Loading...
HomeMy WebLinkAboutNC0004987_Fact Sheet_20200608DEQ/DWR FACT SHEET FOR NPDES PERMIT DEVELOPMENT/Major Modification NPDES No. NC0004987 Facility Information Applicant/Facility Name: Duke Energy — Marshall Steam Station Applicant Address: Water Management, Duke Energy, P.O. Box 1006, Charlotte, NC 28201 Facility Address: 8320 E. NC Highway 150, Terrell, NC 28682 Permitted Flow Not Limited Type of Waste: 100.0% Industrial Facility/Permit Status: Major Modification County: Catawba Miscellaneous Receiving Stream: Lake Norman Regional Office: Mooresville Stream Classification: WS-IV & B CA USGS Topo Quad: Lake Norman North 303(d) Listed?: No Permit Writer: Sergei Chernikov, Ph.D. Subbasin: 03-08-32 Date: June 8, 2020 Drainage Area (mi2): NA Addillir Summer 7Q10 (cfs) Release (60 cfs) Winter 7Q10 (cfs): NA 1Q10 (cfs): IWC (%): 23 SUMMARY This permit is being modified to make the following changes: 1). Add the bottom ash purge to the list of the contributing sources of wastewater to the Lined Retention Basin. Per updated 40 CFR 423.13 (k) (2) (i) (A), the discharge of pollutants in bottom ash transport water from a properly installed, operated, and maintained bottom ash system is authorized to maintain system water chemistry where installed equipment at the facility is unable to manage pH, corrosive substances, substances or conditions causing scaling, or fine particulates to below levels which impact system operation or maintenance. 2). To adjust the Technology Based Effluent Limits for Total Arsenic, Total Mercury, Total Selenium, and Nitrate/nitrite as N for Internal Outfall 006 (FGD wastewater) in accordance with updated 40 CFR 423.13(g)(1)(i). Please see the table below for details. Both changes are based on the October 13, 2020 update to the 40 CFR 423 (BAT). Pollutant Existing monthly average - daily maximum limit Modified monthly average - daily maximum limit Arsenic 8.0 µg/L — 11.0 µg/L 8.0 µg/L — 18.0 µg/L Selenium 12.0 µg/L — 23.0 µg/L 29.0 µg/L — 70.0 µg/L Mercury 356.0 µg/L — 788.0 µg/L 34.0 µg/L — 103.0 µg/L Nitrate/Nitrite 4.4 mg/L — 17.0 mg/L 3.0 mg/L — 4.0 mg/L 3). The pH limit for FGD wastewater was eliminated (Internal Outfall 006) to correct an error. NPDES Permit NC 0004987 Page 1 All the remaining terms and conditions of the permit remain unchanged. PROPOSED SCHEDULE Draft Permit to Public Notice: Permit Scheduled to Issue: February 9, 2021 (est.) April 2, 2021 (est.) STATE CONTACT If you have any questions on any of the above information or on the attached permit, please contact Sergei Chernikov at (919) 707-3606 or sergei.chernikov@ncdenr.gov. CHANGES IN THE FINAL MODIFICATION The optimization requirement and the reopener clause were added for the FGD Effluent Page in response to the SELC comments. NPDES Permit NC 0004987 Page 2