HomeMy WebLinkAboutSW3220201_Plansheet - Other_20220425 (5)` \ UTILITY NOTES 1. UTILITY CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODE REQUIREMENTS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL EXISTING 1 / I \ \� \ 1 1 / h UNDERGROUND UTILITIES (STORM DRAINAGE, ELECTRIC, GAS, TELEPHONE, ETC.) PRIOR TO SITE �,2 1 G \� / 1 I' \ 1 � \ � � / 1 CONSTRUCTION. INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY AND SHALL BE FIELD ` VERIFIED BY THE CONTRACTOR. tlk �\ 3. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY IF ANY DISCREPANCIES BETWEEN THE CONSTRUCTION PLANS AND ACTUAL FIELD CONDITIONS ARE FOUND. G 4. MINIMUM COVER FOR ALL SANITARY SEWER MAINS SHALL BE 3'-0". DUCTILE IRON PIPE SHALL BE SUBSTITUTED WHEN MINIMUM COVER CAN NOT BE MAINTAINED. 5. THE STANDARD DEPTH OF COVER FOR WATER MAINS SHALL BE 3'-0" MIN. EXCEPT AT VALVE OR HYDRANT LOCATIONS OR OTHER SPECIAL CONDITIONS. 6. THE CONNECTION TO EXISTING WATER MAINS SHALL BE PERFORMED ONLY AFTER ALL PRESSURE TESTING AND CHLORINATION ARE SUCCESSFULLY COMPLETED AND THE LOCAL REVIEW AUTHORITY HAS APPROVED THE CONNECTION. THE CONTRACTOR SHALL AVOID DISRUPTION OF EXISTING SERVICE. VICI MAP I \ \ \ 7. REFER TO PLUMBING DRAWING SERIES FOR THE LOCATION OF WATER AND SANITARY SEWER SERVICE SCALE:_1�4,000 I I \ \ \ <" 1 / CONNECTIONS AT THE BUILDING. 8. UNLESS OTHERWISE NOTED, THE PHYSICAL CONNECTION BETWEEN THE SITE UTILITY LINES AND THE PIPE INSTALLED BY THE PLUMBING CONTRACTOR SHALL BE MADE BY THE SITE UTILITY CONTRACTOR. INVERTS AND SHALL NOT BE CONSTRUED BY THE CONTRACTOR TO REPRESENT THE ACTUAL QUANTITY OF PIPE REQUIRED. 1_ 10. IF WATER LINE CROSSES OVER SANITARY SEWER WITH LESS THAN 18 INCHES VERTICAL CLEARANCE BOTH PIPES SHALL BE DUCTILE IRON 10' EACH SIDE. IF WATER CROSSES UNDER THE SEWER \ \ \ � � \ \ \\ � I ( \� REGARDLESS OF CLEARANCE, BOTH PIPES SHALL BE DUCTILE IRON 10' EACH SIDE. IF WATER LINE RUNS PARALLEL TO SEWER LINE WITH LESS THAN 18" VERTICAL CLEARANCE AND LESS THAN 10' SIDE �/ \_i �` ✓`�—� \/ ', , -_ \ \ ' \ \ \ \ \ \ CLEARANCE BOTH PIPES SHALL BE DUCTILE IRON. \ \ I 11. IF REQUIRED BY NUMBER 10 ABOVE, REPLACE EXISTING SEWER WITH DUCTILE IRON PIPE, CLASS 350 WORKING PRESSURE WITH GASKETED JOINTS, 10' EACH SIDE OF WATER MAIN. 12. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. G \ I \ J 4 CONNECTION POINTS, OR OTHER WATER -USING APPURTENANCES CONNECTED TO THE SUPPLY LINE �-- \ \ \ \ \ 1 I BETWEEN ANY WATER METER AND ITS WSACC REQUIRED BACKFLOW PREVENTER. 13. THE CONTRACTOR SHALL NOTIFY THE LOCAL FIRE DEPARTMENT IF REQUIRED WORK COINCIDES WITH \ THE SHUT OFF OFF ANY EXISTING, IN-SERVICE FIRE HYDRANTS OR OTHER FIRE PROTECTION DEVICES. _N \ I `% ` ................. � f� -- ---- \ \\ \ \ \ \ \ \ 1 �- \ �_ ( S _ 6�7.�--\-�- � FES 8.64 \ _640 FES 6s %\ \ \ \ \ 650• / \1 \ — \ IN. PROPOSED BARN LOCATION 7 I \ \ \ D �— �x \\\ \\� \ \ I / ''L •-E _ — — \ — .® o . / / // EXISTING FIRE < �\\ HYDRANT \cz le _ l l iI UGE J UGE / \ / �E I GE G ) 1 \ \ \ � � ,, UGE �UG � � / \ \ � p PROPOSED 8" \lam I �n //ice `G \ . \ /� Ut� U E I I \ � �\— WATER LINE \ / E GE UGE UG UGE UG UGE GE 64 / \ UT uy T�u;SS TIE TO EXISTING 6" BFP .00 PROPOSED 8 \\ \ WATER LINE / \ i \ \ \ \ \\ \ / r / / ' / y� / G�� ! ��\ / / i / / EXISTING 8" SANITARY SEWER 1 I U I GE UGE \ > / \ I -� �� \ SHEET C401 SHEET C402 Son / / ` -- 7 ) 1 / ♦ f I 11 / �-- - / ( �/ r oll J to — / / / / \ �` `\ \ \ / / 1 1 / / / f • c/Y \ `' ` \ Know what's below. \ \ / Call before you dig. \ _ i NORTH 60 0 30 60 1: SCALE: 1 "=60' z J w 704.333.0093 C DESIGN INC. www.cdesigninc.com Cabarrus County Frank Liske Park 4001 Stough Rd Concord, NC 28027 Kyle Bilafer 704.920.3201 Alfred Benesch & Company 2359 Perimeter Pointe Parkway, Suite 350 Charlotte, NC 28208 www.benesch.com 704.521.9880 Project # 17000392 I copyright 2021, C DESIGN INC. I�DPLAN NORTH z PROJECT NUMBER O DATE O 0604-0522 10.28.2021 z Overall Utility Plan LI J w 07 C400