HomeMy WebLinkAboutWQ0043331_Application (FTSE)_20220401KENNERLY ENGINEERING & DESIGN, INC. 12133 N. NC HWY 150, Ste. F Winston-Salem, NC 27127 (336) 775-2118 Timothy.kennerly@kennerlyengineering.com DAVIDSON LAND DEVELOPMENT 5930 E. OLD US HWY 64 LEXINGTON, NC 27292 (336) 250-0483 RIDGEMONT SUBDIVISION SECTIONS 3 & 4 WHITNEY ROAD MOCKSVILLE, NC SANITARY SEWER EXTENSION APPLICATION . „N CA, S. =oe.•ocESS/o/�% pT•vGINE. KED PROJECT #21-022 APRIL 2022 KENNERLY ENGINEERING & DESIGN, INC. April 1, 2022 Jenny Graznak Assistant Regional Supervisor NC Division of Water Resources Department of Environmental Quality 450 Hanes Mill Road Winston-Salem, NC 27103 RE: Project Name: Ridgemont Subdivision Section 3 & 4 County: Davie City: Mocksville Address: 604 Whitney Road Submitted by: Kennerly Engineering & Design, Inc. Ms. Graznak, Kennerly Engineering & Design, Inc. (KED) submits the following application for your review, comments and/or approval. Please find attached two (2) copies of the application and calculations for the above referenced project. KED has been retained as the Design Engineer and Engineer of Record for the Ridgemont Subdivision Section 3 & 4 located in Mocksville, NC. The project is a continuation of an existing subdivision that began in the 1970's. Section 3 & 4 are the last sections of the development that have not been constructed. Section 3 & 4 will consist of single-family homes. This project will include approximately 4,062 LF of 8" diameter sanitary sewer line. The proposed sanitary sewer lines will be installed within the right-of-way of the road system except for the outfall connections to the existing sanitary sewer system owned by the Town of Mocksville. The existing sanitary sewer outfalls are located within the 100 YR floodplain of Elisha Creek and an. unnamed tributary of Elisha Creek. The sanitary sewer for this project will be public and will be owned and maintained by the Town of Mocksville. There will be three (3) sanitary Sewer Outfalls for this section of the subdivision. The outfalls will include stream crossings, wetlands and floodplain disturbance. KED has contracted an Environmental Group, NW Geoscience, PC, to permit the stream crossings, wetlands and floodplain disturbances. NW Geoscience has met on site with the Army Corp of Engineers and delineated the areas of the crossings and made he determinations with Corp. NW Geoscience has filled for the NW 58 Permits for the sanitary sewer outfalls and will contact the NC Division of Water Resources to obtain the 401/404 certifications that will also be needed once the Corp permits are obtained. An Erosion Control Permit was issued by NCDEQ on September 20, 2021 for the land disturbance activities for the project. Public Water Supply (PWS) has also issued a permit for Phase 3A of the project and the remaining portion of the subdivision is under review by PWS currently. Should you have any questions, please do not hesitate to contact us at 336.775.2118. Sincerely, ‘0,1--Cri—dor Timothy S. Kennerly, PE Senior Engineer Enclosures: 1 signed original application, 1 copy of the application and 2 sets of calculations. 12133 N. HWY 150, Ste. F Winston-Salem, NC 27127 Phone: 336.775.2118 Fax: 336.764.0797 www.kennerlyengineering.com DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Mocksville (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Kenneth Gamble per 15A NCAC 02T .0106(b) Title: Town manager 4. Applicant's mailing address: 171 South Clement Street City: Mocksville State: NC Zip: 27028- 5. Applicant's contact information: Phone number: (336) 753-6700 Email Address: kgamble@mocksvillenc.gov II. PROJECT INFORMATION: 1. Project name: Ridgemont Subdivision Section 3A 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: W000 3. County where project is located: Davie 4. Approximate Coordinates (Decimal Degrees): Latitude: N35.903397° Longitude:-W80.522482° 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Timothy S. Kennerly License Number: 29317 Firm: Kennerly Engineering & Design, Inc. Mailing address: 12133 N. NC HWY 150, STE F City: Winston-Salem State: NC Zip: 27127- Phone number: (336) 775-2118 Email Address: timothy.kennerlyc 1kennerlvengineering.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Dutcham Creek WWTP Permit Number: NC0021491 Owner Name: Town of Mocksville V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. PermitNumber(s): WQCS00156 2. Downstream (Receiving) Sewer Information: 24 inch Z Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes 0 No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No Z N/A 4. Origin of wastewater: (check all that apply): Z Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Food and drink facilities ❑ Church ❑ Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming PoolClubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ® No > If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow °,b No. of Units Flow 3 Bedroom Residential 360 gal/day 74 26,640 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 26,640 GPD a See 15A NCAC 02T .0114(b), (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facili ies located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 26 640 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VD. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 4,062 PVC > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) > This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the me hod of solids reduction per MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump > Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: > Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 - Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)? 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A > If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A S. Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. > No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ['Yes ❑ No • This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ® Yes ❑ No or 401 Water Quality Certifications? > Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" El Yes ®No Per 15A NCAC 02T.0402 "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version) and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: I, Timothy S. Kennedy , attest that this application for Ridgemont Subdivision Section 3 & 4 (Professional Engineer's name from Application Item m.1.) (Project Name from Application Item II. I) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or`certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Kenneth Gamble , attest that'this application for Ridgemont Subdivision Section 3 & 4 (Signature Authority Name from Application Item I.3.) (Project Name from Application Item II.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B any person who knowingly makes any false statement, representation, or rtification in application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to expljed'�10,QA0 as wel civil penalties up to $25,000 per violation. Signature: Date: 6'3 az_ FORM: FTA 06-21 Page 5 of 5 . Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Davidson Land Development Project Name for which flow is being requested: Ridgemont Subdivision Section 3A More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Dutchman's Creek WWTP b. WWTP Facility Permit #: NC0021491 All flows are in MGD c. WWTP facility's permitted flow 0.98 d. Estimated obligated flow not yet tributary to the WWTP 0.041 e. WWTP facility's actual avg. flow 0.483 f. Total flow for this specific request 0.0266 g. Total actual and obligated flows to the facility 0.550 h. Percent of permitted flow used 55% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name (Sewer): Dutchman's Creek WWTP Downstream Permit Number: NC0021491 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Kenneth Gamble certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Sininng-g Official Signature 2Zic '/1 474' 5- err Title of Signing Official (1' Date Page 2 of 6 FTSE 10-18 Ada • ted from TR-55 Please fill in the appropriate yellow boxes. Project Name: Project Address: Project En • ineer/Developer: Telephone: 1-bedroom 2-bedroom 3-bedroom or lar•er rc1 1-bedroom 2-bedroom 3-bedroom Hotels •er bedroom Lod•in. houses and Tourist Homes •er bedroom Motels and Tourist Cabins •er bedroom Boardin• Homes max. •ermitted occu•anc Cam. • round/mobile rec. vehicle/tent •er site Parked mobile trailer •er site Children's Cam's •er bed Labor cam •s •er bed Da Cam's --no meals •er •erson Ridgemont Subdivision Section 3 & 4 Whitney Road, Mocksville, NC Tim Kennerly/ Kennerly Engineering & Design, Inc. 336.775.2118 74 120 240 360 110 170 225 75 60 60 50 100 200 50 40 15 0 0 26640 0 0 0 0 0 0 0 0 0 0 0 0 Version 8/15/16 0 WH ££:£S:OL 6ZOZ/SL z O O c 0 G N = 21 y O— O v 0 O 0 O O .a c o Its — N co In 0 ri3 cn O N 3 N 01 3.c — 0) 0 NG m ,40 -_ 0 corm a in y Y t 33 o 3 m c 5 Ridgemont Subdivision Section 3 & 4 C CO v coc