Loading...
HomeMy WebLinkAboutWI0100428_Geothermal Well Construction Record (GW1)_20160322CANS UCT CN R1 This form can he used for single or multiple wells 1, Well Contractor Information: Robert Larry Wells Well contractor Tune 2603-A Division of Water Rescur M AY 1 6 2011 Water Ouality Rpoonal Or NC Well Contractor Certification Number AWD Services Inc Company Name �1 f 2. Well ConstrueffonPermit#: WID 1 00428 List all applicable well construction permits (i.e. County, Stare, Ynriance. ete) 3. Well Use (check well use): Water Supply Well: 4Agricultural k6eathermal (HeatineCooling Supply) ❑ Industrial/Commercial i]lrrigatiorl _ Non -Water Supply Wen: ❑Monitoring Injection Weft: ❑Aquifer Recharge ❑Aquifer Storage and Recovery El Aquifer Test []Experimental Technology RUeothermal (Closed Loop) ❑MunicipallPublic El Residential Water Supply (single) ❑Residential Water Supply (shared) ❑Groundwater Rem ediation ❑Salinity Harrier ❑Stormwater Drainage ❑Subsidence Control ❑Tracer ucfeotttermal HeEgU/Cooling Return) ❑Other (explain under #21 Remarks) 4. Date'Well(s) Completed: 3/22/16 well Ill# 3ti. Well Location. - Michael Schneider FacilitylOwner Name Facility 104 (ifapglicable) 6 Mayflower Dr. Asheville, NC 28804 Physical Address, City, and Zip Buncombe 9649854351000 County Parcel idcatifioation No. (PIN) 5b. Latitude and Longitude in degreeslminutes/seconds or decimal degrees; (ifwell Held, one Iat4ons is suif'icient) 35 36' 320' N 82 32' 17" W 6. Is (are) the well(s): XPermanent or []Temporary 7. Is this a repair to an existing well: ❑Yes or XNo . If this is a repair, fill our known well construclion information and explain the nature of the repair under,121 remarks section or on the bock of this• forum. 8. Number of wells constructed: 2 For multiple injection or non -water supply x•ells ONLY with the same conslrucdon, you can submit one form. 9. Total well depth below land surface: 2 @ 260' (ft.) For multiple wells list all depths ifdffferenr (example- 3@200' and 2@100') 10. Static water level below top of casing: NIA (ft.) If wafer level is above caslgg, use " t " 6 25tt will, 15A NCAC 02C -0100 ar 15A NCAC 02C.020D Well Canrtructian Standards and that n copy of lids record hat been provided to the mvil otiryrer. 23. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages ifnecessary. SUBMITTAL INSTUCTIONS 24a. For All Well : Submit this form within 30 days of completion of well construction to the fallowing - Division of Water Quality, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699.1617 11. Borehole diameter: (in,) 24K For In ecti n Fells: In addition to sending the form to the address in 24a above, also submit a copy of this form within 30 days of completion of well 12. Well coustrucilma method: rota construction to the following: (i.e. auger, rotary, cable, direct push, etc.) Division of Water Quality, Underground Injection Control Program, FOR WATER SUPPLY WELLS ONLY; 1636 Mail Service Center, Raleigh, NC 27699-1636 13a. 'Yield (gpm) Method of test: 24c. Fo L&L&R& & I o We n addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of 13h Disinfection type: Amount: completion of welt construction to the county health department of the county where constructed. Faun Gw-1 North Carolina Depa0ment of Environment and Natural Resources - Division of Water uali Q ry Revised Jan .2p13