Loading...
HomeMy WebLinkAboutNC0085359_Authorization to Construct_20200226NPDES DOCUMENT SCANNIN`t COVER SHEET NPDES Permit: NC0085839 Twelve Mile Creek WWTP Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC)) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: February 26, 2020 Thine document is printed ari reuae paper - ignore any content cm. the resrersce slide :on ..'ounty Public Works Department Miie ,'reek WWTP .o Construct No. 085359A07 .tied Match 31, 2016 Engineer's Certification RECEIVED FEB 2 6 2020 NCDEQ/DWR/NPDES '1 �- ii-n t Cr'L I, �'a "`' "';`'�•, :v '�' , as a duly registered Professional Engineer in Mate of North Carolina, having been authorized to observe (periodically/weekly/full time) :he construction of the modifications and improvements to the Twelve Mile Creek Wastewater catment Plant, located in Union County, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: Installation of two (2) new 12 MGD peak flow mechanical rake screens with wash and ],Tess compactor systems replacing the mechanical screen system, piping, and controls; installation of new 48 in gravity main between screening basin and effluent pump station; installation of new 30 in force main from influent pump station to treatment facility; demolition of grit removal system and FAO distribution box; installation of new grit removal system consisting of two (2) 20 MGD peak flow vortex grit collectors with grit rumps, grit wash systems, grit conveyors, sump pumps, odor control system, piping, and ::; nirols; installation of new aeration basins distribution structure with two (2) vertical ,= :ers. piping, and controls; installation of new fine bubble diffuser array in aeration tanks 1 : i acing the mechanical aeration system, piping, and control; installation of three (3) new ...ration System blowers, two (2) 6,067 CFM and one (1) 9,050 CFM, piping, and controls; •;..inc,iition of UV disinfection system and cascade aerator; installation of new UV •cction system consisting of dual channels with each channel containing 3 banks (2 i.y, 1 redundant) and with each channel rated disinfection capacity at peak flow 22.5 •G), piping, and controls; installation of one (1) new 200 GPM at 200 ft TDH EFW •'c;mp, piping, and controls; installation of one (1) inline pressure UV disinfection system aged for 400 GPM, piping, and controls; installation of new 11,320 gallon post cascade aeraion basin, piping, and controls; installation of new jet -mix systems using existing air ,uppiy. and circulation flow replacing coarse bubble mix system in digesters 3 & 4, piping, LiAd controls; installation of four (4) new 9,000 GPM at 24 fl TDH jet circulation pumps, ; Pirig, and controls; demolition of gravity belt thickener system; installation of two (2) new gravity belt thickener systems each system consisting of a grinder, polymer injection/mixing, 633.3 dry lb/hr gravity belt thickener with VFD, 150 GPM at 138.6 ft DJ-1 t:,iLir.ened sludge pump with VFD, wash water booster pump, piping, and controls; (1 of two (2) new sludge dewatering belt press systems each consisting of a 200 GPM at 138.6 fi TDII belt filter press .feed pump with VFD, polymer 'mixing, 429.2 dry lb/hr dewatering belt filter press with VFD, wash water booster piping, and controls; filter belt press solids load out conveyor; installation of tbic ken'�r polymer storage and feed system in solidshandling building 'storage containment area tons?sting ; �F :1) closed top 2,550 .gallon storage tank, one (1) 10 GPM at 69.3 ft TDI ! nixing pun;t;. , \vo (2) 3 GPH GPM at 100 psig TDH feed pumps, piping, and Clr.Ii?10 S: i nstallation ; dewatering polymer storage and feed system in solids handling build..tg, Stoiage containment area consisting of one (1) closed. top 2,550 gallon storage tank, ,r : ()) .! 0 GPM at 69.3 fi TDH mixing pump, two (2) 10 GPH at 100 psig TDH feed prl,r�� and controls; installation of one (1) 1,000 KW, 480 VAC, 3 PH standby Engineer's Certification A to C No. 085359A07 Page 2 of 2 diesel generator (new aeration blowers); in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. This authorization results in an approved increase in design and permitted capacity to 7.5 MGD provided A to C No. 085359A06 has also been completed. I certify that the construction of the above referenced project was observed to be built within substantial compliance, intent and in conformity with all applicable regulations and statutes and the project plans, specifications, and other supporting documentation comprising the Authorization to Construct Permit Application package. Signature/f\ Date 2/2f/7..4.7i. Q Mail this Certification to:. Registration No. 6 7-3 1 3 Attn: Ron Berry Complex Permitting Unit DEQ/DWRIWater Quality Programs 1617 Mail Service Center Raleigh, NC 27699-1617 Water Resources ENVIRONMENTAL QUALITY j° ors pi/ klcou c) March 31, 2016 Mr. Scott Huneycutt, P.E. Engineering Division Director Union County Public Works Department 500 North Main Street, Suite 500 Monroe, North Carolina 28112-4730 Dear Mr. Huneycutt: PAT MCCRORY Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN SUBJECT: Authorization to Construct A to C No. 085359A07 Union County Public Works Department Twelve Mile Creek WWTP Director A letter of request for an Authorization to Construct was received February 11, 2016, by the Division of Water Resources (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 6.0 MGD Twelve Mile Creek WWTP, with discharge of treated wastewater into the Twelve Mile Creek in the Catawba River Basin. This authorization results in an increase in design and permitted capacity to 7.5 MGD provided A to C No. 085359A06 was also completed, and is awarded for the construction of the following specific modifications: Installation of two (2) new 12 MGD peak flow mechanical rake screens with wash and press compactor systems replacing the mechanical screen system, piping, and controls; installation of new 48 in gravity main between screening basin and effluent pump station; installation of new 30 in force main from influent pump station to treatment facility; demolition of grit removal system and FAO distribution box; installation of new grit removal system consisting of two (2) 20 MGD peak flow vortex grit collectors with grit pumps, grit wash systems, grit conveyors, sump pumps, odor control system, piping, and controls; installation of new aeration basins distribution structure with two (2) vertical mixers, piping, and controls; installation of new fine bubble diffuser array in aeration tanks replacing the mechanical aeration system, piping, and control; installation of three (3) new aeration system blowers, two (2) 6,067 CFM and one (1) 9,050 CFM, piping, and controls; demolition of UV disinfection system and cascade aerator; installation of new UV disinfection system consisting of dual channels with each channel containing 3 banks (2 duty, 1 redundant) and with each channel rated disinfection capacity at peak flow 22.5 MGD, piping, and controls; installation of one (1) new 200 GPM at 200 ft TDH EFW pump, piping, and controls; installation of one (1) inline pressure UV disinfection system rated for 400 GPM, piping, and controls; installation of new 11,320 gallon post cascade aeration State of North Carolina I Environmental Quality I Water Resources 1617 Mail service Center I Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604, Archdale Building 9th Floor Phone: 919 807 6300 / Fax: 919 807 9489 Mr. Scott Huneycutt, P.E., Engineer Division Director March 31, 2016 Page 2 of 4 basin, piping, and controls; installation of new jet -mix systems using existing air supply and circulation flow replacing coarse bubble mix system in digesters 3 & 4, piping, and controls; installation of four (4) new 9,000 GPM at 24 ft TDH jet circulation pumps, piping, and controls; demolition of gravity belt thickener system; installation of two (2) new gravity belt thickener systems each system consisting of a grinder, polymer injection/mixing, 633.3 dry lb/hr gravity belt thickener with VFD, 150 GPM at 138.6 ft TDH thickened sludge pump with VFD, wash water booster pump, piping, and controls; installation of two (2) new sludge dewatering belt press systems each consisting of a grinder, 200 GPM at 138.6 ft TDH belt filter press feed pump with VFD, polymer injection/mixing, 429.2 dry lb/hr dewatering belt filter press with VFD, wash water booster pump, piping, and controls; filter belt press solids load out conveyor; installation of thickener polymer storage and feed system in solids handling building storage containment area consisting of one (1) closed top 2,550 gallon storage tank, one (1) 10 GPM at 69.3 ft TDH mixing pump, two (2) 3 GPH at 100 psig TDH feed pumps, piping, and controls; installation of dewatering polymer storage and feed system in solids handling building storage containment area consisting of one (1) closed top 2,550 gallon storage tank, one (1) 10 GPM at 69.3 ft TDH mixing pump, two (2) 10 GPH at 100 psig TDH feed pumps, piping, and controls; installation of one (1) 1,000 KW, 480 VAC, 3 PH standby diesel generator (new aeration blowers); in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0085359 issued effective January 1, 2015, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0085359. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Mooresville Regional Office, telephone number (704) 663 - 1699, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the t. Mr: Scott Huneycutt, P.E., Engineer Division Director March 31, 2016 Page 3 of 4 approved plans and specifications. Mail the Certification to: Division of Water Resources, WQ Permitting Section — NPDES, 1617 Mail Service Center, Raleigh, NC 27699-1617. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV . facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. Mr. Scott Huneycutt, P.E., Engineer Division Director March 31, 2016 Page 4 of 4 If you have any questions or need additional information, please contact Ron Berry at telephone number (919) 807-6396. Sincere ai#40,6t-- S. Jay ZMimerman Director, Division of Water Resources cc: Michael Parker, P.E. Hazen and Sawyer 4944 Parkway Plaza Blvd Suite 375 Charlotte, NC 28217 DWR/Mooresville Regional Office, Water Quality Programs Central Files NPDES File Without Engineer's Certificate attached: Union County Health Department