Loading...
HomeMy WebLinkAboutSW3220201_Plansheet - Misc. Detail_20220425 (8)2'-6" (MIN.) FINISHED GRADE O 00 COMPACTED EARTH BACKFILL —1 1—I —I Y- I i— ADJUSTABLE CAST IME dI-1 li IRON VALVE BOX GRAVEL OR �j 6" GATE WASHED STONE VALVE CONC. SUPPORT PAD AND THRUST BLOCK a UNDISTURBED EARTH II —I zQ 2 4" GALVANIZED RODS WITH GALVANIZED NUTS OR TYLER LONG SWIVEL ADAPTER TEE CONNECTION 00 OR EQUAL TO WATER MAIN CONC. THRUST BLOCK UNDISTURBED EARTH NOTES: 1. ON ROADS WITH CURB AND GUTTER, INSTALL HYDRANT 2' FROM BACK OF CURB; ON ROADS WITHOUT CURB AND GUTTER, INSTALL HYDRANT 6' FROM EDGE OF PAVEMENT. 2. 4" OUTLET TO BE TURNED FACING ROADWAY. 3. CONCRETE BLOCKING TO EXTEND TO UNDISTURBED EARTH, SEE DETAIL FOR MINIMUM DIMENSIONS. 4. FIRE HYDRANT TO BE MEET THE REQUIREMENTS OF THE TOWN OF WINGATE. 5. SEE UTILITY PLAN FOR ACTUAL CONFIGURATION OF FIRE HYDRANT, PIPE, VALVES, AND CURB & GUTTER. I Fire H Brant Assembl N.T.S. SHUT-OFF VALVE #1 SEE NOTE #2 TEST COCK #1 RESTRAINED JOINT SEE NOTE #3 HINGED ACCESS OR REMOVABLE INSULATED ENCLOSURE MEETING ASSE 1060 SPECIFICATIONS. ENCLOSURE TO INCLUDE DRAIN PORT(S) PER CLT WATER REQUIREMENT. SUPPORTS SEE NOTE #4 SLOPE GROUND COVERAWAYFROM I=III—I a— SLEEVE REQUIRED (TYP. ) RESTRAINED JOINT SEE NOTE #3 2 1 /2" - 10" Reduced Pressure Principle Assembl (Above Ground), N.T.S. UNDISTRUBED EARTH TEE CONNECTION =1I TO WATER MAIN CONC. SUPPORT _ a PAD AND THRUST =III— • CONC. THRUST _ ° _' 1= I— BLOCK BLOCK 11 III III III L� -1-1 11-1 UNDISTURBED 2— J" GALVANIZED RODS W/ EARTH GALVANIZED NUTS OR TYLER LONG SWIVEL ADAPTER OR EQUAL (TYP.) 6" THICK LAYER OF #57 WASHED STONE Fire Department Connection N.T.9. o i� LOCKING KNOX BOX CAPS TO BE INSTALLED. UL LISTED FIRE DEPARTMENT CONNECTION SIZE AND THREADS SHALL MEET CITY FIRE DEPARTMENT REQUIREMENTS FDC SIGN CHAINED TO FDC (SUBMIT SHOP DRAWING OF FINAL DESIGN) FINISHED GRADE 90° BEND 6"0 GALVANIZED PIPE 6" 0 CHECK VALVE W/ BALL DRIP 6" 0 DIP OR GAL. PIPE REDUCED PRESSURE PRINCIPLE ASSEMBLY � J CHECK VALVE #1 CHECK VALVE #2 FLOW 12" MIN. RELIEF VALVE 30" MAX. OUTLET o a a 1 a a L LOWEST POINT OR RELIEF VALVE OUTLET SUPPORT, PAD AND CONCRETE FOOTINGS AS REQUIRED BY SYSTEM DESIGNER — SHUT-OFF VALVE #2 SEE NOTE #2 LCOVER MUST NOT OBSTRUCT VALVE V" MIN. BEING FULLY OPENED MIN. 4" THICK CONCRETE PAD REQUIRED SUPPORTS SEE NOTE #4 DUCTILE IRON PIPE OR TYPE K OR L COPPER TUBING FOR MIN. OF 5' ON EACH END OF ASSEMBLY. SEE NOTE #3 SLEEVE REQUIRED (TYP. ) �5 IT mf- - - - - - m � a PLAN -BENDS 24" MIN. — 12" & LARGER PIPE 18" MIN. — 10" & SMALLER SECTION X-X 1/4 BENDS 1/8 BENDS1/16 BENDS TEES PLUGS SIZE A B A B A B A B C D 2 1/2"-4" 16" 10" 9" 10" 6" 8" 10" 12" 10" 21" 8" 1 22" 13" 12" 13" 8" 10" 13" 16" 12" 29" 10" 26" 17" 14" 17" 10" 13" 16' 20" 14" 36" 12" 29" 21" 16" 21" 11 "1 16" 18" 24" 16" 41" 14" 35" 24" 19" 24" 12" 20" 22"1 27" 18" 48" 16" 38" 27" 21" 27" 1 12" 24" 24" 1 30" 20" 54" 6" THICK C SLOPE TO DR/ 18" MIN. c/ o o � U U N N PLAN & ELEV. - PLUGS Q NOTE: BASED ON 100 PSI STATIC PRESSURE PLUS AWWA WATER HAMMER ALL BEARING SURFACES TO BE CARRIED TO UNDISTURBED GROUND Concrete Thrust�Blo�ck T.S � N.. NOTE: 1. POST INDICATOR VALVE SHALL BE MUELLER CO. MODEL #A-20804 OR APPROVED EQUAL. 2. PROVIDE SUPERVISORY SWITCH, ENUNCIATED TO FIRE ALARM PANEL. b Post Indicator Valve N.T.S. I-1/'1T A TIA I^ WRENCH ',OMMON SITION INDICATOR DRIVEWAY/STREET ;ONC. I) ADE /E 4 �N.T.e ValveS. "'A"'r `_RVICE CAST FINISH GRADE OR PAVING ADJUSTABLE CAST IRON VALVE BOX SLEEVE WITH COVER CAST IRON VALVE BOX BASE SEE PLANS AND SPECIFICATIONS FOR SIZE AND TYPE OF VALVE 704.333.0093 C DESIGN INC. www.cdesigninc.com U LU O Cabarrus County Frank Liske Park 4001 Stough Rd Concord, NC 28027 Kyle Bilafer 704.920.3201 cbenesch 4� y Alfred Benesch & Company 2359 Perimeter Pointe Parkway, Suite 350 Charlotte, INC 28208 www.benesch.com 704.521.9880 Project # 17000392 J LU U) 1 copyright 2021, C DESIGN INC. U) Z O co LU N ry PLAN NORTH z PROJECT NUMBER 0604-0522 DATE 10.28.2021 Q ry O LL Site z Construction w Details LU _ co C503