HomeMy WebLinkAboutNC0006254_Groundwater Monitoring Report December 2015_20151230AECOM 919.461.1100 tel
1600 Perimeter Park Drive, Suite 400 919.461.1415 fax
Morrisville, NC 27560
Memorandum
To Brett Laverty, NCDEQ Division of Water Resources, Water Quality
Regional Operations, Asheville Regional Office
Page 1
CC David Day, Sealed Air Corporation; Dave Hallock, Blue Ridge Tissue Corporation
Subject Summary of December 2015 Groundwater Monitoring
From Maureen Conorozzo and Savannah Hingtgen, AECOM
Date December 30, 2015
AECOM Technical Services of North Carolina, Inc. (AECOM) is submitting this memorandum on
behalf of Sealed Air Corporation to summarize groundwater activities conducted on December 3,
2015 at the Blue Ridge Tissue Corporation facility located at 1427 Yadkin River Road in Patterson
(Lenoir), North Carolina (Site).
AECOM gauged site monitoring wells MW-1 through MW-8 on December 3, 2015. Depth to
groundwater and groundwater elevation data, as measured during the December 2015 event, are
provided in Table 1. Groundwater elevations were similar to those measured during previous
sampling events. An analysis of groundwater flow direction will be provided in the annual
groundwater monitoring report.
Seven of the eight existing site monitoring wells were sampled during the December 2015
monitoring event; sampling was not required for well MW-5. Six of these monitoring wells (MW-1,
MW-3, MW-4, MW-6, MW-7, and MW-8) were purged and sampled using a peristaltic pump and
low-flow techniques. Monitoring well MW-2 was also purged and sampled using low-flow
techniques, but a bladder pump was used instead of a peristaltic pump as the depth to water in well
MW-2 (50.68 feet below top of casing) was beyond the limit of suction of the peristaltic pump.
During purging of each well, water quality measurements were collected to evaluate well
stabilization. Parameters pH, specific conductance, temperature, oxidation-reduction potential, and
dissolved oxygen were measured using a multi-parameter water quality meter (YSI ProPlus)
equipped with a flow-through cell, and turbidity measurements were collected using a portable
turbidity meter (Micro TPW). Once water quality parameters stabilized, a groundwater sample was
collected in laboratory provided pre-preserved sample containers, labeled, and placed on ice. The
groundwater samples were analyzed for total iron, total manganese, and total barium by Prism
Laboratories, Inc.
During a previous sampling event in August 2014, a slight sheen was observed in purge water
collected from MW-4. Therefore, purge water collected from MW-4 during sampling events
conducted since August 2014 (July 2015 and December 2015) was closely examined for the
presence of a sheen. No sheen was observed in either the July 2015 or December 2015 sampling
events.
AECOM 2
Analytical data for the December 2015 event is shown in Table 2, and the laboratory report is
provided in Appendix A. Consistent with data collected from previous sampling events, the
following summarizes the data collected during the December 2015 groundwater sampling event:
Total iron exceeded the Title 15A North Carolina Administrative Code, Subchapter 2L
Groundwater Quality Standard (2L Standard) of 0.3 milligrams per liter (mg/L) in samples
collected from MW-1, MW-2, MW-3, MW-4, and MW-6.
Total manganese exceeded the 2L Standard of 0.05 mg/L in samples collected from MW-
1, MW-2, MW-3, MW-4, and MW-6.
Total barium was detected in all of the wells sampled, however concentrations exceeded
the 2L Standard of 0.7 mg/L in samples collected from MW-2 only.
Background well MW-6 samples contained concentrations of total manganese that
exceed 2L Standards by 3 times. Total iron was detected slightly above the 2L Standard.
Samples from property boundary monitoring wells MW-7 and MW-8 continue to be well
within compliance of 2L Standards; total iron was not detected in either well.
A more comprehensive annual groundwater monitoring report is forthcoming.
Sincerely yours,
Maureen Conorozzo, PG Savannah Hingtgen
maureen.conorozzo@aecom.com savannah.higntgen@aecom.com
Tables
Table 1Monitoring Well Construction and Groundwater Elevation DataBlue Ridge Tissue Corporation - Patterson, North Carolina12/03/15 11.501,242.2112/03/1550.68 1,272.3512/03/1517.98 1,281.0412/03/154.06 1,243.1712/03/1513.20 1,272.2612/03/1527.90 1,313.6512/03/1517.93 1,256.4812/03/1512.18 1,240.96Notes:BLS - feet below land surface.BTOC - feet below top of casing.msl - feet above mean sea level. 1341.55MW-5 08/16/11 21 11-21 1285.461MW-6 08/06/14 29 19-29MW-4 08/13/09 15 5-15 1247.23MW-3 08/13/09 20 10-20 1299.02MW-2 08/12/09 50 40-50 1323.03MW-1 02/08/11 11 6-11 1253.711274.4120 10-20 1253.14MW-808/06/1408/06/1424MW-7 14-24Depth to Water (feet BTOC)Groundwater Elevation (ft msl)Well ID Date InstalledTotal Depth (feet BLS)Screened Interval (feet BLS)Top of Casing Elevation (feet msl)Date Water Level MeasuredAECOM
Table 2Groundwater Analytical Results SummaryBlue Ridge Tissue Corporation - Patterson, North CarolinaSample ID Sample Date12/03/15 12/03/15 12/03/15 12/03/15 12/03/15 12/03/15 12/03/15Temperature (°C) NS 14.8 12.9 17.3 21.1 14.0 15.3 17.5pH (standard units) NS 6.1 6.3 6.3 6.3 4.9 6.0 5.9Specific Conductance (µS/cm) NS 461.6 757 503.4 283.2 29.7 110.5 212.7Dissoved Oxygen (mg/L) NS 0.19 0.74 0.16 0.14 5.02 3.79 4.19ORP (mV) NS -32 -43 -35 -66 256 242 250Turbidity (NTU) NS 2.59 8.5 8.62 1.77 2.0 0.0 0.0Total Iron (mg/L) 0.342 90 34 17 0.33< 0.10 < 0.10Total Barium (mg/L) 0.7 0.210.920.28 0.095 0.08 0.051 0.017Total Manganese (mg/L) 0.054.6 0.47 1.5 0.84 0.150.016 < 0.010Notes:Results reported for detected compounds onlySamples analyzed for total and dissolved iron by USEPA Method 6010Samples analyzed for ferrous iron by method SM3500-Fe DSamples analyzed for RCRA metals by USEPA Method 6010Bold samples indicate concentrations above the 2L Standard2L Standard - North Carolina groundwater quality standards established in Title 15A of the NCAC, Subchapter 2L, Section 0.202°C - degrees CelsiusµS/cm - microsiemens per centimetermg/L - milligrams per litermV - millivoltNA - Not analyzedNS - No standardNTU - RCRA - Resource Conservation Recovery ActUSEPA - United States Environmental Protection AgencyField ParametersAnalytical ParametersMW-6 MW-7 MW-82L StandardMW-2 MW-3 MW-4MW-1AECOM
Appendix A
Analytical Laboratory Report
This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample
Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed
according to the referenced methods.
Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case
narrative.
NC Certification No. 402
SC Certification No. 99012
NC Drinking Water Cert No. 37735
Case Narrative
12/10/2015
AECOM
Maureen Conorozzo
1600 Perimeter Park Drive, Suite 400
Morrisville, NC 27560
Project: Sealed Air
Lab Submittal Date: 12/04/2015
Prism Work Order: 5120098
VA Certification No. 460211
DoD ELAP: L-A-B Accredited Certificate No. L2307
ISO/IEC 17025: L-A-B Accredited Certificate No . L2307
Please call if you have any questions relating to this analytical report.
Respectfully,
PRISM LABORATORIES, INC.
President/Project Manager
Reviewed ByRobbi A. Jones Robbi A. Jones
President/Project Manager
Data Qualifiers Key Reference:
Method Detection LimitMDL
Below Reporting LimitBRL
Relative Percent DifferenceRPD
*Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and
reporting limit indicated with a J.
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 1 of 13
Sample Receipt Summary
12/10/2015
Prism Work Order: 5120098
Client Sample ID MatrixLab Sample ID Date Sampled Date Received
5120098-01 12/03/15MW-1 12/04/15Water
5120098-02 12/03/15MW-2 12/04/15Water
5120098-03 12/03/15MW-3 12/04/15Water
5120098-04 12/03/15MW-4 12/04/15Water
5120098-05 12/03/15MW-6 12/04/15Water
5120098-06 12/03/15MW-7 12/04/15Water
5120098-07 12/03/15MW-8 12/04/15Water
5120098-08 12/03/15Dup-1 12/04/15Water
Samples were received in good condition at 3.8 degrees C unless otherwise noted.
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 2 of 13
Client ID ResultParameterMethod UnitsPrism ID
Prism Work Order: 5120098
12/10/2015
Summary of Detections
0.21 mg/L5120098-01 MW-1 Barium *6010C
42 mg/L5120098-01 MW-1 Iron *6010C
4.6 mg/L5120098-01 MW-1 Manganese *6010C
0.92 mg/L5120098-02 MW-2 Barium *6010C
90 mg/L5120098-02 MW-2 Iron *6010C
0.47 mg/L5120098-02 MW-2 Manganese *6010C
0.28 mg/L5120098-03 MW-3 Barium *6010C
34 mg/L5120098-03 MW-3 Iron *6010C
1.5 mg/L5120098-03 MW-3 Manganese *6010C
0.095 mg/L5120098-04 MW-4 Barium *6010C
17 mg/L5120098-04 MW-4 Iron *6010C
0.84 mg/L5120098-04 MW-4 Manganese *6010C
0.080 mg/L5120098-05 MW-6 Barium *6010C
0.33 mg/L5120098-05 MW-6 Iron *6010C
0.15 mg/L5120098-05 MW-6 Manganese *6010C
0.051 mg/L5120098-06 MW-7 Barium *6010C
0.016 mg/L5120098-06 MW-7 Manganese *6010C
0.017 mg/L5120098-07 MW-8 Barium *6010C
0.28 mg/L5120098-08 Dup-1 Barium *6010C
34 mg/L5120098-08 Dup-1 Iron *6010C
1.6 mg/L5120098-08 Dup-1 Manganese *6010C
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 3 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-1
Prism Sample ID: 5120098-01
Prism Work Order: 5120098
Time Collected: 12/03/15 16:43
Time Submitted: 12/04/15 11:35
Total Metals
0.21 *6010C P5L012810.010 12/8/15 19:22 BGMmg/L 0.00070Barium
42 *6010C P5L012810.10 12/8/15 19:22 BGMmg/L 0.011Iron
4.6 *6010C P5L012810.010 12/8/15 19:22 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 4 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-2
Prism Sample ID: 5120098-02
Prism Work Order: 5120098
Time Collected: 12/03/15 14:25
Time Submitted: 12/04/15 11:35
Total Metals
0.92 *6010C P5L012810.010 12/8/15 19:30 BGMmg/L 0.00070Barium
90 *6010C P5L0128101.0 12/10/15 15:56 BGMmg/L 0.11Iron
0.47 *6010C P5L012810.010 12/8/15 19:30 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 5 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-3
Prism Sample ID: 5120098-03
Prism Work Order: 5120098
Time Collected: 12/03/15 15:33
Time Submitted: 12/04/15 11:35
Total Metals
0.28 *6010C P5L012810.010 12/8/15 19:38 BGMmg/L 0.00070Barium
34 *6010C P5L012810.10 12/8/15 19:38 BGMmg/L 0.011Iron
1.5 *6010C P5L012810.010 12/8/15 19:38 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 6 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-4
Prism Sample ID: 5120098-04
Prism Work Order: 5120098
Time Collected: 12/03/15 16:15
Time Submitted: 12/04/15 11:35
Total Metals
0.095 *6010C P5L012810.010 12/8/15 19:46 BGMmg/L 0.00070Barium
17 *6010C P5L012810.10 12/8/15 19:46 BGMmg/L 0.011Iron
0.84 *6010C P5L012810.010 12/8/15 19:46 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 7 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-6
Prism Sample ID: 5120098-05
Prism Work Order: 5120098
Time Collected: 12/03/15 11:44
Time Submitted: 12/04/15 11:35
Total Metals
0.080 *6010C P5L012810.010 12/8/15 19:54 BGMmg/L 0.00070Barium
0.33 *6010C P5L012810.10 12/8/15 19:54 BGMmg/L 0.011Iron
0.15 *6010C P5L012810.010 12/8/15 19:54 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 8 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-7
Prism Sample ID: 5120098-06
Prism Work Order: 5120098
Time Collected: 12/03/15 12:27
Time Submitted: 12/04/15 11:35
Total Metals
0.051 *6010C P5L012810.010 12/8/15 20:00 BGMmg/L 0.00070Barium
BRL *6010C P5L012810.10 12/8/15 20:00 BGMmg/L 0.011Iron
0.016 *6010C P5L012810.010 12/8/15 20:00 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 9 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: MW-8
Prism Sample ID: 5120098-07
Prism Work Order: 5120098
Time Collected: 12/03/15 13:10
Time Submitted: 12/04/15 11:35
Total Metals
0.017 *6010C P5L012810.010 12/8/15 20:08 BGMmg/L 0.00070Barium
BRL *6010C P5L012810.10 12/8/15 20:08 BGMmg/L 0.011Iron
BRL *6010C P5L012810.010 12/8/15 20:08 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 10 of 13
Laboratory Report
12/10/2015
ResultParameter Batch
ID
Report
Limit
Analysis
Date/Time
MethodDilution
Factor
Units MDL Analyst
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Sample Matrix: Water
Client Sample ID: Dup-1
Prism Sample ID: 5120098-08
Prism Work Order: 5120098
Time Collected: 12/03/15 00:00
Time Submitted: 12/04/15 11:35
Total Metals
0.28 *6010C P5L012810.010 12/8/15 20:15 BGMmg/L 0.00070Barium
34 *6010C P5L012810.10 12/8/15 20:15 BGMmg/L 0.011Iron
1.6 *6010C P5L012810.010 12/8/15 20:15 BGMmg/L 0.0016Manganese
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 11 of 13
12/10/15
Level II QC Report
1600 Perimeter Park Drive, Suite 400
Project: Sealed AirAECOM
Morrisville, NC 27560
Attn: Maureen Conorozzo
Prism Work Order: 5120098
Time Submitted: 12/4/2015 11:35:00AM
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Total Metals - Quality Control
Batch P5L0128 - 3010A
Blank (P5L0128-BLK1)Prepared & Analyzed: 12/08/15
Barium mg/LBRL0.010
Iron mg/LBRL0.10
Manganese mg/LBRL0.010
LCS (P5L0128-BS1)Prepared & Analyzed: 12/08/15
Barium mg/L0.244 0.010 80-120
Iron mg/L4.91 0.10 80-120
Manganese mg/L0.247 0.010 80-120
Sample Extraction Data
Prep Method: 3010A
Lab Number Batch Date/TimeInitialFinal
P5L01285120098-01 12/08/15 8:2550 50mL mL
P5L01285120098-02 12/08/15 8:2550 50mL mL
P5L01285120098-02 12/08/15 8:2550 50mL mL
P5L01285120098-03 12/08/15 8:2550 50mL mL
P5L01285120098-04 12/08/15 8:2550 50mL mL
P5L01285120098-05 12/08/15 8:2550 50mL mL
P5L01285120098-06 12/08/15 8:2550 50mL mL
P5L01285120098-07 12/08/15 8:2550 50mL mL
P5L01285120098-08 12/08/15 8:2550 50mL mL
This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc.
449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543
Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 12 of 13
Page 13 of 13