Loading...
HomeMy WebLinkAboutWQ0043382_Application (FTSE)_20220328DWR Division of Water Resources -S C Dept of Envirceaental Quality tti S 2072 State of North Carolina Department of Environmental Quality Division of Water Resources FASTIWICK SEWER SYSTEM EXTENSION APPLICATION Leigh u cbt°"ak °I "Cc FTA 06-21 & SUPPORTING DOCUMENTATION App ication Number: V A - O 33 Ip be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: I. Applicants name: Pulse Ilome Company, LL.0 (company, municipality, HOA, utility, etc.) 2 Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑Privately-Owned Public Utility ❑ Federal ❑ State/County Municipal ® Other 3. Signature authority's name: _Chris Raughley per I5A NCAC 02'1'-0106(h) Title: __Vice President of Land Devclopmtent 4. Applicant's mailing address: 1225 Crescent Green Drive. Suite 250 City: Cary State: NC Zip: 27518 5. Applicant's contact information: Phone number; (919) 448-6308 Email Address: Chris.RaughleyO PulteGroup,com IL PROJECT INFORMATION: 1. Project name: Braxton - j I. A z t. 2. Application/Project status: X Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Durham 4. Approximate Coordinates (Decimal Degrees): Latitude; 35 948440` Longitude:-78.870940' 5. Parcel ID (if applicable): 163366. 163355, 209141, 163356, 163357 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Ariel Gamboa License Number: 41363 Firm: Horvath Associates, PA Mailing address: 16 Consultant Place. Suite 201 City: Durham State: NC Zip: 27707- Phone number: (919) 490-4990 Email Address: Ariel.Gamboa(d HorvathAssociates.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Triangle Wastewater Treatment Plant Permit Nurnber: NC0026051 Owner Name: Durham County V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ 2. Downstream (Receiving) Sewer Information: 12 inch 0 Gravity O Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00005 Owner Name(s): City of Durham FORM: FTA 06-21 Page I of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A 2, If the Applicant is a Developer of lots to be sold, has a Developer's Operrtiopp! rccpj F _QRM: DF;V) been attached? ® Yes ❑ No ❑ N/A 3. If the Applicant is a Home.Property Owners' Association, has an HOAROA Operational Agreement (FORM: I IOAI and supplementary documentation as required by 1 5A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No El WA 4. Origin of wastewater: (check ail that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ School / preschool . day care ❑ Medical 1 dental / veterinary facilities ❑ Food and drink facilities ❑ Church O Businesses / offices ! factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels O Swimming Pool/Clubhouse ❑ Swimming Pool/Filter Backwash O Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Has a flow reduction been approved under I5A NCAC 02T .01 l4M? ❑ Yes ® No D Ifyes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(0) Daily Design Flow a,b No. of' Units Flow Townhome Development 360 gal/day/Unit 33 11880 GPD gal/ GPD gal/ GPD gall GPD gall GPD gall GPD Total 11880 GPD a Sec I5A NCAC 02T .0114(b). (d). (c)( I) and (c)(2I for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02E01141 shall be determined using available flow data, water using Mures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: _ GPD (per I5A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. 0 Flow has already been allocated in Permit Number: _ Issuance Date: 0 Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Cra‘ity Sewers: 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 420 PVC D Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Punta Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN TI IIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: ° Longitude: - . 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) D This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the me hod of solids reduction per MDCPSFM Section 2.0I C. I.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02'T .0305(11)(I ): ❑ Standby power source or ❑ Standby pump D Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): D Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent 10 facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day I5A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: D include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. D If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B.0200 & 15A NCAC 02T .0305(f)): I Does the project comply with all separations/alternatives found in 15A NCAC 02T .030511) & (g)? ® Yes ❑ No 15A NCAC 02T,0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* —1 Separation Required 1 Storm sewers and other utilities not listed below (vertical) 2Water mains (vertical - water over sewer preferred, including in benched trenches) r 'Water mains (horizontal) Reclaimed water lines (vertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 18 inches 18 inches 10 feet 18 inches 2 feet 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 fect Any building foundation (horizontal) Any basement (horizontal) 5 feet 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains Any swimming pools 5 feet 10 feet Final earth grade (vertical) 36 inches If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 021-.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved_ Please check "yes" above if these altematives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Watcr Classifications wchpaite 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A D If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? • Please provide supplementary information identifying the areas of non-conformance. D See the Division's drali separation requirements for situations where separation cannot be met. • No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear If yes, does the project comply with setbacks found in the river basin rules per t 5A NCAC 92B ,0200? ➢ This includes Trout Buffered Streams per I5A NCAC 2B.tJ2U2 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits or 401 Water Quality Certifications? D Please provide the permit number/permitting status in the cover letter if coverage/authorization is req Yes ❑ No 0 N/A ❑ No ® Yes ❑ No ® Yes 0 No aired. 6. Does project comply with I5A NCAC 021.(I105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.010S(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per I5A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. Y If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's Individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 02T, the Mininunn Design Criteria for the Permitting of Pump Stations and Force Maiuiilate.t tcrsioki), and the Gravity Sewer Minimum Design Criteria (latcstvcrsiollj as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will he issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For protects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the protect, the full technical review is required. 2, Professional Engineer's Certification_ 1, _Ariel Gamboa , attest that this application for _ Braxton_ (Professional Engineer's name from Application Item ILIA.) (Project Name from Application Item II 11 has been reviewed by me and fs accurate, complete and consistent with the Information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the hest drily knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum D .sign Crijeria for Gaiyity Sewcr.Qhtiest version). and the ntunum I •.i •u Cri •aly the .t-'1" • P RPfltitt orruntn Station ,tnd 1=orcc Matins limiest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): N PACAR G , €..���0 .•F C S s ipN`42• ,: P.- 1., - .FHGINGOQ'miesto I, Chris Raughley , attest that this application for Braxton (Signature Authority Name from Application Item 1.3,) (Project Name limn Application Item II.I ) attest that this application has been reviewed by nie and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes J 43-215.6A and 1 43-215,613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a Fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature; Date: 2.. - . — Z L FORM! FTA 06-21 Page 5 of 5 74 HORVATH ASSOCIATES Civil Engineers Planners Landscape Architects DATE: TO: FROM: SUBJECT: Ariel Gamboa, PE Fast Track Sewer Application Braxton - Private Cover Letter February 10, 2022 North Carolina Department of Environmental Quality Raleigh Regional Office -Water Quality Section 1628 Mail Service Center NC Dept Quality Raleigh, NC 27699-1628 p of Environmental ualit MAR 2 8 2022 R.aleigh Regional Office This is a residential Apartment Complex on a 43.65 acre site with 192 townhome units located at 1432 Ellis Road in Durham North Carolina. This application is for the installation of 420 feet of new private sewer line generating 0 gpd. Total flow of 69,120 gpd is reflected on the Public Sewer Application. The following items have been included with the application package: • 1 Cover Letter • 1 Original FTA • 1 Check for $480.00 • 1 Information on LLC from NC Secretary of State • 1 Flow Tracking/Acceptance Form • 1 Copy of USGS Map • 1 Copy of Street Level Map North Carolina 16 Consultant Place, Suite 201 Durham, NC 27707 p 919-490.4990 f 919-490-8953 Tennessee Post Office Box 970 Harrison, TN 37341 p 423-266-4990 STATE OF NORTH CAROLINA COUNTY OF Durham Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this day of , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Puite Home Company, LLC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: I. The DEVELOPER is the owner of the certain lands Tying in Durham County, upon which it is erecting and will erect dwelling units and other improvements, said development to beknown as Braxton (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, Braxton Homes Owners Association, Inc. (hereinafter Association), a non-profit corporation organized and existing under and by the virtue ofthe laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System ofthe Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPERS successor. FORM: DEV 03-I9 Page 1 of2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit mayrequire as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of apermit. 9. The agreements set forth in numbered paragraphs I, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL Pulte Home Company, LLC - Chris Raughley 1xAGEMSS NT CO MISSION Name of DEVELOPER N t, By: l.st.1 Q Linda Culpe r (Signature) Director, Division of Water Resources (Date) pr, VP Land Development Print Name and Title 3A3 22, 2. • z1/4k • 22, (Date) FORM: DEV 03-19 Page 2 of 2