HomeMy WebLinkAboutWQ0002857_More Information (Requested)_20220112ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director DONNA MOORE — PRESIDENT CHAPEL ROAD PROPERTIES, LLC 430 NC HIGHWAY 49 SOUTH ASHEBORO, NORTH CAROLINA 27205 Dear Ms. Moore: NORTH CAROLINA Environmental Quality January 12, 2022 Subject Application No. WQ0002857 Additional Information Request Piedmont Custom Meats WWTF Wastewater Irrigation System Caswell County Division of Water Resources' Central and Regional staff has reviewed the application package received November 5, 2021. However, additional information is required before the review may be completed. Please address the items on the attached pages no later than the close of business on February 11, 2022. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items in Sections A through D, or failure to provide the additional information on or before the above requested date may result in your application being returned as incomplete. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated (where needed), with one electronic copy submitted to my attention at the email address below. If you have any questions regarding this request, please do not hesitate to contact me at (919) 707- 3658 or vivien.zhongkncdenr.gov. Thank you for your cooperation. Sincerely, DocuSigned by: E42E88CDBD404A7... Vivien Zhong, Environmental Engineer Division of Water Resources cc: Winston-Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy) Larry Moore — Chapel Road Properties, LLC (Electronic Copy) Permit Application File WQ0002857 D ��� North Carolina Department of Environmental Quality j Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINI� oewdeM er imen,e„ai a�ainv 919,707,9000 Ms. Donna Moore January 12, 2022 Page 2 of 2 A. Groundwater Monitoring Wells: The current upgradient monitoring well MW-1 is located on the opposite side of a low-lying area that collects water and drains to an on -site pond. This well does not represent the groundwater that could be impacted by the irrigation system. MW-1 should be permanently abandoned, and a Well Abandonment Record (Form GW-30) shall be completed and submitted. A new upgradient monitoring well needs to be installed as it has been required since 2008 and a Well Construction Record (Form GW-1) shall be completed and submitted. An updated site map needs to be submitted. B. Residuals Manaeement Plan: 1. A sludge survey needs to be completed. Sludge has not been removed from the lagoons for the lifetime of the system. The ORC asked for methods of determining the amount of sludge in the lagoons. During the March sampling visit, the ORC stated that there are often solids sprayed before the effluent clears up. C. Operation & Maintenance: 1. Please have the sump pump installed in the pumphouse. 2. It was noted in the December 20, 2021 site visit that the drain from the manure capture area is now piped into the lagoons. The concrete pad that collects manure and other leachate is not cover and could introduce stormwater to the lagoons. It is unclear whether the leachate is piped directly into the lagoons or if it goes through the bar screen. Was the pipe part of the original engineering design? If not, when was the pipe installed? Was the regional office or the central office staff notified? D. Site Map: 1. Please provide an updated the site map addressing the following comments: a. The lagoons are not outlined, they are just labeled. The topography labels make it hard to see the lagoons. b. The compliance and review boundaries are incorrect as shown. The compliance boundary is defined by the permit as 500 ft from the effluent disposal area, or the property boundary, whichever is closer. The review boundary is midway between the compliance boundary and the effluent disposal area. There are several areas that needs to be reassessed. c. Distance measurements ensuring all setbacks are being met are not shown. d. Habitable residences and places of assembly within 500ft of all waste treatment, storage, and disposal sites aren't labeled. There may be a habitable residence on the eastern side of the property that is within 500 ft of the spray zones. e. The pond on the property is not labeled and the stream line is not included on the legend of the map. £ The bar screen and grease trap are not shown on the map. g. The map shows a different number of risers in Zone 4. All material that Ms. Caudle and Mr. Moore have shown three risers.