Loading...
HomeMy WebLinkAboutNC0021946_Wasteload Allocation_19920514NPDES DOCIMENT :MCANNINO COVER SHEET NC0021946 Rosman WWTP NPDES Permit: Document Type: Permit Issuance (Wasteload Allocation` Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Return Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: May 14, 1992 This document is printed on reuse paper - ignore any content on the re‘rerse side NPDES WASTE LOAD ALLOCATION PERMIT NO.: NC0021946 PERMITTEE NAME: FACILITY NAME: Town of Rosman Rosman WWTP Facility Status: Existing Permit Status: Renewal Major Minor Pipe No.: 001 Design Capacity: 0.09 MGD Domestic (% of Flow): 100 % Industrial (% of Flow): Comments: refer: Basinwide / Streamline WLA file at front of subbasin RECEIVING STREAM: the French Broad River Class: WS-III-Trout Sub -Basin: 04-03-01 Reference USGS Quad: G7NE County: Transylvania Regional Office: Asheville Regional Office (please attach) Previous Exp. Date: 10/31/92 Treatment Plant Class: class II Classification changes within three miles: Change to C-Trout at American Thread Company, Inc. Requested by: / Prepared by: Reviewed • : Randy Kepler Date: 3/10/92 Date: 67/379 Z- tB$)77 Date: v Modeler Date Rec. # Drainage Area (mi ) ,' ?, 2' Avg. Streamflow (cfs): 2 9° 7Q10 (cfs) SS,"S' Winter 7Q10 (cfs) 63. 7 30Q2 (cfs) 96.s --- Toxicity Limits: IWC % Acute/Chronic Instream Monitoring: Parameters Upstream Location Downstream Location Effluent Characteristics Summer Winter BOD5 (mg/1) .30 NH3-N (mg/1) r D.O. (mg/1) .1r TSS (mg/1) 3 F. Col. (/100 ml) zoo pH (SU) G _ 9 6e Y00 crf ...-e ED . PLO Comments: l�tz E:c� c� I��eIL'1 d RETURN TO TECHNICAL SERVICES BY: Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: S ubbasin: County: Regional Office: Requestor: Date of Request: Topo Quad: FACT SHEET FOR WASTELOAD ALLOCATION Rosman WWTP NC0021946 Domestic - 100% Existing Renewal French Broad River WSIII- Trout 040301 Transylvania Asheville Kepler 3/11/92 G7NE Request # 6817 Stream Characteristic: USGS # Date: Drainage Area (mi2): Summer 7Q10 (cfs): Winter 7Q10 (cfs): Average Flow (cfs): 30Q2 (cfs): IWC (%): 67.9 55.5 63.4 240 96.5 0.25 Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) Facility requesting renewal of existing NPDES permit. Tech Support recommends renewal of existing limits. Speecial,,Schedule Requirements and additional comments from Reviewers: Recommended by: Reviewed by Instream Assessment: Date: Regional Su v�sor: Q � �"I J `'yam" Date: 3P 9 Date:_4/14/92_ Date: ngineering: Date: mive2coelter..o $ ater APR24'0'3'7 Re?,i3nal G�ite ;shevi !she mi lte, tknrth Ca(O imr 2 CONVENTIONAL PARAMETERS Existing Limits: Monthly Average , Summer Winter Wasteflow (MGD): 0.09 BOD5 (mg/1): 30 NH3N (mg/1): monitor DO (mg/1): nr TSS (mg/1): 30 Fecal Col. (/100 ml): 1000 pH (SU): 6-9 Residual Chlorine (14/1): 800 Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Recommended Limits: Monthly Average Summer Winter WQ or EL Wasteflow (MGD): 0.09 BOD5 (mg/1): 30 NH3N (mg/1): monitor DO (mg/1): nr TSS (mg/1): 30 Fecal Col. (/100 ml): 200 pH (SU): 6-9 Residual Chlorine (µg/1): 800 Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Limits Changes Due To: Parameter(s) Affected Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow Other (onsite toxicity study, interaction, etc.) Instream data New regulations/standards/procedures Fecal Coliform New facility information X Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed. OR No parameters are water quality limited, but this discharge may affect future allocations. 3 MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS Adequacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Special Instructions or Conditions Wasteload sent to EPA? (Major) _ N (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? (Y or N) If yes, explain with attachments. /3.4.-e4L vo3 fr14,4.6 h.is, A-1 • ra- 3 • ,r , o town of rosman wwtp AMMONIA ANALYSIS 7Q10: 55.5000 cfs NH3 Effl. Conc: 28.0000 mg/1 AL (1/1.8 mg/1) : 1000.00 ug/1 Upstream NH3 Conc.: 220.0000 ug/1 Design Flow: 0.0900 MGD Predicted NH3 Downstream: 289.65 ug/1 0.289650 mg/1 NH3 Limit: 311322.5 ug/1 311.3225 mg/1 AMMONIA ANALYSIS (WINTER) 7Q10: 63.4000 cfs NH3 Effl. Conc: 28.0000 mg/1 AL (1/1.8 mg/1) : 1800.00 ug/1 Upstream NH3 Conc.: 220.0000 ug/1 Design Flow: 0.0900 MGD Predicted NH3 Downstream: 280.99 ug/1 0.280990 mg/1 NH3 Limit: 719878.8 ug/1 719.8788 mg/1 rosman wwtp CHLORINE ANALYSIS 7Q10: 55.5000 cfs CL2 Effl. Conc: 0.5000 mg/1 AL (17/19 ug/1) : 17.0000 ug/1 Upstream CL2 Conc.: 0.0000 ug/1 Design Flow: 0.0900 MGD Predicted CL2 Downstream: 1.25 ug/1 0.001253 mg/1 CL2 Limit: 6780.440 ug/1 6.780440 mg/1