Loading...
HomeMy WebLinkAboutWQ0006863_Additional Information Response_20220228DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS WILLIAM C. DIEHL, P.E. 1500 Piney Plains Rd., Suite 200 JOHN F. PHILLIPS, P.E. Cary, North Carolina 27518 ALAN R. KEITH, P.E. Telephone (919) 467-9972 – Fax (919) 467-5327 February 28, 2022 Ms. Lauren Raup-Plummer, PE NCDEQ, Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Additional Information Request Permit Renewal Application No. WQ0006863 Genesis Condominiums WWTP High Rate Infiltration System Carteret County Dear Ms. Raup-Plummer: We offer the following responses and information in reply to your letter of November 29, 2021, to Mr. Grady Fulcher: B. Application: 1. It is my understanding that the ORC for this system, Mr. Don O’Mara has contacted the Operator Certification section and the operator designations have been corrected and updated. 2. The previous Site Map was of a poor quality, which made it difficult to determine where the monitoring wells were located in relation to the compliance and review boundaries. To correct this situation, the Genesis HOA retained a registered land surveyor to accurately locate the wells, infiltration areas, and property lines. Section VIII of the application has been revised to reflect information obtained by the survey, and a copy of the revised page is enclosed. The listed latitude and longitudes were also revised slightly, based on the surveyed locations of the wells. MW-1 is located 1.40 feet from the Review Boundary, and is assumed to be on the Review Boundary given the boundary of the infiltration site is not a precise line. MW-2 is located 3.65 feet from the Review Boundary, and is now noted in the revised Section VIII as being inside the Review Boundary. MW-3 is located on the Compliance Boundary, as originally noted in Section VIII. Mr. Lauren Raup-Plummer, PE February 28, 2022 Page 2 of 2 MW-4 is located outside of the Compliance Boundary, as originally noted in Section VIII. C. Site Map: Update site maps, prepared in accordance with 15A NCAC 2T .0704(d) are enclosed. D. Additional Documentation: It is my understanding from Mr. Don O’Mara, the ORC for the facility, that he contacted you about the aeration system and the issue/question has been resolved. Thank you for your patience regarding this response. As Mr. Fulcher explained in a previous email, it has been difficult to find a surveyor that would agree to provide this survey in a timely manner. Please let me know if you require anything else to process this permit renewal. Yours very truly, Diehl & Phillips, P.A. John F. Phillips, P.E. Enclosures Cc: Mr. Grady Fulcher Mr. Don O’Mara FORM: HRIS-R 02-21 Page 2 of 6 SECTION V – OPERATOR IN RESPONSIBLE CHARGE (ORC) INFORMATION 1. ORC: Don O'Mara Grade: 3 Certification No.: 7904 Mailing address: P.O. Box 4602 City: Emerld Isle State: NC Zip: 28594- Phone number: (252) 725-2129 Cell Email: D_Omara@hotmail.com 2. Back-Up ORC: Stanley Buck Grade: 3 Certification No.: 993396 Mailing address: 133 Rattan Street City: Newport State: NC Zip: 28570- Phone number: (252) 503-5307 Cell Email: SECTION VI – OPEN-ATMOSPHERE STRUCTURES 1. List all open-atmosphere treatment and storage structures associated with the renewing permit. Attach additional sheets if necessary. Type Parcel No. Volume (gal) Liner Type Freeboard (ft) Latitude Longitude Select Select . ° - . ° Select Select . ° - . ° Select Select . ° - . ° Select Select . ° - . ° SECTION VII – RELATED PERMITS 1. List all wastewater permits (i.e., sewer, collection system, NPDES, residuals) that have interactions with the renewing permi t. Attach additional sheets if necessary. Permit Type Permit No. Relationship Type Select Select Select Select Select Select Select Select SECTION VIII – MONITORING WELLS 1. List all groundwater monitoring wells associated with the renewing permit. Attach additional sheets if necessary. Well Name Parcel No. Status Gradient Location Latitude Longitude MW-1 635518407873000 Active Upgradient On Review Boundary 34.695047° -76.821644° MW-2 635518407873000 Active Upgradient Inside Review Boundary 34.695008° -76.821869° MW-3 635518405964000 Active Downgradient Outside Compliance Boundary 34.694311° -76.821242° MW-4 635518407873000 Active Downgradient On Compliance Boundary 34.694858° -76.821733° Select Select Select . ° - . ° Select Select Select . ° - . ° Select Select Select . ° - . ° Select Select Select . ° - . ° Select Select Select . ° - . ° Select Select Select . ° - . ° Select Select Select . ° - . ° 50505050 50 50 50 505050501001001001001 0 0 100 100 100 1001001001001001002002002002002002002002 0 0 20 0 200 200 200 200 200 2002002002002002002002002002005005005005005005005005005005005005005005005005005 0 0 5 0 0 5 0 0 50 0 500 500 500 500 500 500 500 500 500 500 500 5005005005005005005005005005005005005005005005005005005005005004004004004004004004004004004004004004004 0 0 4 0 0 40 0 40 0 400 400 400 400 400 400 400 400 400400400400400400400400400400400400400400400400400400INFILTRATION SITES TREATMENT UNITS SALTER PATH RO A D SALTER P A T H R O A D PINE KNOLL CIRCLE EVERGREEN LANE PINE KNOLL BLVD.500 500 500 200 200 200 100 100 100 LEGEND 200 0 100 200 400 GRAPHIC SCALE ( IN FEET ) 15A NCAC 02T .0704(d) SITE MAP 1 OF 2 FOR GENESIS CONDOMINIUMS 50 50 50 SETBACKS PER 15A NCAC 02T .0706 · · · · · · · · · · 400 400 400 CCCCCCCCCCCCCCCCCCC C C C C C C C C RRRRRRRRRR R R R R R R R RRRRRC C C R R R LEGEND 20 0 10 20 40 GRAPHIC SCALE ( IN FEET ) 15A NCAC 02T .0704(d) SITE MAP 2 OF 2 FOR GENESIS CONDOMINIUMS COMPLIANCE AND REVIEW BOUNDARIES FOR INFILTRATION SITES (SYSTEM WAS PERMITTED PRIOR TO DECEMBER 30, 1983).