Loading...
HomeMy WebLinkAboutNCG030009_2021 DMR_20220128January 2022 Mr. Zac Lentz NCDEQ Division of Energy, Mineral, and Land Resources Stormwater Program 450 West Hanes Mill Road, Suite 300 Winston-Salem, North Carolina 27105 Subject: Report of Stormwater Sampling — Fourth Quarter 2021 Thomas Built Buses 715 West Fairfield Road High Point, Randolph County, North Carolina NCDEQ Certificate of Coverage No. NCG030009 Ladies/Gentlemen: Attached is a stormwater sampling report for the subject facility. If you have any questions regarding this submittal, please contact the undersigned at 336-382-6849. Sincerely, Jeff Gerlock, L.G. NC Licensed Geologist #1141 Attachments — SW Discharge Monitoring Report Form Cc: Thomas Built Buses, Scott Fister 7356 Belmont Drive, Trinity, NC 27370 - Phone 336-382-6849 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0009 Person Collecting Samples: Jeff Gerlock Facility Name: Thomas Built Buses - Fairfield Laboratory Name: Pace Facility County: Randolph Laboratory Cert. No.: 12 / 37706 Discharge during this period: ✓ll- L�j Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes ] No If so, which Tier (I, II, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR E] Yes No Date Uploaded: Jan 2022 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall SWO-1 Outfall SWO-2 Outfall Outfall Outfall Code N/A Receiving Stream Class WS-IV WS-IV N/A Date Sample Collected MM/DD/YYYY 12-18-2021 12-18-2021 46529 24-Hour Rainfall in inches 0.7 0.7 C0530 TSS in mg/L (100 or 50*) 10.9 19.8 pH in standard units (6.0-9.0 FW, 00400 6.8-8.5 SW) 6.76 6.27 Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) <0.005 <0.005 Lead, total recoverable in mg/L 01051 (0.075 FW, 0.22 SW) <0.005 <0.005 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.0325 0.0344 Chemical Oxygen Demand (COD) in 00340 mg/L(120) 29.6 <25 00552 Non -Polar Oil & Grease in mg/L (15) <5 <5 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, tot e best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting falkinforrhatioAi, including the possibility of fines and imprisonment for knowing violations." Permittee or Delegated Authorized Individual arpad.lukacs@daimler.com Email Address II Z'11tit_ Date 336-442-3550 Phone Number