Loading...
HomeMy WebLinkAbout670046_Compliance Evaluation Inspection_20220407Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 670046 Facility Status: Active Permit: AWS670046 ❑ Denied Access Inspection Type: Compliance Inspection Inactive Or Closed Date: Reason for Visit: Routine County: Onslow Region: Date of Visit: 04/07/2022 Entry Time: 08:45 am Exit Time: 10:00 am Incident #: Farm Name: Jenkins Farm Inc Owner Email: Wilmington Owner: Jeffrey Jenkins Phone: 910-340-0431 Mailing Address: 207 Robin Trl Richlands NC 285745293 Physical Address: 207 Robin Trl Richlands NC 28574 Facility Status: ❑ Compliant • Not Compliant Location of Farm: Integrator: Latitude: Murphy -Brown LLC 34° 45' 03" Longitude: 77° 39' 41" West of Angola. South side of SR 1201 approx. 0.25 mile West of SR 1202. Farm is at of end Robin Trail across from country store. Question Areas: ▪ Dischrge & Stream Impacts ▪ Records and Documents ▪ Waste Col, Stor, & Treat ▪ Other Issues Waste Application Certified Operator: Secondary OIC(s): Operator Certification Number: On -Site Representative(s): Name Title Phone 24 hour contact name Jeff Jenkins Primary Inspector: Inspector Signature: Secondary Inspector(s): Brian S West Phone: 910-796-7341 Date: Inspection Summary: Modified WUP 9/21-removed fields 7-9, remaining fields aerway. Recent rain this week resulted in FB overage, both lagoons POA pending (received 4/7). Ensure correct acreages on IRR-2 forms (no overages noted). Soil samples due 2022. Keep crop yield, stocking average up to date. No sludge survey 2021, levels very low 2020-requesting waiver. NOD- FB and SS if waiver not granted NOD-2022-PC-0044 received 4/20 incident no. 202200567 Page 1 of 5 Permit: AWS670046 Owner: Jeffrey Jenkins Inspection Date: 04/07/22 Inspection Type: Compliance Inspection Facility Number: 670046 Reason for Visit: Routine Regulated Operations Design Capacity Current promotions Swine Swine - Farrow to Wean Waste Structures Type 1,800 1,823 Identifier Effective Date Total Design Capacity: Total SSLW: Built Date 1,800 779,400 Closed Designated Observed Date Freeboard Freeboard Lagoon LAGOON #1 03/29/2005 D5/01/1993 20.00 19.00 Lagoon LAGOON #2 03/29/2005 35/05/1993 20.00 14.00 Page 2 of 5 Permit: AWS670046 Inspection Date: 04/07/22 Owner: Jeffrey Jenkins Facility Number: 670046 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: Structure Application Field Other a. Was conveyance man-made? b. Did discharge reach Waters of the State? (if yes, notify DWQ) c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the State other than from a discharge? Waste Collection, Storage & Treatment 4. Is storage capacity less than adequate? If yes, is waste level into structural freeboard? 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management or closure plan? 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect application? If yes, check the appropriate box below. Excessive Ponding? Hydraulic Overload? Frozen Ground? Heavy metals (Cu, Zn, etc)? PAN? Is PAN > 10%/10 lbs.? Total Phosphorus? Failure to incorporate manure/sludge into bare soil? Outside of acceptable crop window? Evidence of wind drift? Application outside of application area? Crop Type 1 Yes No NA NE ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ Yes No NA NE ❑ • ❑ ❑ ❑ • ❑ ❑ Page 3 of 5 Permit: AWS670046 Inspection Date: 04/07/22 Owner: Jeffrey Jenkins Facility Number: 670046 Inspection Type: Compliance Inspection Reason for Visit: Routine Waste Application Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? 17. Does the facility lack adequate acreage for land application? 18. Is there a lack of properly operating waste application equipment? Records and Documents 19. Did the facility fail to have Certificate of Coverage and Permit readily available? 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check the appropriate box below. WUP? Checklists? Design? Maps? Lease Agreements? Other? If Other, please specify 21. Does record keeping need improvement? If yes, check the appropriate box below. Waste Application? Weekly Freeboard? Waste Analysis? Soil analysis? Waste Transfers? Weather code? Rainfall? Stocking? Crop yields? Yes No NA NE ❑ • ❑ ❑ ❑ • ❑ ❑ Yes No NA NE ❑ • ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • • Page 4 of 5 Permit: AWS670046 Inspection Date: 04/07/22 Owner: Jeffrey Jenkins Facility Number: 670046 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents 120 Minute inspections? Monthly and 1" Rainfall Inspections Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below: Failure to complete annual sludge survey Failure to develop a POA for sludge levels Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. Application Field Lagoon / Storage Pond Other If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAW M P? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? 34. Does the facility require a follow-up visit by same agency? Yes No NA NE • ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ • no survey 2021, applying for waiver ❑ • ❑ ❑ ❑ ❑ • ❑ Yes No NA NE ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • Page 5 of 5