Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG240016_2021 DMR_20220126
EaBURG co •F G r _ � RTy CAROy MECKLENBURG COUNTY Land Use & Environmental Services Agency Solid Waste January 25, 2022 DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville, NC 28115 Attention: DEMLR Stormwater Program Subject: Discharge Monitoring Report Mecklenburg County Compost Central — Certificate of Coverage No. NCG240016 Dear Central Files: Please find enclosed the Discharge Monitoring Report, December 2021, for Mecklenburg County Compost Central, a Type I facility located at 5631 West Blvd, North Carolina. If you have any questions, please contact me at 704-634-7705 or by email at khaliem.adams@mecklenbur cg ountync.gov. Sincerely, Khaliem Adams Solid Waste Environmental Specialist Enclosed: 2021 DMR PEOPLE • PRIDE PROGRESS • PARTNERSHIP 2145 Suttle Avenue Charlotte, North Carolina 28208 www.wipeoutwaste.com NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG240000 Compost Operations Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG24 0016 Person Collecting Samples: Khaliem Adams Facility Name: Mecklenburg County Compost Central Laboratory Name: Pace Analytical Facility County: Mecklenburg Laboratory Cert. No.: Discharge during this period: ✓❑ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑✓ Yes ❑ No If so, which Tier (I, II, or III)? Tier 2 A copy of this DMR ben uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ❑✓ Yes ❑ No Date Uploaded: ( h s c od� Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall2 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class N/A Date Sample Collected MM/DD/YYYY 12/21/2021 46529 24-Hour Rainfall in inches 0.88 inches C0530 TSS in mg/L (100) 5.0 00340 Chemical Oxygen Demand (120) 204 31615 Fecal Coliform in colonies per 100 ml 6000 (1000) 600 Total Nitrogen in mg/L (30) 3.0 665 Total Phosphorus in mg/L (2) 0.50 400 pH in standard units (6.0-9.0) 8.51 Copper, total recoverable in mg/L 01119 (0.010) 0.022 Lead, total recoverable in mg/ L 01051 (0.075) <0.0050 Zinc, total recoverable in mg/ L 01094 (0.126) 0.036 Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average 00552 Non -Polar Oil & Grease in mg/L (15) <4.9 Estimated New Motor/Hydraulic Oil NCOIL Usage in gal/month 75ga1/month Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature otPermittee or Delegated Authorized Individual Date Email Address Phone Number Facility Name I Sample Location I Sample Time I pH I Date I Device Used to Sample Mecklenburg County Compost Central Outfall 2 1313 8.51 12/21/2021 Horiba pH meter aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 January 07, 2022 Darren Steinhilber Mecklenburg County Solid Waste 2145 Suttle Ave Charlotte, NC 28208 RE: Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 Dear Darren Steinhilber: Enclosed are the analytical results for sample(s) received by the laboratory on December 21, 2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Khaliem Adams, Meclenburg County Solid Waste REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 CERTIFICATIONS South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water#: LA029 Virginia/VELAP Certification #: 460221 South Carolina Laboratory ID: 99030 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Pace Project No.: COMPOST CENTRAL 1 92579271 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92579271001 OUTFALL 2 EPA 1664B ICO 1 PASI-C EPA 1664B ICO 1 PASI-C EPA 200.7 Rev 4.4 1994 CBV 3 PASI-A SM 9222D-2015 KDF 1 PASI-C SM 254OD-2015 ZMC 1 PASI-A TKN+NO3+NO2 Calculation DMN 1 PASI-A EPA 351.2 Rev 2.0 1993 MFO 1 PASI-A EPA 353.2 Rev 2.0 1993 KDF1 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 5220D-2011 JP1 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 Sample: OUTFALL 2 Lab ID: 92579271001 Collected: 12/21/21 13:25 Received: 12/21/21 13:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.9 1 12/23/21 09:15 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 4.9 1 12/23/21 09:15 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper 0.022 mg/L 0.0050 1 12/30/21 15:01 01/07/22 01:25 7440-50-8 Lead ND mg/L 0.0050 1 12/30/21 15:01 01/07/22 01:25 7439-92-1 Zinc 0.036 mg/L 0.010 1 12/30/21 15:01 01/07/22 01:25 7440-66-6 MBIO 9222D Fecal Coliform CHT Analytical Method: SM 9222D-2015 Preparation Method: SM 9222D-2015 Pace Analytical Services - Charlotte Fecal Coliforms 6000 CFU/100 mL 1.0 1 12/21/21 15:54 12/22/21 14:02 u2 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 5.0 mg/L 5.0 1 12/22/21 15:52 Total Nitrogen Calculation Analytical Method: TKN+NO3+NO2 Calculation Pace Analytical Services - Asheville Total Nitrogen 3.0 mg/L 0.52 1 01/05/22 10:17 351.2 Total Kjeldahl Nitrogen Analytical Method: EPA 351.2 Rev 2.0 1993 Preparation Method: EPA 351.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, Kjeldahl, Total 2.8 mg/L 0.50 1 01/03/22 22:09 01/05/22 06:01 7727-37-9 353.2 Nitrogen, NO2/NO3 pres. Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, NO2 plus NO3 0.15 mg/L 0.040 1 12/28/21 13:04 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services - Asheville Phosphorus 0.50 mg/L 0.050 1 12/27/2120:19 12/27/2122:08 7723-14-0 5220D COD Analytical Method: SM 5220D-2011 Preparation Method: SM 5220D-2011 Pace Analytical Services - Asheville Chemical Oxygen Demand 204 mg/L 25.0 1 12/24/21 01:33 12/24/21 04:45 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 667986 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92579271001 METHOD BLANK: 3499446 Associated Lab Samples: 92579271001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 3499447 Parameter Units Oil and Grease mg/L MATRIX SPIKE SAMPLE: 3499448 Parameter Units Oil and Grease mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 12/23/2109:15 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 40 33.4 84 78-114 35684886001 Spike MS MS % Rec Result Cone. Result % Rec Limits Qualifiers 1.1 U 39.6 32.8 81 78-114 SAMPLE DUPLICATE: 3499449 35684884001 Dup Parameter Units Result Result Oil and Grease mg/L 1 AJ 1.51 RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 667984 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92579271001 METHOD BLANK: 3499433 Associated Lab Samples: 92579271001 Parameter Units Total Petroleum Hydrocarbons mg/L LABORATORY CONTROL SAMPLE: 3499434 Parameter Units Total Petroleum Hydrocarbons mg/L MATRIX SPIKE SAMPLE: 3499435 Parameter Units Total Petroleum Hydrocarbons mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 12/23/2109:15 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 20 15.7 78 64-132 35684886001 Spike MS MS % Rec Result Cone. Result % Rec Limits Qualifiers 5.01-1 19.8 15.4 74 64-132 SAMPLE DUPLICATE: 3499436 35684884001 Dup Parameter Units Result Result Total Petroleum Hydrocarbons mg/L 5.01-1 ND RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 668895 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92579271001 METHOD BLANK: 3503165 Matrix: Water Associated Lab Samples: 92579271001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Copper mg/L ND 0.0050 01/07/22 00:01 Lead mg/L ND 0.0050 01/07/22 00:01 Zinc mg/L ND 0.010 01/07/22 00:01 LABORATORY CONTROL SAMPLE: 3503166 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Copper mg/L 0.5 0.54 108 85-115 Lead mg/L 0.5 0.50 100 85-115 Zinc mg/L 0.5 0.50 101 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3503167 3503168 MS MSD 92578424001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L 0.14 0.5 0.5 0.67 0.68 106 107 70-130 1 Lead mg/L ND 0.5 0.5 0.50 0.51 100 101 70-130 1 Zinc mg/L ND 0.5 0.5 0.53 0.53 104 104 70-130 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3503169 3503170 MS MSD 92578969001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L 88.7 0.5 0.5 0.59 0.58 100 99 70-130 1 ug/L Lead mg/L ND 0.5 0.5 0.49 0.49 98 98 70-130 0 Zinc mg/L 39.8 0.5 0.5 0.54 0.53 99 98 70-130 1 ug/L Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 667945 Analysis Method: SM 9222D-2015 QC Batch Method: SM 9222D-2015 Analysis Description: 9222D Fecal Coliform(MF) - CHT Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92579271001 METHOD BLANK: 3499121 Associated Lab Samples: 92579271001 Parameter Fecal Coliforms SAMPLE DUPLICATE: 3499122 Parameter Fecal Coliforms Matrix: Water Blank Reporting Units Result Limit Analyzed Qualifiers CFU/100 mL ND 1.0 12/22/21 14:02 92579412003 Dup Units Result Result RPD Qualifiers CFU/100 mL ND ND Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 667975 Analysis Method: SM 2540D-2015 QC Batch Method: SM 254OD-2015 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92579271001 METHOD BLANK: 3499348 Associated Lab Samples: 92579271001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 3499349 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 3499582 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 12/22/2115:44 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 246 98 90-110 92578799001 Dup Result Result RPD Qualifiers 76.0 79.0 4 SAMPLE DUPLICATE: 3499583 92578953002 Dup Parameter Units Result Result Total Suspended Solids mg/L 54.0 46.0 RPD Qualifiers 16 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 669501 Analysis Method: EPA 351.2 Rev 2.0 1993 QC Batch Method: EPA 351.2 Rev 2.0 1993 Analysis Description: 351.2 TKN Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92579271001 METHOD BLANK: 3505636 Associated Lab Samples: 92579271001 Parameter Units Nitrogen, Kjeldahl, Total mg/L LABORATORY CONTROL SAMPLE: 3505637 Parameter Units Nitrogen, Kjeldahl, Total mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.50 01/05/22 01:55 Spike 1-CS LCS % Rec Cone. Result % Rec Limits Qualifiers 10 9.7 97 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3505640 3505641 MS MSD 92578242001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 79.6 10 10 92.5 98.7 129 192 90-110 7 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3506004 3506005 MS MSD 92578242002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 3.1 10 10 14.6 15.7 115 126 90-110 7 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 668656 Analysis Method: EPA 353.2 Rev 2.0 1993 QC Batch Method: EPA 353.2 Rev 2.0 1993 Analysis Description: 353.2 Nitrate + Nitrite, preserved Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92579271001 METHOD BLANK: 3502028 Associated Lab Samples: 92579271001 Parameter Units Nitrogen, NO2 plus NO3 mg/L LABORATORY CONTROL SAMPLE: 3502029 Parameter Units Nitrogen, NO2 plus NO3 mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.040 12/28/2112:33 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.4 96 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3502030 3502031 MS MSD 92578646001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 12.5 2.5 2.5 15.5 15.5 121 123 90-110 0 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3502032 3502033 MS MSD 92578681001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 14.9 2.5 2.5 16.9 16.9 79 78 90-110 0 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 668596 Analysis Method: EPA 365.1 Rev 2.0 1993 QC Batch Method: EPA 365.1 Rev 2.0 1993 Analysis Description: 365.1 Phosphorus, Total Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92579271001 METHOD BLANK: 3501909 Associated Lab Samples: 92579271001 Parameter Units Phosphorus mg/L LABORATORY CONTROL SAMPLE: 3501910 Parameter Units Phosphorus mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.050 12/27/2121:51 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.5 100 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3501911 3501912 MS MSD 92578713001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L ND 2.5 2.5 2.5 2.6 100 102 90-110 2 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3501913 3501914 MS MSD 92578713002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L ND 2.5 2.5 2.6 2.6 102 102 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 12 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 QC Batch: 668367 Analysis Method: SM 5220D-2011 QC Batch Method: SM 5220D-2011 Analysis Description: 5220D COD Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92579271001 METHOD BLANK: 3501144 Associated Lab Samples: 92579271001 Parameter Units Chemical Oxygen Demand mg/L LABORATORY CONTROL SAMPLE: 3501145 Parameter Units Chemical Oxygen Demand mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 25.0 12/24/2104:41 Spike 1-CS LCS % Rec Cone. Result % Rec Limits Qualifiers 750 807 108 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3501146 3501147 MS MSD 92578087001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 88.8 100 100 204 204 115 115 90-110 0 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3501148 3501149 MS MSD 92579269003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 69.6 100 100 187 185 118 115 90-110 1 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 13 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: COMPOST CENTRAL 1 Pace Project No.: 92579271 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. u2 Colonies are too numerous to count. Actual result may be greater than reported. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /07/2022 03:17 PM without the written consent of Pace Analytical Services, LLC. Page 14 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pace Project No.: COMPOST CENTRAL 1 92579271 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92579271001 OUTFALL 2 EPA 1664B 667986 92579271001 OUTFALL 2 EPA 1664B 667984 92579271001 OUTFALL 2 EPA 200.7 Rev 4.4 1994 668895 EPA 200.7 Rev 4.4 1994 669317 92579271001 OUTFALL 2 SM 9222D-2015 667945 SM 9222D-2015 667946 92579271001 OUTFALL 2 SM 254OD-2015 667975 92579271001 OUTFALL 2 TKN+NO3+NO2 669887 Calculation 92579271001 OUTFALL 2 EPA 351.2 Rev 2.0 1993 669501 EPA 351.2 Rev 2.0 1993 669566 92579271001 OUTFALL 2 EPA 353.2 Rev 2.0 1993 668656 92579271001 OUTFALL 2 EPA 365.1 Rev 2.0 1993 668596 EPA 365.1 Rev 2.0 1993 668643 92579271001 OUTFALL 2 SM 5220D-2011 668367 SM 5220D-2011 668389 Date: 01/07/2022 03:17 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 15 of 18 n _ aceAnalytical Document Name: Sample Condition Upon Receipt (SCUR) Document Revised: November 15, 2021 Page 1 of 2 Document No.: Issuing Authority: F-CAR-CS-033-Rev.08 Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersville`2 Raleigh❑ Mechanicsville[] Atlanta ❑ Kernersville❑ Sample Condition Client Blame: Upon Receipt Prqject #: V(- ut"v l, Wt-b []UP Ex U5P ❑Cienttaurler: ❑❑L ❑ Commercial Race ❑Cfther: Custody Seal Present? Elves IE]No Seals Intact? []Yes ZNo W0#:92579271 III III III III III I III III 92979271 L [J) J Date/initials Person Examining Contents. Packing Material: ❑Bubble Wrap 1�81,lbble Bags []None ❑ Other Biological Tissue Frozen? Thermometer: �f/1� 11 �, PtNet ❑Blue ❑[one []Yes ❑No�-. N/A 91R Gun ID: l �[ l Type of Ice: Correction Factor: Cooler Temp: C 7 Add/Subtract (°C) Temp should be above freezing to VC -7 [—]Samples out of temp criteria. Samples on ice, cooling process Coal er-Tennpr arrected-('Cl: a gun USDA Regulated Soil (J N/A, water samplel Did samoles originate in a quarantine zone within the United States: CA, NY, or SC (check mapsl? Did samples originate from a foreign source (internationally, []Yes No inCluaingHawau ano Fuerto MiColr Ures IJNG Comments/Discrepancy: Chain of Custody Present? JDYes [-]No ❑N/A 1. Samples Arrived within Hold Time? Oyes []No []N/A 2. Short Hold Time Analysis (02 hr.)? ores []No N/A 3. Rush Turn Around Time Requested? ❑..rYes jRfi0 ❑N/A 4. SufficientVolume? C Yes []No ❑N/A 5. Correct Containers Used? es ❑No ❑N/A 5. -Pace Containers Used? es QNa ❑NIA Containers Intact? Myes []NO N/A 7. Dissolved analysis: Samples Field Filtered? []Yes [-]No NIA a. Sample Labels Match COO j?Yes []No ❑N/A 9. �._ A -Includes Date/T"ime/iD/Analysis Matrix: Heads ace in VOA Vials (>5-Gmm)? ❑Yes nrNG . NIA 10. Trip Blank Present? [—]Yes No ❑N/A Trip Blank Custody Seals Present? []Yes ❑No /A COMMENTS/SAMPLE DISCREPANCY Lot ID of split containers: CLIENT NOT Person contacted: Project Manager SCURF Review: Project Manager SRF Review: Date/Time: Date: Date: Field Data Required? ❑Yes []NO Page 16 of 18 Document Name: Document Revised: November 15, 2021 Sample Condition Upon Receipt {SCURI Page 2 of 2 aceAria[X cal Document Nb..' Issuing Authority: F-CAR-CS-033-Rev.08 Pace Carolinas Quality Office *Check mark top half of box If pH and/or dechtorination is Project It wog ; 92579271 verified and within the acceptance range for preservation Duo Date: 12/29/21 samples. P�' MWB Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg CLIENT. 92-MECi( CO **Bottom half of box is to list number of bottles in u _ s N a Z Q Z Z Z Z y V V 1 L V V OZf ^ y 'ap �. V N y G Z $ v a u ar w a do v m °r, Y A d a a O A O a O O Q O p c N E z ry C a C O, ry Z z b G U 7 ry = Q _ � M a , c = S Z d = x J U N u Idv_ M U y _V �+ L E $ z m m m +u' A In N G a a 6 M a a m M a a a E E E ¢ E ¢ Ln ru D7 O Q 4 Q J tL E E E m E E E E a w o d E m E E ,n a o g n . c A z = ,n in o a MEN NMI NMI 111 NMI NMI Sol Z_+ U M d c 7 O J } E E o p y l7 a al+ 2 N f3 m i Q z b a y J E � Q ❑ N ~ Z a Y y J E E o N it d 7 v E E 4 io '} c o '_ E a ` a z N at 0. C � E E o cn —� Y L• F Q p a cn ? 4 > n 7 � H 'A ccQ PH Adjustment Log for Preserved Samples Sample 1D rype of Preservatives PH upon receipt Date preservation adjusted Time preservation Amaunt of Preservative Lot # adjusted I added Note: whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina OEHNR Certification Office ti out of hold, incorrect preservative, out of temp, incorrect containers. Page 17 of 18 i i i 'e s m= a o m m to cx o oa .t rn k ITEM # .B C O { 58, O N N y d O 7 O C Z 0 J n ^ @ � N pin 3 m 3 � h a� v 0 cn 3 aim 3 n = �• en 0 m y r G In o n eV I m t _C CA m N 7 d v �.J o K N G e d safe=" n - f � m d 3 C O C � y - p C rjr N 3 a EL a C MATRIX CODE (see valid codes to tall) it m D 1 SAMPa.E TYPE (G=GRAB C=COMP) a y 3 c S] _ r m h < t' m ° a X a to 3 ni n m z r z m tCL a z o m m m m v fD 0 O m> n CI z d $ v Z 0 o n N v; m m o ' O m r- A p Z .nj f-1 SAMPLE TEMP AT COLLECTION v t7In in m IY OF CONTAINERS d y d a o g y p a m `c C m L)npreserved n p N v N J W a a ° .. n—1 g 2 H2SO4 0 7# HNO3 a� m 3 G SII N p y S HCl m o p 3 O0 a 'L NaOH v 1 n p C 7 .� Na2S203 N d o Methanol N Z rt 0iher Q m d — > m a m Analyses Test YIN " ^? X C00ITota1 Phosphcrus v X TSS f° m y m to X Fecal Coli �, y nx > Total Nitrogen (TKN+nilrale m 3 07 0 > 200.7 ICP Metals v N m x 0&G 1664 $ n (^� p X TPH SGT-HEM 1664 3 3 v iD m C to pp� hi m � b b CL n n j t z c m m � Q � N TEMP in C �i N Residual Chlorine (YIN) # Received on �C \ o ; 0 o ° Ice E a (YIN) E a o Custody o Sealed c _ o C6eler u Y!N z sam6= pies Intact (YIN) R Page 18 of 18 KI..r'.. Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https://deg.nc.eov/about/divisions/enerev-mineral-land- resources/energy-mineral-1 and-permits/stormwater-permits/nudes-industrial-sw#tab-4 Permit No.: N/C/C / &l 101010101 or Certificate of Coverage No.: N/CIG/ S� Facility Name: County: I �-r► �� Phone N. J 0 1—� j r Q Inspector: i Date of Inspection: a 01 o2©a l Time of Inspection: �✓ Total Event Precipitation (inches): 01 01h All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: of Permittee or Designee) 1. Outfall Description: Outfall No. 02 Structure (pipe, ditch, etc.): Receiving Stream: Describe the industrial activities that occur within the outfall drainage area: MA,i✓J Page 1 of 2 SWU-242, Last modified 07/28/2017 2. Color: Describe the color of (light, medium, dark) as descriptors: _ 3. Odor: Descri any chlorine odor, etc.): basic colors (red, brown, blue, etc.) and tint odors that the discharge may have (i.e., smells strongly of oil, weak 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: DI2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 f`f 7. Is there any foam in the stormwater discharge. O Yes 8. Is there an oil sheen in the stormwater discharge? OYes 9. Is there evidence of erosion or deposition at the outfall? O Yes ZNo. 10. Other Obviou s Indicators of Stormwatte�r Pollution: List and describe 004cn��(/ ,,4, o f —� , Iq Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SVJU-242, Last modified 07/28/2017 Photo