HomeMy WebLinkAboutSW3200202_Plansheet C9.03 - SCM Planting Plan_20220216STORMWATER CONTROL MEASURE 'A' LANDSCAPE PLAN
LEGEND
QTY. SYM. SCIENTIFIC NAME COMMON NAME HATCH TYPE MIN. SPACING
265 CT CAREXTENERA
QUILL SEDGE
293 ED EUPATORIADELPHUS DUBIUS DWARF JOE PYE WEED
284 HL HIBISCUS LAEVIS
SEEDBED PREPARATION
SCARLET ROSE MALLOW
4" CONTAINER
4" CONTAINER
4" CONTAINER
1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE.
2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH.
3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM.
4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL.
5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP.
6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER.
7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH.
8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER
PERMANENT COVER IS ESTABLISHED.
9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT
TEMPORARY SEEDING SCHEDULE
SEEDING DATE SEEDING MIXTURE APPLICATION RATE
JAN 1- MAY 1 RYE (GRAIN) 120 LBS/AC
KOBE LESPEDEZA 50 LBS/AC
MAY 1 - AUG 15 GERMAN MILLET 40 LBS/AC
AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC
SOILAMENDMENTS
FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10
FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC).
MULCH
APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH
BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.
MAINTENANCE
JAN 1- AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH
IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE.
AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF
IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN
LATE FEBRUARY OR EARLY MARCH.
�L���J:��la�hlf•IZ�7:7_li'�9x��71►[e�Yi]:I��1�1��iI►1�'��i�/:Ix►U7�l�6Y►[��tiIi]:T:7Xii�lil�L9�i�:1�]�:7►/►_��1�►��9�:f�]f►[e>�YiID�l�l��
PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS)
SEEDING DATE SEEDING MIXTURE APPLICATION RATE
AUG 25 - OCT (BEST) TALL FESCUE 200 LBS/AC
FEB - APR 15 (POSSIBLE)
SOILAMENDMENTS
FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 4,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 1000
LB/AC 10-10-10 FERTILIZER.
MULCH
APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A
DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.
MAINTENANCE
INSPECT AND REPAIR MULCH FREQUENTLY. REFERTILIZE IN LATE WINTER OF THE FOLLOWING YEAR; USE SOIL TESTS
OR APPLY 150 LB/AC 10-10-10 FERTLIZER. MOW REGULARLY TO A HEIGHT OF 2-4 INCHES.
NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR.
2' ON CENTER
2' ON CENTER
2' ON CENTER
PLANTING INSTRUCTIONS
PLANTING TECHNIQUES
A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD.
B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT.
C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD.
D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION.
E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS.
F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY.
G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT
WALL SHALL BE SCARIFIED PRIOR TO PLANT INSTALLATION.
H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL.
I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE
VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL.
WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL.
J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE
THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT.
CONTAINER STOCK / BARE ROOT
A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD
ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER.
B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS.
C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW.
D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS,
TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH
OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT.
PLANT LOCATIONS
A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION.
B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE.
WATER
WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE.
J
W
� Q
o j
z
GRACE POINTE DRIVE
(50' PUBLIC R/W)
RAGING CREEK DRIVE
(50' PUBLIC R/W)
STORMWATER CONTROL MEASURE 'A' LANDSCAPE PLAN
1" = 30'
I
i!
►Q
GRAPHIC SCALE
0 15 30 60
1 inch = 30 ft.
'J
McADAMS
The John R. McAdams Company, Inc.
3430 Toringdon Way
Suite 110
Charlotte, NC 28277
phone 704. 527. 0800
fax 919. 361. 2269
license number: C-0293, C-187
www.mcadamsco.com
CLIENT
MR. MIKE KISSEL
KOLTER LAND PARTNERS, LLC
701 SOUTH OLIVE AVENUE, SUITE 111
WEST PALM BEACH, FLORIDA 33401
KOLTER
LAND PARTNERS
z
J
W
Q
OU
aw
—
CJ
LU W
-
Q
O
00
N
—
Q
z
WILD
a
z
LU
J
J
VAW
wc�
or
W
Vl
a
J
<_
U
Q
=
w
>
z
O
w
o
z
�
z
J
Li
O
W
z
Z
�
O
A CAR
r THE JOHN
n ' McADAMS z
= 6 :COMPANY, INC..: —o
T
C-0293 r
OF
C All
0.
3 289 =
R• VAN
REVISIONS
NO. DATE
1 06. 15. 2020 REVS PER 1ST REVIEW BY ALL AGENCIES
2 04. 20. 2021 REVS PER 3RD REVIEW BY ALL AGENCIES
PLAN INFORMATION
PROJECT NO
FILENAME
CHECKED BY
DRAWN BY
SCALE
DATE
SHEET
KLP-19000
KLP19000-SWA
MVD
AJ B
1"=30'
01. 17. 2020
STORMWATER CONTROL
MEASURE 'A'
LANDSCAPE PLAN
C960
3