HomeMy WebLinkAboutSW1210902_Supplement-EZ Form_20220425SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name Broadpolnte Industrial Facility
2
Project Area ac
25,064
3
Coastal Welland Area ao
0
4
Surface Water Area ac
0.006
5
Is this project High or Low Density?
Both HI h and Low Densif
6
IDoes this project use an off -site SCM?
No
COMPLIANCE WITH 02H .1003[4]
7 Width of ve etated setbacks provided feet
30
e
Will the vegetated setback remain vegetated?
Yes
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 e d ?
Yes
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
0
12
Biorelention Cell
0
13
Wet Pond
0
14
Stormwater Welland
0
15
Permeable Pavement
0
16
Sand Filter
1
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
0
20
Disconnected Impervious Surface O15
0
21
Treatment Swale
0
22
Dry Pond
0
23
StormFiller
0
24
Silva Cell
0
25
Ba fitter
0
26
Hlorra
0
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
Daniel H alt
28
Organization:
Wade Trim Ina
29
Street address:
53 North Market Street
30
City, Stale, Zip:
Asheville, NC 28801
31
Phone numbers :
8282551197
32
Email:
rhyall@wadetrim.com
Certification Statement:
I certify, under penally of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; That
the Information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engfneering plans,
specificalions, operation and maintenance agreements and other supporting information are consistent with the information provided here.
ti,,�nrtrrrunr
r
GAR0<j''%,
��`•`�O� ti PN0 S C.,
rW �05 �,
_ No �T,4. 0 _
e A � r • (a �
+r
of Designer
Z®le?e-
Dat
DRAINAGE AREAS
1
Is this a hi h densityproject?
Yes
2
If so, number of drainage areaslSCMs
1
3
Does this project have low densityareas?
Yes
4
If so, number of low densitydrainage areas
1
r5
Is alllpart of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE
AREA INFORMATION
Entire Site
1
LD 1
4
Type of SCM
NIA
Sand Filter
Dispersion Flow, &
Vegetated
Conve ence
5
Total drainage area (sq ft
7092049___
273174
818875
6
Onsite drainage area (sq ft
1092049
0 _
223399 sf
NIA
273174
818875
7
Offsite drainage area (sq fl
0
0
8
Total BUA in project s ft
21680i sf
6599 sf
9permitting)
New BUA on subdivided lots (subject to
s fl
NIA
NIA
10permitting)
New BUA not on subdivided lots (subject to
s
223399 sf
216801 sf
6599 sf
11
Offsite BUA (scl ft
sf
sf
sf
12
Breakdown of new BUA not on subdivided lots:
Parking (sq fl
97872 sf
91274 sf
6599 sf
- Sidewalk (sq ft
4965 sf
4965 sf
sf
Roof (sq fl
120562 sf
120562 sf
sf
- Roadway (s ft
NIA
NIA
NIA
Future (sq fE
NIA
NIA
NIA
- Other, please specify in the comment box
below (sq fl
WA
NIA
NIA
13
New infiltrating permeable pavement on
subdivided lots (sq ft
WA
NIA
NIA
14
New infiltrating permeable pavement not on
subdivided lots (sq ft
WA
NIA
NIA
15permitting)
Existing BUA that will remain (not subject to
s ft
WA
NIA
NIA
16
Existing BUA that is already permitted (sq ft
WA
NIA
i 7
Existing BUA that will be removed (sq fl
NIA
NIA
_NIA
NIA_
18
Percent BUA
21%
79%
_ _ 1%
19
Design storm Inches
1.0 in
1.0 in
NIA
20
Design volume of SCM cu fl
NIA
13417 cf
NIA
21 lCalculation
method for design volume
NIA
Simple Method
NIA
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 ldfainage area(s):
LD1 designed to have sufficient dispersion at pipe outlet; sized for 10 year
storm event
LOW DENSITY
DESIGN REQUIREMENTS FOR LOW DENSIrL PROJECTS FROM 02H .1003
1 Is project below density thresholds set forth in the applicable stormwater rule?
Yes
2
IDoes project maximize dispersed flow and minimize channehzation of flow?
Yes
3
Has the use of piping been minimized per .1003(2)(c)?
Yes
4
Sfde slopes of the vegetated conveyances (H:V)
2:1
5
Maximum veracity in the vegetated conveyances during the 10-year storm?
6
6
Are curb outlet swales proposed?
No
7
Maximum longitudinal slope of curb outlet swale(s) (%)
0
Bottom width of curb outlet swale(s) (feet)
9
Maximum side slope of curb outlet swale(s) (H:V)
10
Minimum length of cufb outlet swale(s) (feet)
11
Are treatment swales used instead of curb outlet swales?
No
12
Is stormwater released at the edge of the setback as dispersed flow?
Yes
13
Have stormwater outlets been designed to prevent downslope erosion?
Yes
14 JAre
variations to rule .1003 proposed?
No
ADDITIONAL
INFORMATION
15
please use this space to provide any additional information about this low density project:
Low -Density Portion of this project: Swale 1 = Ditch-2, reference plan sheet C2.1 High -
Density Portion of this project: Swale 2 = Ditch-1A, Swale 3 = Ditch-1 B, Swale 4 = Ditch-1C, reference plan sheet C2.1 SCS
method was used for the following calculations
�®
r •r
�
:r rr
�r
�
rr
�
r
SAND FILTER
1 I Drainage area number DA-SF
�2 Minimum re wired treatment volume cu ft 13059 st
FRIG ERAL MDE FROM 002H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contamfnated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
2:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion
10- ear storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Drawdown Orifice
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
It the SCM is on a single family lot, does (will?) the plat comply with
General MDC 10 ?
NIA
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
161
Does the SCM follow the device specific MOC?
Yes
17 1
Was the SCM designed by an NC licensedprofessional?
Yes
SAND FILTER
MDC FP.QM QZH.1056
18
SHWT elevation (fmso
2046.5 ft
19
Type of sand filter (open or closed
O en
20
If dosed, will the filter will be pre -cast or pour -in -place?
21
If dosed, top of grate elevation (fmsl)
N/A
22
Is this sand filler designed to attenuate peak flows?
No
ISedlment Chamber
23
Volume that can be retained in the sediment chamber (cubic feet)
5379 cf
24
Will there be a permanent pool in the sediment chamber?
No
25
Bottom of the sediment chamber fmsl
2058.50
26
Area of the sediment chamber (square feet
1823 sf
27
Physical depth of the sediment chamber (inches)
12 in
28
Ponding depth in the sediment chamber, above any permanent pool
(inches
36 in
29
Flevation of top of weir between chambers fmsi
2059.5
ISand Chamber
30
Volume that can be retained in the sand chamber cubic feet)
8057 cf
31
Bottomof the sand chamber (fmsQ
2059.50
32
Area of the sand chamber(square feet)_1623
sf
33
Physical depth of the sand chamber inches
18 in
34
Ponding depth in the sand chamber, above the sand surface
(inches)
36 In
35
Elevation of the bypass device (fmsl
2062.5
36
Type of bypass device
Inlet
37
Mechanism for distributing now over the sand surface
Level Weir
38
Sand_specifiGatlon for sand chamber
ASTM C-33
39
Depth above underdrain pipe (inches)
18 in
40
Will the media be maintained to drain at least two inches per hour at
the sand surface?
Yes
41
Is at least one dean-oul pipe provided at the low point of each
underdrain line?
Yes
42 Will clean -out piE2s becapped?
ADDITIONAL INFORMATION
43 Please use this space to provide any additiional Information about the
sand filler(s):
Yes