Loading...
HomeMy WebLinkAboutNC0006254_Groundwater Monitoring Report December 2015_20151230AECOM 919.461.1100 tel 1600 Perimeter Park Drive, Suite 400 919.461.1415 fax Morrisville, NC 27560 Memorandum To Brett Laverty, NCDEQ Division of Water Resources, Water Quality Regional Operations, Asheville Regional Office Page 1 CC David Day, Sealed Air Corporation; Dave Hallock, Blue Ridge Tissue Corporation Subject Summary of December 2015 Groundwater Monitoring From Maureen Conorozzo and Savannah Hingtgen, AECOM Date December 30, 2015 AECOM Technical Services of North Carolina, Inc. (AECOM) is submitting this memorandum on behalf of Sealed Air Corporation to summarize groundwater activities conducted on December 3, 2015 at the Blue Ridge Tissue Corporation facility located at 1427 Yadkin River Road in Patterson (Lenoir), North Carolina (Site). AECOM gauged site monitoring wells MW-1 through MW-8 on December 3, 2015. Depth to groundwater and groundwater elevation data, as measured during the December 2015 event, are provided in Table 1. Groundwater elevations were similar to those measured during previous sampling events. An analysis of groundwater flow direction will be provided in the annual groundwater monitoring report. Seven of the eight existing site monitoring wells were sampled during the December 2015 monitoring event; sampling was not required for well MW-5. Six of these monitoring wells (MW-1, MW-3, MW-4, MW-6, MW-7, and MW-8) were purged and sampled using a peristaltic pump and low-flow techniques. Monitoring well MW-2 was also purged and sampled using low-flow techniques, but a bladder pump was used instead of a peristaltic pump as the depth to water in well MW-2 (50.68 feet below top of casing) was beyond the limit of suction of the peristaltic pump. During purging of each well, water quality measurements were collected to evaluate well stabilization. Parameters pH, specific conductance, temperature, oxidation-reduction potential, and dissolved oxygen were measured using a multi-parameter water quality meter (YSI ProPlus) equipped with a flow-through cell, and turbidity measurements were collected using a portable turbidity meter (Micro TPW). Once water quality parameters stabilized, a groundwater sample was collected in laboratory provided pre-preserved sample containers, labeled, and placed on ice. The groundwater samples were analyzed for total iron, total manganese, and total barium by Prism Laboratories, Inc. During a previous sampling event in August 2014, a slight sheen was observed in purge water collected from MW-4. Therefore, purge water collected from MW-4 during sampling events conducted since August 2014 (July 2015 and December 2015) was closely examined for the presence of a sheen. No sheen was observed in either the July 2015 or December 2015 sampling events. AECOM 2 Analytical data for the December 2015 event is shown in Table 2, and the laboratory report is provided in Appendix A. Consistent with data collected from previous sampling events, the following summarizes the data collected during the December 2015 groundwater sampling event: Total iron exceeded the Title 15A North Carolina Administrative Code, Subchapter 2L Groundwater Quality Standard (2L Standard) of 0.3 milligrams per liter (mg/L) in samples collected from MW-1, MW-2, MW-3, MW-4, and MW-6. Total manganese exceeded the 2L Standard of 0.05 mg/L in samples collected from MW- 1, MW-2, MW-3, MW-4, and MW-6. Total barium was detected in all of the wells sampled, however concentrations exceeded the 2L Standard of 0.7 mg/L in samples collected from MW-2 only. Background well MW-6 samples contained concentrations of total manganese that exceed 2L Standards by 3 times. Total iron was detected slightly above the 2L Standard. Samples from property boundary monitoring wells MW-7 and MW-8 continue to be well within compliance of 2L Standards; total iron was not detected in either well. A more comprehensive annual groundwater monitoring report is forthcoming. Sincerely yours, Maureen Conorozzo, PG Savannah Hingtgen maureen.conorozzo@aecom.com savannah.higntgen@aecom.com Tables Table 1Monitoring Well Construction and Groundwater Elevation DataBlue Ridge Tissue Corporation - Patterson, North Carolina12/03/15 11.501,242.2112/03/1550.68 1,272.3512/03/1517.98 1,281.0412/03/154.06 1,243.1712/03/1513.20 1,272.2612/03/1527.90 1,313.6512/03/1517.93 1,256.4812/03/1512.18 1,240.96Notes:BLS - feet below land surface.BTOC - feet below top of casing.msl - feet above mean sea level. 1341.55MW-5 08/16/11 21 11-21 1285.461MW-6 08/06/14 29 19-29MW-4 08/13/09 15 5-15 1247.23MW-3 08/13/09 20 10-20 1299.02MW-2 08/12/09 50 40-50 1323.03MW-1 02/08/11 11 6-11 1253.711274.4120 10-20 1253.14MW-808/06/1408/06/1424MW-7 14-24Depth to Water (feet BTOC)Groundwater Elevation (ft msl)Well ID Date InstalledTotal Depth (feet BLS)Screened Interval (feet BLS)Top of Casing Elevation (feet msl)Date Water Level MeasuredAECOM Table 2Groundwater Analytical Results SummaryBlue Ridge Tissue Corporation - Patterson, North CarolinaSample ID Sample Date12/03/15 12/03/15 12/03/15 12/03/15 12/03/15 12/03/15 12/03/15Temperature (°C) NS 14.8 12.9 17.3 21.1 14.0 15.3 17.5pH (standard units) NS 6.1 6.3 6.3 6.3 4.9 6.0 5.9Specific Conductance (µS/cm) NS 461.6 757 503.4 283.2 29.7 110.5 212.7Dissoved Oxygen (mg/L) NS 0.19 0.74 0.16 0.14 5.02 3.79 4.19ORP (mV) NS -32 -43 -35 -66 256 242 250Turbidity (NTU) NS 2.59 8.5 8.62 1.77 2.0 0.0 0.0Total Iron (mg/L) 0.342 90 34 17 0.33< 0.10 < 0.10Total Barium (mg/L) 0.7 0.210.920.28 0.095 0.08 0.051 0.017Total Manganese (mg/L) 0.054.6 0.47 1.5 0.84 0.150.016 < 0.010Notes:Results reported for detected compounds onlySamples analyzed for total and dissolved iron by USEPA Method 6010Samples analyzed for ferrous iron by method SM3500-Fe DSamples analyzed for RCRA metals by USEPA Method 6010Bold samples indicate concentrations above the 2L Standard2L Standard - North Carolina groundwater quality standards established in Title 15A of the NCAC, Subchapter 2L, Section 0.202°C - degrees CelsiusµS/cm - microsiemens per centimetermg/L - milligrams per litermV - millivoltNA - Not analyzedNS - No standardNTU - RCRA - Resource Conservation Recovery ActUSEPA - United States Environmental Protection AgencyField ParametersAnalytical ParametersMW-6 MW-7 MW-82L StandardMW-2 MW-3 MW-4MW-1AECOM Appendix A Analytical Laboratory Report This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. NC Certification No. 402 SC Certification No. 99012 NC Drinking Water Cert No. 37735 Case Narrative 12/10/2015 AECOM Maureen Conorozzo 1600 Perimeter Park Drive, Suite 400 Morrisville, NC 27560 Project: Sealed Air Lab Submittal Date: 12/04/2015 Prism Work Order: 5120098 VA Certification No. 460211 DoD ELAP: L-A-B Accredited Certificate No. L2307 ISO/IEC 17025: L-A-B Accredited Certificate No . L2307 Please call if you have any questions relating to this analytical report. Respectfully, PRISM LABORATORIES, INC. President/Project Manager Reviewed ByRobbi A. Jones Robbi A. Jones President/Project Manager Data Qualifiers Key Reference: Method Detection LimitMDL Below Reporting LimitBRL Relative Percent DifferenceRPD *Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 1 of 13 Sample Receipt Summary 12/10/2015 Prism Work Order: 5120098 Client Sample ID MatrixLab Sample ID Date Sampled Date Received 5120098-01 12/03/15MW-1 12/04/15Water 5120098-02 12/03/15MW-2 12/04/15Water 5120098-03 12/03/15MW-3 12/04/15Water 5120098-04 12/03/15MW-4 12/04/15Water 5120098-05 12/03/15MW-6 12/04/15Water 5120098-06 12/03/15MW-7 12/04/15Water 5120098-07 12/03/15MW-8 12/04/15Water 5120098-08 12/03/15Dup-1 12/04/15Water Samples were received in good condition at 3.8 degrees C unless otherwise noted. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 2 of 13 Client ID ResultParameterMethod UnitsPrism ID Prism Work Order: 5120098 12/10/2015 Summary of Detections 0.21 mg/L5120098-01 MW-1 Barium *6010C 42 mg/L5120098-01 MW-1 Iron *6010C 4.6 mg/L5120098-01 MW-1 Manganese *6010C 0.92 mg/L5120098-02 MW-2 Barium *6010C 90 mg/L5120098-02 MW-2 Iron *6010C 0.47 mg/L5120098-02 MW-2 Manganese *6010C 0.28 mg/L5120098-03 MW-3 Barium *6010C 34 mg/L5120098-03 MW-3 Iron *6010C 1.5 mg/L5120098-03 MW-3 Manganese *6010C 0.095 mg/L5120098-04 MW-4 Barium *6010C 17 mg/L5120098-04 MW-4 Iron *6010C 0.84 mg/L5120098-04 MW-4 Manganese *6010C 0.080 mg/L5120098-05 MW-6 Barium *6010C 0.33 mg/L5120098-05 MW-6 Iron *6010C 0.15 mg/L5120098-05 MW-6 Manganese *6010C 0.051 mg/L5120098-06 MW-7 Barium *6010C 0.016 mg/L5120098-06 MW-7 Manganese *6010C 0.017 mg/L5120098-07 MW-8 Barium *6010C 0.28 mg/L5120098-08 Dup-1 Barium *6010C 34 mg/L5120098-08 Dup-1 Iron *6010C 1.6 mg/L5120098-08 Dup-1 Manganese *6010C This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 3 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-1 Prism Sample ID: 5120098-01 Prism Work Order: 5120098 Time Collected: 12/03/15 16:43 Time Submitted: 12/04/15 11:35 Total Metals 0.21 *6010C P5L012810.010 12/8/15 19:22 BGMmg/L 0.00070Barium 42 *6010C P5L012810.10 12/8/15 19:22 BGMmg/L 0.011Iron 4.6 *6010C P5L012810.010 12/8/15 19:22 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 4 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-2 Prism Sample ID: 5120098-02 Prism Work Order: 5120098 Time Collected: 12/03/15 14:25 Time Submitted: 12/04/15 11:35 Total Metals 0.92 *6010C P5L012810.010 12/8/15 19:30 BGMmg/L 0.00070Barium 90 *6010C P5L0128101.0 12/10/15 15:56 BGMmg/L 0.11Iron 0.47 *6010C P5L012810.010 12/8/15 19:30 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 5 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-3 Prism Sample ID: 5120098-03 Prism Work Order: 5120098 Time Collected: 12/03/15 15:33 Time Submitted: 12/04/15 11:35 Total Metals 0.28 *6010C P5L012810.010 12/8/15 19:38 BGMmg/L 0.00070Barium 34 *6010C P5L012810.10 12/8/15 19:38 BGMmg/L 0.011Iron 1.5 *6010C P5L012810.010 12/8/15 19:38 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 6 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-4 Prism Sample ID: 5120098-04 Prism Work Order: 5120098 Time Collected: 12/03/15 16:15 Time Submitted: 12/04/15 11:35 Total Metals 0.095 *6010C P5L012810.010 12/8/15 19:46 BGMmg/L 0.00070Barium 17 *6010C P5L012810.10 12/8/15 19:46 BGMmg/L 0.011Iron 0.84 *6010C P5L012810.010 12/8/15 19:46 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 7 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-6 Prism Sample ID: 5120098-05 Prism Work Order: 5120098 Time Collected: 12/03/15 11:44 Time Submitted: 12/04/15 11:35 Total Metals 0.080 *6010C P5L012810.010 12/8/15 19:54 BGMmg/L 0.00070Barium 0.33 *6010C P5L012810.10 12/8/15 19:54 BGMmg/L 0.011Iron 0.15 *6010C P5L012810.010 12/8/15 19:54 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 8 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-7 Prism Sample ID: 5120098-06 Prism Work Order: 5120098 Time Collected: 12/03/15 12:27 Time Submitted: 12/04/15 11:35 Total Metals 0.051 *6010C P5L012810.010 12/8/15 20:00 BGMmg/L 0.00070Barium BRL *6010C P5L012810.10 12/8/15 20:00 BGMmg/L 0.011Iron 0.016 *6010C P5L012810.010 12/8/15 20:00 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 9 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: MW-8 Prism Sample ID: 5120098-07 Prism Work Order: 5120098 Time Collected: 12/03/15 13:10 Time Submitted: 12/04/15 11:35 Total Metals 0.017 *6010C P5L012810.010 12/8/15 20:08 BGMmg/L 0.00070Barium BRL *6010C P5L012810.10 12/8/15 20:08 BGMmg/L 0.011Iron BRL *6010C P5L012810.010 12/8/15 20:08 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 10 of 13 Laboratory Report 12/10/2015 ResultParameter Batch ID Report Limit Analysis Date/Time MethodDilution Factor Units MDL Analyst 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Sample Matrix: Water Client Sample ID: Dup-1 Prism Sample ID: 5120098-08 Prism Work Order: 5120098 Time Collected: 12/03/15 00:00 Time Submitted: 12/04/15 11:35 Total Metals 0.28 *6010C P5L012810.010 12/8/15 20:15 BGMmg/L 0.00070Barium 34 *6010C P5L012810.10 12/8/15 20:15 BGMmg/L 0.011Iron 1.6 *6010C P5L012810.010 12/8/15 20:15 BGMmg/L 0.0016Manganese This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 11 of 13 12/10/15 Level II QC Report 1600 Perimeter Park Drive, Suite 400 Project: Sealed AirAECOM Morrisville, NC 27560 Attn: Maureen Conorozzo Prism Work Order: 5120098 Time Submitted: 12/4/2015 11:35:00AM Result Limit Reporting Units Level Spike Result Source %REC %REC Limits RPD RPD Limit Notes Analyte Total Metals - Quality Control Batch P5L0128 - 3010A Blank (P5L0128-BLK1)Prepared & Analyzed: 12/08/15 Barium mg/LBRL0.010 Iron mg/LBRL0.10 Manganese mg/LBRL0.010 LCS (P5L0128-BS1)Prepared & Analyzed: 12/08/15 Barium mg/L0.244 0.010 80-120 Iron mg/L4.91 0.10 80-120 Manganese mg/L0.247 0.010 80-120 Sample Extraction Data Prep Method: 3010A Lab Number Batch Date/TimeInitialFinal P5L01285120098-01 12/08/15 8:2550 50mL mL P5L01285120098-02 12/08/15 8:2550 50mL mL P5L01285120098-02 12/08/15 8:2550 50mL mL P5L01285120098-03 12/08/15 8:2550 50mL mL P5L01285120098-04 12/08/15 8:2550 50mL mL P5L01285120098-05 12/08/15 8:2550 50mL mL P5L01285120098-06 12/08/15 8:2550 50mL mL P5L01285120098-07 12/08/15 8:2550 50mL mL P5L01285120098-08 12/08/15 8:2550 50mL mL This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 12 of 13 Page 13 of 13