HomeMy WebLinkAboutNC0048861_Authorization to Construct_20150827NPDES DOCUHENT !CANNING: COVER SHEET NPDES Permit: NC0048861 Creswell WWTP Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: August 27, 2015 This document is printed on reuse paper - ignore any content on the reirerse aside Town of Creswell Wastewater Treatment Plant Improvements A To C No. 048861A02 Issued February 29, 2012 FINAL Engineer's Certification GAtztvt, � , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to obsery o cally eekly/full time) the construction of the modifications and improvements to the Town f Creswell WWTP, located on NCSR 1155 in Washington County for the Town of Creswell, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: RECr" 'ED AUG 2 7 2015 Replacement of the existing lagoon WWTP with a new 0.200 MGD WWTP system consisting of: an influent flow splitter box structure; influent pump station with two (2) 350 gpm pumps; influent flow meter, two (2) 350 gpm mechanical fme (2 mm) bar screens; one (1) screenings compactor; EITHER (Base Bid) a 0.200 MGD membrane bioreactor (MBR) system, consisting of: two (2) 22,400 gallon anoxic tanks with two 2.3 Hp submersibile mixers; two (2) 42,300 gallon anoxic basins each with a 2.3 hp submersible mixer; two (2) 42,300 gallon aerobic basins with fme bubble diffusers, two (2) 278 gpm NRCY recycle humps and three (3) 245 scfm aeration process blowers; two (2) 34,800 gallon membrane bioreactor basins containing a total of 8 membrane units rated and three (3) 630 scfm MBR process (scour) blowers; two (2) 195 gpm permeate pumps with two (2) flow meters; two (2) 208 gpm RAS pumps with two (2) flow meters; one (1) 150 gpm WAS pump with flow meter, a sodium hydroxide storage and feed system; an alum storage and feed system; OR (Alternate No. 1 train consisting of a 17, 104,000 gallon aerobic zon • wi pump, and a 352 ft2 secondar RAS/WAS pump station wi two (2) 72 ft2 tertiary sand ` her ce 0.200 MGD 0 gallo ual train concrete pa oxic zone an. ? 2.3 fine bubble diffuser huffier; three (3) 492 s 1105 gpm RAS pu with 16,200 g ge WWTP with each submersible mixer, a 80 gpm NRCY recycle aeration blowers; da 150gpmWASpump; ell with dual 1,080 gpm backwash pumps, d 1216 scf . it scour blowers, and a 19,440 gallon mudwell and dual 120 gpm pumps; alkalinity storage and feed system; OR (Alternate No. 2) a 0.200 • : GD d train steel ► ackage consisting of a 17,950 gallon an is one with a 7. 104,000 gallon aerobic zone, a 28 ► • m NRCY recycl clarifier; RAS/WAS pump station ''th dual 105 gpm WAS pump; three (3) 492 scfm a atl ' n blowers; four cells with 15,625 gallon clearw and : ur (4) 521 gp scfm air scour blowers, and a 6,400 gal on mudwel alkalinity storage and feed system; SP,/ with each train mersible mixer, an p, a 352 ft2 secondary pumps and a 150 gpm ) .7 ft2 tertiary sand filter bac . ash pumps, dual 105 ith dual 138 gpm pumps; I& c,dr Town of Creswell Wastewater Treatment Plant Improvements A To C No. 048861A02 Issued February 29, 2012 R EA\I o,I 1natkag iN Engineer's Certification I, b 65, GAr-r,N' , as a duly registered Professional Engineer in the State of North Carolina, having een authorized to observe ( • ' all eekly/full time) the construction of the modifications and improvements to the Town o Creswell WWTP, located on NCSR 1155 in Washington County for the Town of Creswell, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: mciceas bJWT' 't'C.T enah ooA Replacement of the existing lagoon WWTP with a new 0.200 MGD WWTP system consisting of: an influent flow splitter box structure; influent pump station with two (2) 350 gpm pumps; influent flow meter; two (2) 350 gpm mechanical fme (2 mm) bar screens; one (1) screenings compactor; EITHER (Base Bid) a 0.200 MGD membrane bioreactor (MBR) system, consisting of: two (2) 22,400 gallon anoxic tanks with two 2.3 Hp submersibile mixers; two (2) 42,300 gallon anoxic basins each with a 2.3 hp submersible mixer; two (2) 42,300 7 gallon aerobic basins with fme bubble diffusers, two (2) 278 gpm NRCY recycle pumps and three (3) 245 scfm aeration process blowers; two (2) 34,800 gallon membrane bioreactor basins containing a total of 8 membrane units rated and three (3) 630 scfm MBR process (scour) blowers; two (2) 195 gpm permeate pumps with two (2) flow meters; two (2) 208 gpm RAS pumps with two (2) flow meters; one (1) 150 gpm WAS pump with flow meter; a sodium hydroxide storage and feed system; an alum storage and feed system; OR (Alte , ate No. 1) a 0. 00 MG • ual train con r ete packag= WWTP train cons' g of a 17,9.0 gallon an + : is zone = ► d a 2.3 Hp sub ersibl 104,000 gallo aerobi zone with fine ubble dY sers, a 280 gpm pump, and a 3 = ft2 condary clarifier; ee ) 492 scfm aeration RAS/WAS pump . . tion with dual 105 gp pumps and a 15gp two (2) 72 ft2 to sand filter cells wi - 1. 200 gallon clearwe with gpm backwas ' . umps dual 216 scfm . sco blowers, and a 1► ,440 gal and dual 120 : • m pum ; : • linity storage and ed system; OR (Alternate consisting of a 1 104,000 gallon a clarifier; RAS/W WAS pump; three (3 cells with 15,625 llo scfm air scour b wers, alkalinity storage and fee o. 2) a 0.2 950 ga bic MGD dual ain steel anoxic zone ith a 7. ne, a 280 gpm Y r p station with dual 492 scfm aeration blow clearwell and four d a 16,400 gallo system; mud w• each mixer, a Y recycle owers; WAS pump; ual 1,080 n mudwell ckage ' with ea Hp submersible ycle pump, a 352 gpm RAS pumps and ; four (4) 34.7 ft2 tert 1 gpm backwash p 11 with dual 13 : gpm train an condary 150 gpm sand filter ual 105 pu . s; Town of Creswell Wastewater Treatment Plant Improvements A To C No. O48861AO2 Issued February 29, 2012 Also with: two (2) bank UV disinfection system, each rated for 0.50 MGD peak flow; cascade aeration; effluent pump station consisting of two (2) 350 gpm pumps with effluent flow meter; two (2) 65,000 gallon (each) aerobic digesters with coarse bubble diffusers and two (2) 285 scfm blowers; one (1) 500 gpm sludge transfer pump; a sludge loading station; a 450 kW emergency generator; administration and control building; and associated yard piping, electrical work and control systems, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. We understand that the new limits associated with the modifications to expand to 0.200 MGD now apply. Signature Date .�i/e27//� Registration No. &aB 9/O Mail this Certification to: Attn: Ken Pohlig, F.E. Infrastructure Finance Section DENR/DWQ 1633 Mail Service Center Raleigh, NC 27699-1633 • 46 iESSZO, q SEAL If 028#16...p 411004‘ • ern NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P.E. Dee Freeman Governor Director Secretary February 29, 2012 The Honorable W. J. White, Mayor Town of Creswell Post Office Box 68 Creswell, North Carolina 27928 SUBJECT: Authorization to Construct A to C No. 048861A02 Town of Creswell Creswell WWTP Wastewater Treatment Plant Improvements Washington County Dear Mayor White: A letter of request for an Authorization to Construct was received September 23, 2011, by the Division of Water Quality (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 0.064 MGD Town of Creswell Wastewater Treatment Plant, with discharge of treated wastewater into the Scuppernong River in the Pasquotank River Basin. This authorization results in an increase in design and permitted capacity to 0.200 MGD, and is awarded for the construction of the following specific modifications: Replacement of the existing lagoon WWTP with a new 0.200 MGD WWTP system consisting of: an influent flow splitter box structure; influent pump station with two (2) 350 gpm pumps; influent flow meter; two (2) 350 gpm mechanical fine (2 mm) bar screens; one (1) screenings compactor; EITHER (Base Bid) a 0.200 MGD membrane bioreactor (MBR) system, consisting of: two (2) 22,400 gallon anoxic tanks with two 2.3 Hp submersibile mixers; two (2) 42,300 gallon anoxic basins each with a 2.3 hp submersible mixer; two (2) 42,300 gallon aerobic basins with fine bubble diffusers, two (2) 278 gpm NRCY recycle pumps and three (3) 245 scfm aeration process blowers; two (2) 34,800 gallon membrane bioreactor basins containing a total of 8 membrane units rated and three (3) 630 scfm MBR process (scour) blowers; two (2) 195 gpm permeate pumps with two 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919.807.63001 FAX: 919-807-6492 Internet: www.ncwaterauality.orq An Equal Opportunity \ Affirmative Action Employer North Carolina Xaturaiij 'r The Honorable W. J. White, Mayor February 29, 2012 Page 2 (2) flow meters; two (2) 208 gpm RAS pumps with two (2) flow meters; one (1) 150 gpm WAS pump with flow meter; a sodium hydroxide storage and feed system; an alum storage and feed system; OR (Alternate No. 1) a 0.200 MGD dual train concrete package WWTP with each train consisting of a 17,950 gallon anoxic zone and a 2.3 Hp submersible mixer, a 104,000 gallon aerobic zone with fine bubble diffusers, a 280 gpm NRCY recycle pump, and a 352 ft2 secondary clarifier; three (3) 492 scfm aeration blowers; RAS/WAS pump station with dual 105 gpm RAS pumps and a 150 gpm WAS pump; two (2) 72 ft2 tertiary sand filter cells with 16,200 gallon clearwell with dual 1,080 gpm backwash pumps, dual 216 scfm air scour blowers, and a 19,440 gallon mudwell and dual 120 gpm pumps; alkalinity storage and feed system; OR (Alternate No. 2) a 0.200 MGD dual train steel package WWTP with each train consisting of a 17,950 gallon anoxic zone with a 7.5 Hp submersible mixer, an 104,000 gallon aerobic zone, a 280 gpm NRCY recycle pump, a 352 ft2 secondary clarifier; RAS/WAS pump station with dual 105 gpm RAS pumps and a 150 gpm WAS pump; three (3) 492 scfm aeration blowers; four (4) 34.7 ft2 tertiary sand filter cells with 15,625 gallon clearwell and four (4) 521 gpm backwash pumps, dual 105 scfm air scour blowers, and a 16,400 gallon mudwell with dual 138 gpm pumps; alkalinity storage and feed system; Also with: two (2) bank UV disinfection system, each rated for 0.50 MGD peak flow; cascade aeration; effluent pump station consisting of two (2) 350 gpm pumps with effluent flow meter; two (2) 65,000 gallon (each) aerobic digesters with coarse bubble diffusers and two (2) 285 scfm blowers; one (1) 500 gpm sludge transfer pump; a sludge loading station; a 450 kW emergency generator; administration and control building; and associated yard piping, electrical work and control systems, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0048861 issued July 9, 2009, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0048861. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may The Honorable W. J. White, Mayor February 29, 2012 Page 3 be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Washington Regional Office, telephone number (252) 946-6481, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Infrastructure Finance Section, DWQ/DENR, 1633 Mail Service Center, Raleigh, NC 27699-1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. The Honorable W. J. White, Mayor February 29, 2012 Page 4 Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Seth Robertson, P.E. at telephone number (919) 707-9175. Sincerely, ofo) Charles Wakild, P.E. kp:sr cc: Charles W. Davis, P.E. - The Wooten Company, 120 North Boylan Avenue, Raleigh, NC 27603 Washington County Health Department DWQ Washington Regional Office, Surface Water Protection DWQ, Technical Assistance and Certification Unit DWQ, Point Source Branch, NPDES Program Ken Pohlig, P.E. ATC File