Loading...
HomeMy WebLinkAboutNCG551149_Inspection_20220428DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Lindsey Dunn 2522 Ferrell Road Durham, NC 27704 Dear Ms. Dunn: NORTH CAROLINA Environmental Quality April 28, 2022 Subject: Compliance Evaluation Inspection Single Family Wastewater Treatment System General NPDES Permit NCG550000 Certificate of Coverage NCG551149 Facility: 2522 Ferrell Road Durham County On April 22, 2022, Alys Hannum from the Raleigh Regional Office visited your single-family residence wastewater treatment system to evaluate compliance with the subject General National Pollution Discharge Elimination System (NPDES) Permit. Your assistance during the inspection was greatly appreciated. Our records indicate the treatment system consists of a septic tank, sub -surface sand filter, tablet chlorinator with chlorine contact chamber, and discharge pipe. General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG551149 authorize the discharge of domestic wastewater from your treatment system to receiving waters designated as an unnamed tributary to Panther Creek in the Neuse River Basin, in accordance with the effluent limits and monitoring requirements established within the General Permit. The following conditions were noted at your facility: • Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. During the inspection, you provided documentation showing Central Carolina Services pumped out the septic tank on June 11, 2019. • Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful NORTH CAROLINA Department of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA Lindsey Dunn, 2522 Ferrell Road Certificate of Coverage NCG551149 April 28, 2022 Page 2 of 3 bacteria from discharging to the environment. The product label for these tablets must indicate the tablets are approved for wastewater use and not for swimming pools. Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. The inspector did not observe any chlorine tablets in the chlorinator. Please ensure the correct type of tablets are used and maintained in the chlorinator as required by the General NPDES Permit. • Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform and Total Residual Chlorine. During the inspection, you informed the inspector that the effluent has not been monitored within the last 12 months because there has been no flow through the system. If the system does begin to flow, please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCGSS0000. • Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The discharge pipe was visible and accessible the day of the inspection. Please continue to ensure the outlet is always visible/maintained and cleared of vegetation, soil and leaves. Division records indicate the required annual fee ($60 per year) due September 2, 2021, for the period ending August 31, 2022, has been paid. There are no overdue fees for the subject COC. Please continue to periodically inspect the wastewater treatment system to ensure the treatment components are always maintained and in good operating order. You are also reminded to maintain all monitoring data and associated maintenance records onsite for a minimum of three years for inspection. NORTH CAROLINAD_E Department of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA Lindsey Dunn, 2522 Ferrell Road Certificate of Coverage NCG551149 April 28, 2022 Page 3 of 3 If you have questions or comments about this, please contact Alys Hannum at alys.hannum@ncdenr.gov, or by phone at 919-791-4255. Sincerely, DocuSigned by: FhttALSSA, f. Al1.a tAlta B2916E6AB32144F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): EPA Water Compliance Inspection Report cc: RRO/SWP Files Laserfiche GD_E NORTH CofEn NA Deparbnent iR of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 21IIIIII 671 Code IN I 2 IL I NPDES yr/mo/day Inspection 3 I NCG551149 111 121 22/04/22 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved I 70I4 I 711 1 72 I N I 73I 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) 2522 Ferrell Road 2522 Ferrell Rd Durham NC 27704 Entry Time/Date 10:OOAM 22/04/22 Permit Effective Date 21/12/28 Exit Time/Date 10:30AM 22/04/22 Permit Expiration Date 25/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Lindsey C Dunn,2522 Ferrell Rd Durham NC 27704//919-909-6889/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenar Self -Monitoring Progran Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Alys K Hannum of Inspector(s) Agency/Office/Phone and Fax Numbers ,-Docusignedby: DWR/RRO WQ/919 791-4255/ a.uwo+-sx. "-4C22170C5AA04F3... Date 4/25/2022 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date IDocuSigned by: ou,SSa f. ll.aln t , 4/26/2022 B2916E6AB32144F... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA NPDES yr/mo/day 31 NCG551149 111 121 22/04/22 I17 Inspection Type 18LI 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# 2 DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA Permit: NCG551149 Inspection Date: 04/22/2022 Owner -Facility: 2522 Ferrell Road Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Comment: Sand Filters (Low rate) (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re -circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) Comment: Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Tablet chlorinator did not have any tablets at the time of inspection. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Yes No NA NE ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ 1 • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: A98D518F-1171-4C8B-BC82-0E5F86A8EAAA Permit: NCG551149 Inspection Date: 04/22/2022 Owner -Facility: 2522 Ferrell Road Inspection Type: Compliance Evaluation Effluent Sampling Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: System has not been sampled recently due to a lack of flow. Yes No NA NE ❑ • ❑ ❑ ❑ • ❑ ❑ Page# 4