > a a >-� a a A. -----___ - 0 I I\4. \ 3 pp°lo 18" MIN. \ \ —■■■ / / - 4" C-900 (DR-18) PVC FORCE MAIN mmn...�— �,' o co in (4' MIN. COVER) , , \ ifs.:?"-- [2] 48" 0 RCP -0•001....— co�.� II ,/ 8" C-900 (DR-18) / —I PVC WATER ATER MAIN \!_ I � \ ,� w 2C6 LF OF 8 IN. C-900 PVC v 62 (DR-18) @ -0 40% i / 209 LF (TOTAL) OF 8 IN. ' C-900 PVC (DR-18) @ -0.40% 243 LF C5F 8 IN. C-900 PVC (DR-18) @ -0.40% 1i 1 WATER/STORM CROSSING. PROVIDE 340 LF OF 8 IN. C-900 I PVC o _- `� NECESSARY BENDS FOR FULL PIPE AT 18" (DR i8) @ 4 0.0% SEPARATION CENTERED AT CROSSING. PROVIDE 20 LF DIP (40 LF TOTAL) (PRESSURE CL. 350) FORCEMAIN/STORM CROSSING. SANITARY MAIN CENTERED 36" 0 RCP PROVIDE NECESSARY BENDS FOR AT EACH CROSSING 18" MIN SEPARATION. 0 0 a 0 2 (ssr (SS .54 14.2 IN IN=13.501 NV OUT=13. .431 12.21 00 O N. O (0±o14) OWN_ O. 2 2 2 2 II r± — > > > u) u) u) u)u)aZZZ cn co�E H _ u) O) N rn co 00 00 N N 00 co I` I- N N co N Ln 6 N N N I,- O Oi Lf) .- N N CO M Ln M .- N O O I: N N O O O O (...71N CO a0 N N N (.fl 4 N N N CO O © (D 4 N N I� CO Lf) (D 6 N N I` I` CO N N N Cfl O I` N N CO CO ~ Lf) N N Cr) O `- Cp 00 N N CO N 00 00 N N Cr) Cfl co 00 00 N N CO O - 00 O N N Cr) CO Ln O O N N 9+50 10+00 11+00 12+00 13+00 14+00 15+00 LANGSTON ROAD - PROFILE VIEW STA. 10+00 TO STA. 19+50 HORIZONTAL SCALE: 1 "=50' VERTICAL SCALE: 1 "=5' 16+00 17+00 18+00 19+00 45 40 35 30 25 20 15 10 5 0 19+50 GRAPHIC SCALE 0 25 50 100 200 SCALE: 1 "=50' REVISIONS: NCDEQ PH 2 EC 01/28/22 N N W N N 0 WETLAND CROSSING REVISION CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 ENGINEERING, I N C. 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: 1" = 50' DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL oolHH/ it °° �S° / ', pF ° ; 028847 o°° �/]/GIN'�'.�� /,/ //Y G.C L INS111\0\\\\\\ I 3/11/22 C 5•8 PEI JOB#: 20178.PE Appendix C. Retaining Wall Information SHEET 1 OF 8 REV. CERTIFICATE rC-2446 T(704) 483-5225 Fax: (704) 483-5466 4090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©belIsou th.net ................... ''•. : SEAL 19258 or ~IIKL_J P pIpI� INDEX OF DRAWINGS: Sheet 1 of 8: Sheet 2 of 8: Sheet 3 of 8: Sheet 4 of 8: Sheet 5 of 8: Sheet 6 of 8: Sheet 7 of 8: Sheet 8 of 8: Cover Sheet Plan View Plan View Plan View Elevation Views (Wall 1, 2, 3, 4) Elevation Views (Wall 5, 6, 7, 8) Details Notes COVER DESIGNER: MICHAEL KISER PE Bridgewater Landing RETAINING WALLS Pender County, NC DESIGNER DRAWN MLK SCB DATE 3/29/22 imp. DATE 3/29/22 imp. DATE DATE CONSULTING ENGINEERS & PLANNERS N NO. REVISIONS DRN DATE CHK DATE SCALE SEGMENTAL RETAINING WALL REV. SHEET 2 OF 8 R EV. EDENS LANE SHT. C-4.1 SHT. C-4.2 SHT. C-4.3 SHT. C-4.4 KEY MAP NOT TO SCALE 1 1 SEE SHEET C-4.0 FOR SWALE SCHEDULE LEGEND: 16- - -- EXISTING CONTOUR 16 PROPOSED CONTOUR PROPOSED SWALE PROPOSED RETAINING WALL (BY OTHERS) NOTATION: DI = DROP INLET PG = PROPOSED GRADE EX = EXISTING GRADE HP = HIGH POINT ELEVATION LP = LOW POINT ELEVATION SW = SIDEWALK ELEVATION TW = TOP OF WALL ELEVATION BW = BOTTOM OF WALL ELEVATION CULVERT #2 [54 LF] [2] 18" RCP CL IV PIPE INV.UP=26.20 PIPE INV.DWN=26.00 a JAMES R HALL II PIN: 4214-06-6482-0000 DB 634, PG 92 PB 21, PG 36 POND 1 INLET UJ RIP -RAP APRON LL1 , DRAINAGE EASEMENT (TYP.) 1 I 78 1 1 1 1 1 DI-2.1 L DRIVEWAY CULVERT #2 [60 LF] 24" RCP CL III (WI FES) [4.8" FILL AT BOTTOM] PIPE INV.UP(NW)=26.10 PIPE INV.DWN(SE)=25.85 CULVERT #5 [52 LF] [3] 24" RCP CL IV PIPE INV.UP=25.60 PIPE INV.DWN=25.40 STORM SCHEDULE: HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-15-0 9 74 - 0000 DB 4725, PG 1766 RIP RAP APRON - - (TYP. - SEE DETAIL) r PROPOSED SWALE (TYP.-SEE DETAIL) POND 1 EME▪ RGENCY SPILLWAY [SEE DETAIL] MANUFi\CTURER TW 24.0' BW 24.00 ► 24. ► POND 1 OUTLET STRUCTURE [SEE DETAIL] BRYAN TRAVIS HALL PIN: 4214-15-3 74 9- 0000 DB 1858, PG 210 ERICA LEWIS PIN:4214-15-4757-0000 { - D8 4167, PG 220 ID LOD ` LOD LOD LOD LUU - -� - r � N. \ , ' :� + ' PAD 27.00 �` PAD 25.50 - � �� ' 1 + �' ` _ _ PAD 26.00 - .gyp /f ss- I f L `- \ ` ( - 'IS 25.0 41 ' 40 i \_� /� 39 \ \ 0 \ \ \ ...If, %Fr ' ,' Tw s o "' r BW 25.00 WETLAND CROSSING #2 [50 LF] �� �� ;� � BW .. I TW 25`50 . [2] 24" RCP CL III (OR HDPE) ` ` ` _ 1 BW 24.00 [5' FILL AT BOTTOM] / ` .2 BW 18 PIPE INV.UP=20.50 �ae \ �.. PIPE INV.DWN=20.30 V l_ •� WAL 18 ` �'' ` 5W1 20 : POND 1 RIP -RAP APRON [SEE DETAIL] " , T _ _1 \\ ___„,_ , POND1 } � SKIMMER ��4SSS1 [SEE DETAIL] 2` \ •//_ I _ - , - f S , III /,) ) i ,telirr ry p HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-15-7760-0000 DB 4725, PG 1766 .LJiQi \E ■ • 1 PRIVATE DRIVEWAY CULVERT CROSSING [31 LF] 12" RCP CL. III PIPE INV.UP=23.00 PIPE INV.DWN=22.00 PRIVATE DRIVEWAY CULVERT CROSSING [44 LF] '12"RCP CL. III / PIPE INV.UP=21.00 PIPE INV.DWN=20.00 .00 .50 q FM7.00 War n� .00 22.0► 14• �5t BW19.00, BTWW 19. � 19.00 SILT FENCE (TYP.-SEE DETAIL) TE ALL STORMDRAINAGE PIPING CAN B rr'HER IDPE OR RCP, IF MEETS AND CON SPECIFICATIONS ( (4. � \I\�/ Upstream Node Downstream Node Diameter (In) Upstream Invert Downstream Invert Pipe Length (ft) slope %j Upstream Rim Elev Downstream Rim Elev MH-4.1 FES-3.1 36 20.13 17.00 37 8.51 31.03 20.00 01-2.1 MH-4.1 36 20.36 20.13 80 0.30 26.00 31.03 1 7 \ 1 J L MORRIS ENTERPRISES P1N:4204-95-5947-000L DB 1089, PG 274 PB 22, PG 39 \ 1 SEE SHEET C-4.5 FOR AMENITY GRADING PLAN \ kSTRUCTED WITH QED PER 22❑� BW 20.00 RETAINING WALL (BY OTHERS), TYP. • 7/ 2 BEGINS 7, 7- 0 TW 22. BW 14.2t WETLANDS \ ------- .--;----...„--- ;;::1,--,--, --7---- J / WETLAND CROSSING #3 [52 LF] 48" RCP CL II [10" FILL AT PIPE INV.UP PIPE INV.DW ill // 1 WETLAND CROSSING #3 [52 LF] • [2] 48" RCP CL III [SECONDARY] PIPE INV.UP=15.20 PIPE INV.DWN=13.80 4 BEGINS 1 GRAPHIC SCALE 0 25 50 100 200 SCALE: 1 "=50' Fj 1 �I 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 Know what's below. Call before you dig. 7 z REVISIONS: NCDEQ PH 2 EC 01/28/22 N eg N o WETLAND CROSSING REVISION CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 GRADING & DRAINAG Nt PLAN BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIMINARY LAYOUT: FINAL DESIGN: RELEASED FOR CONST: DRAWING INFORMATION DATE: 09.08.21 SCALE: DESIGNED: ASR DRAWN: ASR CHECKED: TGC SEAL ow IC1ARD4./f .", . 028847 r>Th,••.. 5G'' 3/77/22 C-4. 2 PEI JOB#: 20178.PE CERTIFICATE rC-2446 (704) 483-5225 Fax: (704) 483-5466 4090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©bellsou th.net ��''••••C A• R ••••. SEAL 19258 . c.,-/� NGINE�•\,--•: NOT TO SCALE NOTES: • THIS SHEET IS NOT A CERTIFIED DOCUMENT OF WORLDWIDE ENGINEERING GEO. DIV. INC.. GRADING PLAN IS THE PROPERTY OF THE CIVIL ENGINEER OF RECORD AND IS SHOWN FOR REFERENCE TO VIEW WALLS. LOCATE WALLS USING CIVIL ENGINEER'S DOCUMENTS ONLY. • 2018 IBC CODE REQUIRES SEGMENTAL RETAINING WALLS TO BE CERTIFIED AT THE END OF CONSTRUCTION. THE CERTIFYING FIRM SHALL BE UNDER CONTRACT AND ONSITE AT THE BEGINNING OF CONSTRUCTION. PLAN VIEW DESIGNER: MICHAEL KISER PE Bridgewater Landing RETAINING WALLS Pender County, NC DESIGNER DRAWN MLK DATE 3/29/22 Imo. S C B NE 3/29/22 INSP. DATE DATE CONSULTING ENGINEERS & PLANNERS NO. REVISIONS DRN DATE CHK DATE SCALE SEGMENTAL RETAINING WALL REV. SHEET 3 OF 8 REV. e N N EDENSLANE CV � o mry N ry c 11111111111 I I I lfl:i,.l.-.- _ :•:; < =::=::::::::•:::::::; SHT. C-4.1 SHT. C-4.2 SHT. C-4.3 SHT. C-4.4�. +i KEY MAP , I I HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST I PIN:4214-25-3147-0000 I NOT TO SCALE +j� DB 4725, PG 1766 _� • �� 7EC::, TYP. \� �a� �� Z./ ix z ` LOD Lap LOD W W T r CT'-'\ \ 'r SEE SHEET C d.0 FOR SWALE SCHEDULE rslo _] OD —tom d— LOD LOD LOD r� \� �. - 2I W o [//il / \-_,\��`�LEGEND: 3EVISIOi CDEQ PH 2 WETLAND CR, 7� �� ' �� -- y�3 NNE, LLC 1RY ROAD, SUITE 1 NC 28451 , i5 EXISTING CONTOUR I N I 1 I " L �� � ' \ 6 PROPOSED CONTOUR PROPOSED SWALE I � ' � _- �' I � I � � I 11 �� � 7/� � '/ ' PROPOSED RETAINING WALL (BY OTHERS} /_IIV')IY ��� i �1�+i j —� POND 3 EMERGENCY SPILLWAY �sy / _^�� x 192 ` +, [SEE DETA€L]av �! / @,) POND 3 INLET ` \ ` RIP -RAP APRON DI =DROP INLET yy , yl ::tS:�. te��� � I PG = PROPOSED GRADE � � 11 �St:�a \ � � Ex = EXISTING GRADE I — ` r{ 1 t'; ` l , t ", HP = HIGH POINT ELEVATION CD, — [n J , N [ ] LP = LOW POINT ELEVATION SW = SIDEWALK ELEVATION ' + � .r'� e 23 .ss -0: +• , , ae , 1' \ 0 `�' 11-1 r F� a TW = TOP OF WALL ELEVATION 2e y� � SS S ' a , •I ' Q V BW = BOTTOM OF WALL ELEVATION r iry� POND 3 OUTLET , \ STRUCTURE ~ ix z j ❑ [� 1�1 3 [SEE DETAIL] ^ ' �► .��r CULVERT #7 [50 LF] [2] IN RCP CL I0 PIPE iNv.uP=z5.2 ALE 31 I�ryry N ry N i� ry 'Fr i { N ` Jy w t l WET POND 3 i l `E 1 r l--1 i- z W WPQ J ❑ -= �� -- PIPE INVAWN=25.DD - i- - ORAMOUNTE N G 1 N E E R 1 N G, 1 N C, 122 Cinema Drive Wilmington, North Carolina 28403 '10) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 r ♦ ' U Ili I w ' �[•J r. - � { i it I l r17 :;- SKIMMER [SEE DETAIL] i� � � =�� CI��� 1- APRON WETLANDS ' = POND 3 RIP -RAP [„] [SEE DETAIL) I / WETLAND CROSSING #4 [5D LF] LL.] F. FILL AT BOTTOM] / 1 1 \ 36" RCP CL III [PRIMARY] } PIPE INV.DWN=185 %.\u J �f r� J ' I SEE DETAIL) .�� (TYP. - CO j ' � 18.00 f; , \ POND 4 RIP-RAP -�� 1 RETAINING WALL APRON •+ w Z ' ` �� / w a BW 18.00 ,;j (BY OTHERS). �� , C [SEE DETAIL] -• _ TYP.` \ u - r Z J �_ i' �� TW 19.Qi �� %WETLAND IMPACT FOR ` �%' � _1 _ U I� QI f rym� O\ BW 11,71. Q ,� .• , BEGINS i ROAD AND CULVERT ` F POND 4 OUTLET = INSTALLATION. TYP. _�� rs� STRUCTURE 4.,U r� �� [SEE DETAIL] 1 WETLAND CROSSING #4 [50 LF] �sa���� I W Plml 1 1 _::,.�ON4�SKMMR�PIPE 26 27 INV.UP=24.75 PIPE INV.DWN=24.25 #86LF] 5 i e a�®►_,�. INV.DWN=15.35 �� ��A ��. .;•tip 4•; ' •• . ofCULVERT �.�'�`�"°�+/rh '‚4.; ,PIPE 5} BW 16.Q(1 / , a. i � ry I 1 1 I j�. r,'N..1 1 ' GE PLAN 1G : CAROLINA 2J� PROPOSED SWALE���. {TYP. SEE DETAIL] 5y '� "9 `ti . ''�� -��q� -J �'' I. TW .00 19.0� �� , �' , 141046. ' .P~ If 5WA 5 y '�: POND 2 RIP -RAP ' TW � \ j �I ss APRON �1 Ti :.• DETAIL] ` f FM ■ , FM — - [SEE • L J! / f � � '� \ �� . In-• n 7o w •/a! SS —� = �� POND 2 OUTLETr ` 1 } } ' '� �► �� f H F^i SS S .1:,' SS , 50'RIW (PRIVATE) �� ._ —� ,• ' STRUCTURE y SEE DETAIL] ,, `, I �I n Yi POND 2 INLET WET POND 2 H-1 RIP -RAP APRON _ g 1 �j J / 'e 1 r ,,,,............- Li. g / , / :r '-'"--. \ _,t 4, z 0 0 $ \ POND 2 EMERGENCY f , , 1 ' 2s -� � , �,..... , -{ SPILLWAY t -� FM rah [SEE DETAIL] `J Cf:FiF \ ,,,- --------T ` wETLANOs \, \ I /e-2 Q `.J = H rN n�u�i v�i V � e9a _ _ _ _ aea Doi ` ool ` ❑r), n o o, ao, ❑m o, e9� e� _ = aea = - .- = = e9� - J L MORRIS ENTERPRISES I c_--I PIN: 42D4 95 5947 OflOL Q � n1i u-CO —U zLu �a <D- ❑ aOwono NOTE EITHER MANUFACTURER ALL HDPE STORMDRAINAGE OR RCP, SPECIFICATIONS IF MEETS PIPING AND CAN CONSTRUCTED BE CONSTRUCTED PER WITH Z C VD W 0.4101 SEAL illi� e,/ _,.\Z-H ..s """�� ,,,% : °�a$ �, ".N•*R- ',:I- 3/11/22 I— GRAPHIC SCALE Know what's MOW. rJ 0 25 50 100 200 CaII before you dIq ---++ , 4.3 i �1 1 :P 1"=50' PEI ]OB#: 20178.PE r�[r = 4 /3401 CERTIFICATE —2446 04. \-\secARo f..,, NOT TO SCALE P LAN VIEW WORLDW IDE (� 04) 483-5225 . NOTES: •.•�o.�oFEss•1oti...., 2 Bridgewater Landing ,� Fax: "V (704) 483-5466 ; Q <.. 2 '14... tf v SEAL = 3IZJ1 • THIS SHEET IS NOT A CERTIFIED DOCUMENT OF WORLDWIDE ENGINEERING GEO. DIV. INC.. GRADING PLAN IS THE PROPERTY OF THE CIVIL RETAINING WALLS 4090 N. NC HWY 16' : 19258 ENGINEER OF RECORD AND IS SHOWN FOR REFERENCE TO VIEW WALLS. LOCATE WALLS USING CIVIL ENGINEER'S DOCUMENTS ONLY.�''�- 4k A i A P.O. Box 2189 DENIER, NC 2803� ? �.. • 2018 IBC CODE REQUIRES SEGMENTAL RETAINING WALLS TO BE CERTIFIED AT THE END OF CONSTRUCTION. THE CERTIFYING FIRM SHALL BE Pender County, NC ENGINEERING _ • ::' �' .'•`�' �`• UNDER CONTRACT AND ONSITE AT THE BEGINNING OF CONSTRUCTION. o��� MLK cot 3/29/22 , DATE www.WWEgeo.com ,,,,••yA DESIGNER: MICHAEL KISER PE . DRAWN SCB NE 3/29/22 DATE CONSULTING ENGINEERS & PLANNERS N LK iser© elEl EILN ;.',,, •••••••••••.. NO. REVISIONS DRN DATE CHK DATE SEGMENTAL RETAINING WALL SHEET 4 OF 8 REV. EDENS LANE KEY MAP NOT TO SCALE w w w • w Z U F- 1 1 1 1 WETLANDS ' WET POND 4 ' [SEE DETAILS] 1 1 1 1 1 1 POND 4 EMERGENCY SPILLWAY [SEE DETAIL] DRAINAGE EASEMENT [TYP. ) POND 4 INLET R P-RAP APRON [10'x20'1 J L MORRIS ENTERPRISES P1N:4204-95-5947-000L DE 1089, PG 274 PB 22, PG 39 SEE SHEET C-4.0 FOR SWALE SCHEDULE • PAD = 28.90 LEGEND: ---16--- 16 1 EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SWALE PROPOSED RETAINING WALL (BY OTHERS) NOTATION: HILDA EDENS, TRUSTEE OF THE EDENS LIVING TRUST PIN: 4214-25-3147-0000 DB 4725, PG 1766 POND 5 INLET RIP -RAP APRON [10'X20'] PAD = 26.60 DI = DROP INLET PG = PROPOSED GRADE EX = EXISTING GRADE HP = HIGH POINT ELEVATION LP = LOW POINT ELEVATION SW = SIDEWALK ELEVATION TW = TOP OF WALL ELEVATION BW = BOTTOM OF WALL ELEVATION PAD = 25.25 PROPOSED SWALE (TYP.-SEE DETAIL) STORM SCHEDULE: Upstream Node Downstream Node Diameter (In) Upstream Invert Downstream Invert Pipe Length (ft) Slope (%) Upstream Rim Elev Downstream Rim Elev MH-8.4 FES-8.1 18 20.43 19.50 220 0.42 26.27 19.50 DI-8.2 MH-8.4 18 20.50 20.43 25 0,30 24.75 26.27 DI-8.3 DI-8.2 18 21.50 20.50 54 1.85 24.75 24.75 CULVERT #9 [54 LF] i \ [2] 12" RCP CL IV PIPE INV.UP=20.50 PIPE INV.DWN=20.30 19 PAD = 25.65 / • ` \N /7/ " 1 / / 1 J L MORRIS ENTERPRISES PIN: 4214-23-2291-0000 DB 3362, PG 68 NOTE ALL STORMDRAINAGE PIPING CAN BE CONSTRUCTED WITH EITHER HDPE OR RCP, IF MEETS AND CONSTRUCTED PER MANUFACTURER SPECIFICATIONS 1 ' 1 sfl , PG :,21 P 18.3 SS POND 5 INLET RIP -RAP APRON [10'X20'] 8 BEGINS 7 BEGINS POND 5 SKIMMER [SEE DETAIL] BW14.00, \/ TW 12.00 • 1 ,,tt��� BW 12.00 • TW 'I;.00 BW 14.00 --� TW 1 •.00 BW 16.00 POND 5 EMERGENCY . SPILLWAY [SEE DETAIL] I POND 5 RIP -RAP APRON L` [SEE DETAIL] I - f ,.�, SILT FENCE, TYP. [SEE DETAIL] GRAPHIC SCALE 0 25 50 100 WETLANDS 200 SCALE: 1 "=50' Know what's below Call before you dig. N 6 u] z INCDE4 PH 2 EC 0 rn >z CLIENT INFORMATION: EDENS LANE, LLC 60 GREGORY ROAD, SUITE 1 BELVILLE, NC 28451 E N C3 N E E fz N C3 1 N 1, 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 GRADING & DRAINAGE PLAN BRIDGEWATER LANDING TOPSAIL TOWNSHIP PENDER COUNTY, NORTH CAROLINA PROJECT STATUS CONCEPTUAL LAYOUT: PRELIFA1NARY LAYOUT_ FINAL DESIGN: RELEASED FOR CONST: • DRAWING INFORMATION DATE 09,08.21 SCJ; F: 7" ' DESIGNED ASR DRAWN: ASR CHECKED TGC SEAL 0 141ililli/� 028847 �'Ci'' : 'GIHEQ .�� = 3/11/22 C-4.4 PEI JOB#: 20178.PE o F CONSULTING ENGINEERS & PLANNERS CERTIFICATE rC-2446 04) 483-5225 x: (704) 483-5466 090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©bellsouth.net .•••••• C A R ' •••. �••FoESSL • OioN••y•' SEAL 19258 • NOT TO SCALE NOTES: • THIS SHEET IS NOT A CERTIFIED DOCUMENT OF WORLDWIDE ENGINEERING GEO. DIV. INC.. GRADING PLAN IS THE PROPERTY OF THE CIVIL ENGINEER OF RECORD AND IS SHOWN FOR REFERENCE TO VIEW WALLS. LOCATE WALLS USING CIVIL ENGINEER'S DOCUMENTS ONLY. • 2018 IBC CODE REQUIRES SEGMENTAL RETAINING WALLS TO BE CERTIFIED AT THE END OF CONSTRUCTION. THE CERTIFYING FIRM SHALL BE UNDER CONTRACT AND ONSITE AT THE BEGINNING OF CONSTRUCTION. DESIGNER: MICHAEL KISER PE REVISIONS DATE CHK DATE PLAN VIEW Bridgewater Landing RETAINING WALLS Pender County, NC MLK DATE 3/29/22 iNsp. SCB Dmme 3/29/22 ilrsr. SEGMENTAL RETAINING WALL WALL DROP LE #1 WALL P OF LE #2 SHEET 5 OF 8 R EV. 28.0 26.0 24.0 22.0 20.0 18.0 16.0 BEND (STA 0+05) CAPS (SEE DETAILS) PIPE PEN INVERT ELEV. 20.5' PIPE PEN PIPE 24" DIA. INVERT ELEV. 20.5' (STA 0+21) PIPE 24" DIA. (STA 0+18.50) BEND (STA 0+43) I I 1 Z 0 O O + O 6.5' Ji 1 1IIIIIII 1 I I I FOOTING (SEE DETAILS) 0 O N + 0 6.5' 6.5' s 0 O O + O 6.5' 6.5' MINIMUM ELEVATION FOR TOE OF WALL 1 1- 1 1' I 1_f 1n N + O 6.5' 5.5' Q cn 26.0 - 24.0 - 22.0 - 20.0 - 18.0 16.0 14.0 12.0 10.0 CERTIFICATE Ise -2446 04) 483-5225 x: (704) 483-5466 4090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©bellsouth.net ,,,,,.$01111.0100.CA I'••I • SEAL r. • 19258• . \ ->.�NG I1,1E5':c<"-,- y Q cn GEOGRID EMBEDMENT LENGTH 24.0 - 22.0 - 20.0 - 18.0 - 16.0 - 14.0 - 12.0 - O O + O 6.5' Q cn BEND (STA 0+12) - 28.0 - 26.0 24.0 22.0 - 20.0 - 18.0 - 16.0 WALL D OFIL PIPE PEN INVERT ELEV. 15.2' PIPE 48" DIA. (STA 0+45) PIPE PEN PIPE PEN INVERT ELEV. 15.2' INVERT ELEV. 15.2' PIPE 48" DIA. PIPE 48" DIA. (STA 0+54) (STA 0+63) I I I I I Ty1 y 1 1 1 1 1 1 111111111 I I I I I II II 1 1 1 1 1 1 I LI 11 11 y III I I I I I I I I I I I I I11111111111111 I I I I I I I I I I I I I 1 + 6.5' 0 6.5' O + 6.5' 0 9.0' 1 O O ro + 9.0' 41•19•-MIF NEM MPMM II II IIIIIII III 1 y 1 1 1 17 I \` NEM 1 I Vvvat� 1 28.0 26.0 24.0 22.0 20.0 18.0 - 16.0 - PIPE PEN INVERT ELEV. 20.3 PIPE 24" DIA. (STA 0+14) PIPE PEN INVERT ELEV. 20.3' PIPE 24" DIA. (STA 0+16.5) I I I 1 I 1 I I l y 1 yl 1 1 1 I� 1 1 1 I li I I 1 1 -I 1 �I 1 1 �I I I 11� 1 y 1 I I� 11 I I I �1 ,� i•/ I *I 1 �- I 1 I 1 1 �ii�ii ; I I� L1 I I I_r ,.I 1 1 I I I I I L I 1 1 1 1 1 O O O + O 6.5' 0 O 6 O + O 6.5' 6.5' 0 Ln 10 N + 0 6.5' 6.5' cn GEOGRID EMBEDMENT LENGTH I II I IJIIIIIIIIIIILI I I I I I I I I I I I I I I I 11 Is 1 1 I i I l l y l 1 yl 1 � 1 1 1 1 I I ▪ I I l 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i 9.0' 9.0' O N + 9.0' 9.0' 1 1 1 1 1 1 1 1 1 1 1 Ln h 10 N + of 6.5' GEOGRID EMBEDMENT LENGTH WALL PROFILE # PIPE PEN INVERT ELEV. 13.8' PIPE 48" DIA. (STA 0+55) BEND (STA 0+14) PIPE PEN INVERT ELEV. 13.8' PIPE 48" DIA. (STA 0+64) PIPE PEN INVERT ELEV. 13.8' PIPE 48" DIA. (STA 0+73) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1- 1 1 1 d BEND (STA 1+02) I I +.•+ +4+-6* - 24.0 - 22.0 - 20.0 18.0 - 16.0 - 14.0 - 12.0 cn I I I I cn - 28.0 - 26.0 24.0 22.0 - 20.0 - 18.0 - 16.0 6.0' 0 O O O i l l y 1 I y1 I I I I I I I I I I I y 1 I y 1 I I, I I ; \; 1�� I l l l l l l -I I I 1-1 I I I- I I I I I I I I I I I 1\ !�- Z I I 1 1 1 1 1 1 1 1 1 1 ,I I 4- I I I� 1 �� /rGi�\�_� GEOGRID EMBEDMENT LENGTH �\1MO°--Wr�-�N \, y I ; \, I I l y 1 1 y l 1, 1 I I I I IJr I 11 1 1\ ,�1 11 I I 1 I1 1 I I I I1 I 1 1 1 1 1�1 1 1� I -- 0 O + 8.5' O 10.0' 10.0' Z I I I r --- + 10.0' U) 8.0' LEGE\ 3 STA. 1 +01.00' Mirafi 3XT 0 10 O + 7.0' 6.5' 0 3' 6' 12' O + 6.5' - 26.0 - 24.0 - 22.0 - 20.0 18.0 - 16.0 - 14.0 - 12.0 - 10.0 NOTES: 1. THE REINFORCED BACKFILL SHALL BE A CLEAN SAND AND IS RESTRICTED TO HAVING A MAXIMUM FINE CONTENT OF 20% PASSING THE #200 SIEVE, A MAXIMUM LIQUID LIMIT OF 30 AND A MAXIMUM PI OF 10. ELEVATION VIEW DESIGNER: MICHAEL KISER PE Bridgewater Landing RETAINING WALLS Pender County, NC DESIGNER DRAWN MLK SCB DATE 3/29/22 itisp. DATE 3/29/22 INSR. DATE DATE CONSULTING ENGINEERS & PLANNERS HORIZONTAL SCALE 1" = 6' NO. REVISIONS DRN DATE CHK DATE SCALE SEGMENTAL RETAINING WALL REV. WALL DROR L SHEET 6 OF 8 R EV. 20.0 - 18.0 - 16.0 - 14.0 - 12.0 - 10.0 - 08.0 - 22.0 - 20.0 - 18.0 - 16.0 - 14.0 - 12.0 - 10.0 - 08.0 - 06.0 - 22.0 20.0 18.0 16.0 14.0 12.0 10.0 08.0 BEND (STA 0+08) 1 1 1 I IJ- 1 CAPS (SEE DETAILS) I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I- I I- 1 I -1 I I I I I "I I I I "I I I I" I I" I PIPE PEN INVERT ELEV. 10.85' PIPE 36" DIA. (STA 0+48) I I I I I I I I I L I I I I -I I I I" I I "I I I I "I I 1 l 1 PIPE PEN INVERT ELEV. 15.6' PIPE 48" DIA. (STA 0+67) PIPE PEN INVERT ELEV. 15.6' PIPE 48" DIA. (STA 0+74) JIIIIIIIII IIII1 1 � I I I" I I 1 1 1 I M I I 7I I 1 I I" I I" I I- I I I I" I I I I I I 1 I // ZIP 1 r 1 I "1 I I I 1 \ I I 1 1 1 \1111111/// 1 / - \ 111111111111111E 1 1 1 1 1 1 1 1 I r I r I 1- I 1- I I" 1 I -1 I I I I" I I I I" I I I I FOOTING -IL -I (SEE DETAILS) GEOGRID EMBEDMENT LENGTH 1 I" I I + 8.0' 10.5' BEND (STA 0+25) 1" 1 I I 1 err -I !I T I I Z I I I I I I I I I I I I - /y N 06 I ) + 10.5' 10.5' PIPE PEN INVERT ELEV. 15. PIPE 48" DIA. (STA 0+68) MINIMUM ELEVATION FOR TOE OF WALL 10.5' PIPE PEN 6'INVERT ELEV. 15.6' PIPE 48" DIA. (STA 0+76) N 10 + 10.5' 10.5' STA. _0+67.00' I 1 10.5' WALL PROFILE #6 I I I I I I I I I / 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I PIPE PEN INVERT ELEV. 10.6' PIPE 36" DIA. (STA 0+68) 1 1 I I I I+ I ' 1 0 O + 0 9.0' in N co + 9.0' 0 Ln cO co 7.0' ir 0 10 O + 0 6.5' in N O + 6.5' 6.0' - 22.0 - 20.0 - 18.0 16.0 - 14.0 - 12.0 - 10.0 - 08.0 BEND (STA 1+21) 1 1 I I I 1 1 F 1 1 1 1 1 1 1 I I� I I I I L I I I I I I I I I I I I I I I I I ' I '_I ' 1 ' �' 1 �' 1 ' 1 1l 1 1 1 1 y1 1 1 ,/�\\,\ �, ,1 ' 1 '� ' 1 ' �' 1 ' 1/' 11111111 I� ' ' ' 'I ' '_I ' ' �' ' �' ' I I� I I y1 I I, I I I I I I �1 1 I 1� 1 + 1 I 1 ��.�_�.�iiiiiiiiiiiiir■�iliiiiiiGiiiiiiiiiiiiliiiiiiii'�iiiiiiiiiliili�■ \ O O O + O 5.5' Q WALL DROF BEND (STA 0+11) BEND (STA 0+18) I 1 I I 1 1 I* I 11 I" L I L/ 1 L 1 1 1 L 1 1 l 1 l �I it II I I " I I I I " I I L Z O O O O + 5.5' 0 6.5' Q GEOGRID EMBEDMENT LENGTH I� I II I �I I I I I I I I I � I I I �� 1 1 �l 1 1 �I. I I I L I 11 I I I 1 I J -f I� Jr. i� �.� ■ 1- T I I I 1I I I I1 -+- I ' I 1 1 1r O O 10 N + 6.5' 0 8.5' O O O + O 6.0' 1L 8.0' in O + 0 8.0' 8.0' Q GEOGRID EMBEDMENT LENGTH CERTIFICATE Ise -2446 04) 483-5225 x: (704) 483-5466 4090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©bellsouth.net in N M + O 8.0' 1 6.5' ,,,,,.$.111111.0100.CA I'•�I • SEAL • 19258 • In + O 6.5' Q - 20.0 - 18.0 16.0 14.0 - 12.0 10.0 - 08.0 O O N + 8.5' Q 20.0 - 18.0 16.0 8.5' 14.0 T I 12.0 - 10.0 - O O + O 6.0' STA. J0+49.00' 9.5' I I L1 I 10 10 + O �I I I 1 I I \\ 12.0' 1 1 1 / M1 I 1 l 1 I I I L� fi I I"I I T 1 12.0' 12.0' I I I I I I I I I I I I" L-.L ir + 12.0' 1 1 1 1 1 "I- 1 I" I I - I I I "1 I 10.0' 1_ O O r7 co + 10.0' 0 8.0' Q 8.0' WALL PROFILE #8 I I I I I I I I - -1 I I I I I -- --Ir 1 1 BEND (STA 0+57) I 1 1 1 1 1 1 i I -1-- 1 O O 4 O + 8.0' 6.5' Q BEND (STA 0+65) 1 1 1 1 1 J--1 I I I "1 I 6.5' 5.5' Q s- Q - 22.0 - 20.0 18.0 16.0 - 14.0 - 12.0 - 10.0 - 08.0 - 06.0 1 I 1 I 1 1 1 1 1 1 1 1 1 1 T-I ▪ I -I- ▪ - - - I- I J 1 l 1 I I" I I 6.0' h O I ) + O 6.0' 1 6.5' N + O 6.5' 1 6.5' I 6.5' 1 1 h 06 N + O 6.5' 1 6.0' I. I 6.0' in 06 O + O cn GEOGRID EMBEDMENT LENGTH U) 10 LEGE\ 3 Mirafi 3XT 0 3' 6' 12' 10 - 20.0 - 18.0 - 16.0 14.0 - 12.0 - 10.0 NOTES: 1. THE REINFORCED BACKFILL SHALL BE A CLEAN SAND AND IS RESTRICTED TO HAVING A MAXIMUM FINE CONTENT OF 20% PASSING THE #200 SIEVE, A MAXIMUM LIQUID LIMIT OF 30 AND A MAXIMUM PI OF 10. ELEVATION VIEW DESIGNER: MICHAEL KISER PE Bridgewater Landing RETAINING WALLS Pender County, NC DESIGNER DRAWN MLK DATE 3/29/22 INSR. SCB wTE 3/29/22 ,NSR. DATE DATE CONSULTING ENGINEERS & PLANNERS HORIZONTAL SCALE 1" = 6' NO. REVISIONS DRN DATE CHK DATE SCALE SEGMENTAL RETAINING WALL REV. SHEET 7 OF 8 REV. DESIGN HEIGHT SLOPE VARIES CAP UNIT (ATTACH WITH CONSTRUCTION ADHESIVE) DIAMOND PRO 12" SEGMENTAL UNITS FINISH GRADE LEVELING PAD 2'-0" 8" MIN. LOW PERMEABLE SOIL DRAINAGE SWALE TO DIVERT SURFACE WATER GRID LENGTH (SEE ELEVATION VIEW) REINFORCED BACKFILL UNIT CORE FILL 4"0 PERF. PIPE 2% GRADE APPROX. EXCAVATION LINE TYPICAL CROSS-SECTION: SEGMENTAL RETAINING WALL 12" DIAMOND PRO UNITS (SCALE: NTS) STRUCTURAL GEOGRIDS (TYP.) (SEE ELEVATION VIEW FOR ACTUAL PLACEMENT LOCATIONS) ATTACH GEOGRID OVER PINS AND PULL TIGHT BEFORE PLACING BACKFILL BACKFILL & COMPACT IN FRONT OF WALL BEFORE BUILDING WALL BEYOND 5' HEIGHT GEOGRID ATTACHMENT DETAIL (SCALE: NTS) CERTIFICATE Ise —2446 04) 483-5225 x: (704) 483-5466 4090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©bellsouth.net oo-...0 A R O,'',. `� C)••EESS•/0•'•� ••. • 9 • • • rQ SEAL • • ft 19258 s"jei i J I NOTES: • INSTALL GEOGRID IN TENSION • COMPACT SOILS TO 95% STANDARD PROCTOR • COMPACT SOILS IN FRONT OF WALL • UNIT CORE FILL INSTALLED TO 12" BEHIND UNIT SHALL BE 3/4" MINUS STONE. • OUTLET DRAIN LINES THROUGH WALL AT 100' 0.C. WITH SCHEDULE 40 PVC 4" DIA. PIPE. • STABLE FOUNDATION SHALL BE APPROVED BY A GEOTECHNICAL ENGINEER. RETAINED BACKFILL =1 PLACE GEOGRID IN NEXT 8" LAYER OF BLOCK IN A MANNER TO REINFORCE GAPS LEFT BY PREVIOUS LAYER OF GEOGRID. WASHED STONE BACKFILL DRAINAGE STRUCTURE .11 ■11 ■11 ■11 ■11 111 I� 1I1IIIII =IIIII DRAINAGE STRUCTURE DETAIL (SCALE: NTS) I I I I I 1. J 2. 3. CONNECT GEOGRID TO DRAINAGE STRUCTURE w/ANCHOR BOLTS INSTALL WASHED STONE BACKFILL BETWEEN WALL FACE AND DRAINAGE STRUCTURE CONTINUE GEOGRID AT BACK OF DRAINAGE STRUCTURE PLACE GEOGRID IN NEXT LAYER OF BLOCK WITH THE MAIN REINFORCEMENT RUNNING 90' TO THE PREVIOUS DIRECTION BELOW. PLACE WITHIN CURVE ONLY. MIN. 3" OF SOIL BETWEEN OVERLAPPED GEOGRID (TYP.) CONCAVE CURVE GEOGRID LOCATION DETAIL (SCALE: NTS) SEGMENTAL UNIT (TYP.) CONNECTING PINS (TYP.) MD AXIS OF STRUCTURAL GEOGRID APERTURE (PERPENDICULAR TO WALL FACE) GEOGRID ORIENTATION (SCALE: NTS) 2'-0" SEGMENTAL UNIT LEVELING PAD DETAIL (SCALE: NTS) CONVEX CURVE 6" UNREINFORCED CONCRETE LEVELING PAD OR 8" WASHED STONE CAP UNIT- 12" BLOCK UNIT RAILING (BY OTHERS) 3'-0" 24" TYPICAL ROADWAY GUARD RAIL DETAIL N.T.S. CAP UNIT- 12" BLOCK UNIT TO FIT AROUND PIPE FIELD CUT BLOCKS 3'-0" 24 RAILING -� (BY OTHERS) CONCRETE FILLED POST HOLES NOTE: AUGER THROUGH TOP GEOGRID LAYER WHEN INSTALLING POSTS. TYPICAL HANDRAIL DETAIL N.T.S. WITH 3" MIN. GROUT. FILL VOIDS BETWEEN BLOCKS AND PIPE RIP —RAP TOE OF WALL BELOW PIPE GEOGRID TERMINATES WITHIN 6" OF PIPE (TYP.) GEOGRID (TYP.) REFER TO ELEVATION VIEW FOR LENGTH, TYPE AND ELEVATION NOTE: PROVIDE 3' OF #57 STONE FOR ENVELOPE AROUND PIPE. SEPARATE WASHED STONE BACKFILL FROM SOIL BACKFILL WITH A 6 OZ. GEOTEXTILE FABRIC 48' OR SMALLER PIPE PENETRATION DETAIL (SCALE: NTS) DETAILS DESIGNER: MICHAEL KISER PE Bridgewater Landing RETAINING WALLS Pender County, NC DESIGNER DRAWN MLK DATE 3/29/22 ,NsR. SCB DATE 3/29/22 INSR. DATE DATE CONSULTING ENGINEERS & PLANNERS M NO. REVISIONS DRN DATE CHK DATE SCALE SEGMENTAL RETAINING WALL REV. SHEET 8 OF 8 REV. CERTIFICATE rC-2446 T(704) 483-5225 Fax: (704) 483-5466 4090 N. NC HWY 16 P.O. Box 2189 DENVER, NC 28037 www.WWEgeo.com LKiser©bellsou th.net `4s••C •• • A teR ••. �O�•�FESS%0;4%.. •SQL y<.• . • SEAL • • 19258 . Diamond Pro detaining Walls 1.1 General Segmental Retaining Wall Systems are designed as a gravity retaining wall utilizing a high tenacity polyester geogrid to reinforce the soil zone behind the wall. The geogrid is positively connected to the modular concrete block creating a reinforced soil mass capable of resisting lateral earth pressures and surcharged loads. All references to the Engineer refer to Worldwide Engineering. 1.2 Backfill Materials The soil material associated with the retaining wall in the reinforced zone, the retained zone, or the foundation bedding shall have the following properties: A) Foundation Soils: 0=30', cohesion=0 psf, unit weight=120 lbs./cu.ft (moist weight) B) Retained Soils: 0=30% cohesion=0 psf, unit weight=120 lbs./cu.ft (moist weight) C) Reinforced Soils: 0=30', cohesion=0 psf, unit weight=120 lbs./cu.ft (moist weight) The soil characteristics above were assumed based on information supplied to the Engineer. If this information does not represent the actual soil to be used, the Engineer shall be notified immediately, the new soil parameters shall be submitted to the Engineer, and the wall will be required to be redesigned. Payment for all designs is the responsibility of the Owner and/or General Contractor. 1.3 Foundation Loads The maximum applied foundation load for this wall is 2.5 KIPS/sq.ft. 1.4 Concrete Masonry Wall Units Concrete Wall Units shall be segmental units manufactured in accordance with ASTM—C90 and ASTM C140 and shall have a minimum 28 day compressive strength of 3000 psi. 1.5 Geogrid Reinforcement The geogrid reinforcing material shall be a polyethylene or polyester meeting a minimum Long —Term Design Strength (LTDS) published by the manufacturer of: MIRAFI 3XT 1.6 Wall Batter Batter for the entire wall shall be maintained at 8 degrees (1" setback per course). 2.0 Foundation Requirements The foundation bearing capacity that was assumed for design shall be verified in the the field, and copies of the test data filed with the Engineer. The footing shall be cleared of loose soil. A minimum of 12" of washed stone shall be placed at the back of each block as indicated on the details. 2.1 Leveling Pad Material shall consist of compacted sand, gravel, crushed rock, or unreinforced concrete. The pad shall be 6" thick when pad is concrete and 8" thick otherwise. Sand or gravel material shall be compacted to 95% Standard Proctor. Aggregate material shall receive a minimum of one pass of the compaction equipment. The top of the leveling pad shall be maintained at a depth of 1.5 feet when the exposed height of the wall exceeds 7 feet. 2.2 Unit Fill The void within each unit shall be filled with a washed stone having 100% of the aggregate passing the 1.5" sieve. A minimum of 3/8" washed stone size is required (no more than 5% passing the #200 sieve). Place this material behind the block as well. All excess material shall be swept clean from the top of the block prior to installing the next course. Each course of block shall be completely filled before proceeding to the next course. 2.3 First Block Course The first course of block shall be placed on top of and in full contact with the leveling pad. The units shall maintain a distance of a minimum 6" from the front and back of the leveling pad. Proper alignment may be achieved with the aid of a string line. Place stone below the first block and the leveling pad and level the block in both directions. After placing stone in each of the appropriate holes proceed to the next course of block. Each unit shall contact the units on both sides as well as above and below. Some adjustments may be required for walls with curves and a batter. 2.4 Caps Apply a construction adhesive to the cap units to prevent their removal. 3.0 Geogrid Installation The geogrid reinforcement shall be laid horizontally on compacted backfill and installed to the face of the block. Geogrid shall be pulled taut removing all slack from the material and anchored before adding fill. Geogrid shall be installed at the elevations and lengths required as shown on the plans (refer to details for the appropriate orientation). Soil surface shall be smooth and level and have been compacted to 95% Standard Proctor before installing the grid. 3.1 Fill Placement Backfill material shall be placed on a maximum 8" compacted to 95% Standard Proctor. Only hand operated equipment shall be allowed within 3 feet of the Segmental Block units. Backfill shall be placed from the wall rearward to insure tautness of the geogrid. Construction equipment shall not be operated directly on the geogrid. 3.2 Unsuitable Materials Soils containing roots, brush, sod or other organic material shall not be allowed. Frozen soils, snow, ice, heavy clays, or wet soils shall not be allowed. Material passing the #40 sieve shall not have a liquid limit of greater than 30 and a plastic limit of greater than 15, unless written consent is obtained from the Engineer prior to placement. 3.3 Soil Properties Minimum internal angle of friction shall equal or be greater than 30° with 0 psf cohesion. Verification shall be filed with the Engineer that the soil will meet this criteria. If soils are greater than 35% fines, then the top two (2) geogrid layers shall be increased by 25% for the entire length of the wall. 4.0 Soil Testing Compaction testing shall be performed for every lift elevation requiring geogrid or every 3rd lift as a minimum Tests shall be performed for every 100 linear feet of wall face. Compaction tests as well as a verified friction angle shall be filed with the Engineer's office. 5.0 Hydrostatic Pressure Potential The Engineer shall be notified if any of the following should become evident: — water or wetness from or in a cut bank — local springs, local storm drains, sewers, water lines under or behind the wall 6.0 Acceptable Block Segmental Block units shall be used and kept free of defects that would interfere with the placing or positioning of the unit or impair its strength. Minor cracks incidental to the usual method of manufacturing or minor chipping resulting from shipment and delivery are not grounds for rejection. 7.0 Acceptable Geogrid Geogrid shall be rejected if 20% or more of a structural rib has been cut or ripped. The Contractor shall inspect all geogrid delivered to the site and reject materials that meets this criteria. If the geogrid is damaged on the construction site, it shall be replaced at the Contractors expense. 8.0 Drainage Composite- (Applies to cut wall applications only) Drainage Composite shall be installed to cover 30% of the cut behind the geogrid layers. It (6 ft. wide sections) provides 30% coverage when installed on 15 ft. centers and 2/3 the wall height. 9.0 Special Provisions A) General contractor shall coordinate upper geogrid layers installation with paving installation. B) No splices shall be made within 6 feet of each other or the modular unit. C) Maintain the direction of drainage away from the wall face at all times during construction of the wall and finish grading as shown on plans. D) Placement of geogrid shall be as per plans reference to length and elevations. E) The Engineer shall be notified by the installing contractor should the embedment depth of the block be less than 6" for walls less than 7', and less than 9" for walls greater than 7' in height. F) The reinforced soil is assumed to be a sandy type material (pure silts and clay are not acceptable). 10.0 Qualification of Design A. Stability of any temporary slopes required by the installation of segmental retaining wall shall be addressed by a qualified Georechnical Engineer. Responsibility of these temporary slopes rests with the Owner and/or Architect of this project and the slopes shall meet all OSHA standards of maximum slope steepness = 1.5H:1V. B. Handrail/guardrail requirements shall be determined by the Architect or General Contractor. C. The top of wall elevation for this design has been established by the retaining wall engineer at his discretion. The flexibility of this design allows for the top of wall to be adjusted higher of lower by 12 vertical inches and still meet acceptable factors of safety. Any adjustments to the wall height must include maintaining a maximum geogrid spacing of 24 inches and must be supplied to the retaining wall engineer in writing. D. The general contractor is responsible for integrating the retaining wall installation into the project. The general contractor is responsible for verifying that the wall configuration illustrated on these plans can be installed according to the site information provided on the civil engineer's grading plan without conflicts associated with curb and gutter, pavement sections, building foundations, utilities, or any other component to be installed in close proximity to this retaining wall system. E. All conflicts or discrepancies must be presented to the retaining wall engineer at a project meeting on site before construction begins on the retaining wall. An allowable time for revision to be made and provided by the retaining wall engineer shall be established at the same meeting before construction begins. NOTES Bridgewater Landing RETAINING WALLS Pender County, NC CONSULTING ENGINEERS & PLANNERS N DESIGNER: MICHAEL KISER PE NO. REVISIONS DRN DATE CHK DATE DESIGNER DRAWN MLK 3/29/22 !pap SCB DA,E 3/29/22 �. DATE DATE SCALE SEGMENTAL RETAINING WALL REV.