Loading...
HomeMy WebLinkAboutNCG030085_2022 DMR_20220317NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPOES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0085 Person Collecting Samples: Magdaline Tzannis !Shield Engineering Ine Facility Name: Daimler Trucks - Mount Holly Laboratory Name: Pace Analytical Facility County: Gaston Laboratory Cert. No.: 329 Discharge during this period: Yes No (if no, skip to signature and dote) Has your facility implemented mandatoryTier response actions this sample period for any benchmark exceedances? Yes f No If so, which Tier (I, If, or III)? A copy of this DMR ha en uploaded electronically via https:/Igdocs.deA.nc.gov/Forms/SW-DMR Q yes No Date Uploaded: ^� Z Analytical Monitoring Requirements for Outfalis with Industrial Activities— Benchmarks in (Red) Parameter Parameter Outfall001 Outfall002 Clutfall flutfall Outfall Code N/A Receiving Stream Class WS-IV; CA WS-IV; CA N/A Date Sample Colleted NM/DD/YYYY 2/7/2022 2/7/2022 46529 24-Hour Rainfall in inches 0.39 0.39 C0530 TSS in mg/L (100 or 50') 43 11D PH in standard units (6.0 — 9.0 FW, 00400 7,5 7.5 6.8-8.5 SW Copper, total recoverable in mg/L 01119 0,010 FW, 0.0058 SW D,p073 ❑D13 Lead, total recoverable in mg/ L O1e51 (0.075 FW, 0.22 SW) 0.0016 0.0033 Zinc, total recoverable in mg/ L (0.126 01094 FW 0.095 SW) 0.150 0.170 Chemical Oxygen Demand (COD) in 00340 mg/L(120) 37 46 00552 Non -Polar oil & Grease in mg/L (15) 1 <5.0 <5.0 0utfalIs to Outstanding Resource Waters (0RW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark T55 limit of 50 mg/i. All other water classifications have a benchmark of 100 mg/t FW (Freshwater) SW (Saltwater) I Notes (optional): Benchmark values exceeded at SDO #001 for Zn & at 5DQ #002 for TSS, Cu, Zn. I "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responslble for gathering the information, the information submitted is he best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false inf a n, including the pas�bgity of fines and imprisonment for knowing violatians." Signature af"Permittee or De Email Address Authorized Individual E a� Date �O� _5Z. l] b Phone Number