Loading...
HomeMy WebLinkAboutNCC221060_Site Plan or Location Map_20220404BENCHMARK NCGS 7214" ELEVATION: 20.18' NAVD 1988 SITE PLAN KEYNOTES S1 INSTALL 24" CURB & GUTTER AS SHOWN (SEE DETAIL ON SHEET C14). S11 INSTALL 24' WIDE MANUAL DOUBLE LEAF GATE AS SHOWN. S2 INSTALL 6' CHAIN LINK SECURITY FENCE ALONG PERIMETER OF SITE (SEE DETAIL ON SHEET C14). S12 INSTALL HEAVY DUTY ASPHALT IN STORAGE YARD AS SHOWN (SEE DETAIL ON SHEET C14). S3 INSTALL HEAVY DUTY ASPHALT IN DRIVE AISLES AS SHOWN (SEE DETAIL ON SHEET C14). S13 INSTALL 24' WIDE MOTORIZED SWING GATE AS SHOWN. PROPOSED LOCATION OF ABOVE GROUND LIQUID PROPANE TANK WITH 6" PIPE BOLLARDS AT 4' O.C. SLAB TO BE 6" OF S4 INSTALL LIGHT DUTY ASPHALT IN VEHICULAR PARKING SPACES (SEE DETAIL ON SHEET C14). S14 4,000 PSI CONCRETE REINFORCED WITH #4 REBAR AT 12" O.C. EACH WAY OR WWM WITH 6" ABC COMPACTED TO 98% S. P. INSTALL 8" HEAVY DUTY REINFORCED CONCRETE PAVEMENT AS SHOWN SEE DETAIL ON SHEET C14. (OWNER MAY S5 INSTALL 6" ABC STONE IN GRAVEL STORAGE YARD AS SHOWN. S15 SUBSTITUTE ALTERNATE HEAVY DUTY PAVEMENT SECTION AND/OR MATERIAL, WITH THE APPROVAL OF GEOTECHNICAL ENGINEER, BASED ON SITE SPECIFIC SOIL CONDITIONS) INSTALL 10' WIDE CONCRETE APRON ADJACENT TO BUILDING @ 1/8" PER FOOT AWAY FROM BUILDING. EXTERIOR PAD S6 TO MATCH INTERIOR PAD. (SEE STRUCTURAL PLANS FOR SLAB AND REINFORCEMENT DETAILS). INSTALL EXPANSION S16 INSTALL 4' CHAIN LINK FENCE ALONG PERIMETER OF SCM WITH 12' WIDE DOUBLE LEAF GATE FOR ACCESS & JOINT BETWEEN 10' TRANSITION SLAB AND HEAVY DUTY CONCRETE PAVEMENT. MAINTENANCE. S7 INSTALL 6' WIDE CONCRETE SIDEWALKS ADJACENT TO BUILDING AND PARKING. S17 INSTALL 20' MANUAL DOUBLE GATE FOR SEWER ACCESS AND MAINTENANCE. S8 INSTALL CONCRETE WHEEL STOP 30" FROM SIDEWALK/CURB TO TIRE SIDE OF WHEEL STOP S18 CONCRETE CURB TAPER (TYP) PROPOSED LOCATION OF FUEL ISLAND REINFORCED CONCRETE SLAB WITH 6" CONCRETE FILLED PIPE BOLLARDS @ 4' O.C. SLAB SHALL BE 6" OF 4,000 PSI REINFORCED TURNDOWN CONCRETE SLAB WITH #4 REBAR 12" O.C. EACH WAY WITH INSTALL ADA RAMPS WITH DETECTABLE DOMES. CHECK WITH LOCAL INSPECTOR ON TYPE AND COLOR OF DOMES AND S9 6" ABC STONE COMPACTED TO 98% S.P. (WELDED WIRE MESH MAY BE USED FOR REINFORCEMENT. SEE STRUCTURAL S19 FOR GUIDANCE ON RAMP COLOR/TINTING. ENGINEER FOR WWM SPECIFICATIONS. S10 INSTALL PERSONNEL GATE TO REAR OF SITE AS SHOWN. 11E - - — I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I N/F JAYBIRD PROPERTIES, LLC DB. 1767 PG. 561 BM. 2108 PG. 439 PIN 8-206-4A-OOC I EX. SAN. SEWER MANHOLE RIM: 20.86' INV. OUT (8") = 13.88' I S16 ml XI � I GI NI 4�!� F- 0I U X �I L 8" SAN. SEWER LINE S 28°37'50" E r 351.50' (MH-MH) x 5 APPROX.GAS LINE LOCATION EX. SAN. SEWER MANHOLE RIM: 20.86' INV. IN (8") = 12.51' INV. OUT (8") = 12.47' INV. IN (4")(N) = 17.60' INV. OUT (4")(E) = 14.30' 0.00' S 61 °15'36" W N/F HERBERT S. POTTER REVOCABLE TRUST DB. 3504 PG. 1810 BM. 2108 PG. 439 PIN 8-206-8003 PROPERTY LINE TABLE LINE BEARING DISTANCE L1 N 28°44'24" W 50.00' L2 N 28°44'24" W 50.00' SCALE: 1" = 40' 40' 0 40' I SCALE OF MAP MAY VARY DUE TO METHODS OF REPRODUCTION. VICINITY MAP SOUTH BOUND LANES ♦� SCALE: 1 "=500' US HIGHWAY 17 - 0 150' PUBLIC R/W CD NORTH BOUND LANES N/F MARVIN WHEELER & CHRISTY M WHEELER DB. 2428 PG. 40 BM. 2108 PG. 439 PIN 8-206-4-026 EIP N: 491622.93 E: 2554694.99 N 61'15'36" E 781.82' k 50 N/F HEZEKIAH HARPER & TROMONA HARPER e DB. 2973 PG. 27 / o BM. 2108 PG. 439 o PIN 8-206-4-050 CIO k � lk �. 51 N/F / co CRYSTAL HORTON & >c PATRICK HORTON DB. 3071 PG. 2 / Q k BM. 2108 PG. 439 PIN 8-206-4-051 N/F NORMAN S. COLEMAN DB. 2532 PG. 251 BM. 2108 PG. 439 PIN 8-206-4-027 N/F CHARLES LAMONT RAYNOR & SHAWNTA F RAYNOR DB. 3437 PG. 190 / BM. 2108 PG. 439 / PIN 8-206-4-052 NPS WOOD FENCE POST 28 IN CONCRETE 0.2' EAST OF CORNER N/F \MEGAN DEWAR & KEVEN DEWAR DB. 3271 PG. 250 BM. 2108 PG. 439 PIN 8-206-4-028 � S2 NOTE: ALL WORK MUST COMPLY WITH APPLICABLE NORTH �O N/F CAROLINA BUILDING CODES, HANDICAPPED ACCESSIBILITY CODE 20 REAR YARD } ALLEN L. MILLET & 409.06 S 61o1536W CAROLINE H. MILLET VOL. 1C., AND WITH THE TOWN OF RIVER BEND, CRAVEN COUNTY \ AND NCDOT STANDARDS, DETAILS AND SPECIFICATIONS. DB. 3506 PG. 1632 44 / 45 46 O BM. 2108 PG. 439 O PIN 8-206-4-025 N/F / N/F 24 NOTE: CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER IMMEDIATELY N/F • NICOLE P. DAVIS 0 4 IF ANY CONFLICTS, INCONSISTENCIES OR AMBIGUITIES EXIST BETWEEN GROVER G. MILLS GROVER MILLS & DANIEL C. DAVIS / N/F \ ARCHITECTURAL, P.M.E., STRUCTURAL & CIVIL DRAWINGS & 1 DB. 3247 PG. 46 & TAMMY P. MILLS & TAMMY P. MILLS SPECIFICATIONS. IF HIDDEN SITE CONDITIONS ARE DISCOVERED / DB. 3568 PG. 686 DB. 3568 PG. 686 CHRISTOPHER A LASALLE BM. 2108 PG. 439 DURING CONSTRUCTION/DEMOLITION, CONTRACTOR SHALL OBTAIN BM. 2108 PG. 439 BM. 2108 PG. 439 / & PAMELA ANN LASALLE PIN 8-206-4A-044 / PIN 8-206-4A-045 / PIN 8-206-4A-046 DB. 2631 PG. 240 \ WRITTEN RESOLUTION PRIOR TO PROCEEDING WITH CONSTRUCTION. Know what's below. BM. 2108 PG. 439 OTHERWISE, CONTRACTOR PROCEEDS AT THEIR OWN RISK. Call before you dig. PIN 8-206-4-024 o ' ssio�°'�y': SEAL = 032614 - 03/03/22 E,:tAG I NEE'' , RpoRy ���'�c °�O =�S SEAL 8n- - C-3075 - o °C A Ra FINAL DRAWING RELEASED FOR CONSTRUCTION THIS ORIGINAL SHEET IS 24"X36", OTHER DIMENSIONS INDICATE IT HAS BEEN ALTERED. ALL INFORMATION REPRESENTED ON THIS SHEET IS THE PROPERTY OF RED LINE ENGINEERING, P.C. UNDER PENALTY OF LAW, THIS INFORMATION SHALL NOT BE DUPLICATED IN PART OR WHOLE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM RED LINE ENGINEERING, P.C. 2022 Ln N ti LO O r M N U z J (U 0 a a Z = WLU W O c"'o z�a� ZU)ZP- W =a°rn - W w � - W D LU z o a I=i d N LO 00 N a z (n J r` O Q U 2 � LD = O z z w 00 W z Lid O Lid ^9r- z L.L 0 W LLJ m 0. 0 w w >(1) �p J 0- wO m 0- D REVISIONS: DATE: ISSUED FOR: DATE: REVIEW/PERMIT 2/7/22 LLL� PROJECT NO.: 21-014 DRAWN BY: TAIL REVIEWED BY: GJM SHEET NUMBER: C3 OF 19 SHEETS